Martin Wehner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Martin Wehner has a total of 108 co-authors. Here are the top co-authors by number of shared publications:
Philipp Jacobs
Fraunhofer Institute for Laser Technology ILT, Aachen, Germany
5 shared publicationsReinhart Poprawe
Fraunhofer Institute for Laser Technology
4 shared publicationsManfred Bovi
Universitätsklinikum Aachen
3 shared publicationsR. Poprawe
Fraunhofer Institute for Lasertechnology
3 shared publications- Stefan Schillberg
Fraunhofer Institute for Molecular Biology and Applied Ecology IME Forckenbeckstrasse 6 52074 Aachen Germany
3 shared publications Arnold Gillner
Fraunhofer-Institut fuer Lasertechnik (Germany)
2 shared publications
Latest Publications
- Open Access
- 26 September 2020
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 21 (19) , 7104
In Vitro Feasibility Analysis of a New Sutureless Wound-Closure System Based on a Temperature-Regulated Laser and a Transparent Collagen Membrane for Laser Tissue Soldering (LTS)
For the post-surgical treatment of oral wounds and mucosal defects beyond a certain size, the gold standard is still an autologous skin or mucosal graft in combination with complex suturing techniques. A variety of techniques and biomaterials has been developed for sutureless wound closure including different tissue glues or collagen patches. However, no wound covering that enables for sutureless fixation has yet been introduced. Thus, a new system was developed that allows for sutureless wound covering including a transparent collagen membrane, which can be attached to the mucosa using a specially modified 2λ laser beam with integrated temperature sensors and serum albumin as bio-adhesive. The sutureless wound closure system was tested for its applicability and its cytocompatibility by an established in vitro model in the present study. The feasibility of the laser system was tested ex vivo on a porcine palate. The in vitro cytocompatibility tests excluded the potential release of toxic substances from the laser-irradiated collagen membrane and the bio-adhesive. The results of the ex vivo feasibility study using a porcine palate revealed satisfactory mean tensile strength of 1.2–1.5 N for the bonding of the membrane to the tissue fixed with laser of 980 nm. The results suggest that our newly developed laser-assisted wound closure system is a feasible approach and could be a first step on the way towards a laser based sutureless clinical application in tissue repair and oral surgery.
- 26 September 2020
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 21 (19) , 7104
Open AccessIn Vitro Feasibility Analysis of a New Sutureless Wound-Closure System Based on a Temperature-Regulated Laser and a Transparent Collagen Membrane for Laser Tissue Soldering (LTS)
For the post-surgical treatment of oral wounds and mucosal defects beyond a certain size, the gold standard is still an autologous skin or mucosal graft in combination with complex suturing techniques. A variety of techniques and biomaterials has been developed for sutureless wound closure including different tissue glues or collagen patches. However, no wound covering that enables for sutureless fixation has yet been introduced. Thus, a new system was developed that allows for sutureless wound covering including a transparent collagen membrane, which can be attached to the mucosa using a specially modified 2λ laser beam with integrated temperature sensors and serum albumin as bio-adhesive. The sutureless wound closure system was tested for its applicability and its cytocompatibility by an established in vitro model in the present study. The feasibility of the laser system was tested ex vivo on a porcine palate. The in vitro cytocompatibility tests excluded the potential release of toxic substances from the laser-irradiated collagen membrane and the bio-adhesive. The results of the ex vivo feasibility study using a porcine palate revealed satisfactory mean tensile strength of 1.2–1.5 N for the bonding of the membrane to the tissue fixed with laser of 980 nm. The results suggest that our newly developed laser-assisted wound closure system is a feasible approach and could be a first step on the way towards a laser based sutureless clinical application in tissue repair and oral surgery.
