HWHuang Wu

Huang Wu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Huang Wu has a total of 38 co-authors. Here are the top co-authors by number of shared publications:

  • Lingzhi Zhao

    Department of Optometry, The Second Hospital of Jilin University, Changchun, China

    12 shared publications
  • Lu Liu

    Department of Optometry, The Second Hospital of Jilin University, Changchun, China

    6 shared publications
  • Lingxian Xu

    Department of Ophthalmology, Henan Provincial People’s Hospital, Zhengzhou, China

    5 shared publications
  • Bo Yu

    Department of Optometry, The Second Hospital of Jilin University, Changchun, China

    4 shared publications
  • Ning Yang

    Department of Optometry, The Second Hospital of Jilin University, Changchun, China

    3 shared publications
  • Ruiqing Wang

    Department of Optometry, The Second Hospital of Jilin University, Changchun, China

    2 shared publications

Latest Publications

  • Open Access

    Visual acuity and stereopsis across the parafoveal and perifoveal retina in young adults: an eccentricity and meridian analysis

    by Bo Yu, Lu Liu, Ning Yang, Lingxian Xu, Huang Wu

    Background: Visual acuity (VA) and stereoacuity (SVA) are fundamental visual functions that decline with increasing retinal eccentricity. Patients with macular degeneration and other central vision disorders often rely on paracentral vision, yet location-specific reference data for VA and SVA across the parafoveal and perifoveal retina remain limited. This study aimed to quantify the distribution of binocular VA and SVA across eccentricity and meridian in young adults, develop prediction equations with 95% prediction intervals, and examine the relationship between these two visual functions in the paracentral retina. Methods: Thirty-five healthy young adults (13 males, 22 females; mean age 27.23 ± 2.43 years) were recruited. Binocular VA and SVA were measured at 48 test positions across eight meridians (0°, 45°, 90°, 135°, 180°, 225°, 270°, 315°) and six eccentricities (2.5° to 15° in 2.5° increments) using a polarized 3D display system. A four-alternative forced-choice task was employed with tumbling E optotypes for VA and random-dot stereograms for SVA. Eye tracking ensured fixation stability throughout testing. Generalized estimating equations were used to analyze the effects of eccentricity and meridian. Linear mixed-effects models and Bayesian Tobit models were employed to develop prediction equations. Ten-fold cross-validation assessed model generalizability. Results: Both VA and SVA significantly declined with increasing eccentricity ( P < 0.001). VA decreased from a median of 0.40 logMAR at 2.5° to 1.20 logMAR at 15.0°, at a rate of 0.057 logMAR per degree. SVA increased from 2.1 log arcsec at 2.5° to 2.9 log arcsec at 7.5°, declining approximately three times faster than VA (0.154 log arcsec per degree). Both functions showed significant meridional anisotropy ( P < 0.001), with the horizontal meridian demonstrating 0.058 logMAR better VA and 0.106 log arcsec better SVA compared to the vertical meridian. Despite parallel declines with eccentricity, no significant correlations were observed between VA and SVA at any test position within 7.5° eccentricity ( P > 0.05). Conclusions: VA and SVA deteriorate with increasing eccentricity in the paracentral retina, with stereopsis declining approximately three times faster and demonstrating a more pronounced horizontal-over-vertical advantage. The absence of correlation between VA and SVA suggests distinct neural mechanisms underlying these functions. The prediction equations with 95% prediction intervals provide reference benchmarks for healthy young adults, facilitating clinical interpretation of patient measurements and enabling objective assessment of disease-related changes in paracentral visual function.

  • Open Access

    Assessment of autostereoscopic perception using artificial intelligence-enhanced face tracking technology

