Sajal De
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sajal De has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Nalok Banerjee
National Institute for Research in Environmental Health, Kamla Nehru Hospital Building, Gandhi Medical College Campus, Bhopal, 462001, India
6 shared publicationsDibakar Sahu
Department of Pulmonary, Critical Care, and Sleep Medicine, All India Institute of Medical Sciences, Raipur, Raipur, IND
4 shared publicationsDharmendra Dharwey
Department of Pulmonary Medicine, National Institute for Research in Environmental Health, Bhopal, Madhya Pradesh, India
3 shared publicationsGagan Deep Singh Kushwah
Department of Pulmonary Medicine, National Institute for Research in Environmental Health, Bhopal, Madhya Pradesh, India
3 shared publicationsSarmishtha De
Deartment of ENT, People's Medical College, Bhopal, India
3 shared publicationsYogesh Sabde
National Institute for Research in Environmental Health, Kamla Nehru Hospital Building, Gandhi Medical College Campus, Bhopal, 462001, India
2 shared publications
Latest Publications
- Open Access
- 15 May 2026
- Published by Open Exploration Publishing in Exploration of asthma & allergy
- Vol. 4
Aeroallergen sensitization patterns and their impact on lung function in adult asthma from a tertiary care centre in Chhattisgarh, India
Aim: This study aimed to assess the prevalence and patterns of aeroallergen sensitisation in steroid-naïve, newly diagnosed adult patients with bronchial asthma using skin prick test (SPT), and to examine its association with lung function parameters measured by oscillometry and spirometry. Methods: Consecutive adult patients with bronchial asthma who were naïve to systemic and inhaled corticosteroids were recruited. Following a detailed clinical history and blood investigations, lung function was assessed using oscillometry and spirometry. SPT was performed using a panel of 13 aeroallergens in accordance with established guidelines. Based on SPT results, patients were stratified into two groups: atopic asthma (sensitisation to ≥ 1 allergen) and non-atopic asthma (no sensitisation). Demographic characteristics, blood parameters, and lung function parameters were compared between the two groups. Results: Of 257 patients screened, 205 were enrolled (59% men; mean age 36.9 years). Allergic rhinitis was present in 58% of patients, and 69.8% had atopic asthma (95% CI 62.9–75.6). Sensitisation was most common to house dust mites (47.8%), followed by cockroach (37.6%) and weed pollen (29.8%). Atopy was more prevalent in men than in women and was associated with higher serum total IgE levels. Peripheral blood eosinophil counts, oscillometric parameters, severity of airflow obstruction, and bronchodilator responses did not differ significantly between atopic and non-atopic patients. Conclusions: The majority of asthma patients exhibited sensitisation to one or more aeroallergens. Despite differences in immunopathogenesis, no significant differences in oscillometric parameters were observed between atopic and non-atopic asthma, suggesting that atopic status has a limited influence on the severity of small airway dysfunction.
- 15 May 2026
- Published by Open Exploration Publishing in Exploration of asthma & allergy
- Vol. 4
Open AccessAeroallergen sensitization patterns and their impact on lung function in adult asthma from a tertiary care centre in Chhattisgarh, India
Aim: This study aimed to assess the prevalence and patterns of aeroallergen sensitisation in steroid-naïve, newly diagnosed adult patients with bronchial asthma using skin prick test (SPT), and to examine its association with lung function parameters measured by oscillometry and spirometry. Methods: Consecutive adult patients with bronchial asthma who were naïve to systemic and inhaled corticosteroids were recruited. Following a detailed clinical history and blood investigations, lung function was assessed using oscillometry and spirometry. SPT was performed using a panel of 13 aeroallergens in accordance with established guidelines. Based on SPT results, patients were stratified into two groups: atopic asthma (sensitisation to ≥ 1 allergen) and non-atopic asthma (no sensitisation). Demographic characteristics, blood parameters, and lung function parameters were compared between the two groups. Results: Of 257 patients screened, 205 were enrolled (59% men; mean age 36.9 years). Allergic rhinitis was present in 58% of patients, and 69.8% had atopic asthma (95% CI 62.9–75.6). Sensitisation was most common to house dust mites (47.8%), followed by cockroach (37.6%) and weed pollen (29.8%). Atopy was more prevalent in men than in women and was associated with higher serum total IgE levels. Peripheral blood eosinophil counts, oscillometric parameters, severity of airflow obstruction, and bronchodilator responses did not differ significantly between atopic and non-atopic patients. Conclusions: The majority of asthma patients exhibited sensitisation to one or more aeroallergens. Despite differences in immunopathogenesis, no significant differences in oscillometric parameters were observed between atopic and non-atopic asthma, suggesting that atopic status has a limited influence on the severity of small airway dysfunction.
