WAWan Fatinhamamah Wan Ahmad

Wan Fatinhamamah Wan Ahmad

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Wan Fatinhamamah Wan Ahmad has a total of 61 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Designing Equitable Dynamic Electricity Tariffs: A Multi-Stage Machine Learning Approach

    by Tasmeea Rahman, Mohammad Lutfi Othman, Samsul Bahari Mohd Noor, Wan Fatinhamamah Wan Ahmad, Mohamad Fani Sulaima, Syed Zahurul Islam

    Dynamic electricity tariff programmes are critical for effective demand-side management, yet existing analytical approaches typically address consumer segmentation, load forecasting, and tariff design in isolation. This paper addresses this fragmentation by presenting a comprehensive five-stage machine learning pipeline. The methodology integrates dual-stage Rough Set Theory (RST) for feature selection alongside an Adaptive Rough K-Means (ARKM) clustering algorithm featuring a novel boundary region metric to handle consumer assignment ambiguity. This is followed by a hybrid deep learning forecasting architecture fusing Deep Belief Networks, BiLSTM, and a Transformer encoder. Finally, a three-objective NSGA-II evolutionary algorithm optimises tariffs to concurrently minimise consumer cost, peak-to-average ratio, and fairness variance. The framework was rigorously evaluated against twenty established baseline models across five highly diverse international smart meter datasets. Results demonstrate that the dual-RST approach reduced feature dimensionality by up to 64.3 percent without information loss. Furthermore, the hybrid forecasting architecture ranked first globally among all twenty-one considered pipelines (Friedman test p < 0.001). Crucially, the multi-objective tariff optimisation achieved up to 80.3 percent mean consumer cost savings, which is more than double the best-performing baseline, while maintaining a perfectly equitable Jain's Fairness Index of 1.000 on specific datasets and satisfying strict utility revenue neutrality constraints. By achieving a vastly superior composite end-to-end score, this framework provides electrical utilities with an interpretable and deployable pathway from raw smart meter data to personalised dynamic tariffs.

  • Open Access

    Designing Equitable Dynamic Electricity Tariffs: A Multi-Stage Machine Learning Approach

    by Tasmeea Rahman, Mohammad Lutfi Othman, Samsul Bahari Mohd Noor, Wan Fatinhamamah Wan Ahmad, Mohamad Fani Sulaima, Syed Zahurul Islam

    Dynamic electricity tariff programmes are critical for effective demand-side management, yet existing analytical approaches typically address consumer segmentation, load forecasting, and tariff design in isolation. This paper addresses this fragmentation by presenting a comprehensive five-stage machine learning pipeline. The methodology integrates dual-stage Rough Set Theory (RST) for feature selection alongside an Adaptive Rough K-Means (ARKM) clustering algorithm featuring a novel boundary region metric to handle consumer assignment ambiguity. This is followed by a hybrid deep learning forecasting architecture fusing Deep Belief Networks, BiLSTM, and a Transformer encoder. Finally, a three-objective NSGA-II evolutionary algorithm optimises tariffs to concurrently minimise consumer cost, peak-to-average ratio, and fairness variance. The framework was rigorously evaluated against twenty established baseline models across five highly diverse international smart meter datasets. Results demonstrate that the dual-RST approach reduced feature dimensionality by up to 64.3 percent without information loss. Furthermore, the hybrid forecasting architecture ranked first globally among all twenty-one considered pipelines (Friedman test p < 0.001). Crucially, the multi-objective tariff optimisation achieved up to 80.3 percent mean consumer cost savings, which is more than double the best-performing baseline, while maintaining a perfectly equitable Jain's Fairness Index of 1.000 on specific datasets and satisfying strict utility revenue neutrality constraints. By achieving a vastly superior composite end-to-end score, this framework provides electrical utilities with an interpretable and deployable pathway from raw smart meter data to personalised dynamic tariffs.

