Adriano A. R. Barbosa
Adriano A. R. Barbosa has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Stelamaris R. Bertoli
School of Civil Engineering University of Campinas São Paulo State PO Box 6021 13083-970 Campinas City Brazil
2 shared publicationsA.L.B. Bergamo
1 shared publicationAgapito da Costa
Centro da Saúde, Kiu Manteko, Oecusse, Timor-Leste
1 shared publicationAnthony Dk Draper
Centre for Disease Control, Northern Territory Government Department of Health, Darwin, Australia
1 shared publicationAri Jayanti Pereira Tilman
Laboratorio Nacional de Saúde, Bidau, Timor-Leste
1 shared publicationC.S. Yung
1 shared publication
Latest Publications
- Open Access
- 2 May 2024
- Published by European Centre for Disease Control and Prevention (ECDC) in Eurosurveillance
- Vol. 29 (18) , 2400241
The first confirmed human case of rabies, Timor-Leste, 2024
In March 2024, the first ever human case of rabies, following a dog bite, was detected in Timor-Leste. This paper briefly discusses the circumstances of transmission, clinical presentation, palliative care of the case and public health measures taken. Timor-Leste was previously considered rabies-free. Any person who is bitten or scratched by an animal that could potentially transmit rabies virus (especially dogs, bats, monkeys or cats) in Timor-Leste should be assessed for consideration of provision of rabies post-exposure prophylaxis.
- 2 May 2024
- Published by European Centre for Disease Control and Prevention (ECDC) in Eurosurveillance
- Vol. 29 (18) , 2400241
Open AccessThe first confirmed human case of rabies, Timor-Leste, 2024
In March 2024, the first ever human case of rabies, following a dog bite, was detected in Timor-Leste. This paper briefly discusses the circumstances of transmission, clinical presentation, palliative care of the case and public health measures taken. Timor-Leste was previously considered rabies-free. Any person who is bitten or scratched by an animal that could potentially transmit rabies virus (especially dogs, bats, monkeys or cats) in Timor-Leste should be assessed for consideration of provision of rabies post-exposure prophylaxis.
- Open Access
- 26 January 2017
- Published by Science and Education Publishing Co., Ltd. in American Journal of Civil Engineering and Architecture
- Vol. 5 (1) , 17-24
Noise Generated by Portable Saw in Different Construction Materials
As part of efforts to identify sources of noise pollution from construction, a methodology is developed here for the standardized assessment of noise from masonry saws, which are electric cutters that are commonly used in the industry. Such standardized assessments could aid the development of quieter machines and also of less disruptive and safer industrial practices. The proposed methodology compares the noise generated during cutting with that of free-running non-cutting equipment in accordance with ISO 3744:2010, which specifies methods of determining sound power levels of noise sources via measurement of sound pressure for an essentially free field over a reflecting plane. The cutting of the proposed standard load (concrete slabs) and different building materials was louder than the disengaged saw. The highest observed sound power level was 110.1 dB. The smallest difference observed between the cutting and disengaged saw was 5.5 dB. Noise generated by the saw was quantitatively assessed. The results allowed a standard material to be proposed for use in tests determining the sound power levels of masonry saws. This study also contributes to the analysis of occupational noise generation, considering the difficulties in obtaining previously reported values of the sound spectrum of masonry saws.
- 26 January 2017
- Published by Science and Education Publishing Co., Ltd. in American Journal of Civil Engineering and Architecture
- Vol. 5 (1) , 17-24
Open AccessNoise Generated by Portable Saw in Different Construction Materials
As part of efforts to identify sources of noise pollution from construction, a methodology is developed here for the standardized assessment of noise from masonry saws, which are electric cutters that are commonly used in the industry. Such standardized assessments could aid the development of quieter machines and also of less disruptive and safer industrial practices. The proposed methodology compares the noise generated during cutting with that of free-running non-cutting equipment in accordance with ISO 3744:2010, which specifies methods of determining sound power levels of noise sources via measurement of sound pressure for an essentially free field over a reflecting plane. The cutting of the proposed standard load (concrete slabs) and different building materials was louder than the disengaged saw. The highest observed sound power level was 110.1 dB. The smallest difference observed between the cutting and disengaged saw was 5.5 dB. Noise generated by the saw was quantitatively assessed. The results allowed a standard material to be proposed for use in tests determining the sound power levels of masonry saws. This study also contributes to the analysis of occupational noise generation, considering the difficulties in obtaining previously reported values of the sound spectrum of masonry saws.
