D. A. Matthijs de Winter
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
D. A. Matthijs de Winter has a total of 167 co-authors. Here are the top co-authors by number of shared publications:
- Martyn R. Drury
Department of Earth Sciences, Utrecht University, Utrecht, The Netherlands
11 shared publications - Bert Marc Weckhuysen
Utrecht University Universiteitsweg 99
6 shared publications - Christopher James Spiers
Department of Earth Sciences Utrecht University Utrecht The Netherlands
4 shared publications Jan A. Post
4 shared publicationsLukasz Karwacki
Inorganic Chemistry and Catalysis, Debye Institute for NanoMaterials Science, Utrecht University, Universiteitsweg 99, 3584 CG Utrecht (The Netherlands), Fax: (+31) 30‐251‐1027
4 shared publicationsA.J. Verkleij
3 shared publications
Latest Publications
- Open Access
- 2 May 2026
- Published by Elsevier in SSRN Electronic Journal
A Physiologically-Based Kinetic (PBK) Model for Exposure of Mammals to Nano- and Microparticles
Humans are exposed to nano- and microparticles (NMPs) via inhalation, ingestion and dermal contact, potentially adversely affecting human health. However, there currently is a lack of sufficient and reliable data to fully characterize the absorption, distribution, metabolism, and excretion (ADME) of NMPs in humans, and such understanding often relies on animal studies. Physiologically based kinetic (PBK) models provide a mechanistic framework to describe the biological internalization processes of chemicals; however, their application to nano- and micro-scale materials remains limited. In this study, we combined existing PBK frameworks with current knowledge about the absorption, distribution, and excretion of NMPs in mammals to construct a mammalian PBK model describing oral and inhalation exposure to nano- and micro-sized particles. Model calibration and validation were performed using nano- and microparticle data for mice (polystyrene particles varying from 500 nm to 5 μm) and rats (cerium oxide particles of 151 nm and 615.3 nm). Most estimations were within a 5-fold difference from measurements. Sensitivity analyses show that the faecal rate constant from the GIT lumen and the transport rate constant from lumen to blood are the most sensitive parameters. These parameters should therefore be carefully measured when extending PBK modeling to humans. We propose targeted human exposure experiments and a combination of mechanistic (estimating parameters as functions of organism and particle properties) and statistic approaches (e.g. Bayesian estimation) to parameterize a human PBK model and expanding the applicability domain to heterogeneous particles.
- 2 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessA Physiologically-Based Kinetic (PBK) Model for Exposure of Mammals to Nano- and Microparticles
Humans are exposed to nano- and microparticles (NMPs) via inhalation, ingestion and dermal contact, potentially adversely affecting human health. However, there currently is a lack of sufficient and reliable data to fully characterize the absorption, distribution, metabolism, and excretion (ADME) of NMPs in humans, and such understanding often relies on animal studies. Physiologically based kinetic (PBK) models provide a mechanistic framework to describe the biological internalization processes of chemicals; however, their application to nano- and micro-scale materials remains limited. In this study, we combined existing PBK frameworks with current knowledge about the absorption, distribution, and excretion of NMPs in mammals to construct a mammalian PBK model describing oral and inhalation exposure to nano- and micro-sized particles. Model calibration and validation were performed using nano- and microparticle data for mice (polystyrene particles varying from 500 nm to 5 μm) and rats (cerium oxide particles of 151 nm and 615.3 nm). Most estimations were within a 5-fold difference from measurements. Sensitivity analyses show that the faecal rate constant from the GIT lumen and the transport rate constant from lumen to blood are the most sensitive parameters. These parameters should therefore be carefully measured when extending PBK modeling to humans. We propose targeted human exposure experiments and a combination of mechanistic (estimating parameters as functions of organism and particle properties) and statistic approaches (e.g. Bayesian estimation) to parameterize a human PBK model and expanding the applicability domain to heterogeneous particles.
