Ali F. Alghamdi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ali F. Alghamdi has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Abdulilah Dawoud Bani-Yaseen
Taibah University
1 shared publication- Abdulrahman A. Al Majed
Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh 11451, Saudi Arabia
1 shared publication - Fathallah Belal
Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy Mansoura University Mansoura Egypt
1 shared publication M. Messali
1 shared publication- Mohamed A. Al- Omar
Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P. O. Box 2457, Riyadh 11451, Saudi Arabia
1 shared publication - Mohamed Hefnawy
Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia
1 shared publication
Latest Publications
- 15 September 2018
- Published by Elsevier in Journal of Molecular Liquids
- Vol. 266, 112-117
Green synthesis of new ionic liquid and its electrochemical determination at some detergents and cosmetics samples using differential pulse polarography
- 15 September 2018
- Published by Elsevier in Journal of Molecular Liquids
- Vol. 266, 112-117
Green synthesis of new ionic liquid and its electrochemical determination at some detergents and cosmetics samples using differential pulse polarography
- 1 January 2018
- Published by Bentham Science Publishers Ltd. in Current Analytical Chemistry
- Vol. 14 (2) , 92-100
High Sensitivity Determination of Atorvastatin Calcium in Pharmaceuticals and Biological Fluids Using Adsorptive Anodic Stripping Voltammetry onto Surface of Ultra-Trace Graphite Electrode
Background: Atorvastatin calcium belongs to a group of drugs known as statins. It is commonly used to treat a heart disease, so it is used to lower or reduce the fats and bad cholesterol in blood. It has also been used to increase the good cholesterol in blood. Atorvastatin calcium content is commercially known as "Lipitor" tablet. It is available in local pharmacies at different concentrations; 10, 20 and 40mg. Atorvastatin calcium has been previously determined by several analytical techniques such as chromatographic methods, spectrophotometry and electrochemical methods. Methods: Atorvastatin calcium drug was determined in pharmaceuticals using voltammetric techniques, HPLC and UV Vis onto surface of ultra-trace graphite (UT) working electrode. It was also analysed by voltammetric techniques in biological fluids such as plasma and urine. Results: Some analytical parameters were evaluated such as buffer solutions, pH, accumulation time and potential, frequency, scan rate, amplitude voltage step and rate of stirring, using UT electrode vs. Ag/AgCl reference electrode and Pt auxiliary electrode. There are some parameters such as recovery, reproducibility, stability, calibration curve, detection limit, quantification limit and interference, which were also studied. Analytical applications for ATOR were carried out using pharmaceuticals that contained 10, 20 and 40 mg ATOR; and biological samples. Spectrophotometric and HPLC procedures were used for analytical applications to compare their results with anodic stripping voltammetry in terms of accuracy and precision. Conclusion: The developed adsorptive anodic stripping voltammetric method was applied for the determination of ATOR using phosphate buffer at pH3 ATOR at phosphate buffer pH3, 30 s tacc, -0.6 V Eacc, 50 mV amplitude and 3000 rpm in its pharmaceuticals and biological samples. In this research, the determination of ATOR confirmed a high sensitivity of adsorptive anodic stripping voltammetry method comparing other electrochemical methods. The LOD and LOQ also confirmed the sensitivity of the adsorptive anodic stripping voltammetric method. HPLC and UV Vis spectrophotometric methods were used for the comparison of results with adsorptive anodic stripping voltammetry concerning analytical application of ATOR tablets. There are many published articles for the determination of ATOR, but they were lower than adsorptive anodic stripping voltammetry in terms of sensitivity and an ultra trace graphite working electrode was used in this research as an additional advantage.
