Henrique Takachi Moriya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Henrique Takachi Moriya has a total of 272 co-authors. Here are the top co-authors by number of shared publications:
- Geraldo Lorenzi-Filho
Universidade de São Paulo
11 shared publications - Renato Lima Vitorasso
Oracle Life Sciences, São Paulo, Brazil
7 shared publications - Fernanda Degobbi Tenorio Quirino Santos Lopes
Laboratory of Experimental Therapeutics (LIM20), Department of Clinical Medicine, School of Medicine, University of Sao Paulo
6 shared publications - Adriano Mesquita Alencar
Institute of Physics, University of São Paulo, São Paulo, Brazil
5 shared publications - Alembert Eistein Lino Alvarado
Biomedical Engineering Laboratory, Escola Politécnica University of Sao Paulo Sao Paulo Brazil
5 shared publications - Celso Ricardo Fernandes Carvalho
University of São Paulo
5 shared publications
Latest Publications
- Open Access
- 31 March 2026
- Published by Global Clinical Engineering Journal in Global Clinical Engineering Journal
- Vol. 8 (1) , 66-72
Accuracy of Control of Infusion Pumps in the Post-Market: A Practical Approach Based on IEC 60601-2-24:2012
Background: Infusion pumps are critical medical devices widely used in clinical practice, particularly in intensive care units, where precise delivery of fluids and medications is essential for patient safety. Deviations in flow rate accuracy may lead to underinfusion or overinfusion, potentially compromising therapeutic outcomes. Post-market surveillance of infusion pump performance is therefore a key component of clinical engineering strategies, especially under real-use hospital conditions; Objective: This study aimed to evaluate the post-market flow rate accuracy of volumetric infusion pumps used at the University Hospital of the University of São Paulo (HU-USP), Brazil, in accordance with the requirements of the IEC 60601-2-24:2012 standard; Material and Methods: Three volumetric infusion pumps of the same model, allocated in the Pediatric Intensive Care Unit (PICU), were evaluated. Flow rate accuracy tests were conducted using a measurement system composed of an analytical balance and dedicated software developed for automated data acquisition and processing. The pumps were tested at a low flow rate of 1 mL/hour over 24 hours under ambient pressure conditions, and at a nominal flow rate of 25 mL/hour over 2 hours under three conditions: ambient pressure, overpressure (+100 mmHg), and vacuum (−100 mmHg). The measured flow rates were compared with the accuracy limits specified by the manufacturer; Results: At the flow rate of 1 mL/h, two of the three infusion pumps did not comply with the manufacturer’s specified accuracy limit (±5%), exhibiting underinfusion. At 25 mL/h, all evaluated pumps demonstrated deviations exceeding the expected tolerance, particularly when subjected to pressure variations. In addition, all devices exhibited a consistent delay of approximately 11 minutes in completing the 24-hour infusion period, despite being newly acquired and previously unopened. These findings indicate performance deviations under post-market conditions that may not be identified through routine acceptance testing alone; Conclusion: The results highlight the importance of implementing systematic post-market performance evaluation of infusion pumps as part of clinical engineering management practices. Even newly acquired devices may present deviations that pose potential risks to patient safety, especially in pediatric intensive care environments. The study supports the expansion of this evaluation methodology to the entire infusion pump inventory of the University Hospital, currently comprising 221 devices, and to testing scenarios involving clinically relevant medications and operating conditions. Such an approach contributes to evidence-based decision-making in medical technology management and to the continuous improvement of healthcare quality and safety.
- 31 March 2026
- Published by Global Clinical Engineering Journal in Global Clinical Engineering Journal
- Vol. 8 (1) , 66-72
Open AccessAccuracy of Control of Infusion Pumps in the Post-Market: A Practical Approach Based on IEC 60601-2-24:2012
Background: Infusion pumps are critical medical devices widely used in clinical practice, particularly in intensive care units, where precise delivery of fluids and medications is essential for patient safety. Deviations in flow rate accuracy may lead to underinfusion or overinfusion, potentially compromising therapeutic outcomes. Post-market surveillance of infusion pump performance is therefore a key component of clinical engineering strategies, especially under real-use hospital conditions; Objective: This study aimed to evaluate the post-market flow rate accuracy of volumetric infusion pumps used at the University Hospital of the University of São Paulo (HU-USP), Brazil, in accordance with the requirements of the IEC 60601-2-24:2012 standard; Material and Methods: Three volumetric infusion pumps of the same model, allocated in the Pediatric Intensive Care Unit (PICU), were evaluated. Flow rate accuracy tests were conducted using a measurement system composed of an analytical balance and dedicated software developed for automated data acquisition and processing. The pumps were tested at a low flow rate of 1 mL/hour over 24 hours under ambient pressure conditions, and at a nominal flow rate of 25 mL/hour over 2 hours under three conditions: ambient pressure, overpressure (+100 mmHg), and vacuum (−100 mmHg). The measured flow rates were compared with the accuracy limits specified by the manufacturer; Results: At the flow rate of 1 mL/h, two of the three infusion pumps did not comply with the manufacturer’s specified accuracy limit (±5%), exhibiting underinfusion. At 25 mL/h, all evaluated pumps demonstrated deviations exceeding the expected tolerance, particularly when subjected to pressure variations. In addition, all devices exhibited a consistent delay of approximately 11 minutes in completing the 24-hour infusion period, despite being newly acquired and previously unopened. These findings indicate performance deviations under post-market conditions that may not be identified through routine acceptance testing alone; Conclusion: The results highlight the importance of implementing systematic post-market performance evaluation of infusion pumps as part of clinical engineering management practices. Even newly acquired devices may present deviations that pose potential risks to patient safety, especially in pediatric intensive care environments. The study supports the expansion of this evaluation methodology to the entire infusion pump inventory of the University Hospital, currently comprising 221 devices, and to testing scenarios involving clinically relevant medications and operating conditions. Such an approach contributes to evidence-based decision-making in medical technology management and to the continuous improvement of healthcare quality and safety.