- Open Access
- 1 May 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (5)
Asymmetric aerosol volume transmission: A computational approach toward infection prevention efficiency of face masks
Wearing face masks is considered as one of the infection prevention and control options for respiratory viruses (e.g., SARS-CoV-2) that acts by blocking virus-laden aerosols. It is generally thought that aerosol blockage occurs when air passes through the face mask fabric. We calculated air flows through face masks and through peripheral leakages, based on reported breathing resistance values of face masks (FFP/N95, surgical masks, and cloth masks) and found that most of the inhaled and exhaled air passes through these peripheral leakages. Nevertheless, face masks remain effective as an infection prevention option, because additional calculations showed that the majority of aerosol volume cannot follow the tortuous path of air around the face mask. The filtering efficiency through the peripheral leakages can be described as a function of breathing conditions, vocal activities, the leakage geometry and tortuous pathway, aerosol properties (diameter, composition) and ambient conditions (e.g., evaporation, ventilation). Inclusion of these parameters explains the asymmetric filtering behavior of face masks, i.e., the risk of infection from person A to person B does not necessarily equal the risk of infection from person B to person A. Our findings explain thus why masking an infectious person is more effective than masking an exposed person. Establishing that the tortuous pathway of air around the face mask is the sole contributor to face mask efficiency opens new opportunities for designing safer face masks.
- 1 May 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (5)
Open AccessAsymmetric aerosol volume transmission: A computational approach toward infection prevention efficiency of face masks
Wearing face masks is considered as one of the infection prevention and control options for respiratory viruses (e.g., SARS-CoV-2) that acts by blocking virus-laden aerosols. It is generally thought that aerosol blockage occurs when air passes through the face mask fabric. We calculated air flows through face masks and through peripheral leakages, based on reported breathing resistance values of face masks (FFP/N95, surgical masks, and cloth masks) and found that most of the inhaled and exhaled air passes through these peripheral leakages. Nevertheless, face masks remain effective as an infection prevention option, because additional calculations showed that the majority of aerosol volume cannot follow the tortuous path of air around the face mask. The filtering efficiency through the peripheral leakages can be described as a function of breathing conditions, vocal activities, the leakage geometry and tortuous pathway, aerosol properties (diameter, composition) and ambient conditions (e.g., evaporation, ventilation). Inclusion of these parameters explains the asymmetric filtering behavior of face masks, i.e., the risk of infection from person A to person B does not necessarily equal the risk of infection from person B to person A. Our findings explain thus why masking an infectious person is more effective than masking an exposed person. Establishing that the tortuous pathway of air around the face mask is the sole contributor to face mask efficiency opens new opportunities for designing safer face masks.
- Open Access
- 12 August 2021
- Published by Springer Nature in Communications Biology
- Vol. 4 (1) , 1-2
Publisher Correction: 3D test sample for the calibration and quality control of stimulated emission depletion (STED) and confocal microscopes
- 12 August 2021
- Published by Springer Nature in Communications Biology
- Vol. 4 (1) , 1-2
Open AccessPublisher Correction: 3D test sample for the calibration and quality control of stimulated emission depletion (STED) and confocal microscopes
- 22 January 2021
- Published by Wiley in Journal of Microscopy
- Vol. 281 (2) , 109-111
Cryo‐focussed ion beam in Life Sciences (and beyond)
- 22 January 2021
- Published by Wiley in Journal of Microscopy
- Vol. 281 (2) , 109-111
Cryo‐focussed ion beam in Life Sciences (and beyond)
- Open Access
- 27 November 2020
- Published by Springer Nature in Transport in Porous Media
- Vol. 136 (1) , 343-367
The Complexity of Porous Media Flow Characterized in a Microfluidic Model Based on Confocal Laser Scanning Microscopy and Micro-PIV
