Marc Doumit
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Marc Doumit has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Scott Pardoel
4 shared publicationsAlexander Helal
Department of Mechanical Engineering, University of Ottawa, Ontario, Canada
3 shared publications- Mohammed Abboodi
Department of Mechanical Engineering, University of Ottawa, Ottawa, Canada
2 shared publications - Robert Shaheen
Department of Mechanical Engineering, University of Ottawa, Ottawa, Ontario, Canada
2 shared publications - Thomas K. Uchida
Department of Mechanical Engineering, University of Ottawa, Ottawa, Canada
2 shared publications - Alexander Helal
Department of Mechanical Engineering, University of Ottawa, Ottawa, Ontario, Canada
1 shared publication
Latest Publications
- Open Access
- 13 May 2026
- Published by IOP Publishing in Progress in Biomedical Engineering
- Vol. 8 (2)
Soft Pneumatic Actuators for Wearable Systems: A Structural Classification and Integration-Oriented Evaluation
Soft pneumatic actuators promise gentle, body-safe assistance, yet many fail at the moment of integration: inflation alters geometry, increases profile, and stresses seams and ports. This topical review reframes actuator selection through a structure-first lens that links how an actuator is built to how it deforms and how it embeds in garments. Actuators are classified by structural architecture, deformation behaviour, and fabrication method, and evaluated against four integration criteria central to wearable systems: geometric compatibility, fabrication scalability, system integration readiness, and actuation simplicity. A staged selection pathway is proposed and presented as a literature-informed mapping table that links reported wearable application contexts to dominant integration priorities and a practical structural-class starting point. Planar sheet designs can preserve a thin, predictable pressurized envelope at modest pressures when seam paths, constraint layers, and attachment features are co-designed. Pouch and bladder actuators are thin at rest, simple to fabricate, and readily integrated with textiles, but commonly bulge under load without external constraint; envelope control and port or manifold routing frequently limit garment integration. Fiber-constrained actuators deliver high specific force but often require rigid end terminations and elevated pressures. Segmented elastomers provide rich kinematics through chamber layout while tending toward bulging and routing burden in multi-segment formats. Mechanical metamaterials realize geometry-programmed motion when hinge fidelity and pattern alignment are maintained; durability of compliant joints and consistent crease formation set current limits. The resulting synthesis identifies practical priorities for wearable use: preserve thin profiles under load, embed stitchable or bondable attachment features, document reproducible process windows, minimize dead volume, routing, and valve count with compact pneumatic architectures, and target low-pressure operation compatible with lightweight hardware. Framing integration in structural terms standardizes comparison across actuator classes, clarifies the narrow feasible design space for compact, body-conforming devices, and supports deliberate actuator choice for biomedical wearables.
- 13 May 2026
- Published by IOP Publishing in Progress in Biomedical Engineering
- Vol. 8 (2)
Open AccessSoft Pneumatic Actuators for Wearable Systems: A Structural Classification and Integration-Oriented Evaluation
Soft pneumatic actuators promise gentle, body-safe assistance, yet many fail at the moment of integration: inflation alters geometry, increases profile, and stresses seams and ports. This topical review reframes actuator selection through a structure-first lens that links how an actuator is built to how it deforms and how it embeds in garments. Actuators are classified by structural architecture, deformation behaviour, and fabrication method, and evaluated against four integration criteria central to wearable systems: geometric compatibility, fabrication scalability, system integration readiness, and actuation simplicity. A staged selection pathway is proposed and presented as a literature-informed mapping table that links reported wearable application contexts to dominant integration priorities and a practical structural-class starting point. Planar sheet designs can preserve a thin, predictable pressurized envelope at modest pressures when seam paths, constraint layers, and attachment features are co-designed. Pouch and bladder actuators are thin at rest, simple to fabricate, and readily integrated with textiles, but commonly bulge under load without external constraint; envelope control and port or manifold routing frequently limit garment integration. Fiber-constrained actuators deliver high specific force but often require rigid end terminations and elevated pressures. Segmented elastomers provide rich kinematics through chamber layout while tending toward bulging and routing burden in multi-segment formats. Mechanical metamaterials realize geometry-programmed motion when hinge fidelity and pattern alignment are maintained; durability of compliant joints and consistent crease formation set current limits. The resulting synthesis identifies practical priorities for wearable use: preserve thin profiles under load, embed stitchable or bondable attachment features, document reproducible process windows, minimize dead volume, routing, and valve count with compact pneumatic architectures, and target low-pressure operation compatible with lightweight hardware. Framing integration in structural terms standardizes comparison across actuator classes, clarifies the narrow feasible design space for compact, body-conforming devices, and supports deliberate actuator choice for biomedical wearables.