- 24 April 2026
- Published by SAGE Publications in Respiratory Care
- Vol. 71 (9) , 1021-1023
Effect of Breathing Variability on Respiratory Impedance Measured by Oscillometry
- 24 April 2026
- Published by SAGE Publications in Respiratory Care
- Vol. 71 (9) , 1021-1023
Effect of Breathing Variability on Respiratory Impedance Measured by Oscillometry
- Open Access
- 24 March 2026
- Published by Elsevier in Pulmonary Function Diagnostics
- Vol. 2
Role of capnovolumetry in diagnosing lung function impairment
- 24 March 2026
- Published by Elsevier in Pulmonary Function Diagnostics
- Vol. 2
Open AccessRole of capnovolumetry in diagnosing lung function impairment
- 4 March 2026
- Published by Elsevier in Respiratory Medicine
- Vol. 254, 108752
Respiratory reactance index across severities of airflow obstruction in COPD and asthma
- 4 March 2026
- Published by Elsevier in Respiratory Medicine
- Vol. 254, 108752
Respiratory reactance index across severities of airflow obstruction in COPD and asthma
- Open Access
- 15 January 2026
- Published by Elsevier in Pulmonary Function Diagnostics
- Vol. 1 (1)
Agreement of respiratory impedance measurements between two commercial forced oscillation technique devices: A randomized crossover study
- 15 January 2026
- Published by Elsevier in Pulmonary Function Diagnostics
- Vol. 1 (1)
Open AccessAgreement of respiratory impedance measurements between two commercial forced oscillation technique devices: A randomized crossover study
- Open Access
- 1 January 2026
- Published by The Korean Academy of Tuberculosis and Respiratory Diseases in Tuberculosis and Respiratory Diseases
- Vol. 89 (1) , 94-101
Effects of Forceful Breathing Maneuvers of Spirometry on Respiratory Impedance Measured by Oscillometry
Background: Deep inspiratory maneuvers can modify airway diameter, leading to shortterm fluctuations in respiratory impedance (Zrs). However, the impact of the forceful breathing maneuvers used in spirometry on Zrs has not been systematically investigated. This study was designed to assess and compare the effects of spirometry maneuvers on Zrs, as measured by oscillometry, in adult patients with obstructive airway diseases (group I) versus those presenting with respiratory symptoms but without airflow obstruction on spirometry (group II).Methods: All participants underwent oscillometry assessments both before and immediately following spirometry. Paired t-tests and unpaired t-tests were conducted to compare differences within and between groups, respectively. Bland-Altman plots were utilized to display the percentage change in Zrs parameters against the mean, along with the limits of agreement (LoA).Results: In this cross-sectional study, 166 patients were enrolled (53% male), with a mean age of 40.4 years. Group I accounted for 62% of cases, while group II composed 38%. Patients in group I demonstrated greater impairment in both spirometry and Zrs parameters. Nearly all patients experienced changes in Zrs after spirometry compared to pre-spirometry values, regardless of group assignment. Except for R5 in group I, statistically significant paired differences in Zrs parameters were not observed between pre- and post-spirometry in either group. The cohort demonstrated mean biases between pre- and post-spirometry as follows: R5 4.6% (LoA: –44.8%, 54%); X5 5.8% (LoA: –69.5%, 81.2%); AX 4.3% (LoA: –93.9%,102.6%); and Fres 0.5% (LoA: –30.8%, 31.8%). The broad and random LoA reflect marked inter-individual variability.Conclusion: Spirometry maneuvers cause fluctuations in Zrs parameters, especially in R5. Oscillometry performed after spirometry may cause clinically meaningful changes in Zrs parameters.
