KOKevin Glenn Owens

Kevin Glenn Owens

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kevin Glenn Owens has a total of 95 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Investigating the accuracy of simulated flight time and peak width data calculated using TOFSim, a LabVIEW based time-of-flight mass spectrometer simulation

    by Hannah M. Palmer, Kevin Glenn Owens

    This thesis consists of three sections focused on the application of TOFSim, a Time-of-Flight Mass Spectrometer (TOFMS) simulation. The first details minor changes that needed to be made to the TOFSim code in order for the program to run correctly with its expected capabilities. The main change involved rewriting the code modeling the production of ions using the matrix-assisted laser desorption ionization (MALDI) technique. The changes made allowed TOFSim to be used in the various experiments conducted in the other two sections of the thesis. The second section used TOFSim to generate flight times and peak widths that were compared to time-of-flight data taken on a physical instrument (a Bruker Autoflex III) in the linear configuration. This section showed how varying certain parameters is crucial to the user's ability to set up a simulated instrument in a way that matches a physical one. It details how adjusting the voltage in the source has a direct impact on peak width, and how the ions experience this environment as they move through the source in an ideal gridded instrument modeled by TOFSim as compared to the gridless real instrument. It was shown that TOFSim generates simulated TOF data that are accurate when compared to the measured data in linear mode. The third section uses TOFSim to simulate flight time and peak width but with the instrument in a reflectron configuration. The internal lengths of the reflector regions were determined and combined with the lengths of the source found in the previous section. In addition to adjusting the voltage applied in the source, the effect of the ion's initial velocity and position distributions on changes in peak width and flight time were observed. Changing the initial velocity standard deviation value, while holding the mean constant, broadened or narrowed the simulated peak width. Overall, it was demonstrated that both flight times and peak widths could be modeled accurately for the instrument operating in the reflectron configuration. While TOFSim was originally developed as a tool for teaching the principles of TOFMS, the work in this thesis has shown it can also be used as a research tool. It can be used to carry out "what if" experiments that would be impossible or very difficult to do on a physical instrument.

  • Open Access

    Use of TOFSim, a LabView-Based Time-of-Flight Mass Spectrometer Simulation, to Model Real Instrument Data

    by Hannah M. Palmer, Kevin G. Owens

    It is demonstrated here that a recently published LabView-based time-of-flight mass spectrometer (TOFMS) simulation program (named TOFSim) can accurately simulate data collected on a commercial Bruker Autoflex III matrix-assisted laser desorption/ionization (MALDI) TOFMS instrument operating in linear mode. Once the instrument distances are determined by matching measured and simulated flight times, it is shown that both overall flight times and peak widths are reproduced for data collected under both focused and slightly defocused conditions. This work confirms that TOFSim can be used not just for training new instrument operators in the principles of TOFMS but, as demonstrated here, to show how changing the voltage applied to grid G1 in the source or the delayed extraction delay time affects the focusing properties of the instrument. In the future we expect that this will also allow users to perform "what-if" experiments to investigate scenarios which may be difficult or impossible to do in a real instrument.

  • Investigations into the effects of electrospray deposition sample preparation parameters on analyte signal in MALDI MS imaging samples & correcting mass accuracy and signal intensity errors in a MALDI TOF mass spectrometer

    by Brian Malys, Kevin Glenn Owens

    The thesis consists of three sections. In the first, depth profiles are collected and used to investigate the effects of electrospray deposition (ESD) parameters on matrix deposition for matrix-assisted laser desorption ionization (MALDI) mass spectrometry imaging (MSI) samples. Various matrix deposition parameters including spray time, spray height and matrix identity were varied and the resulting signal of three analytes was collected in sequential spectra using a small number of laser shots. It was found that the spray parameters have a significant effect on the resulting analyte signal and its distribution throughout the matrix overlayer, with homogeneous and heterogeneous distributions of analyte signal observed. The differences in analyte distributions are explained using the fundamental principles of ESD. By identifying the sections of the matrix overlayer with the most analyte signal present, much higher quality MALDI MS images can be collected. In the second section, the use of ESD to apply matrix with an additional solvent spray to incorporate and homogenize analyte within the matrix overlayer was demonstrated. Prior to this incorporation spray, samples prepared using alpha-cyano-4-hydroxycinnamic acid (CHCA) and 2,5-dihydroxybenzoic acid (DHB) as the matrix showed low signal while the sample using sinapinic acid (SA) initially exhibited good signal. Following the incorporation spray, the sample using SA did not show an increase in signal, the sample using DHB showed moderate gains, while CHCA samples saw large increases in signal. The use of an incorporation spray to apply solvent by ESD to a matrix layer already deposited by ESD provides an increase in signal by both promoting incorporation of the analyte within and homogenizing the distribution of the incorporated analyte throughout the matrix layer. In the final section, ESD samples were used to determine the source of error in both mass accuracy and signal intensity in a MALDI time-of-flight (TOF) mass spectrometer (MS). This source of error was found to be due to small differences in the initial position of ions formed in the source region of the TOF MS. These differences arise largely from misalignment of the instrument sample stage, with a smaller contribution arising from the non-ideal shape of the target plates used. By physically measuring the target plates used and comparing TOF data collected from three different instruments, an estimate of the magnitude and direction of the sample stage misalignment was determined for each of the instruments. A correction method was developed to correct the TOFs and peak areas obtained for a given combination of target plate and instrument, significantly decreased the error observed.