- Open Access
- 14 October 2025
- Published by MDPI AG in Electronics
- Vol. 14 (20) , 4020
Twisting Soft Sleeve Actuator: Design and Experimental Evaluation
Soft wearable actuators must align with anatomical joints, conform to limb geometry, and operate at low pneumatic pressures. Yet most twisting mechanisms rely on bulky attachment interfaces and relatively high actuation pressures, limiting practicality in assistive applications. This study introduces the first Twisting Soft Sleeve Actuator (TSSA), a self-contained, wearable actuator that produces controlled bidirectional torsion. The design integrates helically folded bellows with internal stabilization layers to suppress radial expansion and enhance torque transmission. The TSSA is fabricated from thermoplastic polyurethane using a Bowden-type fused filament fabrication (FFF) process optimized for airtightness and flexibility. Performance was characterized using a modular test platform that measured angular displacement and output force under positive pressure (up to 75 kPa) and vacuum (down to −85 kPa). A parametric study evaluated the effects of fold width, fold angle, wall thickness, and twist angle. Results demonstrate bidirectional, self-restoring torsion with clockwise rotation of approximately 30 degrees and a peak output force of about 40 N at 75 kPa, while reverse torsional motion occurred under vacuum actuation. The TSSA enables anatomically compatible, low-pressure torsion, supporting scalable, multi-degree-of-freedom sleeve systems for wearable robotics and rehabilitation.
- 14 October 2025
- Published by MDPI AG in Electronics
- Vol. 14 (20) , 4020
Open AccessTwisting Soft Sleeve Actuator: Design and Experimental Evaluation
Soft wearable actuators must align with anatomical joints, conform to limb geometry, and operate at low pneumatic pressures. Yet most twisting mechanisms rely on bulky attachment interfaces and relatively high actuation pressures, limiting practicality in assistive applications. This study introduces the first Twisting Soft Sleeve Actuator (TSSA), a self-contained, wearable actuator that produces controlled bidirectional torsion. The design integrates helically folded bellows with internal stabilization layers to suppress radial expansion and enhance torque transmission. The TSSA is fabricated from thermoplastic polyurethane using a Bowden-type fused filament fabrication (FFF) process optimized for airtightness and flexibility. Performance was characterized using a modular test platform that measured angular displacement and output force under positive pressure (up to 75 kPa) and vacuum (down to −85 kPa). A parametric study evaluated the effects of fold width, fold angle, wall thickness, and twist angle. Results demonstrate bidirectional, self-restoring torsion with clockwise rotation of approximately 30 degrees and a peak output force of about 40 N at 75 kPa, while reverse torsional motion occurred under vacuum actuation. The TSSA enables anatomically compatible, low-pressure torsion, supporting scalable, multi-degree-of-freedom sleeve systems for wearable robotics and rehabilitation.