- 1 January 2018
- Published by Bentham Science Publishers Ltd. in Current Analytical Chemistry
- Vol. 14 (2) , 92-100
High Sensitivity Determination of Atorvastatin Calcium in Pharmaceuticals and Biological Fluids Using Adsorptive Anodic Stripping Voltammetry onto Surface of Ultra-Trace Graphite Electrode
Background: Atorvastatin calcium belongs to a group of drugs known as statins. It is commonly used to treat a heart disease, so it is used to lower or reduce the fats and bad cholesterol in blood. It has also been used to increase the good cholesterol in blood. Atorvastatin calcium content is commercially known as "Lipitor" tablet. It is available in local pharmacies at different concentrations; 10, 20 and 40mg. Atorvastatin calcium has been previously determined by several analytical techniques such as chromatographic methods, spectrophotometry and electrochemical methods. Methods: Atorvastatin calcium drug was determined in pharmaceuticals using voltammetric techniques, HPLC and UV Vis onto surface of ultra-trace graphite (UT) working electrode. It was also analysed by voltammetric techniques in biological fluids such as plasma and urine. Results: Some analytical parameters were evaluated such as buffer solutions, pH, accumulation time and potential, frequency, scan rate, amplitude voltage step and rate of stirring, using UT electrode vs. Ag/AgCl reference electrode and Pt auxiliary electrode. There are some parameters such as recovery, reproducibility, stability, calibration curve, detection limit, quantification limit and interference, which were also studied. Analytical applications for ATOR were carried out using pharmaceuticals that contained 10, 20 and 40 mg ATOR; and biological samples. Spectrophotometric and HPLC procedures were used for analytical applications to compare their results with anodic stripping voltammetry in terms of accuracy and precision. Conclusion: The developed adsorptive anodic stripping voltammetric method was applied for the determination of ATOR using phosphate buffer at pH3 ATOR at phosphate buffer pH3, 30 s tacc, -0.6 V Eacc, 50 mV amplitude and 3000 rpm in its pharmaceuticals and biological samples. In this research, the determination of ATOR confirmed a high sensitivity of adsorptive anodic stripping voltammetry method comparing other electrochemical methods. The LOD and LOQ also confirmed the sensitivity of the adsorptive anodic stripping voltammetric method. HPLC and UV Vis spectrophotometric methods were used for the comparison of results with adsorptive anodic stripping voltammetry concerning analytical application of ATOR tablets. There are many published articles for the determination of ATOR, but they were lower than adsorptive anodic stripping voltammetry in terms of sensitivity and an ultra trace graphite working electrode was used in this research as an additional advantage.
- Open Access
- 1 September 2017
- Published by Taylor & Francis in Journal of Taibah University for Science
- Vol. 11 (5) , 759-767
Novel acyclonucleoside analog bearing a 1,2,4-triazole–Schiff base: Synthesis, characterization and analytical studies using square wave-adsorptive stripping voltammetry and HPLC
New acyclonucleoside analogs tethered by a 1,2,4-triazole scaffold were synthesized through the condensation of 4-amino-5-(2-phenyleth-1-yl)-2,4-dihydro-3H-1,2,4-triazole-3-thione (2) with benzaldehyde followed by the alkylation of the resulting Schiff base (3)with 2-bromoethanol, 3-chloropropanol and/or 3-chloropropan-1,2-diol. Voltammetric studies were carried out for the analysis of 1×10−6molL−1 of the newly synthesized acyclonucleoside analogs (4–6) using square wave-adsorptive stripping voltammetry (SW-AdSV). The sharp voltammetric peak and high reduction current were recorded using a Britton–Robinson B–R pH 10 buffer at Ep=−1250mV on the hanging mercury drop surface (HMDE) and Ag/AgCl reference electrode. Several experimental conditions were studied, such as the supporting electrolytes, the pH, and the accumulation time, as well as the potential, the scan rate, the frequency and the step potential for 4-benzylideneamino-5-(2-phenyleth-1-yl)-3-[(2,3-dihydroxyprop-1-yl)thio]-1,2,4-triazole (6). The analytical performance of the voltammetric technique was investigated through the analysis of the calibration curve, the detection limit, the recovery and the stability. The voltammetric analytical applications were evaluated by the recovery of compound (6) in the urine and plasma samples. The HPLC technique was also applied for the separation of compound (6) from interference using a C-18 (5μm) column with UV detection at 254nm
- 1 September 2017
