Seiya Manabe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Seiya Manabe has a total of 99 co-authors. Here are the top co-authors by number of shared publications:
- Yukinobu Watanabe
Faculty of Engineering Sciences, Kyushu University, Fukuoka, Japan
9 shared publications - Masanori Hashimoto
Kyoto University
8 shared publications - Wang Liao
School of Systems Engineering, Kochi University of Technology, Kami, Japan
8 shared publications - Shin-Ichiro Abe
Japan Atomic Energy Agency (JAEA), Tkai, Japan
7 shared publications - Hideki Harano
National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology
6 shared publications - Tetsuro Matsumoto
National Institute of Advanced Industrial Science and Technology (AIST)
4 shared publications
Latest Publications
- Open Access
- 27 May 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 58 (10)
An exploratory study on 222Rn measurement method using a length-compensated proportional counter
- 27 May 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 58 (10)
Open AccessAn exploratory study on 222Rn measurement method using a length-compensated proportional counter
- Open Access
Development of an Integrating Sphere-Based Wide-Range Light Source System for the Linearity Evaluation of a Photodetector Used in Radiation Detection and Bioanalysis Instruments
We developed a compact wide-range light source system for evaluating the linearity of photomultiplier tube (PMT) output. This system utilizes two integrating spheres equipped with a continuously variable slit and output aperture to modulate a stabilized light-emitting diode light source, producing an output light range as wide as seven orders of magnitude. To verify the wide linearity range of the integrating sphere system, three silicon photodiodes coupled with electric current readers monitored the light intensity and simultaneously confirmed each other’s linearity. Using this system, we evaluated the linearity of the PMT used in a neutron detector we are currently developing and found it to have a linear range of more than four orders of magnitude. Non-linearity characteristics were also successfully measured in detail at a higher output range. Neutron detector operation requires both calibration of the detection efficiency and evaluation of the linearity between the neutron dose and its output. These results indicate that this system is a simple and useful method to evaluate the linearity of photodetectors used in radiation detectors and other applications.
Open AccessDevelopment of an Integrating Sphere-Based Wide-Range Light Source System for the Linearity Evaluation of a Photodetector Used in Radiation Detection and Bioanalysis Instruments
We developed a compact wide-range light source system for evaluating the linearity of photomultiplier tube (PMT) output. This system utilizes two integrating spheres equipped with a continuously variable slit and output aperture to modulate a stabilized light-emitting diode light source, producing an output light range as wide as seven orders of magnitude. To verify the wide linearity range of the integrating sphere system, three silicon photodiodes coupled with electric current readers monitored the light intensity and simultaneously confirmed each other’s linearity. Using this system, we evaluated the linearity of the PMT used in a neutron detector we are currently developing and found it to have a linear range of more than four orders of magnitude. Non-linearity characteristics were also successfully measured in detail at a higher output range. Neutron detector operation requires both calibration of the detection efficiency and evaluation of the linearity between the neutron dose and its output. These results indicate that this system is a simple and useful method to evaluate the linearity of photodetectors used in radiation detectors and other applications.
- 13 November 2024
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 200 (16-18) , 1696-1700
Evaluation of an ionization chamber characteristics for 222Rn calibration
The National Metrology Institute of Japan plan to use an inner-through-type ionization chamber (IC) as a working standard to calibrate radon monitors. Novel methods to calibrate the IC were described, and the calibration factor, CF [Bq m −3 A−1], of the IC with its expanded uncertainty (k = 2) was evaluated to be (2.0 ± 0.2) × 1016 Bq m−3 A−1 in the order of 10−13 A in the IC output current. In this study, the CFs, evaluated under sampling conditions between continuous gas flowing and stationary gas filled inside the IC, were in agreement within the uncertainty.
- 13 November 2024
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 200 (16-18) , 1696-1700
Evaluation of an ionization chamber characteristics for 222Rn calibration
The National Metrology Institute of Japan plan to use an inner-through-type ionization chamber (IC) as a working standard to calibrate radon monitors. Novel methods to calibrate the IC were described, and the calibration factor, CF [Bq m −3 A−1], of the IC with its expanded uncertainty (k = 2) was evaluated to be (2.0 ± 0.2) × 1016 Bq m−3 A−1 in the order of 10−13 A in the IC output current. In this study, the CFs, evaluated under sampling conditions between continuous gas flowing and stationary gas filled inside the IC, were in agreement within the uncertainty.
