AFAnja Franken

Anja Franken

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Anja Franken has a total of 66 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Dermal exposure and surface contamination associated with the use of a cobalt-chrome alloy during additive manufacturing

    by Lynicka Paulse, Sonette du Preez, Anja Franken, Johan du Plessis

    Background: Amidst the rapidly emerging additive manufacturing (AM) industry, not enough attention has been given to dermal exposure, with only one previous study that assessed dermal exposure to metals. Our study aimed to characterise a cobalt (Co)-chrome (Cr) alloy feedstock powder (CO-538) in terms of particle size, shape, and elemental composition, and assess dermal exposure and workplace surface contamination during powder bed fusion AM. Methods: Particle size distribution (PSD) and shape of the virgin and used feedstock powder were determined using static image and scanning electron microscopy analyses. The elemental composition of powders was established using inductively coupled plasma-optical emission spectrometry. A removal wipe sampling method using Ghostwipes was performed on AM operators’ skin at various locations (index finger, palm, wrist, back of the hand, and neck), before and after each AM processing phase. Workplace surfaces (both AM and non-AM areas) were also sampled before and after each shift using a removal wipe method to measure surface contamination. Results: PSD analysis revealed a significant difference (P ≤ 0.05) in median size, with used powder exhibiting smaller particles than virgin, where 10% of particles were smaller than the given diameter. Additionally, significant differences (P ≤ 0.05) were noted in the mean circularity and convexity between virgin and used powders, indicating that used powder particles were more irregular and rougher compared to virgin. The CO-538 feedstock powder contained Co, Cr, molybdenum (Mo), aluminium (Al), iron (Fe), and Ni. These metals were also detected on the skin of AM operators and on surfaces within the AM and non-AM areas of the facility. Dermal exposure occurred on all of the anatomical areas, with the highest total metal concentration detected on the index finger during the post-processing phase of AM. The highest full-shift geometric mean GM concentration of each metal was detected on the finger and followed a trend of Co > Cr > Fe > Al > Mo > Ni. Surface contamination occurred on all AM and non-AM sampling areas after a full shift. Conclusions: Dermal exposure to all CO-538 alloy metal constituents occurred on all sampled anatomical areas during all three processing phases. Measurable concentrations of metals that were detected on all sampled surfaces indicate that cross-contamination between AM and non-AM areas occurs and that these surfaces may act as a secondary source of exposure. There is thus a need for control measures to be implemented in AM facilities to eliminate or reduce surface metal contamination and dermal exposure.


  • Breaking barriers: women’s impact on occupational hygiene in South Africa

    by A Franken, K du Preez, S du Preez, J Hills, G Keretetse, E Lourens, J Manganyi, N Mundy, Z Selenati-Dreyer, J van Niekerk

  • Skin Barrier Function of Black African and White Nursing Students

    by Monica Young, Anja Franken, Johannes Lodewykus du Plessis

    Aims: Assessment of skin biophysical parameters in a South African nursing population may provide insight in long-term changes in their skin condition in a practical setting. This study aimed to investigate changes in skin barrier function parameters over a period of 2 years, in nursing students completing their tertiary education. Methods: Transepidermal water loss, stratum corneum (SC) hydration, and skin surface pH were measured in female nursing students (63 white, 42 Black African) three times a year and repeated for 2 years. Linear mixed models and Bonferroni post hoc tests were performed to test changes over time in skin barrier function parameters. Results: Transepidermal water loss and SC hydration significantly (p < .001) decreased over 2 years in first-year students, whereas only specific differences were established for senior students. Skin surface pH significantly (p < .001) varied over the 2 years with significant increases (p < .031) in the winter months. The only significant difference (p < .001) between white and Black African students was established in skin surface pH. Conclusion: This study demonstrated the variability of skin barrier function parameters, specifically seasonal variation in skin surface pH. This study also revealed possible long-term changes in skin condition through the recovery of the SC in a practical setting.