- Published by Taylor & Francis in Journal of Taibah University for Science
- Vol. 11 (5) , 759-767
Open AccessNovel acyclonucleoside analog bearing a 1,2,4-triazole–Schiff base: Synthesis, characterization and analytical studies using square wave-adsorptive stripping voltammetry and HPLC
New acyclonucleoside analogs tethered by a 1,2,4-triazole scaffold were synthesized through the condensation of 4-amino-5-(2-phenyleth-1-yl)-2,4-dihydro-3H-1,2,4-triazole-3-thione (2) with benzaldehyde followed by the alkylation of the resulting Schiff base (3)with 2-bromoethanol, 3-chloropropanol and/or 3-chloropropan-1,2-diol. Voltammetric studies were carried out for the analysis of 1×10−6molL−1 of the newly synthesized acyclonucleoside analogs (4–6) using square wave-adsorptive stripping voltammetry (SW-AdSV). The sharp voltammetric peak and high reduction current were recorded using a Britton–Robinson B–R pH 10 buffer at Ep=−1250mV on the hanging mercury drop surface (HMDE) and Ag/AgCl reference electrode. Several experimental conditions were studied, such as the supporting electrolytes, the pH, and the accumulation time, as well as the potential, the scan rate, the frequency and the step potential for 4-benzylideneamino-5-(2-phenyleth-1-yl)-3-[(2,3-dihydroxyprop-1-yl)thio]-1,2,4-triazole (6). The analytical performance of the voltammetric technique was investigated through the analysis of the calibration curve, the detection limit, the recovery and the stability. The voltammetric analytical applications were evaluated by the recovery of compound (6) in the urine and plasma samples. The HPLC technique was also applied for the separation of compound (6) from interference using a C-18 (5μm) column with UV detection at 254nm
- 1 June 2016
- Published by Elsevier in Journal of Molecular Liquids
- Vol. 218, 186-190
Cyclic voltammetric studies of a new 1-pentylpyridazinium bromide ionic liquid and its determination in detergents and sea water samples
- 1 June 2016
- Published by Elsevier in Journal of Molecular Liquids
- Vol. 218, 186-190
Cyclic voltammetric studies of a new 1-pentylpyridazinium bromide ionic liquid and its determination in detergents and sea water samples
- Open Access
- 1 January 2016
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 28 (6) , 1225-1228
A Novel Pyridazinium Ionic Liquid: Ultrasound Synthesis, Characterization and its Analytical Application Using Cyclic Voltammetry and High Performance Liquid Chromatography
- 1 January 2016
- Published by Asian Publication Corporation in Asian Journal of Chemistry
- Vol. 28 (6) , 1225-1228
Open AccessA Novel Pyridazinium Ionic Liquid: Ultrasound Synthesis, Characterization and its Analytical Application Using Cyclic Voltammetry and High Performance Liquid Chromatography
- 1 March 2015
- Published by Springer Nature in Pharmaceutical Chemistry Journal
- Vol. 48 (12) , 843-847
Quantitative Analysis of Hydrochlorothiazide and Its Determination in a Pharmaceutical Preparation by HPLC
- 1 March 2015
- Published by Springer Nature in Pharmaceutical Chemistry Journal
- Vol. 48 (12) , 843-847
Quantitative Analysis of Hydrochlorothiazide and Its Determination in a Pharmaceutical Preparation by HPLC
- Open Access
- 1 September 2014
- Published by The Journal of Food and Drug Analysis (JFDA), Food and Drug Administration, Taiwan (TFDA) in Journal of Food and Drug Analysis
- Vol. 22 (3) , 363-369
Electrochemical oxidation behavior of hydrochlorothiazide on a glassy carbon electrode and its voltammetric determination in pharmaceutical formulations and biological fluids
The electrochemical oxidation behavior of hydrochlorothiazide (HCT) on a glassy carbon as a working electrode was investigated in Britton-Robinson (B-R) buffer pH 3, by using anodic stripping voltammetry (ASV) and cyclic voltammetry (CV). This drug gave a well-defined voltammetric oxidation peak at + 1200 mV versus an Ag/AgCl reference electrode. The electrochemical oxidation process was shown to be irreversible and diffusion controlled, with adsorption characterized over the entire pH range. The optimized conditions, such as accumulation time and potential, scan rate, frequency, pulse amplitude, varying of working electrodes, and instrumental parameters were studied. The calibration graph for HCT was obtained from 4 × 10-6 to 4 × 10-5 M (correlation coefficient = 0.997) using the developed electroanalytical method (ASV). The detection limit of this drug was 4.3 × 10-9 M. ASV and CV techniques with adequate precision and accuracy have been developed and applied for direct determination of HCT in commercial tablets without separation or extraction procedures and biological fluids such as urine and plasma.