    by Bo Yu, Lu Liu, Ning Yang, Lingzhi Zhao, Huang Wu

    Purpose: Stereopsis, the ability of humans to perceive depth through distinct visual stimuli in each eye, is foundational to autostereoscopic technology in computing. However, ensuring stable head position during assessments has been challenging. This study evaluated the utility of artificial intelligence (AI)-enhanced face tracking technology in overcoming this challenge by ensuring that each eye consistently receives its intended image. Methods: The Lume Pad 2, an autostereoscopic tablet with AI-enhanced face tracking, was utilized to simulate quantitative parts of the Stereo Fly test and TNO Stereotests for contour and random dot stereopsis. The study recruited 30 children (14 males and 16 females, mean age of 9.2 ± 0.3 years, age range of 6–12 years) and 30 adults (10 males and 20 females, mean age of 29.4 ± 1.0 years, age range of 21–42 years) to assess the tablet’s inter-session reliability. Agreement between conventional and the autostereoscopic tablet-simulated stereotests was tested in a larger group of 181 children (91 males and 90 females, mean age of 9.1 ± 0.4 years, age range of 6–12 years) and 160 adults (69 males and 91 females, mean age of 38.6 ± 2.1 years, age range of 21–65 years). Inter-session reliability and agreement were analyzed using weighted Kappa coefficient and non-parametric Bland-Altman analysis. Results: The autostereoscopic tablet demonstrated high inter-session reliability (κ all > 0.80), except for the simulated TNO Stereotest in adults, which demonstrated moderate inter-session reliability (κ = 0.571). Non-parametric Bland-Altman analysis revealed zero median differences, confirming consistent inter-session reliability. Similar patterns were observed in comparing AI-based and conventional methods, with both the weighted Kappa coefficient (κ all > 0.80) and non-parametric Bland-Altman analysis indicating significant agreement. The agreement between methodologies was confirmed by permissible differences, which were smaller than the minimum step range. Conclusion: The integration of AI-based autostereoscopic technology with sub-pixel precision demonstrates significant potential for clinical stereopsis measurements.

  • Open Access

    Quantifying the Relationship Between Unilateral Induced Metamorphopsia and Stereopsis Impairment

    by Lingxian Xu, Lu Liu, Bo Yu, Ning Yang, Huang Wu

    Purpose: To investigate the relationship between unilateral metamorphopsia, characterized by visual distortions in one eye, and impaired stereopsis. Methods: Utilizing both near and distance measurements through advanced testing systems, including 4K smartphones and an active shutter three-dimensional system, we simulated varying degrees of unilateral metamorphopsia in 30 healthy young adults aged between 21 and 29 years. Two types of contour-based stereotest symbols, lines and squares, were developed. Distortions were classified into six distinct patterns, each further divided into eight grades of severity. Participants were tasked with identifying visual targets, and their stereothresholds were determined under different conditions of induced distortion. Stereopsis was measured within a range of 2.9 to 1.0 log arcsec, at 0.2 log arcsec intervals. Stereopsis changes under different distortion scenarios were analyzed using the generalized estimating equations, with a sequential Bonferroni adjustment applied for pairwise comparisons. Results: A direct and quantifiable correlation was observed between the severity of metamorphopsia and reductions in stereopsis. As the degree of visual distortion increased, notably in both frequency and amplitude, there was a corresponding decline in stereopsis. This relationship held true in both near and distance measurements of stereopsis. Statistical analyses further reinforced these findings, highlighting a significant detrimental effect of distortion components on stereoacuity. Conclusions: The findings highlight the clinical significance of understanding the interplay between unilateral metamorphopsia and stereopsis. Early interventions in conditions leading to metamorphopsia might be critical to maintaining optimal stereopsis.

  • Open Access

    A comparative study of stereopsis measurements: analyzing natural conditions versus dichoptic presentation using smartphones and ultraviolet printer technology

    by Lu Liu, Jiang Liu, Lingxian Xu, Lingzhi Zhao, Huang Wu

    Background: Accurate differentiation between stereopsis assessments in the natural and dichoptic presentation states has proven challenging with commercial stereopsis measurement tools. This study proposes a novel method to delineate these differences more precisely. Methods: We instituted two stereopsis test systems predicated on a pair of 4K smartphones and a modified Frisby Near Stereotest (FNS) version. Stereoacuity was evaluated both in the natural environment state (via the modified FNS) and the dichoptic state (via smartphones). Thirty subjects aged 20 to 28 years participated in the study with the best-corrected visual acuity (VA) of each eye no less than 0 logMAR and stereoauity of no worse than 40″. Varying degrees of monocular VA loss were induced using the fogging method, while this study does not explore conditions where the VA of both eyes is worse than 0 logMAR. Results: When the VA difference between the two eyes did not exceed 0.2 logMAR, the modified FNS produced lower stereoacuity values compared to the 4K smartphones (Wilcoxon signed-rank test: difference = 0 logMAR, Z = −3.879, P < 0.001; difference = 0.1 logMAR, Z = −3.478, P = 0.001; difference = 0.2 logMAR, Z = −3.977, P < 0.001). Conversely, no significant differences were observed when the binocular vision difference exceeded 0.2 logMAR (difference = 0.3 logMAR, Z = −1.880, P = 0.060; difference = 0.4 logMAR, Z = −1.784, P = 0.074; difference = 0.5 logMAR, Z = −1.812, P = 0.070). Conclusion: The findings suggest that stereoacuity values measurements taken in the natural environment state surpass those derived from the dichoptic presentation. However, the observed difference diminishes as stereopsis decreases, corresponding to an increase in induced anisometropia.


