Lisle Snyder
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lisle Snyder has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Jody D. Potter
Department of Natural Resources and the Environment University of New Hampshire Durham NH USA
3 shared publications - William McDowell
Department of Natural Resources and the Environment University of New Hampshire Durham New Hampshire USA
3 shared publications - Lauren E. Koenig
Water Mission Area U.S. Geological Survey Reston VA USA
2 shared publications - Michelle Daley Shattuck
Department of Natural Resources and the Environment University of New Hampshire Durham NH USA
1 shared publication Shattuck
University of New Hampshire Departement of Natural Resources and the Environment Durham NH USA
1 shared publicationWilliam B. Bowden
Rubenstein School of Environment and Natural Resources University of Vermont Burlington Vermont USA
1 shared publication
Latest Publications
- Open Access
- 30 March 2018
- Published by American Geophysical Union (AGU) in Water Resources Research
- Vol. 54 (3) , 2466-2479
An Evaluation of Nitrate, fDOM, and Turbidity Sensors in New Hampshire Streams
A state‐of‐the‐art network of water quality sensors was established in 2012 to gather year‐round high temporal frequency hydrochemical data in streams and rivers throughout the state of New Hampshire. This spatially extensive network includes eight headwater stream and two main stem river monitoring sites, spanning a variety of stream orders and land uses. Here we evaluate the performance of nitrate, fluorescent dissolved organic matter (fDOM), and turbidity sensors included in the sensor network. Nitrate sensors were first evaluated in the laboratory for interference by different forms of dissolved organic carbon (DOC), and then for accuracy in the field across a range of hydrochemical conditions. Turbidity sensors were assessed for their effectiveness as a proxy for concentrations of total suspended solids (TSS) and total particulate C and N, and fDOM as a proxy for concentrations of dissolved organic matter. Overall sensor platform performance was also examined by estimating percentage of data loss due to sensor failures or related malfunctions. Although laboratory sensor trials show that DOC can affect optical nitrate measurements, our validations with grab samples showed that the optical nitrate sensors provide a reliable measurement of NO3 concentrations across a wide range of conditions. Results showed that fDOM is a good proxy for DOC concentration (r2 = 0.82) but is a less effective proxy for dissolved organic nitrogen (r2 = 0.41). Turbidity measurements from sensors correlated well with TSS (r2 = 0.78), PC (r2 = 0.53), and PN (r2 = 0.51).
- 30 March 2018
- Published by American Geophysical Union (AGU) in Water Resources Research
- Vol. 54 (3) , 2466-2479
Open AccessAn Evaluation of Nitrate, fDOM, and Turbidity Sensors in New Hampshire Streams
A state‐of‐the‐art network of water quality sensors was established in 2012 to gather year‐round high temporal frequency hydrochemical data in streams and rivers throughout the state of New Hampshire. This spatially extensive network includes eight headwater stream and two main stem river monitoring sites, spanning a variety of stream orders and land uses. Here we evaluate the performance of nitrate, fluorescent dissolved organic matter (fDOM), and turbidity sensors included in the sensor network. Nitrate sensors were first evaluated in the laboratory for interference by different forms of dissolved organic carbon (DOC), and then for accuracy in the field across a range of hydrochemical conditions. Turbidity sensors were assessed for their effectiveness as a proxy for concentrations of total suspended solids (TSS) and total particulate C and N, and fDOM as a proxy for concentrations of dissolved organic matter. Overall sensor platform performance was also examined by estimating percentage of data loss due to sensor failures or related malfunctions. Although laboratory sensor trials show that DOC can affect optical nitrate measurements, our validations with grab samples showed that the optical nitrate sensors provide a reliable measurement of NO3 concentrations across a wide range of conditions. Results showed that fDOM is a good proxy for DOC concentration (r2 = 0.82) but is a less effective proxy for dissolved organic nitrogen (r2 = 0.41). Turbidity measurements from sensors correlated well with TSS (r2 = 0.78), PC (r2 = 0.53), and PN (r2 = 0.51).