In this study, the complexity of a steady-state flow through porous media is revealed using confocal laser scanning microscopy (CLSM). Micro-particle image velocimetry (micro-PIV) is applied to construct movies of colloidal particles. The calculated velocity vector fields from images are further utilized to obtain laminar flow streamlines. Fluid flow through a single straight channel is used to confirm that quantitative CLSM measurements can be conducted. Next, the coupling between the flow in a channel and the movement within an intersecting dead-end region is studied. Quantitative CLSM measurements confirm the numerically determined coupling parameter from earlier work of the authors. The fluid flow complexity is demonstrated using a porous medium consisting of a regular grid of pores in contact with a flowing fluid channel. The porous media structure was further used as the simulation domain for numerical modeling. Both the simulation, based on solving Stokes equations, and the experimental data show presence of non-trivial streamline trajectories across the pore structures. In view of the results, we argue that the hydrodynamic mixing is a combination of non-trivial streamline routing and Brownian motion by pore-scale diffusion. The results provide insight into challenges in upscaling hydrodynamic dispersion from pore scale to representative elementary volume (REV) scale. Furthermore, the successful quantitative validation of CLSM-based data from a microfluidic model fed by an electrical syringe pump provided a valuable benchmark for qualitative validation of computer simulation results. Graphic
- 27 November 2020
- Published by Springer Nature in Transport in Porous Media
- Vol. 136 (1) , 343-367
Open AccessThe Complexity of Porous Media Flow Characterized in a Microfluidic Model Based on Confocal Laser Scanning Microscopy and Micro-PIV
In this study, the complexity of a steady-state flow through porous media is revealed using confocal laser scanning microscopy (CLSM). Micro-particle image velocimetry (micro-PIV) is applied to construct movies of colloidal particles. The calculated velocity vector fields from images are further utilized to obtain laminar flow streamlines. Fluid flow through a single straight channel is used to confirm that quantitative CLSM measurements can be conducted. Next, the coupling between the flow in a channel and the movement within an intersecting dead-end region is studied. Quantitative CLSM measurements confirm the numerically determined coupling parameter from earlier work of the authors. The fluid flow complexity is demonstrated using a porous medium consisting of a regular grid of pores in contact with a flowing fluid channel. The porous media structure was further used as the simulation domain for numerical modeling. Both the simulation, based on solving Stokes equations, and the experimental data show presence of non-trivial streamline trajectories across the pore structures. In view of the results, we argue that the hydrodynamic mixing is a combination of non-trivial streamline routing and Brownian motion by pore-scale diffusion. The results provide insight into challenges in upscaling hydrodynamic dispersion from pore scale to representative elementary volume (REV) scale. Furthermore, the successful quantitative validation of CLSM-based data from a microfluidic model fed by an electrical syringe pump provided a valuable benchmark for qualitative validation of computer simulation results. Graphic
- Open Access
3D test sample for the calibration and quality control of super-resolution and confocal microscopes
A multitude of samples is required to monitor and optimize the quality and reliability of quantitative measurements of (super-resolution) light microscopes. Here, we present a single sample to calibrate microscopes, align their laser beams and measure their point spread function (PSF) in 3D. The sample is composed of a refractive index matched colloidal crystal of silica beads with fluorescent and gold cores. The microscope can be calibrated in three dimensions using the periodicity of the crystal; the alignment of the laser beams can be checked using the reflection of the gold cores; and the PSF can be measured at multiple positions and depths using the fluorescent cores. It is demonstrated how this sample can be used to visualize and improve the quality of confocal and super-resolution images. The sample is adjustable to meet the requirements of different NA objectives and microscopy techniques and additionally can be used to evaluate refractive index mismatches as a function of depth quantitatively.
Open Access3D test sample for the calibration and quality control of super-resolution and confocal microscopes
A multitude of samples is required to monitor and optimize the quality and reliability of quantitative measurements of (super-resolution) light microscopes. Here, we present a single sample to calibrate microscopes, align their laser beams and measure their point spread function (PSF) in 3D. The sample is composed of a refractive index matched colloidal crystal of silica beads with fluorescent and gold cores. The microscope can be calibrated in three dimensions using the periodicity of the crystal; the alignment of the laser beams can be checked using the reflection of the gold cores; and the PSF can be measured at multiple positions and depths using the fluorescent cores. It is demonstrated how this sample can be used to visualize and improve the quality of confocal and super-resolution images. The sample is adjustable to meet the requirements of different NA objectives and microscopy techniques and additionally can be used to evaluate refractive index mismatches as a function of depth quantitatively.