  • Open Access

    The influence of simulated visual impairment on distance stereopsis

    by Lu Liu, Lingxian Xu, Bo Yu, Lingzhi Zhao, Huang Wu

    The intricate interrelationships between visual acuity (VA) and stereopsis depend on an array of factors, incorporating the nature of vision impairment, its manifestation (monocular versus binocular), and the classification of stereopsis test symbols used. The objectives of this study were to methodically dissect these multifaceted interactions by simulating a diverse range of vision loss conditions. Thirty medical students with normal vision were subjected to simulated vision loss through opacification and blurring methodologies. Stereopsis was assessed at a distance using both contour-based and random-dot-based symbols under equal binocular and varied monocular VA conditions. In this study, opacification consistently affected stereopsis more than blurring at equivalent VA reductions. However, this difference was absent in contour-based symbols under binocular vision impairment conditions. Significant differences in stereopsis emerged between monocular and binocular vision within the opacification contour-based groups. These differences were less evident in the opacification and blurring groups using random-dot-based patterns. In terms of symbols, the contour-based test demonstrated superior results to the random-dot-based test, particularly under decreased VA. In sum, the method of VA reduction and the choice of stereogram significantly impact distance stereopsis outcomes. This understanding can guide clinical assessments of stereopsis in individuals with varying visual impairments.


  • Open Access

    Comparison of stereopsis thresholds measured with conventional methods and a new eye tracking method

    by Lu Liu, Bo Yu, Lingxian Xu, Shiyi Wang, Lingzhi Zhao, Huang Wu

    Stereopsis is the ability to perceive depth using the slightly different views from two eyes. This study aims to conduct innovative stereopsis tests using the objective data outputted by eye tracking technology. A laptop and an eye tracker were used to establish the test system. Anaglyphic glasses were employed to execute the stereopsis assessment. The test symbol employed was devised to emulate the quantitative measurement component of the Random Dot 3 Stereo Acuity Test. Sub-pixel technology was used to increase the disparity accuracy of test pages. The tested disparities were: 160″, 100″, 63″, 50″, 40″, 32″, 25″, 20″, 16″, and 12.5″. The test was conducted at a distance of 0.65m. Conventional and eye tracking stereopsis assessments were conducted on 120 subjects. Wilcoxon signed-rank test was used to test the difference, while the Bland-Altman method was used to test the consistency between the two methods. The Wilcoxon signed-rank test showed no significant difference between conventional and eye tracking thresholds of stereopsis (Z = −1.497, P = 0.134). There was a high level of agreement between the two methods using Bland- Altman statistical analysis (The 95 per cent limits of agreement were −0.40 to 0.47 log arcsec). Stereoacuity can be evaluated utilizing an innovative stereopsis measurement system grounded in eye tracking technology.


  • Open Access

    Evaluation of the Relationship Between Aniseikonia and Stereopsis Using a New Method

    by Lingxian Xu, Lu Liu, Huang Wu

    Purpose: To investigate the influence of induced aniseikonia on stereopsis measured by contour-based and random-dot-based stereograms using a new method.Methods: Unlike previous studies in which aniseikonia was induced using magnifiers, which potentially influenced the position of the test symbols in the half-view, here the image was magnified while maintaining each test symbol’s central position within the half-view. A phoropter and two 4K smartphones were used to measure stereopsis in seventeen young adults aged 20–28 years old. Stereopsis was tested using both contour-based and random-dot-based stereograms under overall or meridional aniseikonia with magnifications ranging from 2.5 to 30%. Repeated measures ANOVA was used to evaluate the effect of aniseikonia on stereopsis.Results: Stereopsis decreased with an increase in aniseikonia magnification in the overall, horizontal, and vertical directions. Stereopsis values (log arcsec) increased from 1.29 ± 0.14 at baseline to 2.38 ± 0.16 with 30% overall aniseikonia of contour-based stereograms. In random-dot based stereograms, stereopsis values increased from 1.29 ± 0.16 at baseline to 2.24 ± 0.23 with 22.5% overall aniseikonia. Overall aniseikonia caused a significantly greater impairment on stereopsis as compared with the changes in meridional directions. In contour-based stereograms, vertical aniseikonia had significantly less impact on stereopsis than horizontal aniseikonia of identical magnification. The opposite phenomenon was found in random-dot-based stereograms.Conclusion: Stereopsis decreased with an increase of magnification of induced aniseikonia. Magnifying patterns (overall, horizontal, or vertical) also significantly affected stereopsis. The conflicting impact of meridional aniseikonia on stereopsis measured by contour-based and random-dot-based stereograms may be associated with the uniqueness of the two test systems.


