Nicholas Maling
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Nicholas Maling has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Alfons Schnitzler
Institute of Clinical Neuroscience and Medical Psychology, Medical Faculty, Heinrich Heine University Düsseldorf, Germany
1 shared publication - Ann-Kristin Helmers
Department of Neurosurgery, Christian-Albrechts-Universität zu Kiel, 24105 Kiel, Germany
1 shared publication Benjamin J. Rivera
Department of Communication Sciences and Disorders, University of South Florida, United States
1 shared publication- David D. Fuller
University of Florida
1 shared publication - David M. Baekey
Department of Physiological Sciences University of Florida, College of Veterinary Medicine Gainesville FL
1 shared publication - Elisa Janine Gonzalez-Rothi
Department of Physical Therapy, University of Florida, Gainesville, Florida, United States
1 shared publication
Latest Publications
- Open Access
- 8 January 2022
- Published by MDPI AG in Brain Sciences
- Vol. 12 (1) , 86
MaDoPO: Magnetic Detection of Positions and Orientations of Segmented Deep Brain Stimulation Electrodes: A Radiation-Free Method Based on Magnetoencephalography
Background: Current approaches to detect the positions and orientations of directional deep brain stimulation (DBS) electrodes rely on radiative imaging data. In this study, we aim to present an improved version of a radiation-free method for magnetic detection of the position and the orientation (MaDoPO) of directional electrodes based on a series of magnetoencephalography (MEG) measurements and a possible future solution for optimized results using emerging on-scalp MEG systems. Methods: A directional DBS system was positioned into a realistic head–torso phantom and placed in the MEG scanner. A total of 24 measurements of 180 s each were performed with different predefined electrode configurations. Finite element modeling and model fitting were used to determine the position and orientation of the electrode in the phantom. Related measurements were fitted simultaneously, constraining solutions to the a priori known geometry of the electrode. Results were compared with the results of the high-quality CT imaging of the phantom. Results: The accuracy in electrode localization and orientation detection depended on the number of combined measurements. The localization error was minimized to 2.02 mm by considering six measurements with different non-directional bipolar electrode configurations. Another six measurements with directional bipolar stimulations minimized the orientation error to 4°. These values are mainly limited due to the spatial resolution of the MEG. Moreover, accuracies were investigated as a function of measurement time, number of sensors, and measurement direction of the sensors in order to define an optimized MEG device for this application. Conclusion: Although MEG introduces inaccuracies in the detection of the position and orientation of the electrode, these can be accepted when evaluating the benefits of a radiation-free method. Inaccuracies can be further reduced by the use of on-scalp MEG sensor arrays, which may find their way into clinics in the foreseeable future.
- 8 January 2022
- Published by MDPI AG in Brain Sciences
- Vol. 12 (1) , 86
Open AccessMaDoPO: Magnetic Detection of Positions and Orientations of Segmented Deep Brain Stimulation Electrodes: A Radiation-Free Method Based on Magnetoencephalography
Background: Current approaches to detect the positions and orientations of directional deep brain stimulation (DBS) electrodes rely on radiative imaging data. In this study, we aim to present an improved version of a radiation-free method for magnetic detection of the position and the orientation (MaDoPO) of directional electrodes based on a series of magnetoencephalography (MEG) measurements and a possible future solution for optimized results using emerging on-scalp MEG systems. Methods: A directional DBS system was positioned into a realistic head–torso phantom and placed in the MEG scanner. A total of 24 measurements of 180 s each were performed with different predefined electrode configurations. Finite element modeling and model fitting were used to determine the position and orientation of the electrode in the phantom. Related measurements were fitted simultaneously, constraining solutions to the a priori known geometry of the electrode. Results were compared with the results of the high-quality CT imaging of the phantom. Results: The accuracy in electrode localization and orientation detection depended on the number of combined measurements. The localization error was minimized to 2.02 mm by considering six measurements with different non-directional bipolar electrode configurations. Another six measurements with directional bipolar stimulations minimized the orientation error to 4°. These values are mainly limited due to the spatial resolution of the MEG. Moreover, accuracies were investigated as a function of measurement time, number of sensors, and measurement direction of the sensors in order to define an optimized MEG device for this application. Conclusion: Although MEG introduces inaccuracies in the detection of the position and orientation of the electrode, these can be accepted when evaluating the benefits of a radiation-free method. Inaccuracies can be further reduced by the use of on-scalp MEG sensor arrays, which may find their way into clinics in the foreseeable future.