- Open Access
- 31 July 2020
- Published by Wiley in Journal of Microscopy
- Vol. 281 (2) , 138-156
An introduction to cryo‐FIB‐SEM cross‐sectioning of frozen, hydrated Life Science samples
Summary: The introduction of cryo‐techniques to the focused ion‐beam scanning electron microscope (FIB‐SEM) has brought new opportunities to study frozen, hydrated samples from the field of Life Sciences. Cryo‐techniques have long been employed in electron microscopy. Thin electron transparent sections are produced by cryo‐ultramicrotomy for observation in a cryo‐transmission electron microscope (TEM). Cryo‐TEM is presently reaching the imaging of macromolecular structures. In parallel, cryo‐fractured surfaces from bulk materials have been investigated by cryo‐SEM.Both cryo‐TEM and cryo‐SEM have provided a wealth of information, despite being 2D techniques. Cryo‐TEM tomography does provide 3D information, but the thickness of the volume has a maximum of 200–300 nm, which limits the 3D information within the context of specific structures. FIB‐milling enables imaging additional planes by creating cross‐sections (e.g. cross‐sectioning or site‐specific X‐sectioning) perpendicular to the cryo‐fracture surface, thus adding a third imaging dimension to the cryo‐SEM. This paper discusses how to produce suitable cryo‐FIB‐SEM cross‐section results from frozen, hydrated Life Science samples with emphasis on ‘common knowledge’ and reoccurring observations.Lay Description: Life Sciences studies life down to the smallest details. Visualising the smallest details requires electron microscopy, which utilises high‐vacuum chambers. One method to maintain the integrity of Life Sciences samples under vacuum conditions is freezing. Frozen samples can remain in a suspended state. As a result, research can be carried out without having to change the chemistry or internal physical structure of the samples.Two types of electron microscopes equipped with cryo‐sample handling facilities are used to investigate samples: The scanning electron microscope (SEM) which investigates surfaces and the transmission electron microscope (TEM) which investigates thin electron transparent sections (called lamellae). A third method of investigation combines a SEM with a focused ion beam (FIB) to form a cryo‐FIB‐SEM, which is the basis of this paper. The electron beam images the cryo‐sample surface while the ion beam mills into the surface to expose the interior of the sample. The latter is called cross‐sectioning and the result provides a way of investigating the 3rd dimension of the sample. This paper looks at the making of cross‐sections in this manner originating from knowledge and experience gained with this technique over many years. This information is meant for newcomers, and experienced researchers in cryo‐microscopy alike.
- 31 July 2020
- Published by Wiley in Journal of Microscopy
- Vol. 281 (2) , 138-156
Open AccessAn introduction to cryo‐FIB‐SEM cross‐sectioning of frozen, hydrated Life Science samples
Summary: The introduction of cryo‐techniques to the focused ion‐beam scanning electron microscope (FIB‐SEM) has brought new opportunities to study frozen, hydrated samples from the field of Life Sciences. Cryo‐techniques have long been employed in electron microscopy. Thin electron transparent sections are produced by cryo‐ultramicrotomy for observation in a cryo‐transmission electron microscope (TEM). Cryo‐TEM is presently reaching the imaging of macromolecular structures. In parallel, cryo‐fractured surfaces from bulk materials have been investigated by cryo‐SEM.Both cryo‐TEM and cryo‐SEM have provided a wealth of information, despite being 2D techniques. Cryo‐TEM tomography does provide 3D information, but the thickness of the volume has a maximum of 200–300 nm, which limits the 3D information within the context of specific structures. FIB‐milling enables imaging additional planes by creating cross‐sections (e.g. cross‐sectioning or site‐specific X‐sectioning) perpendicular to the cryo‐fracture surface, thus adding a third imaging dimension to the cryo‐SEM. This paper discusses how to produce suitable cryo‐FIB‐SEM cross‐section results from frozen, hydrated Life Science samples with emphasis on ‘common knowledge’ and reoccurring observations.Lay Description: Life Sciences studies life down to the smallest details. Visualising the smallest details requires electron microscopy, which utilises high‐vacuum chambers. One method to maintain the integrity of Life Sciences samples under vacuum conditions is freezing. Frozen samples can remain in a suspended state. As a result, research can be carried out without having to change the chemistry or internal physical structure of the samples.Two types of electron microscopes equipped with cryo‐sample handling facilities are used to investigate samples: The scanning electron microscope (SEM) which investigates surfaces and the transmission electron microscope (TEM) which investigates thin electron transparent sections (called lamellae). A third method of investigation combines a SEM with a focused ion beam (FIB) to form a cryo‐FIB‐SEM, which is the basis of this paper. The electron beam images the cryo‐sample surface while the ion beam mills into the surface to expose the interior of the sample. The latter is called cross‐sectioning and the result provides a way of investigating the 3rd dimension of the sample. This paper looks at the making of cross‐sections in this manner originating from knowledge and experience gained with this technique over many years. This information is meant for newcomers, and experienced researchers in cryo‐microscopy alike.
