Sankha Banerjee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sankha Banerjee has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
Shaestagir Chowdhury
5 shared publicationsK. A. Cook-Chennault
4 shared publicationsSaquib Ahmed
Department of Mechanical Engineering Technology State University of New York—Buffalo State Buffalo NY USA
4 shared publications- Saquib Ahmed
Department of Mechanical Engineering Technology, SUNY Buffalo State University, Buffalo, USA; Center for Integrated Studies in Nanoscience and Nanotechnology, SUNY Buffalo State University, Buffalo, USA
4 shared publications Jalen Harris
Department of Mechanical Engineering, California State University – Fresno, Fresno, California 93740, USA
3 shared publicationsJon Shaffer
Department of Mechanical Engineering Technology, SUNY – Buffalo State, Buffalo, New York 14222, USA
3 shared publications
Latest Publications
- 10 February 2021
- Published by Wiley in Water Environment Research
- Vol. 93 (9) , 1530-1542
Fabrication and characterization of a water purification system using activated carbon and graphene nanoplatelets: Toward the development of a nanofiltration matrix
Researchers are trying to tackle water scarcity in numerous ways. One of those ways is the use of nanotechnology in water processing and purification. The current work involves the fabrication and optimization of activated carbon and graphene‐based hybrid water purification system. Five different concentrations of methylene blue and deionized water (DI) water dye solutions were used, and they were filtered in three different cycles. For the potential usage on the consumer side, a small‐scale, low‐cost water filter is developed using activated carbon, commercial filter paper, and graphene nanoplatelets. The filter paper is used to hold mixtures of the activated carbon and graphene nanoplatelets within the water filter. The conductivity, TDS, and pH are measured for the feed water and the processed water using an Oakton EcoTestr and Apera Instruments PH60 Premium Pocket pH meter respectively. A UV‐Vis spectrometer is used to measure the absorption of solutions. The distribution and adsorption of the dye particles were observed by scanning electron microscopy.
- 10 February 2021
- Published by Wiley in Water Environment Research
- Vol. 93 (9) , 1530-1542
Fabrication and characterization of a water purification system using activated carbon and graphene nanoplatelets: Toward the development of a nanofiltration matrix
Researchers are trying to tackle water scarcity in numerous ways. One of those ways is the use of nanotechnology in water processing and purification. The current work involves the fabrication and optimization of activated carbon and graphene‐based hybrid water purification system. Five different concentrations of methylene blue and deionized water (DI) water dye solutions were used, and they were filtered in three different cycles. For the potential usage on the consumer side, a small‐scale, low‐cost water filter is developed using activated carbon, commercial filter paper, and graphene nanoplatelets. The filter paper is used to hold mixtures of the activated carbon and graphene nanoplatelets within the water filter. The conductivity, TDS, and pH are measured for the feed water and the processed water using an Oakton EcoTestr and Apera Instruments PH60 Premium Pocket pH meter respectively. A UV‐Vis spectrometer is used to measure the absorption of solutions. The distribution and adsorption of the dye particles were observed by scanning electron microscopy.
- Open Access
- 19 September 2020
- Published by MDPI AG in Journal of Composites Science
- Vol. 4 (3) , 141
Polarization Parameters and Scaling Matter—How Processing Environment and Shape Factor Influence Electroactive Nanocomposite Characteristics
Polymeric-ceramic smart nanocomposite piezoelectric and dielectric materials are of interest due to their superior mechanical flexibility and ability to leverage characteristics of constituent materials. A great deal of work has centered on development of processes for manufacturing 0–3 continuity composite piezoelectric materials that vary in scale ranging from bulk, thick and thin film to nanostructured films. Less is known about how material scaling effects the effectiveness of polarization and electromechanical properties. This study elucidates how polarization parameters: contact versus corona, temperature and electrical voltage field influence the piezoelectric and dielectric properties of samples as a function of their shape factor, i.e., bulk versus thick film. Bulk and thick film samples were prepared via sol gel/cast-mold and sol gel/spin coat deposition, for fabrication of bulk and thick films, respectively. It was found that corona polarization was more effective for both bulk and thick film processes and that polarization temperature produced higher normalized changes in samples. Although higher electric field voltages could be achieved with thicker samples, film samples responded the most to coupled increases in temperature and electrical voltage than bulk samples.
- 19 September 2020
- Published by MDPI AG in Journal of Composites Science
- Vol. 4 (3) , 141
Open AccessPolarization Parameters and Scaling Matter—How Processing Environment and Shape Factor Influence Electroactive Nanocomposite Characteristics
Polymeric-ceramic smart nanocomposite piezoelectric and dielectric materials are of interest due to their superior mechanical flexibility and ability to leverage characteristics of constituent materials. A great deal of work has centered on development of processes for manufacturing 0–3 continuity composite piezoelectric materials that vary in scale ranging from bulk, thick and thin film to nanostructured films. Less is known about how material scaling effects the effectiveness of polarization and electromechanical properties. This study elucidates how polarization parameters: contact versus corona, temperature and electrical voltage field influence the piezoelectric and dielectric properties of samples as a function of their shape factor, i.e., bulk versus thick film. Bulk and thick film samples were prepared via sol gel/cast-mold and sol gel/spin coat deposition, for fabrication of bulk and thick films, respectively. It was found that corona polarization was more effective for both bulk and thick film processes and that polarization temperature produced higher normalized changes in samples. Although higher electric field voltages could be achieved with thicker samples, film samples responded the most to coupled increases in temperature and electrical voltage than bulk samples.