- Open Access
- 24 July 2018
- Published by Springer Nature in Lasers in Medical Science
- Vol. 34 (2) , 335-341
Influence of laser wavelength and beam profile on the coagulation depth in a soft tissue phantom model
In laser tissue soldering (LTS), a protein solution is thermally denatured and cross-linked to obtain a strong bond between tissues or tissue and a wound dressing. However, if the extension of the heat-affected zone is too large, wound healing is impaired by thermal tissue injuries. Therefore, heat input and coagulation depth have to be limited. We investigate the influence of wavelength and beam profile on coagulation depth using a soft tissue phantom in case of weakly (980 nm) and strong (1540 nm) absorbed laser radiation. The soft tissue phantom is doped with polystyrene (PS) beads to obtain similar scattering properties as natural tissue. The propagation of the laser radiation in the phantom is simulated by Monte–Carlo method and the optical penetration (OPD) depth calculated from isophotes. The simulation results are compared with the experimental determination of the coagulation volume. The results reveal that scattering effect of tissues on laser radiation increases the losses of a Gaussian beam profile laterally leading to a half-sphere coagulation volume. The depth profile of the coagulation follows approximately the intensity distribution of the laser beams as long as scattering effects are weak. As scattering effects become significant, as for 980-nm radiation, the intensity distribution of the laser beam in the tissue deviates from the original one, leading to different profile of the coagulation depth.
- 24 July 2018
- Published by Springer Nature in Lasers in Medical Science
- Vol. 34 (2) , 335-341
Open AccessInfluence of laser wavelength and beam profile on the coagulation depth in a soft tissue phantom model
In laser tissue soldering (LTS), a protein solution is thermally denatured and cross-linked to obtain a strong bond between tissues or tissue and a wound dressing. However, if the extension of the heat-affected zone is too large, wound healing is impaired by thermal tissue injuries. Therefore, heat input and coagulation depth have to be limited. We investigate the influence of wavelength and beam profile on coagulation depth using a soft tissue phantom in case of weakly (980 nm) and strong (1540 nm) absorbed laser radiation. The soft tissue phantom is doped with polystyrene (PS) beads to obtain similar scattering properties as natural tissue. The propagation of the laser radiation in the phantom is simulated by Monte–Carlo method and the optical penetration (OPD) depth calculated from isophotes. The simulation results are compared with the experimental determination of the coagulation volume. The results reveal that scattering effect of tissues on laser radiation increases the losses of a Gaussian beam profile laterally leading to a half-sphere coagulation volume. The depth profile of the coagulation follows approximately the intensity distribution of the laser beams as long as scattering effects are weak. As scattering effects become significant, as for 980-nm radiation, the intensity distribution of the laser beam in the tissue deviates from the original one, leading to different profile of the coagulation depth.
- 7 December 2017
- Published by SPIE-Intl Soc Optical Eng
- p. 9
Monitoring soft tissue coagulation by optical spectroscopy
- 7 December 2017
- Published by SPIE-Intl Soc Optical Eng
- p. 9
Monitoring soft tissue coagulation by optical spectroscopy
- 1 January 2017
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 62 (s1) , s42-s45
Session 12. Cells, materials and biochemistry II
- 1 January 2017
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 62 (s1) , s42-s45
Session 12. Cells, materials and biochemistry II
- 23 August 2016
- Published by Springer Nature
- p. 93-114
Laser-Based Stapes Surgery
- 1 January 2016
- Published by Elsevier in Journal of Biotechnology
- Vol. 217, 100-108
Determination of the thermal properties of leaves by non-invasive contact‑free laser probing
- 1 January 2016
- Published by Elsevier in Journal of Biotechnology
- Vol. 217, 100-108
Determination of the thermal properties of leaves by non-invasive contact‑free laser probing
- 29 August 2015
- Published by Springer Nature in Applied Physics A
- Vol. 121 (2) , 513-519
The voxel onset time as an in situ method to evaluate focal position effects on two-photon-induced lithography
- 29 August 2015
- Published by Springer Nature in Applied Physics A
- Vol. 121 (2) , 513-519
The voxel onset time as an in situ method to evaluate focal position effects on two-photon-induced lithography
- 5 March 2015
- Published by SPIE-Intl Soc Optical Eng