- 18 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (4) , 912-920
Impact of Irradiation Side on Muon-Induced Single-Event Upsets in 65-nm Bulk SRAMs
We have newly analyzed negative and positive muon-induced single event upset (SEU) data in irradiation tests from the package side (PS) of 65-nm bulk static random access memory (SRAM) and compared with previous results of irradiation tests from the board side (BS). The peak SEU cross section is at 28 MeV/c for PS irradiation, which differs from 38 MeV/c for BS irradiation. The magnitude of the peak SEU cross section for PS irradiation is approximately twice that of BS irradiation for both positive and negative muons. Through simulations using Geant4, we explain the difference quantitatively. This simulation also reproduces the experimental SEU cross sections for tilted incidence of the muon beam onto the device board. The soft error rates (SERs) are estimated under a realistic environment considering the zenith angle distribution of muon flux. As a result, it was found that the estimated SERs were not significantly different from the case without zenith angle distribution. This result indicates that experimental data from irradiation tests in which the device board is placed perpendicular to the incident beam are expected to be useful for estimating muon-induced SERs in terrestrial environments.
- 18 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (4) , 912-920
Impact of Irradiation Side on Muon-Induced Single-Event Upsets in 65-nm Bulk SRAMs
We have newly analyzed negative and positive muon-induced single event upset (SEU) data in irradiation tests from the package side (PS) of 65-nm bulk static random access memory (SRAM) and compared with previous results of irradiation tests from the board side (BS). The peak SEU cross section is at 28 MeV/c for PS irradiation, which differs from 38 MeV/c for BS irradiation. The magnitude of the peak SEU cross section for PS irradiation is approximately twice that of BS irradiation for both positive and negative muons. Through simulations using Geant4, we explain the difference quantitatively. This simulation also reproduces the experimental SEU cross sections for tilted incidence of the muon beam onto the device board. The soft error rates (SERs) are estimated under a realistic environment considering the zenith angle distribution of muon flux. As a result, it was found that the estimated SERs were not significantly different from the case without zenith angle distribution. This result indicates that experimental data from irradiation tests in which the device board is placed perpendicular to the incident beam are expected to be useful for estimating muon-induced SERs in terrestrial environments.
- 1 January 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (1A)
International comparison of measurements of neutron source emission rate (2016-2021) - CCRI(III)-K9.Cf.2016
Main text: Section III (neutron measurements) of the Comité Consultatif des Rayonnements Ionisants, CCRI, conducted a comparison of primary measurements of the neutron emission rate of a 252Cf radionuclide source. A single 252Cf source was circulated to all participants between 2016 and 2020. Ten laboratories participated -CMI (Czech Republic), KRISS (Republic of Korea), IRD/LNMRI (Brazil), LNE-LNHB (France), NIM (China), NIST (USA), NMIJ (Japan), NPL (UK), NRC (Canada) and VNIIM (Russia) - with NPL making their measurements at the start and repeating them at the end of the exercise to verify the 250Cf content of the source. Each laboratory reported the emission rate into 4π sr together with a detailed uncertainty budget. All participants used the manganese bath technique except NMIJ who used a relative method based on measurements with a 3He detector in a graphite pile. VNIIM also made measurements using an associated particle technique. CMI, KRISS, LNE-LNHB, NIM, NPL and VNIIM also measured the anisotropy of the source although this did not formally form part of the comparison. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- 1 January 2024
- Published by IOP Publishing in Metrologia
- Vol. 61 (1A)
International comparison of measurements of neutron source emission rate (2016-2021) - CCRI(III)-K9.Cf.2016
Main text: Section III (neutron measurements) of the Comité Consultatif des Rayonnements Ionisants, CCRI, conducted a comparison of primary measurements of the neutron emission rate of a 252Cf radionuclide source. A single 252Cf source was circulated to all participants between 2016 and 2020. Ten laboratories participated -CMI (Czech Republic), KRISS (Republic of Korea), IRD/LNMRI (Brazil), LNE-LNHB (France), NIM (China), NIST (USA), NMIJ (Japan), NPL (UK), NRC (Canada) and VNIIM (Russia) - with NPL making their measurements at the start and repeating them at the end of the exercise to verify the 250Cf content of the source. Each laboratory reported the emission rate into 4π sr together with a detailed uncertainty budget. All participants used the manganese bath technique except NMIJ who used a relative method based on measurements with a 3He detector in a graphite pile. VNIIM also made measurements using an associated particle technique. CMI, KRISS, LNE-LNHB, NIM, NPL and VNIIM also measured the anisotropy of the source although this did not formally form part of the comparison. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- 5 December 2023
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1059
Effect of large-angle incidence on particle identification performance for light-charged () particles by pulse shape analysis with a pad-type nTD silicon detector- 5 December 2023
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1059
