Niraj V. Kalore
Niraj V. Kalore has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Jasvinder A. Singh
Medicine Service, Michael E. DeBakey VA Medical Center
3 shared publications - Edward Y. Cheng
Department of Orthopaedic Surgery, University of Minnesota, Minneapolis, USA
2 shared publications Aditya Maheshwari
University of Minnesota Medical School
1 shared publicationAditya V. Maheshwari
Department of Orthopedics, University of Minnesota Medical Center, R200, 2450 Riverside Ave S, Minneapolis, Minnesota 55454, USA
1 shared publication- Alexis Jorgensen
Virginia Commonwealth University Medical Center
1 shared publication Amit Sharma
University of Minnesota Medical School
1 shared publication
Latest Publications
- 1 January 2023
- Published by Springer Nature
- p. 1-10
Kinematics of the Native and Arthritic Knee
- 27 June 2022
- Published by Open Medical Publishing in Orthopedic Reviews
- Vol. 14 (3) , 35502
Comparative Analysis of Contemporary Fixed Tibial Inserts: A Systematic Review and Network Meta-analysis of Randomized Controlled Trials
Background: Multiple options are available for the tibial insert in total knee arthroplasty (TKA). A systematic review (SR) and network meta-analysis (NMA) to compare available randomized controlled trials (RCTs) could assist with decision making. We aim to show that designs with increased conformity may improve function and satisfaction without an increase in complications though posterior stabilized (PS) inserts will likely have more flexion. Methods: A search of MEDLINE, EMBASE, and the Cochrane Library was performed. Studies were limited to RCTs evaluating cruciate retaining (CR), PS, anterior stabilized (AS), medial pivot (MP), bicruciate retaining (BR), and bicruciate stabilizing (BCS) inserts. Mean differences (MD) were used for patient reported outcome measures (PROMs) and odds ratios (OR) for reoperation rates and MUA. A systematic review was performed for satisfaction. Results: 27 trials were identified. The NMA showed no difference from a statistical or clinical standpoint for PROMs evaluated. There was a statistical difference for increased flexion for PS knees (3 degrees p 0.04). There were no differences in the MUA or reoperation rates. There was insufficient information to determine if a specific insert improved satisfaction. Discussion: The results of this NMA show no statistical or clinical difference in PROMs. There was higher flexion for PS knees though the amount was not clinically significant. There was insufficient data for conclusions on patient satisfaction. Therefore, the surgeon should evaluate the clinical situation to determine the best insert rather than choose and insert based on functional scores, patient satisfaction, or complication rates.
- 27 June 2022
- Published by Open Medical Publishing in Orthopedic Reviews
- Vol. 14 (3) , 35502
Comparative Analysis of Contemporary Fixed Tibial Inserts: A Systematic Review and Network Meta-analysis of Randomized Controlled Trials
Background: Multiple options are available for the tibial insert in total knee arthroplasty (TKA). A systematic review (SR) and network meta-analysis (NMA) to compare available randomized controlled trials (RCTs) could assist with decision making. We aim to show that designs with increased conformity may improve function and satisfaction without an increase in complications though posterior stabilized (PS) inserts will likely have more flexion. Methods: A search of MEDLINE, EMBASE, and the Cochrane Library was performed. Studies were limited to RCTs evaluating cruciate retaining (CR), PS, anterior stabilized (AS), medial pivot (MP), bicruciate retaining (BR), and bicruciate stabilizing (BCS) inserts. Mean differences (MD) were used for patient reported outcome measures (PROMs) and odds ratios (OR) for reoperation rates and MUA. A systematic review was performed for satisfaction. Results: 27 trials were identified. The NMA showed no difference from a statistical or clinical standpoint for PROMs evaluated. There was a statistical difference for increased flexion for PS knees (3 degrees p 0.04). There were no differences in the MUA or reoperation rates. There was insufficient information to determine if a specific insert improved satisfaction. Discussion: The results of this NMA show no statistical or clinical difference in PROMs. There was higher flexion for PS knees though the amount was not clinically significant. There was insufficient data for conclusions on patient satisfaction. Therefore, the surgeon should evaluate the clinical situation to determine the best insert rather than choose and insert based on functional scores, patient satisfaction, or complication rates.