- Open Access
- 10 January 2018
- Published by Consortium of Universities for the Advancement of Hydrologic Science, Inc. (CUAHSI)
New Hampshire EPSCoR Intensive Aquatic Network continuous Discharge, Nitrate, fDOM, Temperature, and Specific Conductance Data
New Hampshire EPSCoR Intensive Aquatic Network Flow and Sensor Data
- 10 January 2018
- Published by Consortium of Universities for the Advancement of Hydrologic Science, Inc. (CUAHSI)
Open AccessNew Hampshire EPSCoR Intensive Aquatic Network continuous Discharge, Nitrate, fDOM, Temperature, and Specific Conductance Data
New Hampshire EPSCoR Intensive Aquatic Network Flow and Sensor Data
- Open Access
- 21 December 2017
- Published by American Geophysical Union (AGU) in Water Resources Research
- Vol. 53 (12) , 10655-10673
Deconstructing the Effects of Flow on DOC, Nitrate, and Major Ion Interactions Using a High‐Frequency Aquatic Sensor Network
- 21 December 2017
- Published by American Geophysical Union (AGU) in Water Resources Research
- Vol. 53 (12) , 10655-10673
Open AccessDeconstructing the Effects of Flow on DOC, Nitrate, and Major Ion Interactions Using a High‐Frequency Aquatic Sensor Network
- Open Access
- 20 February 2014
- Published by American Geophysical Union (AGU) in Water Resources Research
- Vol. 50 (3) , 2039-2049
Nutrient dynamics in an oligotrophic arctic stream monitored in situ by wet chemistry methods
Diurnal trends in hydrochemical components of stream and river water, especially nutrients, is growing in interest as instrumentation capable of measuring at fine time scales becomes increasingly available. In this growing body of work, there are few studies that simultaneously report the dynamics of the major nutrients nitrate, phosphate, and ammonium through time. We used an in situ nutrient autoanalyzer to simultaneously measure nitrate, phosphate, and ammonium concentrations with wet chemistry methods in an arctic headwater stream. We operated the analyzer under two sampling regimes: (1) time interval (hourly) sampling to examine fine time scale nutrient dynamics and (2) continuous sampling (1 s data) to evaluate nutrient uptake from a pulse solute addition experiment. Hourly sampling showed inverse diurnal oscillating trends of nitrate and ammonium concentrations for several days during base flow conditions. We propose that this trend is a result of in‐stream nutrient processing (autotrophic demand and nitrification) combined with increased lateral inputs of water from the active (thawed) soil layer at night, after evapotranspiration (ET) has ceased. Pulse additions of ammonium resulted in rapid increases in nitrate concentration, confirming potential magnitude of nitrification in this system. Phosphate concentrations were usually at or below detection limits, consistent with results from previous manual sampling of this stream. We conclude that as studies examining fine time scale nutrient trends in streams and rivers increase, the ability to examine the behavior of multiple nutrients simultaneously will be pertinent to assess the underlying mechanisms driving those trends.
- 20 February 2014
- Published by American Geophysical Union (AGU) in Water Resources Research
- Vol. 50 (3) , 2039-2049
Open AccessNutrient dynamics in an oligotrophic arctic stream monitored in situ by wet chemistry methods
Diurnal trends in hydrochemical components of stream and river water, especially nutrients, is growing in interest as instrumentation capable of measuring at fine time scales becomes increasingly available. In this growing body of work, there are few studies that simultaneously report the dynamics of the major nutrients nitrate, phosphate, and ammonium through time. We used an in situ nutrient autoanalyzer to simultaneously measure nitrate, phosphate, and ammonium concentrations with wet chemistry methods in an arctic headwater stream. We operated the analyzer under two sampling regimes: (1) time interval (hourly) sampling to examine fine time scale nutrient dynamics and (2) continuous sampling (1 s data) to evaluate nutrient uptake from a pulse solute addition experiment. Hourly sampling showed inverse diurnal oscillating trends of nitrate and ammonium concentrations for several days during base flow conditions. We propose that this trend is a result of in‐stream nutrient processing (autotrophic demand and nitrification) combined with increased lateral inputs of water from the active (thawed) soil layer at night, after evapotranspiration (ET) has ceased. Pulse additions of ammonium resulted in rapid increases in nitrate concentration, confirming potential magnitude of nitrification in this system. Phosphate concentrations were usually at or below detection limits, consistent with results from previous manual sampling of this stream. We conclude that as studies examining fine time scale nutrient trends in streams and rivers increase, the ability to examine the behavior of multiple nutrients simultaneously will be pertinent to assess the underlying mechanisms driving those trends.