Effect of large-angle incidence on particle identification performance for light-charged () particles by pulse shape analysis with a pad-type nTD silicon detector- 14 November 2023
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 61 (1) , 98-110
Measurement of neutron spectra for various thicknesses of concrete and steel shielding at 24-GeV/c proton beam facility using Bonner sphere spectrometer
- 14 November 2023
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 61 (1) , 98-110
Measurement of neutron spectra for various thicknesses of concrete and steel shielding at 24-GeV/c proton beam facility using Bonner sphere spectrometer
- 24 July 2023
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 200, 110952
Proof-of-concept study on a water phantom-based neutron spectrometer: Experimental test with 252Cf and 241Am-Be sources
- 24 July 2023
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 200, 110952
Proof-of-concept study on a water phantom-based neutron spectrometer: Experimental test with 252Cf and 241Am-Be sources
- Open Access
- 26 May 2023
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 284, 01029
Emissions of Hydrogen Isotopes from the Nuclear Muon Capture Reaction in natSi
The energy spectra of protons, deuterons and tritons produced by the nuclear muon capture reaction in natSi were measured at the M1 beam line of Muon Science Innovative Channel (MuSIC) in Research Center for Nuclear Physics (RCNP) using a counter telescope consisting of a Si detector and a CsI(Tl) scintillation detector. The measured energy spectra were consistent with the previous ones. The experimental energy spectra were compared with theoretical model calculations using the Particle and Heavy Ion Transport code System (PHITS). In PHITS, both the dynamical and statistical processes in the nuclear muon capture reaction are described by the Quantum Molecular Dynamics (QMD) or the modified QMD and the Generalized Evaporation Model (GEM), respectively. The PHITS simulation reproduced generally well the measured proton spectrum at emission energies below 20 MeV, while underestimation was seen at emission energies above 20 MeV. The PHITS simulation underestimates remarkably the measured energy spectra of light complex particles (deuterons, tritons, and alpha particles) in the high energy region.
- 26 May 2023
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 284, 01029
Open AccessEmissions of Hydrogen Isotopes from the Nuclear Muon Capture Reaction in natSi
The energy spectra of protons, deuterons and tritons produced by the nuclear muon capture reaction in natSi were measured at the M1 beam line of Muon Science Innovative Channel (MuSIC) in Research Center for Nuclear Physics (RCNP) using a counter telescope consisting of a Si detector and a CsI(Tl) scintillation detector. The measured energy spectra were consistent with the previous ones. The experimental energy spectra were compared with theoretical model calculations using the Particle and Heavy Ion Transport code System (PHITS). In PHITS, both the dynamical and statistical processes in the nuclear muon capture reaction are described by the Quantum Molecular Dynamics (QMD) or the modified QMD and the Generalized Evaporation Model (GEM), respectively. The PHITS simulation reproduced generally well the measured proton spectrum at emission energies below 20 MeV, while underestimation was seen at emission energies above 20 MeV. The PHITS simulation underestimates remarkably the measured energy spectra of light complex particles (deuterons, tritons, and alpha particles) in the high energy region.
- 24 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (7) , 1566-1572
Impact of the Angle of Incidence on Negative Muon-Induced SEU Cross Sections of 65-nm Bulk and FDSOI SRAMs
Muon-induced single event upset is predicted to increase with technology scaling. Although previous works investigated the dependencies of muon-induced SEU cross sections on energy, voltage, and technology, the angle of incidence of terrestrial muons is not always perpendicular to the chip surface. Consequently, the impact of the angle of incidence of muons on SEUs should be evaluated. This study conducts negative muon irradiation tests on bulk and full depleted silicon on insulator static random-access memories at two angles of incidence: 0° (vertical) and 45° (tilted). The tilted incidence drifts the muon energy peak to a higher energy as expected. However, the SEU characteristics in the bulk device between the vertical and tilted incidences, including the voltage dependences of the SEU cross sections and multiple cells upset patterns, are similar despite the unexpected impact on the SEU cross section at an operating voltage of 0.4 V.
- 24 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (7) , 1566-1572
Impact of the Angle of Incidence on Negative Muon-Induced SEU Cross Sections of 65-nm Bulk and FDSOI SRAMs
Muon-induced single event upset is predicted to increase with technology scaling. Although previous works investigated the dependencies of muon-induced SEU cross sections on energy, voltage, and technology, the angle of incidence of terrestrial muons is not always perpendicular to the chip surface. Consequently, the impact of the angle of incidence of muons on SEUs should be evaluated. This study conducts negative muon irradiation tests on bulk and full depleted silicon on insulator static random-access memories at two angles of incidence: 0° (vertical) and 45° (tilted). The tilted incidence drifts the muon energy peak to a higher energy as expected. However, the SEU characteristics in the bulk device between the vertical and tilted incidences, including the voltage dependences of the SEU cross sections and multiple cells upset patterns, are similar despite the unexpected impact on the SEU cross section at an operating voltage of 0.4 V.