- 1 January 2026
- Published by The Korean Academy of Tuberculosis and Respiratory Diseases in Tuberculosis and Respiratory Diseases
- Vol. 89 (1) , 94-101
Open AccessEffects of Forceful Breathing Maneuvers of Spirometry on Respiratory Impedance Measured by Oscillometry
Background: Deep inspiratory maneuvers can modify airway diameter, leading to shortterm fluctuations in respiratory impedance (Zrs). However, the impact of the forceful breathing maneuvers used in spirometry on Zrs has not been systematically investigated. This study was designed to assess and compare the effects of spirometry maneuvers on Zrs, as measured by oscillometry, in adult patients with obstructive airway diseases (group I) versus those presenting with respiratory symptoms but without airflow obstruction on spirometry (group II).Methods: All participants underwent oscillometry assessments both before and immediately following spirometry. Paired t-tests and unpaired t-tests were conducted to compare differences within and between groups, respectively. Bland-Altman plots were utilized to display the percentage change in Zrs parameters against the mean, along with the limits of agreement (LoA).Results: In this cross-sectional study, 166 patients were enrolled (53% male), with a mean age of 40.4 years. Group I accounted for 62% of cases, while group II composed 38%. Patients in group I demonstrated greater impairment in both spirometry and Zrs parameters. Nearly all patients experienced changes in Zrs after spirometry compared to pre-spirometry values, regardless of group assignment. Except for R5 in group I, statistically significant paired differences in Zrs parameters were not observed between pre- and post-spirometry in either group. The cohort demonstrated mean biases between pre- and post-spirometry as follows: R5 4.6% (LoA: –44.8%, 54%); X5 5.8% (LoA: –69.5%, 81.2%); AX 4.3% (LoA: –93.9%,102.6%); and Fres 0.5% (LoA: –30.8%, 31.8%). The broad and random LoA reflect marked inter-individual variability.Conclusion: Spirometry maneuvers cause fluctuations in Zrs parameters, especially in R5. Oscillometry performed after spirometry may cause clinically meaningful changes in Zrs parameters.
- 29 November 2025
- Published by Elsevier in Respiratory Medicine
- Vol. 250, 108551
Device-dependent variability in measurements of respiratory impedance: A call for harmonization of lung oscillometry
- 29 November 2025
- Published by Elsevier in Respiratory Medicine
- Vol. 250, 108551
Device-dependent variability in measurements of respiratory impedance: A call for harmonization of lung oscillometry
- 5 October 2025
- Published by Elsevier in Respiratory Medicine
- Vol. 248, 108399
Oscillometry-derived ratios for assessing small airway dysfunction: Emerging indices on the horizon
- 5 October 2025
- Published by Elsevier in Respiratory Medicine
- Vol. 248, 108399
Oscillometry-derived ratios for assessing small airway dysfunction: Emerging indices on the horizon
- Open Access
- 10 July 2025
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 25 (1) , 1-11
Comparison of oscillometry with lung function parameters between patients with stable bronchial asthma with airflow obstruction and chronic obstructive pulmonary disease
Lung oscillometry is an emerging investigation for assessing patients with obstructive airway disease. Comparison of oscillometry parameters with bronchodilator responsiveness (BDR) between patients with bronchial asthma and chronic obstructive pulmonary disease (COPD) with comparable severity of airflow obstruction has not been previously investigated. This study aimed to compare oscillometry parameters and bronchodilator responsiveness with other lung function parameters between stable bronchial asthma patients with airflow obstruction and COPD patients with a similar severity of airflow obstruction. We retrospectively reviewed the data of 467 consecutive adults with clinical diagnoses of bronchial asthma (n = 187) and COPD (n = 280). Oscillometry, spirometry, and body plethysmography were performed before and after inhalation of 400 µg of salbutamol. The patients were stratified based on the severity of airflow obstruction on spirometry. The z-scores