Seda Aslan Kilavuz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Seda Aslan Kilavuz has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Zehra Bozkurt
Duzce Universitesi
2 shared publications Aykan Karademir
University of Kocaeli
1 shared publication- Daniel Wang
Divisions of Cardiology, Department of Medicine, David Geffen School of Medicine at UCLA, University of California, Los Angeles, Los Angeles, California
1 shared publication Deniz Karman
Department of Civil and Environmental Engineering , Carleton University , Ottawa , Ontario , Canada
1 shared publicationErtan Durmusoglu
University of Kocaeli
1 shared publication- Fatih Taşpınar
Düzce University
1 shared publication
Latest Publications
- Open Access
- 14 January 2022
- Published by Dogal Afetler ve Cevre Dergisi in Doğal Afetler ve Çevre Dergisi
- Vol. 8 (1) , 53-65
Düzce İlinde İlkokulların İç ve Dış Ortamlarındaki Toz Örneklerinde PCB Düzeylerinin Belirlenmesi
Düzce province, where industry, traffic and residential areas are intertwined, is developing rapidly and therefore environmental pollution is intensely felt in the region. Air pollutants from emission sources cannot be dispersed due to the geographical location of the province and pose important health risks. In this study, dust samples were collected at different locations in order to explain the regional pollution distribution and various emission sources. Because children are more sensitive to air pollutants, indoor and outdoor environments of primary schools were selected for sampling. PCB levels were determined in dust samples collected from indoor and outdoor environments of the primary schools in Düzce. PCB analyses were performed by using the Gas chromatograph/Mass Spectrometer (GC/MS) instrument. In the obtained results, outdoor ΣPCB concentrations were between 0.737 and 22.307 ng/gr, with an average of 3,626 ng/gr. Indoor ΣPCB concentrations were between 17.17 and 294.22 ng/gr, with an average of 66.89 ng/gr. High ∑PCB concentrations in indoor samples show that the contribution of indoor sources and the effect of accumulation in indoor environments by transport from the outdoor environments is greater. In the evaluation made according to outdoor sources, the highest concentrations were obtained mostly at points close to the industrial area. The lowest concentrations were measured at rural sampling points.
- 14 January 2022
- Published by Dogal Afetler ve Cevre Dergisi in Doğal Afetler ve Çevre Dergisi
- Vol. 8 (1) , 53-65
Open AccessDüzce İlinde İlkokulların İç ve Dış Ortamlarındaki Toz Örneklerinde PCB Düzeylerinin Belirlenmesi
Düzce province, where industry, traffic and residential areas are intertwined, is developing rapidly and therefore environmental pollution is intensely felt in the region. Air pollutants from emission sources cannot be dispersed due to the geographical location of the province and pose important health risks. In this study, dust samples were collected at different locations in order to explain the regional pollution distribution and various emission sources. Because children are more sensitive to air pollutants, indoor and outdoor environments of primary schools were selected for sampling. PCB levels were determined in dust samples collected from indoor and outdoor environments of the primary schools in Düzce. PCB analyses were performed by using the Gas chromatograph/Mass Spectrometer (GC/MS) instrument. In the obtained results, outdoor ΣPCB concentrations were between 0.737 and 22.307 ng/gr, with an average of 3,626 ng/gr. Indoor ΣPCB concentrations were between 17.17 and 294.22 ng/gr, with an average of 66.89 ng/gr. High ∑PCB concentrations in indoor samples show that the contribution of indoor sources and the effect of accumulation in indoor environments by transport from the outdoor environments is greater. In the evaluation made according to outdoor sources, the highest concentrations were obtained mostly at points close to the industrial area. The lowest concentrations were measured at rural sampling points.
- 11 January 2019
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 26 (7) , 6839-6854
Characterization and source estimates of primary and secondary carbonaceous aerosols at urban and suburban atmospheres of Düzce, Turkey
Düzce is one of the cities located in the western Black Sea region of Turkey with a population of 377,610 in 2017 (TUIK, 2017 ). There is no satisfying scientific information available to address the contribution of primary and secondary sources of carbonaceous aerosols to the observed PM10 levels in the city. The main objective of the study is to determine the levels and sources of carbonaceous aerosols in PM10. For this purpose, PM10 samples were collected at urban and suburban locations in Düzce during winter and summer season in 2015. Average summer OC and EC concentrations in the urban area were 9.5 and 1.3 μg m−3, respectively, while the corresponding concentrations were observed as 28.5 and 2.3 μg m−3, respectively for winter season. Summer mean OC and EC levels at the suburban site were 5.46 and 0.37 μg m−3, respectively, while those for winter were found as 6.68 and 0.61 μg m−3.The contributions of OC and EC to measured PM10 levels were found in the range of 10% to 60% and 1% to 7%, respectively, at the urban station while the associated contributions were in the range of 10% to 50% and 0.6% to 6%, respectively, at the suburban station. The concentrations measured during winter months in both areas were found to be higher than those measured during summer months. The EC tracer method was used in order to estimate the SOC contribution. The contribution of SOC concentrations to the total PM10 mass was found to be higher during winter in the urban area and during summer in the suburban area.