  • Computational Electromagnetic Modeling and Optimization Techniques to Enhance the Accuracy and Efficiency of a 2.45 GHz Pyramidal Horn Antenna by Newton–Raphson Method for IEMI Testing

    by Fuad Hamamah, Wfh Wan Ahmad, C. Gomes, M. Mohd Isa, M. J. Homam

    This paper presents computational electromagnetic techniques that can be effectively used to improve the accuracy and efficiency of designing a 2.45[ ]GHz pyramidal horn antenna for high-power microwave applications. The design parameters were determined using analytical methods, and optimization techniques were conducted with CST Microwave Studio. The highest antenna gain achieved was 19.89[ ]dBi, which is comparable to the proposed numerical value of 20[ ]dBi. The return loss of the horn antenna was calculated numerically and found to be [ ] [ ]dB, with a resonance frequency of 2.45[ ]GHz. The Voltage Standing Wave Ratio (VSWR) was measured to be less than 1.5, while the time required for the analysis was 120[ ]min, and the storage needed was 17 GB. Using CST Microwave Studio and optimization techniques, the return losses for the Genetic Algorithm (GA), Particle Swarm Optimization (PSO), Interior Point Quadratic Newton (IPQN), and Covariance Matrix Adaptation Evolution Strategy (CMA-ES) were −29.61[ ]dB, −30.45[ ]dB, −26.2[ ]dB, and −30.24[ ]dB, respectively. The corresponding VSWR values for GA, PSO, IPQN, and CMA-ES were 1.491, 1.42, 1.141, and 1.13. The gains for the same methods were found to be 20.3[ ]dBi, 20.2[ ]dBi, 19.8[ ]dBi, and 20[ ]dBi, respectively. This demonstrates that CST Microwave Studio effectively optimizes return loss, VSWR, and gain. In comparison to the GA optimizer, which required 3876[ ]min and 29[ ]s with a storage capacity of 23.4[ ]GB to perform 145 evaluations, the PSO optimizer took 7055[ ]min and 5[ ]s to complete 241 evaluations, needing 36[ ]GB of storage. Additionally, compared to CMA-ES, which utilized 26[ ]GB of storage to finish 186 evaluations in 6131[ ]min and 42 s, IPQN required only 155[ ]min and 44[ ]s with 24.6[ ]GB of storage to complete 3729 evaluations.

  • Methods and attributes for customer-centric dynamic electricity tariff design: A review

    by Tasmeea Rahman, Mohammad Lutfi Othman, Samsul Bahari Mohd Noor, Wan Fatinhamamah Binti Wan Ahmad, Mohamad Fani Sulaima


  • High power microwave devices: Development since 1880

    by F Hamamah, W F H Wan Ahmad, C Gomes, M Mohd Isa, M J Homam

    High power microwave systems have emerged as a promising new technology that has many applications, which include high power radar, directed energy weapons, laboratory sources for susceptibility and vulnerability testing of electronic systems. These systems are built, applied, and studied in many developed countries such as in United States of America and China. In the recent years, other countries such as Russia, Western Europe, Japan, Taiwan, India, South Korea, and Singapore have also entered the research spheres. In this paper an introduction to the emergence of HPM and the sequential evolution of the technology, that plays an important role in several applications, are discussed. The discussion extends to types of HPM sources, and their effects of electromagnetic interference on electronic systems.


  • Natural materials as grounding filler for lightning protection system

    by J. Jasni, L. K. Siow, M. Z. A Ab Kadir, W. F Wan Ahmad

    Grounding resistance could significantly reduce with the usage of grounding filler for grounding rod in lightning protection system. However, the cost of the normally used grounding fillers such as bentonite and other chemicals is the main drawback. Therefore, it is an aim of this study to determine the electrical properties and durability of natural grounding fillers as an alternative to bentonite. The 61.8% rule from the fall of potential method was used to obtain values of grounding resistance of the lightning protection system installed with natural grounding fillers such as bentonite, coconut coir peat, planting-clay soil and paddy dust. The measured grounding resistances were then compared with the grounding resistance of the reference grounding rod. Results revealed that natural materials especially planting-clay soil is the best alternative to replace bentonite as grounding filler because it gave the lowest grounding resistance values at the end of the experiment and had generally the highest percentage reduction in grounding resistance.