- 1 January 2017
- Published by Science and Education Publishing Co., Ltd. in Journal of Environment Pollution and Human Health
- Vol. 5 (2) , 30-35
Occupational Noise Exposure to Masonry Saw Cutting Materials
Despite a widespread recognition of the impacts of noise on hearing and other aspects of health, noise exposure in industry remains a significant problem, especially in the construction industry where noise exposure levels of workers are high, especially due to the use of manual equipment and machines used in constructions sites. The masonry saw is a portable power tool widely used in construction in small cuts and finishes for floors, tiles, bricks and woods. It stands out for versatility, lightness and its ergonomics. As part of efforts to identify sources of noise pollution from construction, a noise exposure is developed here for the occupational assessment from masonry saws, which are electric cutters that are commonly used in the industry. Different building materials commonly used in Brazil are used with the masonry saw in their conditions of loading and operation. The proposed methodology evaluates the noise generated during cutting with equipment in accordance with ISO 3744:2010 which specifies methods of measuring sound pressure levels on a surface enveloping the noise source in an environment that approximates an acoustic free field over a reflecting plane and the standard ISO 9612:2009 which specifies an engineering method for measuring workers' exposure to noise in a working environment and calculating the noise exposure level. The cutting of different building materials was louder than the disengaged saw. The highest observed sound pressure level was 106.9 dB(A) at operator ear and 99.1 dB(A) at 2 meters from the source. The smallest difference observed between the cutting and disengaged saw was 7.8 dB(A). Noise generated by the saw was quantitatively assessed. An occupational analysis illustrates that the sound levels generated in operations exceeded the tolerances permitted without protection. The subject is relevant to anticipating risks in the workplace in activities with the masonry saw cutting various building materials. Noise excess removal in the workplace is not just a legal responsibility of the companies, as it is also involved with the market interests of an organization. The safer and healthier a workplace is, the fewer probabilities of absenteeism, accidents and low performance, and consequently, cost savings will be achieved. This study also contributes to the analysis of occupational noise generation, considering the difficulties in obtaining previously reported values of the sound spectrum of masonry saws.
- 1 January 2017
- Published by Science and Education Publishing Co., Ltd. in Journal of Environment Pollution and Human Health
- Vol. 5 (2) , 30-35
Occupational Noise Exposure to Masonry Saw Cutting Materials
Despite a widespread recognition of the impacts of noise on hearing and other aspects of health, noise exposure in industry remains a significant problem, especially in the construction industry where noise exposure levels of workers are high, especially due to the use of manual equipment and machines used in constructions sites. The masonry saw is a portable power tool widely used in construction in small cuts and finishes for floors, tiles, bricks and woods. It stands out for versatility, lightness and its ergonomics. As part of efforts to identify sources of noise pollution from construction, a noise exposure is developed here for the occupational assessment from masonry saws, which are electric cutters that are commonly used in the industry. Different building materials commonly used in Brazil are used with the masonry saw in their conditions of loading and operation. The proposed methodology evaluates the noise generated during cutting with equipment in accordance with ISO 3744:2010 which specifies methods of measuring sound pressure levels on a surface enveloping the noise source in an environment that approximates an acoustic free field over a reflecting plane and the standard ISO 9612:2009 which specifies an engineering method for measuring workers' exposure to noise in a working environment and calculating the noise exposure level. The cutting of different building materials was louder than the disengaged saw. The highest observed sound pressure level was 106.9 dB(A) at operator ear and 99.1 dB(A) at 2 meters from the source. The smallest difference observed between the cutting and disengaged saw was 7.8 dB(A). Noise generated by the saw was quantitatively assessed. An occupational analysis illustrates that the sound levels generated in operations exceeded the tolerances permitted without protection. The subject is relevant to anticipating risks in the workplace in activities with the masonry saw cutting various building materials. Noise excess removal in the workplace is not just a legal responsibility of the companies, as it is also involved with the market interests of an organization. The safer and healthier a workplace is, the fewer probabilities of absenteeism, accidents and low performance, and consequently, cost savings will be achieved. This study also contributes to the analysis of occupational noise generation, considering the difficulties in obtaining previously reported values of the sound spectrum of masonry saws.
- Open Access
- 1 January 2017
- Published by University of Latvia
- p. 8-18
Productivity & Innovation as a Support in Project Management: A Study Through Construction Industry in Brazil
- 1 January 2017
- Published by University of Latvia
- p. 8-18
Open AccessProductivity & Innovation as a Support in Project Management: A Study Through Construction Industry in Brazil
- 20 January 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 58-67
Retuning stabilizers for the north-south Brazilian interconnection
- 20 January 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 58-67
Retuning stabilizers for the north-south Brazilian interconnection