of oscillometric parameters were used for comparison. The average age of the study population was 54.9 years, and 76.4% of the participants were male. Patients with COPD were older, had a higher proportion of smokers, and poorer lung function. The oscillometry parameters showed progressive impairment with increasing severity of airflow obstruction, irrespective of the underlying disease. Patients with bronchial asthma, particularly those with moderate to severe airway obstruction, demonstrated significantly greater R5 and R19 than patients with COPD. The within- and whole-breath X5 of bronchial asthma patients were not different from those of COPD patients with similar severity of airflow obstruction. Expiratory flow limitation at tidal breaths (ΔX5 > 0.28 kPa/L/s) was observed in both bronchial asthma and COPD patients across all severities of airflow obstruction. The proportion of BDR on oscillometry was significantly lower than that on spirometry for both bronchial asthma (35.3% vs. 57.1%; p < 0.01) and COPD patients (19.3% vs. 47.1%; p = 0.02). BDR in spirometry and BDR in oscillometry showed fair agreement for bronchial asthma and a slight agreement for COPD patients. Except for respiratory resistance, oscillometry parameters did not differ significantly between patients with bronchial asthma and those with COPD of similar severity of airflow obstruction. COPD patients exhibited a lower BDR in both spirometry and oscillometry than those with bronchial asthma.
- 10 July 2025
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 25 (1) , 1-11
Open AccessComparison of oscillometry with lung function parameters between patients with stable bronchial asthma with airflow obstruction and chronic obstructive pulmonary disease
Lung oscillometry is an emerging investigation for assessing patients with obstructive airway disease. Comparison of oscillometry parameters with bronchodilator responsiveness (BDR) between patients with bronchial asthma and chronic obstructive pulmonary disease (COPD) with comparable severity of airflow obstruction has not been previously investigated. This study aimed to compare oscillometry parameters and bronchodilator responsiveness with other lung function parameters between stable bronchial asthma patients with airflow obstruction and COPD patients with a similar severity of airflow obstruction. We retrospectively reviewed the data of 467 consecutive adults with clinical diagnoses of bronchial asthma (n = 187) and COPD (n = 280). Oscillometry, spirometry, and body plethysmography were performed before and after inhalation of 400 µg of salbutamol. The patients were stratified based on the severity of airflow obstruction on spirometry. The z-scores of oscillometric parameters were used for comparison. The average age of the study population was 54.9 years, and 76.4% of the participants were male. Patients with COPD were older, had a higher proportion of smokers, and poorer lung function. The oscillometry parameters showed progressive impairment with increasing severity of airflow obstruction, irrespective of the underlying disease. Patients with bronchial asthma, particularly those with moderate to severe airway obstruction, demonstrated significantly greater R5 and R19 than patients with COPD. The within- and whole-breath X5 of bronchial asthma patients were not different from those of COPD patients with similar severity of airflow obstruction. Expiratory flow limitation at tidal breaths (ΔX5 > 0.28 kPa/L/s) was observed in both bronchial asthma and COPD patients across all severities of airflow obstruction. The proportion of BDR on oscillometry was significantly lower than that on spirometry for both bronchial asthma (35.3% vs. 57.1%; p < 0.01) and COPD patients (19.3% vs. 47.1%; p = 0.02). BDR in spirometry and BDR in oscillometry showed fair agreement for bronchial asthma and a slight agreement for COPD patients. Except for respiratory resistance, oscillometry parameters did not differ significantly between patients with bronchial asthma and those with COPD of similar severity of airflow obstruction. COPD patients exhibited a lower BDR in both spirometry and oscillometry than those with bronchial asthma.