  • A review on optimal location of distributed generation techniques in electrical network

    by Zahraa Abdul Kareem, Wan Fatinhamamah Wan Ahmad, Jasronita Jasni, Noor Izzri Abd. Wahab

    To increase the maximum possible benefits of technical, economic and environmental aspects, the optimal sizing and sitting of distributed generation in distribution system has always been challenging for customers as well as to utilities. The objective of optimum sitting of distributed generation in a distribution system is to reach suitable operation of such systems with minimization losses of the systems, voltage profile improvement, enhanced system load ability, stability and reliability. In this paper, a review of techniques for optimum sitting of distributed generation units in distribution systems and study their effects on customers and utilities are presented. Also, a comparison was done between methods for optimum location of distributed generation in distribution systems.


  • Characteristics of fulgurite-like structures under HV conditions: Effects on electrical earthing systems

    by Zulkifli bin Burhanuddin, Chandima Gomes, Ashen Gomes, M Z K Ab Kadir, Wan Fatinhamamah Wan Ahmad, Norhafiz Azis

    Fulgurites are natural tubes of glass formed by the fusion of silica sand or rock from a lightning strike. The fulgurites have been produced artificially in HV conditions in the past. Recent studies have found that fulguritic structures can be formed in some other materials, such as bentonite and cement, as well. These fulgurites can change the overall physical and electrical properties of the original materials. Thus, formation of fulgurites can modify the performance of electrical earthing systems, both ordinary and those improvised with backfill materials. This study investigates the fulgurite formation under alternating, direct and impulse current application. Bentonite and sand were tested under high voltage conditions. The type of fulgurites and their effects on electrical earthing systems were studied by analyzing the resistivity and permittivity of original materials and fulgurites. It has been found that fulgurites formation has a severe effect on the earth resistance of grounding systems.


  • Effect of earth grid conductor spacing on the safety criteria of substation earthing

    by S. D. Buba, W. F. Wan Ahmad, M. Z. A. Ab Kadir, C. Gomes, J. Jasni, M. Osman

    Site dependent parameters such as soil resistivity, maximum grid current, fault duration, shock duration, surface layer material resistivity, and grid geometry have substantial impact on the design and performance of an earth grid. The grid geometry, i.e. the area occupied by the grid system, conductor spacing and the depth of burial of earth grid specifically have much impact on the mesh, step, touch voltage and earth potential rise, while parameters such as the conductor diameter and the thickness of the surfacing material have less impact on the safety criteria. In this paper, a distribution substation earth grid was designed using the CDEGS software by varying the spacing between grid conductors (compression ratio) from 1 to 0.5 in steps of 0.1. The safety criteria were studied under three scenarios, without surface layer material, with surface layer material of resistivity 3000Ω-m, and surface layer material of resistivity 5000Ω-m. Results indicated that the grid resistance and earth potential rise were lower for a compression ratio 0.9, while the step and touch voltages were found to be similar for each case of surface layer material.


  • Impact of energization current on the safe design of distribution substation earth grid

    by D. Buba, W. F. Wan Ahmad, M. Z. A. Ab Kadir, C. Gomes, J. Jasni, M. Osman

    Energization current is a fundamental consideration in designing of distribution substation earth grid. Arbitrary choice of energization current in earth grid design process may lead to technical and economic implications resulting in underestimated or overestimated designs. In this paper, a distribution substation earth grid was designed using SESCAD and executed in MALT module of CDEGS. The energization current was varied by 100, 75, 50 and 25% of the short circuit current available at the secondary terminals of the upstream transformer to determine the impact on safety criteria of the earth grid. Results indicated that, the EPR for 100% fault current was higher, whereas the step and touch voltages were lower. Also, compared to the other cases of short circuit currents, there was no difference in step and touch voltages when the energization currents were varied at 75, 50 and 25%.