- Open Access
- 27 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 40044-40053
Simulation of Hip Abduction-Adduction Exoskeletons for Assisting Frontal-Plane Stability in Elderly Individuals
Frontal-plane instability is positively correlated with higher incidence of severe injuries in elderly individuals. The effect of hip abduction–adduction assistance on stability in elderly individuals is not fully understood. This study investigates how the magnitude, timing, and location of hip abduction–adduction assistance affects the margin of stability. Methods: The OpenSim biomechanics software was used to generate simulations of eighteen elderly individuals while they stood with both feet on the floor and a lateral perturbation force of magnitude 5%, 10%, or 15% of bodyweight was applied to the pelvis. Contralateral, ipsilateral, or bilateral hip abduction–adduction assistance was applied following the perturbation. The change in margin of stability was used to predict the effectiveness of each assistance strategy and for comparison across subjects. Results: All assistance strategies improved the margin of stability; the greatest mean improvement was provided by the contralateral assistance strategy. For the 5%, 10%, and 15% bodyweight perturbations, contralateral assistance of 0.75 N·m/kg improved margin of stability by 11.9 ± 1.41 mm, 11.9 ± 1.39 mm, and 12.0 ± 1.39 mm, respectively. Conclusion: The margin of stability can be improved by applying hip abduction-adduction assistance to the contralateral hip with fast actuation strategies. Significance: The results of this study can be used by exoskeleton designers to improve the stability of elderly individuals by adopting a hip abduction-adduction assistance strategy.
- 27 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 40044-40053
Open AccessSimulation of Hip Abduction-Adduction Exoskeletons for Assisting Frontal-Plane Stability in Elderly Individuals
Frontal-plane instability is positively correlated with higher incidence of severe injuries in elderly individuals. The effect of hip abduction–adduction assistance on stability in elderly individuals is not fully understood. This study investigates how the magnitude, timing, and location of hip abduction–adduction assistance affects the margin of stability. Methods: The OpenSim biomechanics software was used to generate simulations of eighteen elderly individuals while they stood with both feet on the floor and a lateral perturbation force of magnitude 5%, 10%, or 15% of bodyweight was applied to the pelvis. Contralateral, ipsilateral, or bilateral hip abduction–adduction assistance was applied following the perturbation. The change in margin of stability was used to predict the effectiveness of each assistance strategy and for comparison across subjects. Results: All assistance strategies improved the margin of stability; the greatest mean improvement was provided by the contralateral assistance strategy. For the 5%, 10%, and 15% bodyweight perturbations, contralateral assistance of 0.75 N·m/kg improved margin of stability by 11.9 ± 1.41 mm, 11.9 ± 1.39 mm, and 12.0 ± 1.39 mm, respectively. Conclusion: The margin of stability can be improved by applying hip abduction-adduction assistance to the contralateral hip with fast actuation strategies. Significance: The results of this study can be used by exoskeleton designers to improve the stability of elderly individuals by adopting a hip abduction-adduction assistance strategy.
- Open Access
- 13 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 112440-112449
Design and Characterization of Twisted and Coiled Polymers and Their Applications as Soft Actuators
This study is an experimental investigation of twisted and coiled polymer actuators, focusing on characterization of the effects of design and operating parameters on the actuator performance. Using nylon-6 monofilaments, a custom fabrication and testing setup was designed to enable control of the operating conditions, precursor fiber diameter, actuator spring index, motor speed, training conditions, coil bias angle, pre-stretch of the precursor fiber, and pre-stretch of the actuator. Isotonic, isometric, and eccentric contraction tests were performed to evaluate each parameter’s effects on actuator stroke, force, and range in variable stiffness. Results demonstrate that optimal actuator performance is influenced by the operating conditions, selection of precursor fiber diameter, spring index, coil bias angle, training conditions, and the magnitude of pre-stretch in the precursor fiber and fully coiled actuator. This comprehensive experimental evaluation aims to assist in the optimization of twisted and coiled polymer actuators tailored to specific stroke, force, and variable stiffness performance requirements.
