MLMarc Elliot Levenston

Marc Elliot Levenston

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Marc Elliot Levenston has a total of 254 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Hydrogel confinement of the secreted nascent matrix imposes solid stress and mediates pathology of chondrocytes

    by Jake Song, Sarah Loveland, Fan Yang, Nidhi Bhutani, Marc Levenston, Ovijit Chaudhuri

    Mechanical confinement of cells in 3D hydrogel scaffolds mediates cell fate and activity across a wide range of biological processes. Many cells secrete a nascent matrix within the hydrogel niche, which provides important biological signals to the cells but also obstructs direct cell-hydrogel interactions, making it unclear how the cells sense hydrogel confinement and carry out mechanotransduction. Here, we show that chondrocytes sense the solid stress arising from the accumulation of the nascent matrix in the hydrogel niche, which is mediated by hydrogel viscoelasticity and plasticity. We show that solid stresses elicit a wide range of pathophysiological responses, most notably an inflammatory response associated with cartilage osteoarthritis and injury, alongside a striking progenitor-like migratory response where the chondrocytes leverage mitosis to breach their nascent matrix and migrate to escape confinement. Our findings establish the role of the nascent matrix as an important transducer of mechanical confinement and illustrate how emergent solid stresses can drive chondrocyte pathology.

  • Open Access

    How Do the Biomechanical Properties of Four-Strand Semitendinosus Grafts Compare to Those of Four-Strand Semitendinosus + Gracilis Combination Grafts in ACL Reconstruction?

    by Bryan Khoo, Annelisse Cuellar-Montes, Willemijn Hendrike van Deursen, Thomas Johnstone, Wills Baird, Matthew Rohde, Calvin Chan, Marc Levenston, Marc Tompkins, Theodore Ganley, et al.

    Background/Objectives: Hamstring tendon (HT) autografts are commonly used for anterior cruciate ligament reconstruction (ACLR), traditionally combining semitendinosus and gracilis (ST + GR) tendons to achieve adequate graft length and diameter. More recently, four-strand semitendinosus (ST-only) constructs have been adopted to avoid gracilis harvest and reduce donor-site morbidity when sufficient ST tendon length is available. However, to our knowledge, the intrinsic biomechanical properties of four-strand ST-only and ST + GR grafts have not been directly compared. Methods: Twenty-five hamstring allografts (17 ST, 8 GR) from a single provider were prepared into two four-strand configurations: ST-only (n = 9) and ST + GR (n = 8). Manufacturer-reported folded tendon diameters were used to estimate four-strand graft diameters. Grafts underwent preconditioning, cyclic loading (80–250 N), and load-to-failure testing using a servomechanical testing apparatus. Ultimate failure load, stiffness, cyclic elongation, and elongation at failure were recorded. Groups were compared using the Mann–Whitney U test. Results: Mean donor age was 55.8 years (range, 27–72 years). Estimated mean graft diameter was significantly greater for ST-only constructs compared with ST + GR constructs (8.88 ± 0.62 mm vs. 7.70 ± 0.38 mm; p < 0.001). ST-only constructs demonstrated greater stiffness than ST + GR constructs (458.99 ± 54.51 vs. 364.67 ± 57.18 N/mm; p = 0.007) and lower elongation at failure (5.67 ± 1.25 vs. 7.42 ± 0.86 mm; p = 0.01). Cyclic elongation (0.259 ± 0.045 vs. 0.256 ± 0.049 mm; p = 0.89) and ultimate load to failure (1689.84 ± 121.36 vs. 1626.59 ± 324.92 N; p = 0.64) did not differ between groups. Conclusions: When tested in isolation, four-strand ST-only grafts are not biomechanically inferior to ST + GR grafts and demonstrate greater stiffness and larger estimated diameter. When sufficient semitendinosus length is available, ST-only grafts represent a biomechanically viable option for ACLR without the need for gracilis harvest.