- 1 September 2020
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 102 (23) , e130
Automatic Characterization of Pelvic and Sacral Measures from 200 Subjects
Background: An understanding of pelvic and acetabular morphology and orientation is required for accurate surgical reconstruction of the hip and spine, as well for component placement in a total hip arthroplasty. Our objectives were to develop an automated system for measuring pelvic and sacral orientations utilizing computed tomographic (CT) scans and to characterize these measures across 200 asymptomatic subjects. Methods: An automated feature recognition algorithm was created to identify acetabular and pelvic orientation across 200 scans generated for non-musculoskeletal conditions. Three-dimensional models were generated from CT data to serve as inputs to the algorithm. Acetabular orientation was defined by comparing a plane fit to the acetabular rim with the anterior pelvic plane. Pelvic inclination, pelvic tilt, and sacral slope were defined as the angles between landmarks identified across the pelvis: pubic tubercles, acetabular center, left and right anterior superior iliac spines, and sacral plate. Results: The mean sacral slope was 36.49°, the mean pelvic tilt was 15.60°, and the mean pelvic incidence was 52.05°. The mean sacropubic angle was 32.48° and the mean pelvic-Lewinnek angle was 8.93°. Significant differences between male and female subjects were observed in the sacral slope (mean difference, 4.72°; p < 0.05), pelvic tilt α (mean difference, 4.17°; p < 0.05), pelvic tilt γ (mean difference, 3.06°; p < 0.05), and the pelvic-Lewinnek angle (mean difference, 1.76°; p < 0.05). The comparison of acetabular orientation measures with those in a prior study of the same cohort yielded intraclass correlation coefficients (ICCs) all above 0.97. The validation of sacral orientation via manual measurement also yielded ICC values all at or above 0.97. Conclusions: Our algorithm showed a high degree of consistency in acetabular orientation measures with respect to a prior study of the same cohort. The measures of pelvic orientation were found to be accurate and reliable when compared with manual measurements of the same data set. All measurements of pelvic orientation were consistent with the means reported in the literature. Clinical Relevance: An accurate and reproducible, automated technique for determining pelvic and acetabular orientation provides a way to characterize these measures as an aid in clinical diagnosis and preoperative planning.
- 1 September 2020
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 102 (23) , e130
Automatic Characterization of Pelvic and Sacral Measures from 200 Subjects
Background: An understanding of pelvic and acetabular morphology and orientation is required for accurate surgical reconstruction of the hip and spine, as well for component placement in a total hip arthroplasty. Our objectives were to develop an automated system for measuring pelvic and sacral orientations utilizing computed tomographic (CT) scans and to characterize these measures across 200 asymptomatic subjects. Methods: An automated feature recognition algorithm was created to identify acetabular and pelvic orientation across 200 scans generated for non-musculoskeletal conditions. Three-dimensional models were generated from CT data to serve as inputs to the algorithm. Acetabular orientation was defined by comparing a plane fit to the acetabular rim with the anterior pelvic plane. Pelvic inclination, pelvic tilt, and sacral slope were defined as the angles between landmarks identified across the pelvis: pubic tubercles, acetabular center, left and right anterior superior iliac spines, and sacral plate. Results: The mean sacral slope was 36.49°, the mean pelvic tilt was 15.60°, and the mean pelvic incidence was 52.05°. The mean sacropubic angle was 32.48° and the mean pelvic-Lewinnek angle was 8.93°. Significant differences between male and female subjects were observed in the sacral slope (mean difference, 4.72°; p < 0.05), pelvic tilt α (mean difference, 4.17°; p < 0.05), pelvic tilt γ (mean difference, 3.06°; p < 0.05), and the pelvic-Lewinnek angle (mean difference, 1.76°; p < 0.05). The comparison of acetabular orientation measures with those in a prior study of the same cohort yielded intraclass correlation coefficients (ICCs) all above 0.97. The validation of sacral orientation via manual measurement also yielded ICC values all at or above 0.97. Conclusions: Our algorithm showed a high degree of consistency in acetabular orientation measures with respect to a prior study of the same cohort. The measures of pelvic orientation were found to be accurate and reliable when compared with manual measurements of the same data set. All measurements of pelvic orientation were consistent with the means reported in the literature. Clinical Relevance: An accurate and reproducible, automated technique for determining pelvic and acetabular orientation provides a way to characterize these measures as an aid in clinical diagnosis and preoperative planning.