- 13 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 112440-112449
Open AccessDesign and Characterization of Twisted and Coiled Polymers and Their Applications as Soft Actuators
This study is an experimental investigation of twisted and coiled polymer actuators, focusing on characterization of the effects of design and operating parameters on the actuator performance. Using nylon-6 monofilaments, a custom fabrication and testing setup was designed to enable control of the operating conditions, precursor fiber diameter, actuator spring index, motor speed, training conditions, coil bias angle, pre-stretch of the precursor fiber, and pre-stretch of the actuator. Isotonic, isometric, and eccentric contraction tests were performed to evaluate each parameter’s effects on actuator stroke, force, and range in variable stiffness. Results demonstrate that optimal actuator performance is influenced by the operating conditions, selection of precursor fiber diameter, spring index, coil bias angle, training conditions, and the magnitude of pre-stretch in the precursor fiber and fully coiled actuator. This comprehensive experimental evaluation aims to assist in the optimization of twisted and coiled polymer actuators tailored to specific stroke, force, and variable stiffness performance requirements.
- Open Access
- 12 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 39995-40010
Development and Testing of Novel Soft Sleeve Actuators
The field of soft actuators and robotics has garnered considerable attention in recent years, driven by their distinct properties to adapt to diverse environments and enable secure and engaging interactions with humans. While current literature highlights a significant body of work on various soft actuators, it is noteworthy that the concept of soft sleeve actuation remains unexplored, as it has not yet been proposed. The concept of soft sleeve actuation represents a significant leap forward in the field of robotics, heralding tremendous potential for diverse applications, particularly for wearable robotics. This paper introduces a novel soft sleeve actuation mechanism, encompassing the development of two actuators capable of generating linear and bending motion. These actuators are lightweight and capable of generating considerable force and motion. Using Fused Deposition Modeling technology, a comprehensive fabrication framework was adopted to overcome manufacturing variability and fabricate high-quality airtight actuators. The mechanical performance of the proposed soft sleeve actuators (SLA) was investigated through a custom-built experimental testing setup. The impact of geometric parameters and material stiffness on the behavior of the developed actuators is studied and discussed.
- 12 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 39995-40010
Open AccessDevelopment and Testing of Novel Soft Sleeve Actuators
The field of soft actuators and robotics has garnered considerable attention in recent years, driven by their distinct properties to adapt to diverse environments and enable secure and engaging interactions with humans. While current literature highlights a significant body of work on various soft actuators, it is noteworthy that the concept of soft sleeve actuation remains unexplored, as it has not yet been proposed. The concept of soft sleeve actuation represents a significant leap forward in the field of robotics, heralding tremendous potential for diverse applications, particularly for wearable robotics. This paper introduces a novel soft sleeve actuation mechanism, encompassing the development of two actuators capable of generating linear and bending motion. These actuators are lightweight and capable of generating considerable force and motion. Using Fused Deposition Modeling technology, a comprehensive fabrication framework was adopted to overcome manufacturing variability and fabricate high-quality airtight actuators. The mechanical performance of the proposed soft sleeve actuators (SLA) was investigated through a custom-built experimental testing setup. The impact of geometric parameters and material stiffness on the behavior of the developed actuators is studied and discussed.
- 24 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (9) , 2797-2805
Simulating Ideal Assistive Strategies to Reduce the Metabolic Cost of Walking in the Elderly
Objective: Development of walking assist exoskeletons is a growing area of study, offering a solution to restore, maintain, and enhance mobility. However, applying this technology to the elderly is challenging and there is currently no consensus as to the optimal strategy for assisting elderly gait. The gait patterns of elderly individuals often differ from those of the younger population, primarily in the ankle and hip joints. This study used musculoskeletal simulations to predict how ankle and hip actuators might affect the energy expended by elderly participants during gait. Methods: OpenSim was used to generate simulations of 10 elderly participants walking at self-selected slow, comfortable, and fast speeds. Ideal flexion/extension assistive actuators were added bilaterally to the ankle or hip joints of the models to predict the maximum metabolic power that could be saved by exoskeletons that apply torques at these joints. Results: Compared to the unassisted scenario, the use of ideal hip actuators resulted in 21±5%, 26±5%, and 30±6% reductions in average metabolic power consumption at slow, comfortable, and fast walking speeds, respectively; use of ideal ankle actuators resulted in 12±3%, 14±2%, and 16±1% metabolic savings, respectively. Conclusion: The simulations suggest that providing hip assistance to elderly individuals during walking can result in significantly greater metabolic savings than ankle assistance, assuming kinematics and total joint moments do not change substantially with assistance. Significance: The achieved research results and analysis provide exoskeleton developers guidance on optimally designing walking assist exoskeletons, thus promoting consensus toward the optimal strategy for assisting elderly individuals.
