Chungsik Yoon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Chungsik Yoon has a total of 258 co-authors. Here are the top co-authors by number of shared publications:
Kiyoung Lee
Institute of Health and Environment, Graduate School of Public Health, Seoul National University, Seoul, Republic of Korea (South Korea)
14 shared publicationsSeunghon Ham
Department of Occupational and Environmental Medicine, Gil Medical Center, Gachon University College of Medicine, Incheon, Republic of Korea
11 shared publicationsDonguk Park
Department of Environmental Health, Korea National Open University, Seoul, Republic of Korea
8 shared publications- Jihoon Park
Division of Chemical Safety Management, Nakdong River Basin Environmental Office, Ministry of Environment
8 shared publications Jihoon Park
National Institute of Chemical Safety, Ministry of Environment, Republic of Korea
7 shared publicationsMyoungho Lee
Department of Environmental Health Sciences, Graduate School of Public Health, Seoul National University, Seoul, Republic of Korea
7 shared publications
Latest Publications
- Open Access
- 22 October 2026
- Published by Springer Nature in Scientific Reports
Evaluation of airborne PFAS concentrations in PFAS-using industrial facilities
- 22 October 2026
- Published by Springer Nature in Scientific Reports
Open AccessEvaluation of airborne PFAS concentrations in PFAS-using industrial facilities
- Open Access
- 5 September 2026
- Published by Elsevier in SSRN Electronic Journal
Heater architecture as a source-reduction factor for ultrafine particle and volatile organic compound emissions in industrial extrusion blow molding
Industrial polymer-processing environments can generate substantial ultrafine particle and volatile organic compound (VOC) burdens, yet the role of process-equipment architecture in reducing these emissions under matched operating conditions remains insufficiently quantified. This study evaluated heater architecture as an equipment-level source-reduction factor in full-scale polyolefin extrusion blow molding by comparing conventional band-heated (A-type) and radiant temperature-controlled (B-type) lines, together with a mechanically dominated regrind-disposal comparator. Integrated particle-size distribution (PSD), total suspended particles (TSP), total particle concentration (TPC), VOCs, microscopy, FTIR–ATR, Raman/photoluminescence, Raman mapping, and thermochemical diagnostics were used to characterize process-resolved airborne emission signatures. Under the A-type architecture, extrusion blow molding showed a dominant ultrafine mode near 80 nm, elevated TSP concentrations of 3.51–4.10 × 10⁴ µg·m⁻³, increased TPC of 3.06–3.56 × 10⁹ particles·cm⁻³, and stronger enrichment of alkane-, aromatic-, and oxygenated-VOC classes. Relative to the A-type system, the B-type architecture was associated with an approximately 70% reduction in dominant ultrafine peak intensity, a 64–73% reduction in TSP, a 67–75% reduction in TPC, and an 81–92% reduction in nano-particle number under extrusion blow-molding conditions. Regrind disposal showed fracture-dominated morphology, broader accumulation-to-coarse distributions, and minimal sustained ultrafine enrichment, indicating a mechanically dominated pathway distinct from melt-phase extrusion. These findings identify heater architecture as a practical process-equipment source-reduction factor for lowering airborne particle and VOC burdens in industrial indoor polymer-processing environments.
- 5 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessHeater architecture as a source-reduction factor for ultrafine particle and volatile organic compound emissions in industrial extrusion blow molding
Industrial polymer-processing environments can generate substantial ultrafine particle and volatile organic compound (VOC) burdens, yet the role of process-equipment architecture in reducing these emissions under matched operating conditions remains insufficiently quantified. This study evaluated heater architecture as an equipment-level source-reduction factor in full-scale polyolefin extrusion blow molding by comparing conventional band-heated (A-type) and radiant temperature-controlled (B-type) lines, together with a mechanically dominated regrind-disposal comparator. Integrated particle-size distribution (PSD), total suspended particles (TSP), total particle concentration (TPC), VOCs, microscopy, FTIR–ATR, Raman/photoluminescence, Raman mapping, and thermochemical diagnostics were used to characterize process-resolved airborne emission signatures. Under the A-type architecture, extrusion blow molding showed a dominant ultrafine mode near 80 nm, elevated TSP concentrations of 3.51–4.10 × 10⁴ µg·m⁻³, increased TPC of 3.06–3.56 × 10⁹ particles·cm⁻³, and stronger enrichment of alkane-, aromatic-, and oxygenated-VOC classes. Relative to the A-type system, the B-type architecture was associated with an approximately 70% reduction in dominant ultrafine peak intensity, a 64–73% reduction in TSP, a 67–75% reduction in TPC, and an 81–92% reduction in nano-particle number under extrusion blow-molding conditions. Regrind disposal showed fracture-dominated morphology, broader accumulation-to-coarse distributions, and minimal sustained ultrafine enrichment, indicating a mechanically dominated pathway distinct from melt-phase extrusion. These findings identify heater architecture as a practical process-equipment source-reduction factor for lowering airborne particle and VOC burdens in industrial indoor polymer-processing environments.
- 2 June 2026
- Published by Springer Nature in Air Quality, Atmosphere & Health
- Vol. 19 (6) , 132
Assessment and characteristics of target metal levels in consumer spray products
- 2 June 2026
- Published by Springer Nature in Air Quality, Atmosphere & Health
- Vol. 19 (6) , 132
Assessment and characteristics of target metal levels in consumer spray products
- Open Access
- 20 January 2026
- Published by Elsevier in Safety and Health at Work
- Vol. 17 (1) , 12-23
Distribution and Concentration of Airborne Per- and Polyfluoroalkyl Substances (PFAS) in Indoor and Outdoor Environments: A Systematic Review
- 20 January 2026
- Published by Elsevier in Safety and Health at Work
- Vol. 17 (1) , 12-23
Open AccessDistribution and Concentration of Airborne Per- and Polyfluoroalkyl Substances (PFAS) in Indoor and Outdoor Environments: A Systematic Review
- Open Access
- 5 November 2025
- Published by Elsevier in Safety and Health at Work
- Vol. 17 (1) , 127-133
Occupational Exposure Risk and Safety of Novel Intraperitoneal Oxaliplatin Delivery via Heated CO2 and Dual-flow Nozzle System
- 5 November 2025
- Published by Elsevier in Safety and Health at Work
- Vol. 17 (1) , 127-133
Open AccessOccupational Exposure Risk and Safety of Novel Intraperitoneal Oxaliplatin Delivery via Heated CO2 and Dual-flow Nozzle System
- Open Access
- 29 August 2025
- Published by Elsevier in Safety and Health at Work
- Vol. 16 (4) , 446-453
Chemical Exposure Assessment in Traditional Korean Pottery Workplaces
- 29 August 2025
- Published by Elsevier in Safety and Health at Work
- Vol. 16 (4) , 446-453
Open AccessChemical Exposure Assessment in Traditional Korean Pottery Workplaces
- Open Access
- 2 July 2025
- Published by Elsevier in Journal of Hazardous Materials Advances
- Vol. 19
Impact of simultaneous use of consumer spray products on airborne substances
- 2 July 2025
- Published by Elsevier in Journal of Hazardous Materials Advances
- Vol. 19
Open AccessImpact of simultaneous use of consumer spray products on airborne substances
- 29 May 2025
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 494, 138776
Particle and per- and polyfluoroalkyl substance (PFAS) concentrations from different types of fire extinguishers
- 29 May 2025
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 494, 138776
Particle and per- and polyfluoroalkyl substance (PFAS) concentrations from different types of fire extinguishers