- Open Access
- 21 July 2020
- Published by Wiley in Journal of Microscopy
- Vol. 281 (2) , 125-137
Cryo‐FIB preparation of whole cells and tissue for cryo‐TEM: use of high‐pressure frozen specimens in tubes and planchets
Summary: The desire to study macromolecular complexes within their cellular context requires the ability to produce thin samples suitable for cryo‐TEM (cryo‐transmission electron microscope) investigations. In this paper, we discuss two similar approaches, which were developed independently in Utrecht (the Netherlands) and Albany (USA). The methods are particularly suitable for both tissue samples and cell suspensions prepared by a high‐pressure freezer (HPF). The workflows are explained with particular attention to potential pitfalls, while underlying principles are highlighted (‘why to do so’). Although both workflows function with a high success rate, full execution requires considerable experience and remains demanding. In addition, throughput is low. We hope to encourage other research groups worldwide to take on the challenge of improving the HPF– cryo‐FIB‐SEM – cryo‐TEM workflow. We discuss a number of suggestions to this end.Lay Description: Life is ultimately dictated by the interaction of molecules in our bodies. Highly complex equipment is being used and further developed to study these interactions. The present paper describes methods to prepare small, very thin lamellae (area of 5×5 µm2, thickness 50–300 nm) of a cell to be studied in a cryo‐transmission electron microscope (cryo‐TEM). Special care must be taken to preserve the natural state of molecules in their natural environment. In the case of cryo‐TEM, the samples must be frozen and kept frozen to be compatible with the vacuum conditions in the microscope. The frozen condition imposes technical challenges which are addressed. Two approaches to obtain the thin lamellae are described. Both make use of a focused ion beam (FIB) microscope. The FIB allows removal of material with nanometre precision by focusing a beam of ionised atoms (gallium ions) onto the sample. Careful control of the FIB allows cutting out of the required thin lamellae. In both strategies, the thin lamellae remain attached to the original sample, and the ensemble of sample with section and sample holder is transported from the FIB microscope to the TEM while being kept frozen.
- 21 July 2020
- Published by Wiley in Journal of Microscopy
- Vol. 281 (2) , 125-137
Open AccessCryo‐FIB preparation of whole cells and tissue for cryo‐TEM: use of high‐pressure frozen specimens in tubes and planchets
Summary: The desire to study macromolecular complexes within their cellular context requires the ability to produce thin samples suitable for cryo‐TEM (cryo‐transmission electron microscope) investigations. In this paper, we discuss two similar approaches, which were developed independently in Utrecht (the Netherlands) and Albany (USA). The methods are particularly suitable for both tissue samples and cell suspensions prepared by a high‐pressure freezer (HPF). The workflows are explained with particular attention to potential pitfalls, while underlying principles are highlighted (‘why to do so’). Although both workflows function with a high success rate, full execution requires considerable experience and remains demanding. In addition, throughput is low. We hope to encourage other research groups worldwide to take on the challenge of improving the HPF– cryo‐FIB‐SEM – cryo‐TEM workflow. We discuss a number of suggestions to this end.Lay Description: Life is ultimately dictated by the interaction of molecules in our bodies. Highly complex equipment is being used and further developed to study these interactions. The present paper describes methods to prepare small, very thin lamellae (area of 5×5 µm2, thickness 50–300 nm) of a cell to be studied in a cryo‐transmission electron microscope (cryo‐TEM). Special care must be taken to preserve the natural state of molecules in their natural environment. In the case of cryo‐TEM, the samples must be frozen and kept frozen to be compatible with the vacuum conditions in the microscope. The frozen condition imposes technical challenges which are addressed. Two approaches to obtain the thin lamellae are described. Both make use of a focused ion beam (FIB) microscope. The FIB allows removal of material with nanometre precision by focusing a beam of ionised atoms (gallium ions) onto the sample. Careful control of the FIB allows cutting out of the required thin lamellae. In both strategies, the thin lamellae remain attached to the original sample, and the ensemble of sample with section and sample holder is transported from the FIB microscope to the TEM while being kept frozen.
- Open Access
- 1 April 2017
- Published by Elsevier in International Journal of Coal Geology
- Vol. 175, 26-39
Fluid flow from matrix to fractures in Early Jurassic shales
- 1 April 2017
- Published by Elsevier in International Journal of Coal Geology
- Vol. 175, 26-39
Open AccessFluid flow from matrix to fractures in Early Jurassic shales
- Open Access
- 1 March 2017
- Published by Elsevier in Chemical Engineering Science
- Vol. 160, 275-280
Characterizing the hydraulic properties of paper coating layer using FIB-SEM tomography and 3D pore-scale modeling
- 1 March 2017
- Published by Elsevier in Chemical Engineering Science
- Vol. 160, 275-280
Open AccessCharacterizing the hydraulic properties of paper coating layer using FIB-SEM tomography and 3D pore-scale modeling