  • Retraction
    Open Access

    [Retracted] miR‑124 inhibits proliferation and invasion of human retinoblastoma cells by targeting STAT3

    by Shu Liu, Chunmei Hu, Yingxue Wang, Guang Shi, Yarong Li, Huang Wu

    Following the publication of this paper, it was drawn to the Editors' attention by a concerned reader that the GAPDH bands shown in the western blots in Fig. 6A were strikingly similar to data appearing in different form in other articles by different authors. Owing to the fact that the contentious data in the above article had already been published elsewhere prior to its submission to Oncology Reports, the Editor has decided that this paper should be retracted from the Journal. After having been in contact with the authors, they agreed with the decision to retract the paper. The Editor apologizes to the readership for any inconvenience caused. [the original article was published in Oncology Reports 36: 2398‑2404, 2016; DOI: 10.3892/or.2016.4999]

  • Open Access

    Evaluating the Mechanism by Which the TNO Stereo Test Overestimates Stereo Thresholds

    by Yu Zhang, Bingbing Meng, Huang Wu

    Several studies have revealed that results of the TNO stereo test may overestimate the stereoacuity value (the less the better) compared with other testing measurements. The manner in which vision is divided among two eyes of a person wearing anaglyph glasses may play an important role. This study aimed to examine the effect of anaglyph glasses on stereopsis measurements. A stereopsis measurement system using a phoropter and two Sony smartphones was established. Four types of test patterns, including the original TNO stereo test pictures, isoluminant red‐green pictures, grayscale pictures, and black and white dots pictures, were designed. A total of 32 participants were recruited for this study. A significant difference was found among the four groups (Friedman test, chi‐square = 50.985, P < 0.001). The Wilcoxon signed‐rank test was used to detect differences between the groups. The stereoacuity of the original TNO group was significantly worse than those of the isoluminant, grayscale, and black‐white groups. However, no significant difference was found between the isoluminant and grayscale groups. The correlation coefficient between the original TNO and isoluminant groups was 0.952 (Spearman’s rho, P < 0.001; 95% confidence interval (CI), 0.901–0.988), while that between the original and grayscale groups was 0.771 (Spearman’s rho, P < 0.001; 95% CI, 0.550–0.916). Anaglyph glasses played an important role in determining the stereoacuity values with the TNO stereo test, and the results were overestimated when compared with that of the other testing methods. The imbalance of chroma and luminance between the two eyes caused by the anaglyph glasses was indicated as one of the reasons for the overestimation of stereo thresholds.


  • Open Access

    Effect of Luminance and Contrast Variation on Stereoacuity Measurements Using Smartphone Technology

    by Lu Liu, Lingxian Xu, Junyue Wang, Huang Wu

    Owing to the limitations of printed stereoacuity tests, the effects of luminance and contrast on stereopsis have not yet been sufficiently investigated, despite its important implications in designing stereoacuity measuring instruments, particularly for electronic devices. A stereopsis measurement system was established using two 4 K smartphones and a phoropter to evaluate the effects of luminance and contrast variations on the stereoacuity test. Seventeen young subjects with normal visual acuity and stereopsis were recruited. Two types of test symbols, contour‐based and random‐dot‐based, were used in the experiment. Four series tests were established with different maximum brightness values, including 240 lux, 120 lux, 60 lux, and 30 lux. Each series test contained 19 pages with different contrasts between 95% and 5% and was calculated using the Michelson contrast formula. No significant difference was found for both contour‐based and random‐dot‐based stereograms in any of the contrast groups with different maximum brightness. Similarly, no significant difference was found between contour‐based and random‐dot‐based patterns under different contrasts of above 35%. As the contrast decreased below 30%, the stereopsis was significantly better in the contour‐based pattern than in the random‐dot‐based pattern for some degrees of contrast. The luminance and contrast of the digital display are not critical factors for stereoacuity under normal circumstances. This implies that a standard monitor with a certain 3D technology can be used to measure the stereoacuity threshold without calibrating the luminance and contrast.