  • Open Access

    Natural moisturising factor constituents in South African nursing students

    by Monica Young, Johannes Lodewykus du Plessis, Sanja Kezic, Ivone Jakasa, Anja Franken

    BackgroundThe majority of South African healthcare workers are Black Africans with dark-pigmented skin. Studies on how the markers of skin barrier function and natural moisturising factor (NMF) compare between dark and light-pigmented skin are limited. Quantifying NMF in a nursing student population during their practical training at university may provide valuable insight into their potential susceptibility to skin conditions associated with low NMF.ObjectivesThe objectives of this study were to quantify and compare NMF content of Black African, Mixed Race and White nursing students from their dominant dorsal hand.MethodsForty-nine White, 32 Black African and 5 Mixed Race nursing students participated in this study. Tape strip samples were collected from the participants' dominant dorsal hand and NMF content was measured, including histidine (HIS), pyrrolidone carboxylic acid (PCA), trans-urocanic acid (t-UCA) and cis-urocanic acid (c-UCA), as well as cytokines interleukin-1 alpha (IL-1 alpha) and interleukin-1 receptor antagonist (IL-1RA).ResultsNo statistically significant differences in PCA, t-UCA, c-UCA, IL-1 alpha or IL-1RA were found between Black African and White nursing students. HIS was significantly (p = 0.001) higher in White nursing students when compared to Black African students. The ratio of tot-UCA/HIS was significantly higher in Black Africans (p = 0.0002) when compared to White nursing students.ConclusionNo significant differences were established in NMF content between White and Black African nursing students, other than HIS which was significantly higher in White students than in Black African students. Different HIS levels between the racial groups suggest variation in histidase activity which may be related to skin pH and pigmentation. This finding may suggest that nursing students at the beginning of their careers may have similar susceptibility to skin diseases related to NMF. NMF content, including pyrrolidone carboxylic acid (PCA), trans-urocanic acid (t-UCA) and cis-urocanic acid (c-UCA), as well as cytokines interleukin-1 alpha (IL-1 alpha) and interleukin-1 receptor antagonist (IL-1RA), was not significantly different between White and Black African nursing students. Histidine (HIS) content was significantly higher in White nursing students. image

  • Open Access

    In vitro skin permeation of potassium hexachloroplatinate and a comparison with potassium tetrachloroplatinate

    by Anja Franken, Barbara Sylvia Bosch, Cornelius Johannes van der Merwe, Jeanetta Du Plessis, Johannes Lodewykus Du Plessis


  • Effectiveness of Personal Protective Equipment in Reducing Skin Exposure to Soluble Platinum

    by Stephanus J L Linde, Anja Franken, Johannes L du Plessis

    Objectives: Various forms of personal protective equipment (PPE), including disposable coveralls and gloves, are used to help reduce skin exposure to soluble platinum in precious metals refineries. We aimed to investigate the effectiveness of PPE in reducing workers’ skin exposure to soluble platinum. Methods: Thirty precious metals refinery workers were divided into two groups according to their use of PPE and related procedures. Group A (n = 13) used disposable coveralls worn over standard overalls along with long-sleeved rubber gloves, while Group B (n = 17) used standard overalls only and surgical nitrile gloves. The skin (palm, wrist, neck, and forehead) and respiratory exposure of these groups to soluble platinum were concurrently measured (using Ghostwipes™ and MDHS 46/2, respectively) along with their urinary platinum excretion. Results: Both groups of workers experienced comparable geometric mean (GM) respiratory exposure to soluble platinum (Group A = 0.744 µg m−3 versus Group B = 0.711 µg m−3) (P = 0.789), but significantly lower skin exposure (average of all measured anatomical areas) was found for Group A (Group A = 0.005 µg cm−2 versus Group B = 0.033 µg cm−2) (P = 0.018). Significantly lower skin exposure was measured on the palm (P = 0.017), wrist (P = 0.017), forehead (P = 0.027) of Group A workers compared with Group B. No significant difference was found for the urinary platinum excretion of the two groups (Group A GM = 0.208 µg g−1 creatinine versus Group B GM = 0.361 µg g−1 creatinine) (P = 0.273). Conclusions: The use of disposable coveralls and long-sleeved rubber gloves, along with strict usage procedures, proved effective in reducing precious metals refinery workers’ skin exposure to soluble platinum.