- 1 February 2019
- Published by Wiley in Arthroscopy
- Vol. 35 (2) , 657-658
Editorial Commentary: Hip Arthroscopy—The Tissue‐Friendly Evolution
The field of hip arthroscopy is saturated with low‐level studies. A systematic review of these low‐level studies provides low‐level evidence favoring tissue‐friendly restorative techniques such as labral repair and capsular repair over nonrestorative techniques such as labral debridement and capsulotomy. Iatrogenic complications such as nerve injuries and heterotopic ossification remain the most common complications of hip arthroscopy. This indicates that there is a further scope in improving the safety of hip arthroscopy. There is a need for innovative, well‐designed benchtop and high‐level clinical studies for rapid advancement in hip arthroscopy techniques.
- 1 February 2019
- Published by Wiley in Arthroscopy
- Vol. 35 (2) , 657-658
Editorial Commentary: Hip Arthroscopy—The Tissue‐Friendly Evolution
The field of hip arthroscopy is saturated with low‐level studies. A systematic review of these low‐level studies provides low‐level evidence favoring tissue‐friendly restorative techniques such as labral repair and capsular repair over nonrestorative techniques such as labral debridement and capsulotomy. Iatrogenic complications such as nerve injuries and heterotopic ossification remain the most common complications of hip arthroscopy. This indicates that there is a further scope in improving the safety of hip arthroscopy. There is a need for innovative, well‐designed benchtop and high‐level clinical studies for rapid advancement in hip arthroscopy techniques.
- 1 September 2016
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 31 (9) , 1894-1898
Acetabular Dysplasia in Middle-Aged Patients: Periacetabular Osteotomy or Total Hip Arthroplasty?
- 1 September 2016
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 31 (9) , 1894-1898
Acetabular Dysplasia in Middle-Aged Patients: Periacetabular Osteotomy or Total Hip Arthroplasty?
- 1 May 2015
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 30 (5) , 818-821
Revision TKA for Flexion Instability Improves Patient Reported Outcomes
- 1 May 2015
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 30 (5) , 818-821
Revision TKA for Flexion Instability Improves Patient Reported Outcomes
- 3 September 2013
- Published by Wiley in Cochrane Database of Systematic Reviews
- No. 9
Total hip replacement surgery versus conservative care for hip osteoarthritis and other non-traumatic diseases
- 3 September 2013
- Published by Wiley in Cochrane Database of Systematic Reviews
- No. 9
Total hip replacement surgery versus conservative care for hip osteoarthritis and other non-traumatic diseases
- 1 December 2012
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 470 (12) , 3406-3413
Save the Torn Labrum in Hips With Borderline Acetabular Coverage
Hip arthroscopy for labral tears improves short-term function, but reoperations occur in 5% to 47% of patients. The effect of borderline acetabular coverage on reoperation rate has been debated. Labral repair rather than débridement has been proposed to improve function, but the effect on reoperation rate is unclear. We determined whether (1) borderline compared to adequate acetabular coverage increased reoperations and (2) labral repair compared to débridement reduced reoperations. We retrospectively reviewed 106 patients (mean age, 39 years) who underwent hip arthroscopy for labral tears. Based on radiographs, we classified patients into those with borderline (n = 50) or adequate (n = 56) acetabular coverage. We further divided each group into those with labral débridement or repair: borderline acetabular coverage, n = 25 and 25, respectively; adequate acetabular coverage, n = 39 and 17, respectively. We assessed reoperations in borderline versus adequate acetabular coverage and labral débridement versus repair, modified Harris hip scores (mHHSs), and survival. Minimum followup was 12 months (mean, 33 months; range, 12–65 months). Twenty-three of 106 patients had reoperations. Reoperation rate was higher with borderline than with adequate acetabular coverage. Reoperation rate was lower with labral repair than with débridement. Survival to reoperation was similar in the four subgroups although there was a tendency for early reoperation in patients with borderline acetabular coverage with débridement. Improvement in mean mHHS was comparable in the four subgroups. We found borderline acetabular coverage increased reoperation rates. Labral repair reduced the likelihood of reoperation, especially in hips with borderline acetabular coverage. Hip arthroscopy for labral tears was associated with high reoperation rates in hips with borderline acetabular coverage. Level IV, prognostic study. See Instructions for Authors for a complete description of levels of evidence.