  • Open Access

    Identification of Microbial Strains via 2D Cross-Correlation of LC-MS Data

    by Tucker James Collins, Cathy Muste, Kevin G. Owens

    Mass spectrometry is commonly used in the identification of species present in microbial samples, but the high similarity in the peptide composition between strains of a single species has made analysis at the subspecies level challenging. Prior research in this area has employed methods such as Principal Component Analysis (PCA), the k-Nearest Neighbors' (kNN) algorithm, and Pearson correlation. Previously, 1D cross-correlation of mass spectra has been shown to be useful in the classification of small molecule compounds as well as in the identification of peptide sequences via the SEQUEST algorithm and its variants. While direct application of cross-correlation to mass spectral data has been shown to aid in the identification of many other types of compounds, this type of analysis has not been demonstrated in the literature for the purpose of LC-MS based identification of microbial strains. A method of identifying microbial strains is presented here that applies the principle of 2D cross-correlation to LC-MS data. For a set of N = 30 yeast isolate samples representing 5 yeast strains (K-97, S-33, T-58, US-05, WB-06), high-resolution LC-MS-Orbitrap data were collected. Reference spectra were then generated for each strain from the combined data of each sample of that strain. Sample strains were then predicted by computing the 2D cross-correlation of each sample against the reference spectra, followed by application of correction factors measuring the asymmetry of the 2D correlation functions.


  • The Search for Heavy Metals in Nicotine E-liquid

    by Prairie Yang, Kevin Glenn Owens

    The goal of the work described in this thesis was to determine if there are detectable amounts of heavy metals in a selection of commercially available e-liquid samples. Both flame and graphite furnace atomic absorption spectroscopy were the methods of analysis employed. A set of preliminary experiments was conducted in order to develop a reproducible method for sample preparation. Once completed, a final set of experiments were performed to quantify the amount of several heavy metals in each e-liquid. The e-liquids analyzed were from the manufacturers Vaporfi, E-liquid Depot, Vuse, and JUUL. The metals detected in one or more of the e-liquids tested were copper, nickel, iron, chromium, aluminum, and vanadium.

  • Improving Mass Measurements in MALDI TOFMS by Measuring Initial Ion Position and The Investigation of Sample Preparation Parameters in the Cationization of Synthetic Polymers

    by Michelle Louise Piotrowski, Kevin Glenn Owens

    Mass spectra collected with a Bruker Autoflex III MALDI TOFMS were found to have poor intensity precision and mass accuracy. Both the within- and between-sample reproducibility of peak areas were significantly higher than results seen in previous work for samples deposited using electrospray deposition. A correlation between TOF peak area and sample location was observed. It was found that the misalignment of the instrument sample stage, multiple insertions and mountings of the target plate, and the different shapes of the sample plate were the four sources of variation in height along instrument flight axis. These changes in height produced reproducible changes in the measured ion TOF. In addition, a small but reproducible change in the position of the laser spot in the sample viewing camera image was observed, with the movement depending on both the sample position and target plate used. Using the change in coordinates of the laser position in the camera image and the known angle of incidence of the laser on the sample surface, the initial z-axis position of the ion at different locations on the sample plate can be calculated, exactly defining changes in the ion flight pathlength and the distance between the sample plate and first extraction plate/grid with sample position on the target plate. A correction method is developed to correct the TOF values collected from different locations on the sample plate using the laser images, with the relative standard deviation (RSD) of TOF being reduced from 23 ppm to below 6 ppm. The laser images, along with the measured target plate heights, are also used to calculate the absolute misalignment of the sample stage. A LabView based virtual instrument was used to simulate flight times of ions at various heights along the z-axis, which were compared with the measured flight times taken from the instrument. MALDI is a soft ionization technique often used to analyze synthetic polymer analytes and often a cationization agent is needed. For the analysis of a polymer analyte both amount and type of the matrix and cationization agent (termed "salt") should be considered. The choice of matrix must be compatible with the polymer; the matrix, polymer and cationization agent used must all be soluble in the solvent chosen. The cationization agent can improve the ion signal intensity with either the salt present in the sample or MALDI matrix as an impurity (as in the case of Na⁺ or K⁺) or added during the sample preparation process. Polymers, such as PEG have shown different affinities towards salt used and their selectivity can change as the matrix changes. Previous work in our group investigated the effect of salt-to-analyte (S/A) ratio for cationization for the polymer PMMA, looking at the choice of matrix and concentration of the salt. In some cases the addition of salt can decrease the signal intensity of the polymer analyte. S/A ratio plots are used in this work to investigate the effect of cationization agent concentration on the analysis of PEG with different matrices. The cationization agent used in this work is Cs+, and it was found that higher amounts of matrix were needed to improve the signal of the analyte. Several matrix clusters were observed in the low mass region of the mass spectra that could indicate a competition between the matrix and analyte for the cationization agent.