  • Open Access

    Texture profile analysis and rheology of plant-based and animal meat

    by Reese A. Dunne, Ethan C. Darwin, Valerie A. Perez Medina, Marc E. Levenston, Skyler R. St. Pierre, Ellen Kuhl

    Plant-based meat can help combat climate change and health risks associated with high meat consumption. To create adequate mimics of animal meats, plant-based meats must match in mouthfeel, taste, and texture. The gold standard to characterize the texture of meat is the double compression test, but this test suffers from a lack of standardization and reporting inconsistencies. Here we characterize the texture of five plant-based and three animal meats using texture profile analysis and rheology, and report ten mechanical features associated with each product’s elasticity, viscosity, and loss of integrity. Our findings suggest that, of all ten features, the stiffness, storage, and loss moduli are the most meaningful and consistent parameter to report, while other parameters suffer from a lack of interpretability and inconsistent definitions. We find that the sample stiffness varies by an order of magnitude, from 418.9±41.7kPa for plant-based turkey to 56.7±14.1kPa for tofu. Similarly, the storage and loss moduli vary from 50.4±4.1kPa and 25.3±3.0kPa for plant-based turkey to 5.7±0.5kPa and 1.3±0.1kPa for tofu. All three animal products, animal turkey, sausage, and hotdog, consistently rank in between these two extremes. Our results suggest that–with the right ingredients, additives, and formulation–modern food fabrication techniques can create plant-based meats that successfully replicate the full viscoelastic texture spectrum of processed animal meat.


  • Open Access

    The mechanical and sensory signature of plant-based and animal meat

    by Skyler R. St. Pierre, Ethan C. Darwin, Divya Adil, Magaly C. Aviles, Archer Date, Reese A. Dunne, Yanav Lall, María Parra Vallecillo, Valerie A. Perez Medina, Kevin Linka, et al.

    Eating less meat is associated with a healthier body and planet. Yet, we remain reluctant to switch to a plant-based diet, largely due to the sensory experience of plant-based meat. Food scientists characterize meat using a double compression test, which only probes one-dimensional behavior. Here we use tension, compression, and shear tests–combined with constitutive neural networks–to automatically discover the behavior of eight plant-based and animal meats across the entire three-dimensional spectrum. We find that plant-based sausage and hotdog, with stiffnesses of 95.9±14.1kPa and 38.7±3.0kPa, successfully mimic their animal counterparts, with 63.5±45.7kPa and 44.3±13.2 kPa, while tofurky is twice as stiff, and tofu is twice as soft. Strikingly, a complementary food tasting survey produces in nearly identical stiffness rankings for all eight products ( ρ =0.833, p=0.015). Probing the fully three-dimensional signature of meats is critical to understand subtle differences in texture that may result in a different perception of taste. Our data and code are freely available at https://github.com/LivingMatterLab/CANN


  • Open Access

    Poster 123: Biomechanical Comparison of Four All-inside Meniscus-Based Repairs to Radial Tears of Human Cadaveric Lateral Menisci

    by Thomas Johnstone, Annelisse Cuellar-Montes, Willemijn van Deursen, Calvin Chan, Marc Tompkins, Henry Ellis, Theodore Ganley, Yi-Meng Yen, Marc Levenston, Seth Sherman, et al.