- 1 September 2014
- Published by The Journal of Food and Drug Analysis (JFDA), Food and Drug Administration, Taiwan (TFDA) in Journal of Food and Drug Analysis
- Vol. 22 (3) , 363-369
Open AccessElectrochemical oxidation behavior of hydrochlorothiazide on a glassy carbon electrode and its voltammetric determination in pharmaceutical formulations and biological fluids
The electrochemical oxidation behavior of hydrochlorothiazide (HCT) on a glassy carbon as a working electrode was investigated in Britton-Robinson (B-R) buffer pH 3, by using anodic stripping voltammetry (ASV) and cyclic voltammetry (CV). This drug gave a well-defined voltammetric oxidation peak at + 1200 mV versus an Ag/AgCl reference electrode. The electrochemical oxidation process was shown to be irreversible and diffusion controlled, with adsorption characterized over the entire pH range. The optimized conditions, such as accumulation time and potential, scan rate, frequency, pulse amplitude, varying of working electrodes, and instrumental parameters were studied. The calibration graph for HCT was obtained from 4 × 10-6 to 4 × 10-5 M (correlation coefficient = 0.997) using the developed electroanalytical method (ASV). The detection limit of this drug was 4.3 × 10-9 M. ASV and CV techniques with adequate precision and accuracy have been developed and applied for direct determination of HCT in commercial tablets without separation or extraction procedures and biological fluids such as urine and plasma.
- 26 April 2014
- Published by Pleiades Publishing Ltd in Russian Journal of Electrochemistry
- Vol. 50 (4) , 355-362
Electrochemical reduction of ciprofloxacin at the mercury electrode and its voltammetric determination in tablet and urine
In this study a reduction square wave voltammetric method was developed and validated for the direct determination of ciprofloxacin (CIP) in pharmaceutical formulation and biological fluid using hanging mercury dropping electrode (HMDE) surface. Best results were obtained for the quantitative determination of CIP in 0.02 M Britton-Robinson buffer at pH 2.5 and at a potential of −1300 mV vs. Ag/AgCl reference electrode. Various experimental and instrumental parameters affecting the peak current and potential of CIP electrochemical reduction were investigated and optimized. The monitored peak current was directly proportional to the concentration of CIP, where it exhibited a linear response in the range 3.0 × 10−7–2 × 10−6 M (r = 0.99). The accuracy of the proposed method was concluded based on the value of mean recovery of 98 ± 0.72 % with RSD of 0.181 % at a detection limit of 7 × 10−9 M. Possible interferences by various substances usually present in pharmaceutical formulations have been also evaluated. After validating the proposed method, the applicability of this voltammetric method was demonstrated by estimating CIP in its pharmaceutical formulation and spiked human urine, where values of mean recoveries of 97 ± 1.0% and 108.0 ± 2.0% were obtained, respectively.