  • The quantitative aspects of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry

    by Russell R. Hensel, Kevin Glenn Owens

    The use of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI TOFMS) has largely been restricted to the area of qualitative analysis. We believe one of the major obstacles hindering the use of MALDI for quantitative applications lies in the method of sample preparation. In the research described herein, we present to the reader the aspects of conventional dried drop methods of sample preparation that lead to non-quantitative MALDI, or at best, highly subjective means of quantitation. We further suggest that electrospray sample preparation is a means by which samples may be prepared for more objective quantitative analysis using MALDI TOFMS. Experimental data is provided to support this notion. Additionally, reference calibration curves in neat solutions and from extracts of complex biological matrices are provided. Observations regarding the optimization of the electrospray preparation of samples for quantitative MALDI are also provided. The ability to perform quantitative analysis using electrospray sample preparation for MALDI TOFMS has also allowed us to initiate investigations into the relationships between peptide structure and MALDI ion signal intensities. These preliminary investigations have lead us to hypothesize that there is a positive relationship between the hydrophilicity of a peptide, the number of basic amino acid residues (including amino-terminal groups) contained within the peptide and the MALDI ion signal intensity of that peptide when the sample is prepared using electrospray sample preparation in 2,5-dihydroxybenzoic acid. Specific examples are presented along with the results of a multiple linear regression analysis summarizing the results from our initial investigations. An experimental outline of proposed future work is also presented.

  • Some quantitative aspects of the analysis of synthetic polymers by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry

    by Robert J. Goldschmidt, Kevin Glenn Owens

    Discrimination in the response of synthetic polymer samples in MALDI was investigated using two-component, low molecular weight polymer blends. A survey of several blends indicates that there are both mass and molecular weight distribution dependent parts of discrimination. The calculated blend component molecular weights and absolute and molar area responses reveal different aspects of discrimination and suggest some probable causes. A more detailed examination is made of a poly(ethylene glycol) blend system: PEG 1500/PEG 4600 using 2,5-dihydroxybenzoic acid (DHB) as matrix. A factorial experiment was performed about a center point of equal molar polymer amounts. PEG 1500 exhibited a linear increase in response with amount but the other factors tested affected the slope. PEG 1500 had no influence on the response of PEG 4600 and showed no interaction effects with the matrix amount or laser fluence. PEG 4600 exhibited saturation in its area response and had a strong inhibiting effect on the response of PEG 1500. It also influenced the effects of the matrix and laser fluence. The molar responses of the two blend components are unequal over much of the region of factor space investigated, but there is at least a limited region of minimal discrimination. The most important factor defining this region appears to be the high matrix level. Other experiments show that a nearly equal molar response can be maintained at even higher matrix levels, but that this is subject to the influence of the laser fluence level. The cation (sodium) level also affects the relative response and is another variable to consider in minimizing discrimination. The response saturation behavior of the two PEG components is consistent with an important, but probably not exclusive, influence of polymer aggregation on that effect and on the inhibiting effect of PEG 4600 on PEG 1500. The causes of response saturation and response inhibition are at least partially separable from the causes of unequal molar response. There are conditions under which the former affect the responses of both components in a proportional manner, while the latter must by definition affect the responses in a non-proportional manner.

  • Quantitative aspects of matrix-assisted laser desorption/ionization using electrospray deposition

    by Cynthia M. Chavez-Eng, Kevin Glenn Owens

    MALDI is routinely used as a soft-ionization technique in mass spectrometry for the qualitative analysis of biological and synthetic materials of a wide range of molecular weights. Recently, numerous groups have explored its use as a quantitative technique. The main limitation reported is in the irreproducibility of the collected mass spectra that was attributed to heterogeneity in the final MALDI samples resulting from the traditional air-dried drop method of sample deposition. In this research, the electrospray deposition technique was utilized to quantify proteins of moderate size, including insulin. Various sample cleanup methods were explored, and the use of sample additives (crown ethers) and buffer (ammonium salts) underlayers have shown to reduce the appearance of alkali adducts, yielding good quality MALDI spectra. Improvement of the electrospray deposition process for use in quantitative MALDI has also resulted in a better understanding of the MALDI process itself. Extensive analyses of quantitative mixtures of peptides (DDAVP/AVP) and proteins (bovine and porcine insulin) in a number of different matrices, namely sinapinic acid, ferulic acid, and 2,5-dihydroxybenzoic acid have demonstrated that MALDI is a mass sensitive technique. To maintain analyte signal, matrix concentration must decrease as the analyte concentration decreases. Each analyte studied possesses an optimum matrix-to-analyte ratio for analysis that varies with both analyte size and matrix choice. Analyte signal saturation is also observed and rationalized by experiment as a problem with the desorption rather than the ionization steps in the MALDI process. Problems encountered in the electrospray deposition of volatile MALDI matrices and their implications, and difficulties in the development of a quantitative MALDI method for the determination of insulin in biological sample will be discussed.