Paola Volonghi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Paola Volonghi has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Gabriele Baronio
University of Brescia
3 shared publications - Alberto Signoroni
University of Brescia
2 shared publications G. Rizzo
2 shared publicationsA. Cicchetti
1 shared publicationA. Messina
1 shared publicationAlberto Signoroni
1 shared publication
Latest Publications
- 22 January 2018
- Published by Taylor & Francis in Virtual and Physical Prototyping
- Vol. 13 (2) , 105-116
3D scanning and geometry processing techniques for customised hand orthotics: an experimental assessment
In the field of rehabilitation, the 3D scanning of body parts can be considered a crucial starting point for subsequent 3D model design of customised devices, especially when additive manufacturing techniques are involved in their production. This study experimentally evaluates and identifies appropriate procedures to acquire and process 3D anatomic images of the hand, including fingers, for the design of customised orthoses. Hand scanning is a complex activity and requires solutions capable of solving problematic aspects, such as the difficulty in maintaining the hand in a steady position and the presence of motion artefacts due to involuntary movements. We addressed such issues by considering the use of two different kinds of optical scanning device. The acquisition process has been initially defined based on healthy subjects and then extended to patients affected by pathologies that compromise upper limb functionality. Quality anatomical models were produced thanks to the application of advanced geometry processing technologies for the automated alignment of multiple scans and the removal of artefacts due to involuntary movements. As a result, with distinctive pros and cons, both the proposed combinations of scanning procedures and dedicated geometry processing evidenced their suitability in producing complete and accurate enough 3D models to be exploited for the subsequent design and production of customised hand orthoses in a typical reverse engineering pipeline.
- 22 January 2018
- Published by Taylor & Francis in Virtual and Physical Prototyping
- Vol. 13 (2) , 105-116
3D scanning and geometry processing techniques for customised hand orthotics: an experimental assessment
In the field of rehabilitation, the 3D scanning of body parts can be considered a crucial starting point for subsequent 3D model design of customised devices, especially when additive manufacturing techniques are involved in their production. This study experimentally evaluates and identifies appropriate procedures to acquire and process 3D anatomic images of the hand, including fingers, for the design of customised orthoses. Hand scanning is a complex activity and requires solutions capable of solving problematic aspects, such as the difficulty in maintaining the hand in a steady position and the presence of motion artefacts due to involuntary movements. We addressed such issues by considering the use of two different kinds of optical scanning device. The acquisition process has been initially defined based on healthy subjects and then extended to patients affected by pathologies that compromise upper limb functionality. Quality anatomical models were produced thanks to the application of advanced geometry processing technologies for the automated alignment of multiple scans and the removal of artefacts due to involuntary movements. As a result, with distinctive pros and cons, both the proposed combinations of scanning procedures and dedicated geometry processing evidenced their suitability in producing complete and accurate enough 3D models to be exploited for the subsequent design and production of customised hand orthoses in a typical reverse engineering pipeline.
- Open Access
- 6 November 2017
- Published by Wiley in Applied Bionics and Biomechanics
- Vol. 2017, 1-8
Concept and Design of a 3D Printed Support to Assist Hand Scanning for the Realization of Customized Orthosis
In the rehabilitation field, the use of additive manufacturing techniques to realize customized orthoses is increasingly widespread. Obtaining a 3D model for the 3D printing phase can be done following different methodologies. We consider the creation of personalized upper limb orthoses, also including fingers, starting from the acquisition of the hand geometry through accurate 3D scanning. However, hand scanning procedure presents differences between healthy subjects and patients affected by pathologies that compromise upper limb functionality. In this work, we present the concept and design of a 3D printed support to assist hand scanning of such patients. The device, realized with FDM additive manufacturing techniques in ABS material, allows palmar acquisitions, and its design and test are motivated by the following needs: (1) immobilizing the hand of patients during the palmar scanning to reduce involuntary movements affecting the scanning quality and (2) keeping hands open and in a correct position, especially to contrast the high degree of hypertonicity of spastic subjects. The resulting device can be used indifferently for the right and the left hand; it is provided in four-dimensional sizes and may be also suitable as a palmar support for the acquisition of the dorsal side of the hand.
