Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Meysam Saeedian has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Simultaneous Optimization of Virtual Synchronous Generators (VSG) Parameters in Islanded Microgrids Supplying Induction Motors

    by Bahram Pournazarian, Reza Sangrody, Meysam Saeedian, Matti Lehtonen, Edris Pouresmaeil

    The growing importance of Microgrid in future power systems highlights critical challenges like microgrid control and stability. An islanded microgrid including distributed generations (DG), energy storage systems (ESS), and different types of loads (static or dynamic) is prone to instability. The whole microgrid system must be analyzed and designed to operate within stable regions. This study models an inverter-interfaced microgrid which supplies different types of loads such as static loads and symmetrical induction machines (SIM) by virtual synchronous generators (VSG). Afterwards, a generalized small-signal stability analysis framework is proposed for an islanded microgrid. This model is applied for stability analysis of an arbitrary islanded microgrid including several VSGs, lines, static loads, and SIM loads. Subsequently, permissible intervals for VSG parameters are drawn according to the microgrid small-signal stability analysis. These permissible intervals are compared for static and SIM load. Finally, a novel optimization platform is introduced which utilizes the particle swarm optimization (PSO) algorithm to draw optimal values for virtual impedances (VI), virtual inertia (Jv), virtual damping (D), and current state-feedback factor (F). The proposed optimization platform enhances the microgrid stability, minimizes voltage drops on the buses, the reactive power mismatches, and the frequency Nadir, simultaneously.


  • Open Access

    Enhancing Microgrid Small-Signal Stability and Reactive Power Sharing Using ANFIS-Tuned Virtual Inductances

    by Bahram Pournazarian, Reza Sangrody, Meysam Saeedian, Oriol Gomis-Bellmunt, Edris Pouresmaeil

    Microgrid as the main building block for future smart grids is prone to instability originated from converter-based distributed generations (DG). Herein, we first analyze the small-signal stability of an inverter-interfaced microgrid. Then, a novel adaptive network fuzzy inference system (ANFIS)-based optimization method is introduced which aims at online tuning of virtual inductances (VI) in the islanded microgrids. The data for ANFIS training is drawn by particle swarm optimization (PSO) algorithm and the proposed objective function. A total of 140 load scenarios are considered to provide optimal VI in each load condition and generate optimal data for ANFIS training. This process yields minimizing reactive power mismatches and improves microgrid stability in different load levels. The simultaneous application of PSO algorithm and ANFIS training facilitates the objectives pursued by current study. Finally, the trained ANFIS networks are installed in the converter control. The adaptive performance of ANFIS controllers makes the converters responses independent from load change location and value. The effectiveness of the proposed control methodology is verified using simulations studies.


  • Open Access

    Provision of Synthetic Inertia Support for Converter-Dominated Weak Grids

    by Meysam Saeedian, Bahram Pournazarian, Shamsodin Taheri, Edris Pouresmaeil

    Insufficient inertia is the paramount challenge in power system transition toward $ 100\%$ converter-based generation. A promising solution to this issue is utilizing distributed virtual inertia (DVI) concept, i.e., releasing energy stored in the dc-link capacitors of power converters employed in the grid following a frequency disturbance. Nevertheless, this method has two drawbacks: $ 1$ ) the dc-link voltage is not reverted to its reference value after the power mismatch between generation and demand, and $ 2$ ) it yields instability of a local mode associated with the control system when the converter operates in weak grids. To overcome the aforesaid problems, the conventional DVI loop is modified so as not to affect the outer loop voltage regulator after transient. Moreover, an efficient compensator is presented in this article which eliminates the adverse impact of DVI technique on the converter stability in weak grid connections. The efficacy of proposed control scheme is depicted by simulations in MATLAB. The results illustrate that an improvement of $ 23\%$ is evident in the grid frequency rate of change following a frequency contingency collated with the case in which the DVI loop staying nullified.


  • Open Access

    Grid–Following DVI–Based Converter Operating in Weak Grids for Enhancing Frequency Stability

    by Meysam Saeedian, Reza Sangrody, Mahdi Shahparasti, Shamsodin Taheri, Edris Pouresmaeil

    Inertia requirement is the paramount challenge in future power systems with a significant share of renewable energy generators. A promising solution to this issue is applying Distributed Virtual Inertia (DVI) concept, i.e. releasing energy preserved in the DC–link capacitors of employed power converters in the grid following a frequency disturbance. Nonetheless, small–signal stability analyses affirm that a local mode associated with the control system is prone to become unstable when the grid–interactive converter augmented with the DVI operates in weak grids. To overcome this problem, an efficient compensator is proposed in this paper. This compensator introduces one degree–of–freedom to the direct–axis current controller in synchronous reference frame, which eliminates the adverse impact of DVI function on converter stability. Finally, the efficacy of the proposed control framework is depicted by simulations in MATLAB. The results illustrate that the grid frequency rate of change following a step–up load change is improved by 30% compared to the case in which the DVI loop is nullified.