- Open Access
- 4 July 2020
- Published by MDPI AG in Journal of Composites Science
- Vol. 4 (3) , 88
Fabrication and Characterization of Flexible Three-Phase ZnO-Graphene-Epoxy Electro-Active Thin-Film Nanocomposites: Towards Applications in Wearable Biomedical Devices
Perovskite oxides have been used as sensors, actuators, transducers, for sound generation and detection, and also in optical instruments and microscopes. Perovskite halides are currently considered as optoelectronic devices such as solar cells, photodetectors, and radiation detection, but there are major issues with stability, interfacial recombination, and electron/hole mobility. The following work looks into the fabrication of non-toxic ZnO-based lead-free alternatives to perovskite oxides for use as secondary sensors or electron transport layers along with perovskite halides for application in stacked biomedical wearable devices. Three-phase, lead-free, Zinc Oxide-Graphene-Epoxy electroactive nanocomposite thin films were fabricated. The volume fraction of the Graphene phase was held constant at 10%, while the volume fraction of the ZnO phase was varied from 10–70%. The dielectric constant, capacitance, impedance, resistance, and conductance of the samples were measured using an impedance analyzer, and the results were compared as a function of volume fraction of ZnO to understand the electron transport performance of these thin films. The impedance and dielectric spectra of the nanocomposites were recorded over a frequency range of 20 Hz to 10 MHz. The microstructural properties and cross-section of the thin films were analyzed using a Scanning Electron Microscope. The high sensitivity and electron transport properties of the composite could be potentially utilized in biomedical devices at low- and high-frequency ranges.
- 4 July 2020
- Published by MDPI AG in Journal of Composites Science
- Vol. 4 (3) , 88
Open AccessFabrication and Characterization of Flexible Three-Phase ZnO-Graphene-Epoxy Electro-Active Thin-Film Nanocomposites: Towards Applications in Wearable Biomedical Devices
Perovskite oxides have been used as sensors, actuators, transducers, for sound generation and detection, and also in optical instruments and microscopes. Perovskite halides are currently considered as optoelectronic devices such as solar cells, photodetectors, and radiation detection, but there are major issues with stability, interfacial recombination, and electron/hole mobility. The following work looks into the fabrication of non-toxic ZnO-based lead-free alternatives to perovskite oxides for use as secondary sensors or electron transport layers along with perovskite halides for application in stacked biomedical wearable devices. Three-phase, lead-free, Zinc Oxide-Graphene-Epoxy electroactive nanocomposite thin films were fabricated. The volume fraction of the Graphene phase was held constant at 10%, while the volume fraction of the ZnO phase was varied from 10–70%. The dielectric constant, capacitance, impedance, resistance, and conductance of the samples were measured using an impedance analyzer, and the results were compared as a function of volume fraction of ZnO to understand the electron transport performance of these thin films. The impedance and dielectric spectra of the nanocomposites were recorded over a frequency range of 20 Hz to 10 MHz. The microstructural properties and cross-section of the thin films were analyzed using a Scanning Electron Microscope. The high sensitivity and electron transport properties of the composite could be potentially utilized in biomedical devices at low- and high-frequency ranges.
- 1 July 2020
- Published by Elsevier in Optical Materials
- Vol. 105
Numerical simulation studies of a fully inorganic Cs2AgBiBr6 perovskite solar device
- 1 July 2020
- Published by Elsevier in Optical Materials
- Vol. 105
Numerical simulation studies of a fully inorganic Cs2AgBiBr6 perovskite solar device
- Open Access
- 9 December 2019
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 126 (22) , 223301
A rapid technique for the determination of secondary electron emission yield from complex surfaces
Plasma-wall interaction in the presence of secondary electron emission (SEE) can lead to a degradation and reduction in the performance of plasma devices. Materials with complex surface architectures such as velvet, fuzz, and feathered surfaces have a lower SEE yield than the same materials with a flat surface and can, therefore, be useful for plasma applications. This reduction in the SEE is due to the trapping of secondary electrons in the microcavities formed by complex surfaces. In this paper, we present a rapid method for a simultaneous comparison of the SEE yield and surface properties of materials with different surface architectures. The method uses Scanning Electron Microscopy to simultaneously evaluate the surface morphologies and SEE yield properties for a microarchitectured surface. This technique was applied to carbon velvets, and results show agreement with recent theoretical models and with the direct determination of the SEE yield from measurements of the currents of the primary electrons impinging the surface and of the secondary electrons emitted from the surface.
- 9 December 2019
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 126 (22) , 223301
Open AccessA rapid technique for the determination of secondary electron emission yield from complex surfaces
Plasma-wall interaction in the presence of secondary electron emission (SEE) can lead to a degradation and reduction in the performance of plasma devices. Materials with complex surface architectures such as velvet, fuzz, and feathered surfaces have a lower SEE yield than the same materials with a flat surface and can, therefore, be useful for plasma applications. This reduction in the SEE is due to the trapping of secondary electrons in the microcavities formed by complex surfaces. In this paper, we present a rapid method for a simultaneous comparison of the SEE yield and surface properties of materials with different surface architectures. The method uses Scanning Electron Microscopy to simultaneously evaluate the surface morphologies and SEE yield properties for a microarchitectured surface. This technique was applied to carbon velvets, and results show agreement with recent theoretical models and with the direct determination of the SEE yield from measurements of the currents of the primary electrons impinging the surface and of the secondary electrons emitted from the surface.
- 24 June 2019
- Published by Springer Nature in Journal of Materials Research
- Vol. 34 (16) , 2789-2795
Simulation studies of Sn-based perovskites with Cu back-contact for non-toxic and non-corrosive devices
- 24 June 2019
- Published by Springer Nature in Journal of Materials Research
- Vol. 34 (16) , 2789-2795
Simulation studies of Sn-based perovskites with Cu back-contact for non-toxic and non-corrosive devices