    Objectives: Meniscal injuries are among the most common orthopedic injuries in the United States. Radial meniscus tears were historically treated with partial meniscectomy, often leading to poor outcomes. Radial tear repair preserves meniscal tissue, may delay knee degeneration, and leads to better long-term outcomes. Repair techniques for radial tears vary and should be evaluated for differences in biomechanical properties and failure mechanisms. All-inside, meniscus-based suture repairs have shorter operating times, minimize risk of nerve injury, and are increasingly possible with novel devices. Our objective was to evaluate the strength based on load-to-failure of four all-inside meniscus-based repair techniques for radial tears in human cadaveric lateral menisci. We chose two techniques that bridged the tear directly – the Double Vertical (DV, Figure 1) and Double Vertical Cross (DVX, Figure 2). We chose two other techniques that added horizontal reinforcing stitches to engage the bridging stitches – the All-inside Rebar (AR, Figure 3) and our novel Oblique Box (OB, Figure 4). We hypothesized that AR and OB would have higher load to failure than DV and DVX. Methods: 36 fresh-frozen human adult lateral menisci were randomized into four groups of nine. Dissection, repair, and testing were completed one meniscus at a time to minimize the time period from thawing to testing. Each meniscus was dissected from its tibial bone block, and a complete radial tear was created at the midbody of the meniscus. Suture repairs were performed using 2-0 braided suture and a straight needle. Menisci were repaired using the DV, DVX, AR, and OB techniques with meniscus- based suturing to simulate the all-inside, meniscus-based approach. All suture dimensions were standardized as indicated on Figures 1-4, and all knots were tied on the superior surface of the menisci. The suture patterns for all repair types used loops that passed above the superior and below the inferior surfaces of the meniscus. The DV repair used two sutures in loops perpendicular to the tear. DVX used two sutures in loops that crossed over the tear. AR used two sutures in loops parallel to the tear acting as reinforcing rebar and two bridging sutures perpendicular to the tear and outside the rebar sutures. OB used two sutures to create a trapezoidal reinforcing box on either side of the tear and two bridging sutures in loops perpendicular to the tear and inside the box. The repaired menisci were loaded on an Instron 5944 test frame with 2 kN load cell using custom clamps. They underwent cyclic loading of 5-30 N for 500 cycles at 10 mm/min, a 30-minute resting period, and a single trial of load-to-failure at 10 mm/min. The ultimate load at failure was analyzed via one-way ANOVA with Tukey’s test for pairwise comparisons and significance set at p<0.05. Results: Failure occurred due to suture cutout in all specimens. Repair constructs that lacked a reinforcing-type suture (DV and DVX) cut through or “cheese-wired” at lower loads than repairs with reinforcing sutures (AR and OB). Mean ± standard deviation ultimate load values for each repair group were 60 N ± 24.5 for DV, 58 N ± 17.4 for DVX, 168 N ± 33.9 for AR, and 105 N ± 9.0 for OB. The ultimate load for all repair techniques were significantly different from each other by Tukey’s test with the exception of the DV and DVX comparison. These results show that reinforcing vertical suture meniscus repairs with some type of horizontal suture (e.g. AR or OB) significantly increases ultimate load at failure for all-inside, meniscus-based techniques. Conclusions: In a cadaveric lateral meniscus model, all-inside radial repairs using rebar suture, or horizontal suture reinforcing techniques, had higher ultimate load at failure and reduced risk of “cheese wiring”. The AR repair sustained the highest ultimate load at failure, nearly 3x stronger than the two non-reinforcing type repair constructs. These data may provide useful information for surgeons during repair to radial meniscus tears. Future biomechanical study should compare all-inside vs. inside-out repairs to maximize patient outcomes. Cross reference of repair patterns with clinical outcomes using the prospective registry data may support optimal surgical techniques to improve meniscus repair outcomes.


  • Open Access

    Poster 237: Menisco-Tibial Ligament Complex Anatomy and Biomechanics – Implications for Meniscus Repairs, Ramp Lesions and Transplants

    by Thomas Johnstone, Annelisse Cuellar-Montes, David Baird, Calvin Chan, Matthew Rohde, Marc Tompkins, Henry Ellis, Theodore Ganley, Yi-Meng Yen, Seth Sherman, et al.