- 11 January 2019
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 26 (7) , 6839-6854
Characterization and source estimates of primary and secondary carbonaceous aerosols at urban and suburban atmospheres of Düzce, Turkey
Düzce is one of the cities located in the western Black Sea region of Turkey with a population of 377,610 in 2017 (TUIK, 2017 ). There is no satisfying scientific information available to address the contribution of primary and secondary sources of carbonaceous aerosols to the observed PM10 levels in the city. The main objective of the study is to determine the levels and sources of carbonaceous aerosols in PM10. For this purpose, PM10 samples were collected at urban and suburban locations in Düzce during winter and summer season in 2015. Average summer OC and EC concentrations in the urban area were 9.5 and 1.3 μg m−3, respectively, while the corresponding concentrations were observed as 28.5 and 2.3 μg m−3, respectively for winter season. Summer mean OC and EC levels at the suburban site were 5.46 and 0.37 μg m−3, respectively, while those for winter were found as 6.68 and 0.61 μg m−3.The contributions of OC and EC to measured PM10 levels were found in the range of 10% to 60% and 1% to 7%, respectively, at the urban station while the associated contributions were in the range of 10% to 50% and 0.6% to 6%, respectively, at the suburban station. The concentrations measured during winter months in both areas were found to be higher than those measured during summer months. The EC tracer method was used in order to estimate the SOC contribution. The contribution of SOC concentrations to the total PM10 mass was found to be higher during winter in the urban area and during summer in the suburban area.
- 13 September 2013
- Published by Springer Nature
- p. 291-303
Probabilistic Health Risk Assessment of PCDD/Fs in Vegetable Foods at Highly Polluted Area in Turkey
- 13 September 2013
- Published by Springer Nature
- p. 291-303
Probabilistic Health Risk Assessment of PCDD/Fs in Vegetable Foods at Highly Polluted Area in Turkey
- Open Access
- 22 April 2013
- Published by Taylor & Francis in Journal of the Air & Waste Management Association
- Vol. 63 (10) , 1148-1162
C5–C12 volatile organic compounds at roadside, residential, and background locations in Ankara, Turkey: Temporal and spatial variations and sources
Concentrations of 91 volatile organic compounds (VOCs) ranging from C5 to C12 were measured at three sites in Ankara, the capital of Turkey, in the summer of 2003 and winter of 2004. Samples were collected at roadside, residential and background stations at consecutive 4-hr intervals over a 24-hr period for six weeks in each season. Air samples were collected onto cartridges packed with Tenax TA and Carbopack B resins and analyzed by thermal desorption, followed by gas chromatography coupled to a mass selective detector (GC/MSD). Time resolved data provided information on ambient levels, temporal and spatial variations and sources of VOCs in Ankara. Toluene is the most abundant compound at all sites with and average concentration of 13.1 ?g m-3. The mean concentrations of benzene are 12.6, 5.2, and 2.4 ?g m-3 during winter at roadside, residential and background stations, respectively. Diurnal variation in the data together with toluene to benzene concentration ratio (T:B) that is close to 2.0 indicated the influence of traffic related emissions at residential and roadside stations during winter season. Higher T:B ratio observed at residential and background stations during summer period and correlation analysis indicated additional VOC sources. Temporal variations and low m,p-xylene to ethylbenzene ratio (mpX:E) indicated that transported air mass is the major VOC source influencing VOC concentrations measured at the background station.
- 22 April 2013
- Published by Taylor & Francis in Journal of the Air & Waste Management Association
- Vol. 63 (10) , 1148-1162
Open AccessC5–C12 volatile organic compounds at roadside, residential, and background locations in Ankara, Turkey: Temporal and spatial variations and sources
Concentrations of 91 volatile organic compounds (VOCs) ranging from C5 to C12 were measured at three sites in Ankara, the capital of Turkey, in the summer of 2003 and winter of 2004. Samples were collected at roadside, residential and background stations at consecutive 4-hr intervals over a 24-hr period for six weeks in each season. Air samples were collected onto cartridges packed with Tenax TA and Carbopack B resins and analyzed by thermal desorption, followed by gas chromatography coupled to a mass selective detector (GC/MSD). Time resolved data provided information on ambient levels, temporal and spatial variations and sources of VOCs in Ankara. Toluene is the most abundant compound at all sites with and average concentration of 13.1 ?g m-3. The mean concentrations of benzene are 12.6, 5.2, and 2.4 ?g m-3 during winter at roadside, residential and background stations, respectively. Diurnal variation in the data together with toluene to benzene concentration ratio (T:B) that is close to 2.0 indicated the influence of traffic related emissions at residential and roadside stations during winter season. Higher T:B ratio observed at residential and background stations during summer period and correlation analysis indicated additional VOC sources. Temporal variations and low m,p-xylene to ethylbenzene ratio (mpX:E) indicated that transported air mass is the major VOC source influencing VOC concentrations measured at the background station.