- 26 April 2014
- Published by Pleiades Publishing Ltd in Russian Journal of Electrochemistry
- Vol. 50 (4) , 355-362
Electrochemical reduction of ciprofloxacin at the mercury electrode and its voltammetric determination in tablet and urine
In this study a reduction square wave voltammetric method was developed and validated for the direct determination of ciprofloxacin (CIP) in pharmaceutical formulation and biological fluid using hanging mercury dropping electrode (HMDE) surface. Best results were obtained for the quantitative determination of CIP in 0.02 M Britton-Robinson buffer at pH 2.5 and at a potential of −1300 mV vs. Ag/AgCl reference electrode. Various experimental and instrumental parameters affecting the peak current and potential of CIP electrochemical reduction were investigated and optimized. The monitored peak current was directly proportional to the concentration of CIP, where it exhibited a linear response in the range 3.0 × 10−7–2 × 10−6 M (r = 0.99). The accuracy of the proposed method was concluded based on the value of mean recovery of 98 ± 0.72 % with RSD of 0.181 % at a detection limit of 7 × 10−9 M. Possible interferences by various substances usually present in pharmaceutical formulations have been also evaluated. After validating the proposed method, the applicability of this voltammetric method was demonstrated by estimating CIP in its pharmaceutical formulation and spiked human urine, where values of mean recoveries of 97 ± 1.0% and 108.0 ± 2.0% were obtained, respectively.
- Open Access
- 21 February 2012
- Published by Springer Nature in BMC Chemistry
- Vol. 6 (1) , 15
Development of square-wave adsorptive stripping voltammetric method for determination of acebutolol in pharmaceutical formulations and biological fluids
A validated simple, rapid, sensitive and specific square-wave voltammetric technique is described for the determination of acebutolol (AC) following its accumulation onto a hanging mercury drop electrode in a Britton-Robinson universal buffer of pH 7.5. The optimal procedural conditions were: accumulation potential Eacc = - 0.8 V versus Ag/AgCl/KCl, accumulation duration tacc = 30 s, pulse-amplitude = 70 mV, scan rate = 100 mV/s, frequency = 30 Hz, surface area of the working electrode = 0.6 mm2 and the convection rate = 2000 rpm. Under these optimized conditions, the adsorptive stripping voltammetry (AdSV) peak current was proportional over the concentration range 5 × 10-7 - 6 × 10-6 M (r = 0.999). Recoveries for acebutolol from human plasma and urine were in the range 97-103% and 96-104% respectively. The method proved to be precise (intra-day precision expressed as %RSD in human plasma ranged from 2.9 - 3.2% and inter-day precision expressed as %RSD ranged from 3.4 - 3.8%) and accurate (intra-day accuracies expressed as % error in human urine ranged from -3.3 - 2.8% and inter-day accuracies ranged from -3.3 - 1.7%). The limit of quantitation (LOQ) and limit of detection (LOD) for acebutolol were 1.7 × 10-7 and 5 × 10-7 M, respectively. Possible interferences by substances usually present in the pharmaceutical formulations were investigated with a mean recovery of 101.6 ± 0.64%. Results of the developed square-wave adsorptive stripping voltammetry (SW-AdSV) method were comparable with those obtained by reference analytical method.
- 21 February 2012
- Published by Springer Nature in BMC Chemistry
- Vol. 6 (1) , 15
Open AccessDevelopment of square-wave adsorptive stripping voltammetric method for determination of acebutolol in pharmaceutical formulations and biological fluids
A validated simple, rapid, sensitive and specific square-wave voltammetric technique is described for the determination of acebutolol (AC) following its accumulation onto a hanging mercury drop electrode in a Britton-Robinson universal buffer of pH 7.5. The optimal procedural conditions were: accumulation potential Eacc = - 0.8 V versus Ag/AgCl/KCl, accumulation duration tacc = 30 s, pulse-amplitude = 70 mV, scan rate = 100 mV/s, frequency = 30 Hz, surface area of the working electrode = 0.6 mm2 and the convection rate = 2000 rpm. Under these optimized conditions, the adsorptive stripping voltammetry (AdSV) peak current was proportional over the concentration range 5 × 10-7 - 6 × 10-6 M (r = 0.999). Recoveries for acebutolol from human plasma and urine were in the range 97-103% and 96-104% respectively. The method proved to be precise (intra-day precision expressed as %RSD in human plasma ranged from 2.9 - 3.2% and inter-day precision expressed as %RSD ranged from 3.4 - 3.8%) and accurate (intra-day accuracies expressed as % error in human urine ranged from -3.3 - 2.8% and inter-day accuracies ranged from -3.3 - 1.7%). The limit of quantitation (LOQ) and limit of detection (LOD) for acebutolol were 1.7 × 10-7 and 5 × 10-7 M, respectively. Possible interferences by substances usually present in the pharmaceutical formulations were investigated with a mean recovery of 101.6 ± 0.64%. Results of the developed square-wave adsorptive stripping voltammetry (SW-AdSV) method were comparable with those obtained by reference analytical method.