    Objectives: Meniscal injuries are among the most common orthopedic injuries in the United States. Meniscus repairs frequently achieve stability via capsular based repair techniques. Recent studies on meniscal ramp lesions, postero-lateral tears, and meniscus transplants demonstrate some shortcomings of meniscus suture techniques that incorporate menisco-capsular complex (MCC) repair.1-3 Meniscus extrusion may also be affected by the function and integrity of the meniscus/menisco-tibial ligament complex (MTLC).4 Inclusion of the MTLC in some repair/transplant constructs may produce more normal anatomic and biomechanical meniscus function, including the prevention of meniscus extrusion. However, the biomechanical properties of the MTCL in pediatric tissue has not been studied. Our objective was to evaluate the anatomy and biomechanical strength of the MTLC of the medial and lateral meniscus of pediatric knees. We hypothesized: 1) posterior anatomy of the medial and lateral knee would demonstrate a consistent recess or space between the posterior meniscus/MTLC complex and the MCC; and 2) the MTLC would demonstrate unique biomechanical characteristics between the posterior, middle, and anterior 1/3 zones of the medial and lateral meniscus. Methods: 14 fresh-frozen pediatric human knees from 10 donors (mean 7.5 years, range 5-10 years) were used in this study. The distance between the mensico-tibial ligament at the joint capsule and the height of the meniscus was measured with a depth gauge and digital caliper. We define this distance as the depth of the recess between MTLC and MCC (Fig. 1). Subsequently, the medial and lateral menisci were divided into approximate thirds with radial cuts extending through the menisco-tibial ligaments, creating anterior, central, and posterior testing zones for each meniscus (Fig. 2A). The posterior and anterior roots of each meniscus were released from the tibial attachment. Sandpaper was glued to each meniscus segment. Each tibial specimen was potted in fiberglass resin and mounted on an Instron 5944 test frame with a 2 kN load cell. Each meniscus/MTLC complex underwent 10 cycles of preconditioning from 3-5N at 10 mm/min followed by monotonic load to failure testing (Fig. 2B). The depth of recess, load-to-failure, and stiffness (maximum slope of load-displacement curve) were analyzed using linear mixed models with donor and limb as random factors and compartment (M/L) and position as fixed factors. Significance was at p<0.05 and pairwise comparisons used Bonferroni’s test. Results are reported as mean ± s.d. Results: A clear separation of the posterior 1/3 of each meniscus/MTLC and the posterior MCC was seen for each specimen, with a less obvious separation in anterior and central thirds. The depth of recess was significantly larger (p=0.049) in the posterior region (5.41 ± 2.05 mm) than in the anterior region (3.40 ± 2.00 mm), with no significant difference between medial and lateral menisci (Fig. 3). This confirms a distinct separation between the MTLC and the MCC. The load to failure in the anterior region (66.8 ± 31.3 N) was significantly lower than that in the central (91.7 ± 28.0 N, p=0.014) or posterior (93.5 ± 36.5 N, p=0.005) regions, with no significant difference between medial and lateral menisci (Fig. 4A). The stiffness of the central MTLC complex was significantly lower (p=0.014) in lateral menisci (10.0 ± 4.2 N/m) than in medial menisci (18.8 ± 9.4 N/m), with no other significant differences between regions (Fig. 4B). Conclusions: This study defines a clear space in the posterior 1/3 of the medial and lateral meniscus, in which the MTLC complex is distinct from the posterior MCC of the knee joint. This anatomic finding may suggest alternative techniques of meniscus repair/transplant fixation that include direct repair of some meniscus regions to the menisco-tibial ligament instead of meniscus repair to the capsular layer or MCC. This may be of particular importance to Ramp meniscus lesions, other posterior meniscus tear patterns, and meniscus transplant fixation techniques. Our results demonstrate that the central and posterior region of the MTLC can withstand higher loads than the anterior region, indicating that meniscus repairs in the central/posterior region may be of particular importance. These findings support continued development and evaluation of MTLC repair techniques that seek to reproduce the biomechanical and anatomic function of the MTLC, the MCC, and posterior meniscus. Future studies will need to evaluate the impact of MTLC repair on meniscus repair/transplant outcomes and meniscus extrusion. Abrams GD, Frank RM, Gupta AK, Harris JD, McCormick FM, Cole BJ. Trends in meniscus repair and meniscectomy in the United States, 2005-2011. Am J Sports Med. 2013;41(10):2333-2339. doi:10.1177/0363546513495641. Paxton ES, Stock MV, Brophy RH. Meniscal repair versus partial meniscectomy: a systematic review comparing reoperation rates and clinical outcomes. Arthrosc J Arthrosc Relat Surg Off Publ Arthrosc Assoc N Am Int Arthrosc Assoc. 2011;27(9):1275-1288. doi:10.1016/j.arthro.2011.03.088. Vint H, Quartley M, Robinson JR. All-inside versus inside-out meniscal repair: A systematic review and meta-analysis. The Knee. 2021;28:326-337. doi:10.1016/j.knee.2020.12.005. Paletta GA Jr, Crane DM, Konicek J, Piepenbrink M, Higgins LD, Milner JD, Wijdicks CA. Surgical Treatment of Meniscal Extrusion: A Biomechanical Study on the Role of the Medial Meniscotibial Ligaments With Early Clinical Validation. Orthop J Sports Med. 2020;8(7):2325967120936672. Published 2020 Jul 29. doi:10.1177/2325967120936672.

  • Open Access

    Discovering the mechanics of artificial and real meat

    by Skyler R. St. Pierre, Divya Rajasekharan, Ethan C. Darwin, Kevin Linka, Marc Elliot Levenston, Ellen Kuhl