  • Microgrid Stability Analysis Considering Current State-Feedback

    by Bahram Pournazarian, Meysam Saeedian, Matti Lehtonen, Shamsodin Taheri, Edris Pouresmaeil

    A converter-based microgrid including several distributed generations (DG) and energy storage systems (ESS) embodies a small power system consisting of several synchronous machines and loads. The stability issue and the coordination between generating units is an essential challenge, either in island or in grid-connected microgrids. The instability of individual DGs cause the microgrid instability as a whole. So, the individual unit stability and the microgrid stability both must be ensured simultaneously. The state feedback concept which is considered in control of converters has a substantial effect on the converter stability and microgrid stability, subsequently. This study will introduce a small-signal model for the microgrid including converter-based DGs and loads considering the previous studies in this field. A phase locked loop (PLL) is required for the control strategy. The effect of current state feedback is scrutinized and analyzed in this study as the main contribution. The effectiveness of the proposed control strategy to enhance the microgrid stability using chosen state feedback is examined through simulation studies. The simulation results ensure that the microgrid stability using the proposed control method and state-feedback is strengthened.


  • Performance Evaluation of Three-Phase Boost-Inverter for Grid-Connected PV System

    by Bahman Eskandari, Jorma Kyyra, Bahram Pournazarian, Meysam Saeedian, Edris Pouresmaeil

    In this paper, a new efficient topology of three-phase boost type converter is developed based on 100kHz switching frequency. The nonlinear equations are extracted based on the averaging method and a controller for grid-connected PV system is developed via a nonlinear modulation technique.

  • Enhancing Frequency Stability of Weak Grids with Modified Distributed Virtual Inertia Method

    by Meysam Saeedian, Bahram Pournazarian, Bahman Eskandari, Mahdi Shahparasti, Edris Pouresmaeil

    In small–scale power systems, distributed virtual inertia (DVI)–based converters can effectively participate in primary frequency regulation. In this method, the synthetic inertia provision is fulfilled by discharging the preserved energy of dc–side capacitors employed in grid–interactive converters. Nevertheless, the eigenvalue analyses provided by small–signal state–space model of the converter reveal that the DVI function induces instability to the converter operating in weak grid connection. To address this issue aimed at improving grid frequency stability during frequency events, a new compensator is presented in this work. The compensator is designed so as eliminates the negative effect of DVI regulator on system stability. The effectiveness of proposed approach is illustrated by the time–domain simulations in MATLAB. The results show that the frequency rate of change following a frequency perturbation is enhanced by 40.38% compared with the scenario in which the synthetic inertia functionality is nullified.


  • Open Access

    Emulating Rotational Inertia of Synchronous Machines by a New Control Technique in Grid-Interactive Converters

    by Meysam Saeedian, Bahram Pournazarian, S. Sajjad Seyedalipour, Bahman Eskandari, Edris Pouresmaeil

    Integration of renewable energy sources (RESs) into power systems is growing due to eco-friendly concerns and ever-increasing electricity demand. Voltage source converters (VSCs) are the main interface between RESs and power grids, which have neither rotational inertia nor damping characteristics. Lack of these metrics make the power grid sensitive to frequency disturbances and thereby under frequency, to load shedding activation or even large-scale collapse. In this regard, the contribution of this paper is to develop a new control technique for VSCs that can provide virtual inertia and damping properties with the DC-link capacitors inhered in the DC-side of grid-tied VSCs. The applied VSC is controlled in the current controlled model, with the capability of injecting extra active power with the aim of frequency support during perturbations. The dynamics assessment of the proposed platform is derived in detail. It is revealed that the control scheme performs in a stable region even under weak-grid conditions. Finally, simulations are conducted in MATLAB to depict the efficacy and feasibility of the proposed method. The results show that frequency deviation is mitigated under step up/down changes in the demand, and the rate of change of frequency is improved by 47.37% compared to the case in which the synthetic inertia loop is canceled out.


  • A Control Technique Based on Distributed Virtual Inertia for High Penetration of Renewable Energies Under Weak Grid Conditions

    by Meysam Saeedian, Bahman Eskandari, Shamsodin Taheri, Marko Hinkkanen, Edris Pouresmaeil

    Distributed virtual inertia is an approach of providing synthetic inertia in small-scale modern grids dominated by converter-based generators. In this method, the inertial response of synchronous machines is emulated by the energy stored in the dc-link capacitors of grid-tied converters. Nonetheless, it results in instability of the interfaced converter in weak grids. To overcome this problem and get the most benefit out of the acceptable dc-link capacitor voltage deviations, a new compensation technique is proposed in this article. The grid-interactive converter in the presented framework is controlled in the current control mode, compositing of two conventional inner and outer control loops, distributed virtual inertia controller, and a novel compensator. The detailed small-signal representation of the whole control scheme in state-space form is derived. Then, it is revealed that the coupling between d- and q-axis controllers introduced by the distributed virtual inertia gain and its differential operator gives rise to the system instability in weak grids, which can be eliminated through the ancillary compensator. The time-domain simulation model is built to confirm the efficacy of the proposed control technique. The results depict that the ancillary active power provided by the proposed approach during frequency disturbance is 14% of the converter power rating of 20 kW, which yields the improvement of frequency rate of change by 18.82%.