- 24 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (9) , 2797-2805
Simulating Ideal Assistive Strategies to Reduce the Metabolic Cost of Walking in the Elderly
Objective: Development of walking assist exoskeletons is a growing area of study, offering a solution to restore, maintain, and enhance mobility. However, applying this technology to the elderly is challenging and there is currently no consensus as to the optimal strategy for assisting elderly gait. The gait patterns of elderly individuals often differ from those of the younger population, primarily in the ankle and hip joints. This study used musculoskeletal simulations to predict how ankle and hip actuators might affect the energy expended by elderly participants during gait. Methods: OpenSim was used to generate simulations of 10 elderly participants walking at self-selected slow, comfortable, and fast speeds. Ideal flexion/extension assistive actuators were added bilaterally to the ankle or hip joints of the models to predict the maximum metabolic power that could be saved by exoskeletons that apply torques at these joints. Results: Compared to the unassisted scenario, the use of ideal hip actuators resulted in 21±5%, 26±5%, and 30±6% reductions in average metabolic power consumption at slow, comfortable, and fast walking speeds, respectively; use of ideal ankle actuators resulted in 12±3%, 14±2%, and 16±1% metabolic savings, respectively. Conclusion: The simulations suggest that providing hip assistance to elderly individuals during walking can result in significantly greater metabolic savings than ankle assistance, assuming kinematics and total joint moments do not change substantially with assistance. Significance: The achieved research results and analysis provide exoskeleton developers guidance on optimally designing walking assist exoskeletons, thus promoting consensus toward the optimal strategy for assisting elderly individuals.
- 6 May 2020
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 80 (1) , 33-43
Study of human-machine physical interface for wearable mobility assist devices
A decrease in mobility, related to illness, trauma or ageing, negatively affects the quality of life of the rapidly growing elderly population. A promising solution to maintain this standard of living is powered wearable mobility assist devices. Although they have achieved technological breakthroughs in the last decade, their overall success is still hindered by their induced physical discomfort, which limits their effective and prolonged usage. The aim of this study is to achieve a comprehensive characterization of human-machine physical interface to further advance the performance of wearable mobility assist devices, specifically for the knee joint. This led the research group to design, fabricate, and instrument a low-cost modular knee orthosis testing apparatus with extension moment assist that allows multiple physical interface adjustment parameters. This device was conceived with the objective to conduct human testing while introducing design variables and operating parameters to evaluate device's performance. Using a force mapping apparatus and a motion capture system, the kinetic and the kinematic behaviour of the developed orthosis' physical interfaces were acquired. The results demonstrated varied impact on performance when introducing key design variables namely interface position, interface geometry, interface compliancy, interface hard-shell position, interface degree of freedom, and knee extension moment. This study provides an in-depth understanding of distinct user-device interface mechanisms and permitted an evaluation of optimum orthosis parameters to help further advance the state of wearable mobility assist devices.
- 6 May 2020
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 80 (1) , 33-43
Study of human-machine physical interface for wearable mobility assist devices
A decrease in mobility, related to illness, trauma or ageing, negatively affects the quality of life of the rapidly growing elderly population. A promising solution to maintain this standard of living is powered wearable mobility assist devices. Although they have achieved technological breakthroughs in the last decade, their overall success is still hindered by their induced physical discomfort, which limits their effective and prolonged usage. The aim of this study is to achieve a comprehensive characterization of human-machine physical interface to further advance the performance of wearable mobility assist devices, specifically for the knee joint. This led the research group to design, fabricate, and instrument a low-cost modular knee orthosis testing apparatus with extension moment assist that allows multiple physical interface adjustment parameters. This device was conceived with the objective to conduct human testing while introducing design variables and operating parameters to evaluate device's performance. Using a force mapping apparatus and a motion capture system, the kinetic and the kinematic behaviour of the developed orthosis' physical interfaces were acquired. The results demonstrated varied impact on performance when introducing key design variables namely interface position, interface geometry, interface compliancy, interface hard-shell position, interface degree of freedom, and knee extension moment. This study provides an in-depth understanding of distinct user-device interface mechanisms and permitted an evaluation of optimum orthosis parameters to help further advance the state of wearable mobility assist devices.