  • Reflections on the OECD guidelines for in vitro skin absorption studies

    by N.B. Hopf, C. Champmartin, L. Schenk, A. Berthet, L. Chedik, J.L. Du Plessis, A. Franken, F. Frasch, S. Gaskin, G. Johanson, et al.


  • Particle size and metal composition of gouging and lancing fumes

    by Marelé Keyter, Alicia Van Der Merwe, Anja Franken

    Metal gouging and lancing liberate particles of an unknown size and composition. Fumes are formed when vaporized materials condense in air, creating fine and ultrafine particles which can agglomerate. Particle sizes may be 3 (inhalable), 1.83–13.96 mg/m3 (thoracic) and 0.88–15.82 mg/m3 (respirable) for gouging; and 2.34–5.60 mg/m3 (inhalable), 2.82–4.01 mg/m3 (thoracic), and 1.89–3.24 mg/m3 (respirable) for lancing. PSD analysis confirmed the presence of nano-size particles with a mean size of 171.76 (±56.27) nm during gouging and 32.33 (±7.17) nm during lancing. Inductively Coupled Plasma Mass Spectrometry (ICP-MS) analysis of samples indicated the presence of chromium (Cr), copper (Cu), iron (Fe), manganese (Mn), molybdenum (Mo), nickel (Ni), and tin (Sn) in the respective particle size fractions (including nano-size) of both processes. Negative health effects associated with metal inhalation are well known, while nanoparticles’ unique properties enable them to cause further detrimental health effects. The nano-size fraction should be included in personal exposure assessments and control measures.


  • Open Access

    Measurement of transepidermal water loss, stratum corneum hydration and skin surface pH in occupational settings: A review

    by Sané Jansen van Rensburg, Anja Franken, Johannes Lodewykus Du Plessis

    Background: The skin provides a permeable barrier which may be impaired in occupational settings. Transepidermal water loss (TEWL), stratum corneum hydration (SCH) and skin surface pH (SSpH) have been used in occupational settings to predict early onset of occupational skin diseases, to measure the effectiveness of prevention strategies for occupational skin diseases, and to assess skin condition during exposure. The aim was to compare the findings, identify shortcomings in the methodology and data reporting and furthermore, to make recommendations for future studies.Materials and Methods: A literature study was conducted on studies published before December 2018 to provide a review on the measurement of TEWL, SCH and SSpH in occupational settings.Results: TEWL, SCH and SSpH were previously measured in a wide variety of industries. Results between studies were highly variable, due to different study designs and different anatomical positions measured. Not all of the measurement conditions were reported and variations in study objectives led to data being reported and interpreted differently for most studies.Conclusion: Incomplete reporting of methodology hinders comparison of bioengineering measurements. No bioengineering method has been proven useful as a predictive tool for occupational skin diseases, however, it is useful in the acute assessment of skin condition. It is recommended that future studies on TEWL, SCH and SSpH adhere to guidelines for occupational settings as far as possible to enable comparison between studies.


  • Transepidermal water loss, stratum corneum hydration, and skin surface pH of female African and Caucasian nursing students

    by Monica M Young, Anja Franken, Johan L du Plessis

    Background: Conflicting evidence exists on how skin barrier function compares between Africans and Caucasians. This study measured skin barrier function of South African first year nursing students before their practical training started to compare skin barrier function between the racial groups.Methods: Transepidermal water loss (TEWL), stratum corneum (SC) hydration, and skin surface (SS) pH was measured on female first year nursing students (19 African and 31 Caucasian; age range 18‐40 years). Geometric means and ranges were calculated and the influence of anatomical areas and racial differences were evaluated respectively.Results: No significant difference in TEWL was established between the racial groups. SC hydration was significantly lower (P ≤ 0.05) and SS‐pH was significantly higher (P ≤ 0.0001) in African nursing students when compared to Caucasians. African nursing students had significantly lower (P ≤ 0.05) SC hydration on their palms when compared to the other anatomical areas.Conclusion: Stratum corneum hydration and SS‐pH differed significantly between African and Caucasian skin, while no difference was found for TEWL, the primary parameter used to evaluate skin barrier function. Low SC hydration and high SS‐pH of African nursing students prior to their practical training, may suggest a higher risk for developing occupational skin diseases.