- Open Access
Agreement on Respiratory Impedance Measured by Two Commercial Forced Oscillation Technique Devices: A Randomized Crossover Study
Background: The performance of forced oscillation technique (FOT) devices may vary due to differences in hardware and signal processing. Research question: Does the respiratory impedance (Zrs) measured by two commercial FOT devices agree? Study Design and Methods: The Zrs of 97 consecutive adults with respiratory symptoms were measured using TremoFlo ® C-100 and Resmon™ Pro FULL V3, employing a random allocation and crossover design. The parameters between the devices were compared using paired t-tests and Bland-Altman plots with 95% limits of agreement (LoA). Results: The average age of the study population was 42.3 years, with 46% were women. The resistance parameters (R5 and R19) of Resmon ™ were larger than those obtained with TremoFlo ® . However, R5-19 of Resmon ™ was significantly smaller than TremoFlo ® , with a paired difference of -0.20 cm H 2 O/L/s (95% CI: -0.35, -0.05; p = 0.01). The within- and whole-breath X5 of Resmon ™ were significantly less negative than those obtained with TremoFlo ® . The reactance area and resonant frequency of Resmon ™ were also significantly smaller than those obtained with TremoFlo ® . The bias for R5 (Bias: 0.29 cmH 2 O/L/s; LoA: - 2.69, 3.26) was broad and had random errors. The bias for X5 (bias: 0.8 cmH 2 O/L/s; 95% LoA: -1.25, 2.85) and Ax (Bias: -13.66 cmH 2 O/L/s; LoA: -45.46, 18.14) was also wide and exhibited systematic errors. Interpretations: Respiratory impedance measured by the two FOT devices differed significantly, particularly for the reactance parameters. Normative Zrs generated by a particular oscillometer should be avoided when interpreting reports obtained from another device.
Open AccessAgreement on Respiratory Impedance Measured by Two Commercial Forced Oscillation Technique Devices: A Randomized Crossover Study
Background: The performance of forced oscillation technique (FOT) devices may vary due to differences in hardware and signal processing. Research question: Does the respiratory impedance (Zrs) measured by two commercial FOT devices agree? Study Design and Methods: The Zrs of 97 consecutive adults with respiratory symptoms were measured using TremoFlo ® C-100 and Resmon™ Pro FULL V3, employing a random allocation and crossover design. The parameters between the devices were compared using paired t-tests and Bland-Altman plots with 95% limits of agreement (LoA). Results: The average age of the study population was 42.3 years, with 46% were women. The resistance parameters (R5 and R19) of Resmon ™ were larger than those obtained with TremoFlo ® . However, R5-19 of Resmon ™ was significantly smaller than TremoFlo ® , with a paired difference of -0.20 cm H 2 O/L/s (95% CI: -0.35, -0.05; p = 0.01). The within- and whole-breath X5 of Resmon ™ were significantly less negative than those obtained with TremoFlo ® . The reactance area and resonant frequency of Resmon ™ were also significantly smaller than those obtained with TremoFlo ® . The bias for R5 (Bias: 0.29 cmH 2 O/L/s; LoA: - 2.69, 3.26) was broad and had random errors. The bias for X5 (bias: 0.8 cmH 2 O/L/s; 95% LoA: -1.25, 2.85) and Ax (Bias: -13.66 cmH 2 O/L/s; LoA: -45.46, 18.14) was also wide and exhibited systematic errors. Interpretations: Respiratory impedance measured by the two FOT devices differed significantly, particularly for the reactance parameters. Normative Zrs generated by a particular oscillometer should be avoided when interpreting reports obtained from another device.