- Open Access
- 5 August 2024
- Published by Springer Nature in Discover Public Health
- Vol. 21 (1) , 1-11
Premarket and postmarket regulatory challenges for mechanical ventilators: scenario in Brazil and comparison with other countries
- 5 August 2024
- Published by Springer Nature in Discover Public Health
- Vol. 21 (1) , 1-11
Open AccessPremarket and postmarket regulatory challenges for mechanical ventilators: scenario in Brazil and comparison with other countries
- 1 July 2024
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 38 (5) , 961-979
Central venous pressure waveform analysis during sleep/rest: a novel approach to enhance intensive care unit post-extubation monitoring of extubation failure
This pilot study aimed to investigate the relation between cardio-respiratory parameters derived from Central Venous Pressure (CVP) waveform and Extubation Failure (EF) in mechanically ventilated ICU patients during post-extubation period. This study also proposes a new methodology for analysing these parameters during rest/sleep periods to try to improve the identification of EF. We conducted a prospective observational study, computing CVP-derived parameters including breathing effort, spectral analyses, and entropy in twenty critically ill patients post-extubation. The Dynamic Warping Index (DWi) was calculated from the respiratory component extracted from the CVP signal to identify rest/sleep states. The obtained parameters from EF patients and patients without EF were compared both during arbitrary periods and during reduced DWi (rest/sleep). We have analysed data from twenty patients of which nine experienced EF. Our findings may suggest significantly increased respiratory effort in EF patients compared to those successfully extubated. Our study also suggests the occurrence of significant change in the frequency dispersion of the cardiac signal component. We also identified a possible improvement in the differentiation between the two groups of patients when assessed during rest/sleep states. Although with caveats regarding the sample size, the results of this pilot study may suggest that CVP-derived cardio-respiratory parameters are valuable for monitoring respiratory failure during post-extubation, which could aid in managing non-invasive interventions and possibly reduce the incidence of EF. Our findings also indicate the possible importance of considering sleep/rest state when assessing cardio-respiratory parameters, which could enhance respiratory failure detection/monitoring.
- 1 July 2024
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 38 (5) , 961-979
Central venous pressure waveform analysis during sleep/rest: a novel approach to enhance intensive care unit post-extubation monitoring of extubation failure
This pilot study aimed to investigate the relation between cardio-respiratory parameters derived from Central Venous Pressure (CVP) waveform and Extubation Failure (EF) in mechanically ventilated ICU patients during post-extubation period. This study also proposes a new methodology for analysing these parameters during rest/sleep periods to try to improve the identification of EF. We conducted a prospective observational study, computing CVP-derived parameters including breathing effort, spectral analyses, and entropy in twenty critically ill patients post-extubation. The Dynamic Warping Index (DWi) was calculated from the respiratory component extracted from the CVP signal to identify rest/sleep states. The obtained parameters from EF patients and patients without EF were compared both during arbitrary periods and during reduced DWi (rest/sleep). We have analysed data from twenty patients of which nine experienced EF. Our findings may suggest significantly increased respiratory effort in EF patients compared to those successfully extubated. Our study also suggests the occurrence of significant change in the frequency dispersion of the cardiac signal component. We also identified a possible improvement in the differentiation between the two groups of patients when assessed during rest/sleep states. Although with caveats regarding the sample size, the results of this pilot study may suggest that CVP-derived cardio-respiratory parameters are valuable for monitoring respiratory failure during post-extubation, which could aid in managing non-invasive interventions and possibly reduce the incidence of EF. Our findings also indicate the possible importance of considering sleep/rest state when assessing cardio-respiratory parameters, which could enhance respiratory failure detection/monitoring.
- 24 January 2024
- Published by Springer Nature
- p. 380-385
Development of a Neonatal Lung Simulator with Variable Compliance
- 24 January 2024
- Published by Springer Nature
- p. 380-385
Development of a Neonatal Lung Simulator with Variable Compliance
- 24 January 2024
- Published by Springer Nature
- p. 273-280
Cardiopulmonary Exercise Testing Data Processing and Storage Tools
- 24 January 2024
- Published by Springer Nature
- p. 273-280
Cardiopulmonary Exercise Testing Data Processing and Storage Tools
- 24 January 2024
- Published by Springer Nature
- p. 424-430
Assessment of Lung Ventilators’ Pressure Alarms System in a Controlled Scenario
- 24 January 2024
- Published by Springer Nature
- p. 424-430
Assessment of Lung Ventilators’ Pressure Alarms System in a Controlled Scenario
- 4 January 2024
- Published by Springer Nature
- p. 281-289
Comparison of Rotation of Vectorcardiograms from Inverse Dower and Kors Transformation Matrices
- 4 January 2024
- Published by Springer Nature
- p. 281-289
Comparison of Rotation of Vectorcardiograms from Inverse Dower and Kors Transformation Matrices
- 4 January 2024
- Published by Springer Nature
- p. 505-511
Wearable Influence on Breathing Pattern Measured by Unrestricted Barometric Plethysmography in Wistar Rats
- 4 January 2024
- Published by Springer Nature
- p. 505-511
Wearable Influence on Breathing Pattern Measured by Unrestricted Barometric Plethysmography in Wistar Rats
- 17 December 2023
- Published by Springer Nature
- p. 210-222
Computational Fluid Dynamics for Assessment of Airflow Patterns in the Airway Tree
- 17 December 2023
- Published by Springer Nature
- p. 210-222
Computational Fluid Dynamics for Assessment of Airflow Patterns in the Airway Tree