    Artificial meat is an eco-friendly alternative to real meat that is marketed to have a similar taste and feel. The mechanical properties of artificial meat significantly influence our perception of taste, but how precisely the mechanics of artificial meat compare to real meat remains insufficiently understood. Here we perform mechanical tension, compression, and shear tests on isotropic artificial meat (Tofurky® Plant-Based Deli Slices), anisotropic artificial meat (Daring™ Chick’n Pieces) and anisotropic real meat (chicken) and analyze the data using constitutive neural networks and automated model discovery. Our study shows that, when deformed by 10%, artificial and real chicken display similar maximum stresses of 21.0 kPa and 21.8 kPa in tension, -7.2 kPa and -16.4 kPa in compression, and 2.4 kPa and 0.9 kPa in shear, while the maximum stresses for tofurky were 28.5 kPa, -38.3 kP, and 5.5 kPa. To discover the mechanics that best explain these data, we consulted two constitutive neural networks of Ogden and Valanis-Landel type. Both networks robustly discover models and parameters to explain the complex nonlinear behavior of artificial and real meat for individual tension, compression, and shear tests, and for all three tests combined. When constrained to the classical neo Hooke, Blatz Ko, and Mooney Rivlin models, both networks discover shear moduli of 94.4 kPa for tofurky, 35.7 kPa for artificial chick’n, and 21.4 kPa for real chicken. Our results suggests that artificial chicken succeeds in re-producing the mechanical properties of real chicken across all loading modes, while tofurky does not, and is about three times stiffer. Strikingly, all three meat products display shear softening and their resistance to shear is about an order of magnitude lower than their resistance to tension and compression. We anticipate our study to inspire more quantitative, mechanistic comparisons of artificial and real meat. Our automated-model-discovery based approach has the potential to inform the design of more authentic meat substitutes with an improved perception of taste, with the ultimate goal to reduce environmental impact, improve animal welfare, and mitigate climate change, while still offering the familiar taste and texture of traditional meat. Our source code, data, and examples will be available at https://github.com/LivingMatterLab/CANNs .


  • Validating MRI-Derived Myocardial Stiffness Estimates Using In Vitro Synthetic Heart Models

    by Fikunwa O. Kolawole, Mathias Peirlinck, Tyler E. Cork, Marc Levenston, Ellen Kuhl, Daniel B. Ennis

    Impaired cardiac filling in response to increased passive myocardial stiffness contributes to the pathophysiology of heart failure. By leveraging cardiac MRI data and ventricular pressure measurements, we can estimate in vivo passive myocardial stiffness using personalized inverse finite element models. While it is well-known that this approach is subject to uncertainties, only few studies quantify the accuracy of these stiffness estimates. This lack of validation is, at least in part, due to the absence of ground truth in vivo passive myocardial stiffness values. Here, using 3D printing, we created soft, homogenous, isotropic, hyperelastic heart phantoms of varying geometry and stiffness and simulate diastolic filling by incorporating the phantoms into an MRI-compatible left ventricular inflation system. We estimate phantom stiffness from MRI and pressure data using inverse finite element analyses based on a Neo-Hookean model. We demonstrate that our identified softest and stiffest values of 215.7 and 512.3 kPa agree well with the ground truth of 226.2 and 526.4 kPa. Overall, our estimated stiffnesses revealed a good agreement with the ground truth (\(< 5.8\%\) error) across all models. Our results suggest that MRI-driven computational constitutive modeling can accurately estimate synthetic heart material stiffnesses in the range of 200–500 kPa.


  • Open Access

    Contrast solution properties and scan parameters influence the apparent diffusivity of computed tomography contrast agents in articular cartilage

    by Mary E. Hall, Adam S. Wang, Garry E. Gold, Marc E. Levenston

    The inability to detect early degenerative changes to the articular cartilage surface that commonly precede bulk osteoarthritic degradation is an obstacle to early disease detection for research or clinical diagnosis. Leveraging a known artefact that blurs tissue boundaries in clinical arthrograms, contrast agent (CA) diffusivity can be derived from computed tomography arthrography (CTa) scans. We combined experimental and computational approaches to study protocol variations that may alter the CTa-derived apparent diffusivity. In experimental studies on bovine cartilage explants, we examined how CA dilution and transport direction (absorption versus desorption) influence the apparent diffusivity of untreated and enzymatically digested cartilage. Using multiphysics simulations, we examined mechanisms underlying experimental observations and the effects of image resolution, scan interval and early scan termination. The apparent diffusivity during absorption decreased with increasing CA concentration by an amount similar to the increase induced by tissue digestion. Models indicated that osmotically-induced fluid efflux strongly contributed to the concentration effect. Simulated changes to spatial resolution, scan spacing and total scan time all influenced the apparent diffusivity, indicating the importance of consistent protocols. With careful control of imaging protocols and interpretations guided by transport models, CTa-derived diffusivity offers promise as a biomarker for early degenerative changes.


  • Open Access

    Validation of watershed-based segmentation of the cartilage surface from sequential CT arthrography scans

    by Mary E. Hall, Marianne S. Black, Garry E. Gold, Marc E. Levenston

    Validation of watershed-based segmentation of the cartilage surface from sequential CT arthrography scans Mary E. Hall, Marianne S. Black, Garry E. Gold, Marc E. Levenston