- Open Access
- 1 November 2009
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 92 (6) , 1714-1719
A Square-Wave Adsorptive Stripping Voltammetric Method for Determination of Fast Green Dye
Square-wave adsorptive stripping voltammetric (SW-AdSV) determinations of trace concentrations of the coloring agent fast green were described. The analytical methodology used was based on the adsorptive preconcentration of the dye on the hanging mercury drop electrode, and then a negative sweep was initiated. In pH 10 carbonate supporting electrolyte, fast green gave a well-defined and sensitive SW-AdSV peak at 1220 mV. The electroanalytical determination of this dye was found to be optimized in carbonate buffer (pH 10) with the following experimental conditions: accumulation time (120 s); accumulation potential (0.8 V); scan rate (800 mV/s); pulse amplitude (90 mV); frequency (90 Hz); surface area of the working electrode (0.6 mm2); and the convection rate (2000 rpm). Under these optimized conditions, the AdSV peak current was proportional over the concentration range 2 1086 107 M (r = 0.999), with an LOD of 1.63 1010 M (0.132 ppb). This analytical approach possessed more enhanced sensitivity than conventional chromatography or spectrophotometry, and was simple and quick. The precision of the method in terms of RSD was 0.17, whereas the accuracy was evaluated via the mean recovery of 99.6. Possible interferences by several substances usually present as food additive azo dyes (E110, E102, E123, and E129), natural and artificial sweeteners, and antioxidants were also investigated. Applicability of the developed electroanalysis method was illustrated via the determination of fast green in ice cream and soft drink samples.
- 1 November 2009
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 92 (6) , 1714-1719
Open AccessA Square-Wave Adsorptive Stripping Voltammetric Method for Determination of Fast Green Dye
Square-wave adsorptive stripping voltammetric (SW-AdSV) determinations of trace concentrations of the coloring agent fast green were described. The analytical methodology used was based on the adsorptive preconcentration of the dye on the hanging mercury drop electrode, and then a negative sweep was initiated. In pH 10 carbonate supporting electrolyte, fast green gave a well-defined and sensitive SW-AdSV peak at 1220 mV. The electroanalytical determination of this dye was found to be optimized in carbonate buffer (pH 10) with the following experimental conditions: accumulation time (120 s); accumulation potential (0.8 V); scan rate (800 mV/s); pulse amplitude (90 mV); frequency (90 Hz); surface area of the working electrode (0.6 mm2); and the convection rate (2000 rpm). Under these optimized conditions, the AdSV peak current was proportional over the concentration range 2 1086 107 M (r = 0.999), with an LOD of 1.63 1010 M (0.132 ppb). This analytical approach possessed more enhanced sensitivity than conventional chromatography or spectrophotometry, and was simple and quick. The precision of the method in terms of RSD was 0.17, whereas the accuracy was evaluated via the mean recovery of 99.6. Possible interferences by several substances usually present as food additive azo dyes (E110, E102, E123, and E129), natural and artificial sweeteners, and antioxidants were also investigated. Applicability of the developed electroanalysis method was illustrated via the determination of fast green in ice cream and soft drink samples.