- 1 October 2019
- Published by Elsevier in Biocybernetics and Biomedical Engineering
- Vol. 39 (4) , 992-1004
Development and testing of a passive Walking Assist Exoskeleton
- 1 October 2019
- Published by Elsevier in Biocybernetics and Biomedical Engineering
- Vol. 39 (4) , 992-1004
Development and testing of a passive Walking Assist Exoskeleton
- 1 July 2019
- Published by Elsevier in Biocybernetics and Biomedical Engineering
- Vol. 39 (3) , 902-913
Development and testing of a passive ankle exoskeleton
- 1 July 2019
- Published by Elsevier in Biocybernetics and Biomedical Engineering
- Vol. 39 (3) , 902-913
Development and testing of a passive ankle exoskeleton
- 22 August 2018
- Published by Taylor & Francis in Disability and Rehabilitation: Assistive Technology
- Vol. 15 (1) , 1-13
Development of an unpowered ankle exoskeleton for walking assist
Aim: Assistive technologies traditionally rely on either powered actuation or passive structures to provide increased strength, support or the ability to perform specific functions. At one end of the spectrum are powered exoskeletons, which significantly increase a user’s strength, but require powerful actuators, complex control systems and heavy power sources. At the other end are orthoses, which are generally unpowered and light in weight, relying on the mechanical properties of passive mechanical elements. Ideally, assistive technologies should combine the benefits of both systems and enhance human motion while remaining lightweight and efficient. This paper presents the development of a lightweight unpowered ankle exoskeleton that relies on the spring-like properties of a Pneumatic Artificial Muscle, which is inflated and sealed. Methods: This flexible air-spring is used to harness gait energy and compliment the human ankle torque at push-off. To mechanically validate the proposed exoskeleton design, a prototype was fabricated and experimentally tested. Results: Unlike other existing devices, the proposed unpowered exoskeleton was able to store a significant amount of energy and release it all at once. The timing mechanism worked as intended and triggered the release of 115 N m of torque when the ankle reached a pre-determined angle. Conclusion: Overall, the device demonstrated the ability to provide significant contribution to the ankle torque, timed to release precisely at the push-off phase of the gait cycle.
- 22 August 2018
- Published by Taylor & Francis in Disability and Rehabilitation: Assistive Technology
- Vol. 15 (1) , 1-13
Development of an unpowered ankle exoskeleton for walking assist
Aim: Assistive technologies traditionally rely on either powered actuation or passive structures to provide increased strength, support or the ability to perform specific functions. At one end of the spectrum are powered exoskeletons, which significantly increase a user’s strength, but require powerful actuators, complex control systems and heavy power sources. At the other end are orthoses, which are generally unpowered and light in weight, relying on the mechanical properties of passive mechanical elements. Ideally, assistive technologies should combine the benefits of both systems and enhance human motion while remaining lightweight and efficient. This paper presents the development of a lightweight unpowered ankle exoskeleton that relies on the spring-like properties of a Pneumatic Artificial Muscle, which is inflated and sealed. Methods: This flexible air-spring is used to harness gait energy and compliment the human ankle torque at push-off. To mechanically validate the proposed exoskeleton design, a prototype was fabricated and experimentally tested. Results: Unlike other existing devices, the proposed unpowered exoskeleton was able to store a significant amount of energy and release it all at once. The timing mechanism worked as intended and triggered the release of 115 N m of torque when the ankle reached a pre-determined angle. Conclusion: Overall, the device demonstrated the ability to provide significant contribution to the ankle torque, timed to release precisely at the push-off phase of the gait cycle.