- p. 932109-932109-9
Two-wavelength approach for control of coagulation depth during laser tissue soldering
- 5 March 2015
- Published by SPIE-Intl Soc Optical Eng
- p. 932109-932109-9
Two-wavelength approach for control of coagulation depth during laser tissue soldering
- 8 May 2012
- Published by Springer Nature in Lasers in Medical Science
- Vol. 28 (1) , 171-184
Precise ablation of dental hard tissues with ultra-short pulsed lasers. Preliminary exploratory investigation on adequate laser parameters
This study aimed to evaluate the possibility of introducing ultra-short pulsed lasers (USPL) in restorative dentistry by maintaining the well-known benefits of lasers for caries removal, but also overcoming disadvantages, such as thermal damage of irradiated substrate. USPL ablation of dental hard tissues was investigated in two phases. Phase 1—different wavelengths (355, 532, 1,045, and 1,064 nm), pulse durations (picoseconds and femtoseconds) and irradiation parameters (scanning speed, output power, and pulse repetition rate) were assessed for enamel and dentin. Ablation rate was determined, and the temperature increase measured in real time. Phase 2—the most favorable laser parameters were evaluated to correlate temperature increase to ablation rate and ablation efficiency. The influence of cooling methods (air, air–water spray) on ablation process was further analyzed. All parameters tested provided precise and selective tissue ablation. For all lasers, faster scanning speeds resulted in better interaction and reduced temperature increase. The most adequate results were observed for the 1064-nm ps-laser and the 1045-nm fs-laser. Forced cooling caused moderate changes in temperature increase, but reduced ablation, being considered unnecessary during irradiation with USPL. For dentin, the correlation between temperature increase and ablation efficiency was satisfactory for both pulse durations, while for enamel, the best correlation was observed for fs-laser, independently of the power used. USPL may be suitable for cavity preparation in dentin and enamel, since effective ablation and low temperature increase were observed. If adequate laser parameters are selected, this technique seems to be promising for promoting the laser-assisted, minimally invasive approach.
- 8 May 2012
- Published by Springer Nature in Lasers in Medical Science
- Vol. 28 (1) , 171-184
Precise ablation of dental hard tissues with ultra-short pulsed lasers. Preliminary exploratory investigation on adequate laser parameters
This study aimed to evaluate the possibility of introducing ultra-short pulsed lasers (USPL) in restorative dentistry by maintaining the well-known benefits of lasers for caries removal, but also overcoming disadvantages, such as thermal damage of irradiated substrate. USPL ablation of dental hard tissues was investigated in two phases. Phase 1—different wavelengths (355, 532, 1,045, and 1,064 nm), pulse durations (picoseconds and femtoseconds) and irradiation parameters (scanning speed, output power, and pulse repetition rate) were assessed for enamel and dentin. Ablation rate was determined, and the temperature increase measured in real time. Phase 2—the most favorable laser parameters were evaluated to correlate temperature increase to ablation rate and ablation efficiency. The influence of cooling methods (air, air–water spray) on ablation process was further analyzed. All parameters tested provided precise and selective tissue ablation. For all lasers, faster scanning speeds resulted in better interaction and reduced temperature increase. The most adequate results were observed for the 1064-nm ps-laser and the 1045-nm fs-laser. Forced cooling caused moderate changes in temperature increase, but reduced ablation, being considered unnecessary during irradiation with USPL. For dentin, the correlation between temperature increase and ablation efficiency was satisfactory for both pulse durations, while for enamel, the best correlation was observed for fs-laser, independently of the power used. USPL may be suitable for cavity preparation in dentin and enamel, since effective ablation and low temperature increase were observed. If adequate laser parameters are selected, this technique seems to be promising for promoting the laser-assisted, minimally invasive approach.
- 17 March 2012
- Published by Springer Nature in Applied Physics A
- Vol. 107 (3) , 691-696
CdSe-ZnS quantum dots as temperature sensors during thermal coagulation of bovine serum albumin (BSA) solder
- 17 March 2012
- Published by Springer Nature in Applied Physics A
- Vol. 107 (3) , 691-696
CdSe-ZnS quantum dots as temperature sensors during thermal coagulation of bovine serum albumin (BSA) solder