- 24 September 2012
- Published by Elsevier in Behavioural Brain Research
- Vol. 237, 157-163
Differential sensitivity of cranial and limb motor function to nigrostriatal dopamine depletion
- 24 September 2012
- Published by Elsevier in Behavioural Brain Research
- Vol. 237, 157-163
Differential sensitivity of cranial and limb motor function to nigrostriatal dopamine depletion
- Open Access
- 6 September 2012
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 7 (9) , e44215
Increased Thalamic Gamma Band Activity Correlates with Symptom Relief following Deep Brain Stimulation in Humans with Tourette’s Syndrome
Tourette syndrome (TS) is an idiopathic, childhood-onset neuropsychiatric disorder, which is marked by persistent multiple motor and phonic tics. The disorder is highly disruptive and in some cases completely debilitating. For those with severe, treatment-refractory TS, deep brain stimulation (DBS) has emerged as a possible option, although its mechanism of action is not fully understood. We performed a longitudinal study of the effects of DBS on TS symptomatology while concomitantly examining neurophysiological dynamics. We present the first report of the clinical correlation between the presence of gamma band activity and decreased tic severity. Local field potential recordings from five subjects implanted in the centromedian nucleus (CM) of the thalamus revealed a temporal correlation between the power of gamma band activity and the clinical metrics of symptomatology as measured by the Yale Global Tic Severity Scale and the Modified Rush Tic Rating Scale. Additional studies utilizing short-term stimulation also produced increases in gamma power. Our results suggest that modulation of gamma band activity in both long-term and short-term DBS of the CM is a key factor in mitigating the pathophysiology associated with TS.
- 6 September 2012
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 7 (9) , e44215
Open AccessIncreased Thalamic Gamma Band Activity Correlates with Symptom Relief following Deep Brain Stimulation in Humans with Tourette’s Syndrome
Tourette syndrome (TS) is an idiopathic, childhood-onset neuropsychiatric disorder, which is marked by persistent multiple motor and phonic tics. The disorder is highly disruptive and in some cases completely debilitating. For those with severe, treatment-refractory TS, deep brain stimulation (DBS) has emerged as a possible option, although its mechanism of action is not fully understood. We performed a longitudinal study of the effects of DBS on TS symptomatology while concomitantly examining neurophysiological dynamics. We present the first report of the clinical correlation between the presence of gamma band activity and decreased tic severity. Local field potential recordings from five subjects implanted in the centromedian nucleus (CM) of the thalamus revealed a temporal correlation between the power of gamma band activity and the clinical metrics of symptomatology as measured by the Yale Global Tic Severity Scale and the Modified Rush Tic Rating Scale. Additional studies utilizing short-term stimulation also produced increases in gamma power. Our results suggest that modulation of gamma band activity in both long-term and short-term DBS of the CM is a key factor in mitigating the pathophysiology associated with TS.
- Open Access
- 1 April 2012
- Published by Wiley in The FASEB Journal
- Vol. 26 (S1) , 1147.3
Cervical interneuron bursting during hypoxia in anesthetized rats
Cervical spinal laminae VII‐X contain interneurons that are synaptically coupled to phrenic motoneurons (PMNs). Neurophysiological studies suggest these cells are not necessary for transmission of inspiratory drive, but their role in modulating PMN output during respiratory stimulation or plasticity is unknown. In ongoing studies, we are exploring the role of cervical interneurons in hypoxia‐induced phrenic plasticity. Since spinal serotonin (5‐HT) can induce phrenic plasticity, we first examined whether pre‐phrenic cervical interneurons are innervated by 5‐HT. 5‐HT immunoreactivity was robust throughout cervical laminae VII‐X and in the immediate vicinity of pre‐phrenic interneurons identified with a transynaptic retrograde tracer (pseudorabies virus, delivered to the diaphragm). Cervical interneuron activity was recorded in anesthetized, paralyzed, vagotomized and ventilated adult rats. Initial results indicate that tonic and phasic bursting interneurons are distributed throughout the C3‐C5 intermediate gray matter. During respiratory stimulation with hypoxia a subset of the cervical interneurons showed an increase in burst frequency, and in some cases switched from tonic to phasic bursting. Cervical interneurons are anatomically positioned to modulate phrenic motor output, but their potential role in initiating and/or maintaining phrenic plasticity remains to be determined.
- 1 April 2012
- Published by Wiley in The FASEB Journal
- Vol. 26 (S1) , 1147.3
Open AccessCervical interneuron bursting during hypoxia in anesthetized rats
Cervical spinal laminae VII‐X contain interneurons that are synaptically coupled to phrenic motoneurons (PMNs). Neurophysiological studies suggest these cells are not necessary for transmission of inspiratory drive, but their role in modulating PMN output during respiratory stimulation or plasticity is unknown. In ongoing studies, we are exploring the role of cervical interneurons in hypoxia‐induced phrenic plasticity. Since spinal serotonin (5‐HT) can induce phrenic plasticity, we first examined whether pre‐phrenic cervical interneurons are innervated by 5‐HT. 5‐HT immunoreactivity was robust throughout cervical laminae VII‐X and in the immediate vicinity of pre‐phrenic interneurons identified with a transynaptic retrograde tracer (pseudorabies virus, delivered to the diaphragm). Cervical interneuron activity was recorded in anesthetized, paralyzed, vagotomized and ventilated adult rats. Initial results indicate that tonic and phasic bursting interneurons are distributed throughout the C3‐C5 intermediate gray matter. During respiratory stimulation with hypoxia a subset of the cervical interneurons showed an increase in burst frequency, and in some cases switched from tonic to phasic bursting. Cervical interneurons are anatomically positioned to modulate phrenic motor output, but their potential role in initiating and/or maintaining phrenic plasticity remains to be determined.