- 6 November 2017
- Published by Wiley in Applied Bionics and Biomechanics
- Vol. 2017, 1-8
Open AccessConcept and Design of a 3D Printed Support to Assist Hand Scanning for the Realization of Customized Orthosis
In the rehabilitation field, the use of additive manufacturing techniques to realize customized orthoses is increasingly widespread. Obtaining a 3D model for the 3D printing phase can be done following different methodologies. We consider the creation of personalized upper limb orthoses, also including fingers, starting from the acquisition of the hand geometry through accurate 3D scanning. However, hand scanning procedure presents differences between healthy subjects and patients affected by pathologies that compromise upper limb functionality. In this work, we present the concept and design of a 3D printed support to assist hand scanning of such patients. The device, realized with FDM additive manufacturing techniques in ABS material, allows palmar acquisitions, and its design and test are motivated by the following needs: (1) immobilizing the hand of patients during the palmar scanning to reduce involuntary movements affecting the scanning quality and (2) keeping hands open and in a correct position, especially to contrast the high degree of hypertonicity of spastic subjects. The resulting device can be used indifferently for the right and the left hand; it is provided in four-dimensional sizes and may be also suitable as a palmar support for the acquisition of the dorsal side of the hand.
- Open Access
- 1 April 2016
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 119, S875-S876
EP-1858: Variation of apparent diffusion coefficient in penile bulb after radiotherapy
- 1 April 2016
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 119, S875-S876
Open AccessEP-1858: Variation of apparent diffusion coefficient in penile bulb after radiotherapy
- 1 February 2016
- Published by Elsevier in Physica Medica
- Vol. 32, 134
Accuracy comparison of two different optimization algorithms for direct bi-exponential analysis of IVIM MRI images
- 1 February 2016
- Published by Elsevier in Physica Medica
- Vol. 32, 134
Accuracy comparison of two different optimization algorithms for direct bi-exponential analysis of IVIM MRI images
- Open Access
- 10 March 2015
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 75 (2) , 873-882
Automatic extraction of three‐dimensional thoracic aorta geometric model from phase contrast MRI for morphometric and hemodynamic characterization
Purpose: To propose and assess a new method that automatically extracts a three‐dimensional (3D) geometric model of the thoracic aorta (TA) from 3D cine phase contrast MRI (PCMRI) acquisitions.Methods: The proposed method is composed of two steps: segmentation of the TA and creation of the 3D geometric model. The segmentation algorithm, based on Level Set, was set and applied to healthy subjects acquired in three different modalities (with and without SENSE reduction factors). Accuracy was evaluated using standard quality indices. The 3D model is characterized by the vessel surface mesh and its centerline; the comparison of models obtained from the three different datasets was also carried out in terms of radius of curvature (RC) and average tortuosity (AT).Results: In all datasets, the segmentation quality indices confirmed very good agreement between manual and automatic contours (average symmetric distance < 1.44 mm, DICE Similarity Coefficient > 0.88). The 3D models extracted from the three datasets were found to be comparable, with differences of less than 10% for RC and 11% for AT.Conclusion: Our method was found effective on PCMRI data to provide a 3D geometric model of the TA, to support morphometric and hemodynamic characterization of the aorta. Magn Reson Med 75:873–882, 2016.
- 10 March 2015
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 75 (2) , 873-882
Open AccessAutomatic extraction of three‐dimensional thoracic aorta geometric model from phase contrast MRI for morphometric and hemodynamic characterization
Purpose: To propose and assess a new method that automatically extracts a three‐dimensional (3D) geometric model of the thoracic aorta (TA) from 3D cine phase contrast MRI (PCMRI) acquisitions.Methods: The proposed method is composed of two steps: segmentation of the TA and creation of the 3D geometric model. The segmentation algorithm, based on Level Set, was set and applied to healthy subjects acquired in three different modalities (with and without SENSE reduction factors). Accuracy was evaluated using standard quality indices. The 3D model is characterized by the vessel surface mesh and its centerline; the comparison of models obtained from the three different datasets was also carried out in terms of radius of curvature (RC) and average tortuosity (AT).Results: In all datasets, the segmentation quality indices confirmed very good agreement between manual and automatic contours (average symmetric distance < 1.44 mm, DICE Similarity Coefficient > 0.88). The 3D models extracted from the three datasets were found to be comparable, with differences of less than 10% for RC and 11% for AT.Conclusion: Our method was found effective on PCMRI data to provide a 3D geometric model of the TA, to support morphometric and hemodynamic characterization of the aorta. Magn Reson Med 75:873–882, 2016.