- 1 December 2012
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 470 (12) , 3406-3413
Save the Torn Labrum in Hips With Borderline Acetabular Coverage
Hip arthroscopy for labral tears improves short-term function, but reoperations occur in 5% to 47% of patients. The effect of borderline acetabular coverage on reoperation rate has been debated. Labral repair rather than débridement has been proposed to improve function, but the effect on reoperation rate is unclear. We determined whether (1) borderline compared to adequate acetabular coverage increased reoperations and (2) labral repair compared to débridement reduced reoperations. We retrospectively reviewed 106 patients (mean age, 39 years) who underwent hip arthroscopy for labral tears. Based on radiographs, we classified patients into those with borderline (n = 50) or adequate (n = 56) acetabular coverage. We further divided each group into those with labral débridement or repair: borderline acetabular coverage, n = 25 and 25, respectively; adequate acetabular coverage, n = 39 and 17, respectively. We assessed reoperations in borderline versus adequate acetabular coverage and labral débridement versus repair, modified Harris hip scores (mHHSs), and survival. Minimum followup was 12 months (mean, 33 months; range, 12–65 months). Twenty-three of 106 patients had reoperations. Reoperation rate was higher with borderline than with adequate acetabular coverage. Reoperation rate was lower with labral repair than with débridement. Survival to reoperation was similar in the four subgroups although there was a tendency for early reoperation in patients with borderline acetabular coverage with débridement. Improvement in mean mHHS was comparable in the four subgroups. We found borderline acetabular coverage increased reoperation rates. Labral repair reduced the likelihood of reoperation, especially in hips with borderline acetabular coverage. Hip arthroscopy for labral tears was associated with high reoperation rates in hips with borderline acetabular coverage. Level IV, prognostic study. See Instructions for Authors for a complete description of levels of evidence.
- 1 January 2012
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 470 (1) , 228-235
Is There a Preferred Articulating Spacer Technique for Infected Knee Arthroplasty?: A Preliminary Study
Periprosthetic infection in TKA is a devastating and challenging problem for both patients and surgeons. Two-stage exchange arthroplasty with an interval antibiotic spacer reportedly has the highest infection control rate. Studies comparing static spacers with articulating spacers have reported varying ROM after reimplant, which could be due to differences in articulating spacer technique. We therefore determined whether one of three articulating spacer techniques was superior in terms of (1) infection control, (2) final ROM, and (3) cost. We retrospectively reviewed 53 patients with infected TKAs who had two-stage exchange arthroplasty with one of three techniques with articulating spacers: autoclaving an original component (n = 15), a new femoral component (n = 16), and a silicone mold component (n = 22). We compared infection control, ROM, and cost. Minimum followup was 12 months (mean, 39 months; range, 12–105 months). We found no difference in infection control among the three techniques. Infection control was achieved in 13 of 15 (86.7%) autoclaved original component spacers at mean 73 months (range, 37–105 months), 15 of 16 (93.8%) new femoral component spacers at mean 19 months (range, 12–32 months), and 20 of 22 (90.9%) silicone mold component spacers at mean 32 months (range, 14–56 months). Mean final flexion was 95.7°, 98.3°, and 93.8°, respectively. Direct costs for all implants, molds, cement, and antibiotics were $932, $3589, and $3945, respectively. We found comparable infection control and ROM for the three techniques. Direct cost was least for the autoclaved original component technique. Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
- 1 January 2012
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 470 (1) , 228-235
Is There a Preferred Articulating Spacer Technique for Infected Knee Arthroplasty?: A Preliminary Study
Periprosthetic infection in TKA is a devastating and challenging problem for both patients and surgeons. Two-stage exchange arthroplasty with an interval antibiotic spacer reportedly has the highest infection control rate. Studies comparing static spacers with articulating spacers have reported varying ROM after reimplant, which could be due to differences in articulating spacer technique. We therefore determined whether one of three articulating spacer techniques was superior in terms of (1) infection control, (2) final ROM, and (3) cost. We retrospectively reviewed 53 patients with infected TKAs who had two-stage exchange arthroplasty with one of three techniques with articulating spacers: autoclaving an original component (n = 15), a new femoral component (n = 16), and a silicone mold component (n = 22). We compared infection control, ROM, and cost. Minimum followup was 12 months (mean, 39 months; range, 12–105 months). We found no difference in infection control among the three techniques. Infection control was achieved in 13 of 15 (86.7%) autoclaved original component spacers at mean 73 months (range, 37–105 months), 15 of 16 (93.8%) new femoral component spacers at mean 19 months (range, 12–32 months), and 20 of 22 (90.9%) silicone mold component spacers at mean 32 months (range, 14–56 months). Mean final flexion was 95.7°, 98.3°, and 93.8°, respectively. Direct costs for all implants, molds, cement, and antibiotics were $932, $3589, and $3945, respectively. We found comparable infection control and ROM for the three techniques. Direct cost was least for the autoclaved original component technique. Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.