Jan C. T. Eijkel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jan C. T. Eijkel has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Albert van Den Berg
BIOS lab-on-a-chip group, University of Twente, Enschede, the Netherlands
6 shared publications - Jeanne Elisabeth van Dongen
Clinical Laboratory, Catharina Hospital Eindhoven, 5623 EJ, Eindhoven, the Netherlands
2 shared publications - Johanna Theodora Wilhelmina Berendsen
BIOS Lab on a Chip Group, University of Twente
2 shared publications - Loes Irene Segerink
BIOS Lab‐on‐chip group University of Twente Enschede The Netherlands
2 shared publications A. van Den Berg
BIOS-Lab on a Chip Group, MESA+ Institute of Nanotechnology, MIRA Institute for Biomedical Technology and Technical Medicine, Max Planck - University of Twente Center for Complex Fluid Dynamics, University of Twente, The Netherlands
1 shared publication- Akihide Hibara
Department of Chemistry, School of Science, Institute of Science Tokyo, 2-12-1 Ookayama, Meguro-ku, Tokyo 152-8551, Japan
1 shared publication
Latest Publications
- Open Access
- 1 December 2021
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 194, 113624
A CRISPR/Cas12a-assisted in vitro diagnostic tool for identification and quantification of single CpG methylation sites
- 1 December 2021
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 194, 113624
Open AccessA CRISPR/Cas12a-assisted in vitro diagnostic tool for identification and quantification of single CpG methylation sites
- Open Access
A CRISPR/Cas12a-assisted platform for identification and quantification of single CpG methylation sites
Clustered Regularly Interspaced Short Palindromic Repeats (CRISPR)/associated nuclease (Cas) systems have repeatedly shown to have excellent performance in nucleotide sensing applications 1–5 . High specificity and selectivity of Cas effector proteins is determined by the CRISPR RNA’s (crRNA’s) interchangeable spacer sequence, as well as position and number of mismatches between target sequence and the crRNA sequence 1 . Some diseases are characterized by epigenetic alterations rather than nucleotide changes, and are therefore unsuitable for CRISPR-assisted sensing methods. Here we demonstrate a method to discriminate single CpG site methylation in DNA, which is an epigenetic alteration, by the use of methylation-sensitive restriction enzymes (MSREs) followed by Cas12a-assisted sensing. Non-methylated sequences are digested by MSREs, resulting in fragmentation of the target sequence that influences the R-loop formation between crRNA and target DNA. We show that fragment size, fragmentation position and number of fragments influence the subsequent collateral trans -cleavage activity towards single stranded DNA (ssDNA), enabling deducting the methylation position from the cleavage activity. Utilizing MSREs in combination with Cas12a, single CpG site methylation levels of a cancer gene were for the first time determined. The modularity of both Cas12a and MSREs provide a high level of versatility to the Cas12a–MSRE combined sensing method, which opens the possibility to easily and rapidly study single CpG methylation sites for disease detection.
Open AccessA CRISPR/Cas12a-assisted platform for identification and quantification of single CpG methylation sites
Clustered Regularly Interspaced Short Palindromic Repeats (CRISPR)/associated nuclease (Cas) systems have repeatedly shown to have excellent performance in nucleotide sensing applications 1–5 . High specificity and selectivity of Cas effector proteins is determined by the CRISPR RNA’s (crRNA’s) interchangeable spacer sequence, as well as position and number of mismatches between target sequence and the crRNA sequence 1 . Some diseases are characterized by epigenetic alterations rather than nucleotide changes, and are therefore unsuitable for CRISPR-assisted sensing methods. Here we demonstrate a method to discriminate single CpG site methylation in DNA, which is an epigenetic alteration, by the use of methylation-sensitive restriction enzymes (MSREs) followed by Cas12a-assisted sensing. Non-methylated sequences are digested by MSREs, resulting in fragmentation of the target sequence that influences the R-loop formation between crRNA and target DNA. We show that fragment size, fragmentation position and number of fragments influence the subsequent collateral trans -cleavage activity towards single stranded DNA (ssDNA), enabling deducting the methylation position from the cleavage activity. Utilizing MSREs in combination with Cas12a, single CpG site methylation levels of a cancer gene were for the first time determined. The modularity of both Cas12a and MSREs provide a high level of versatility to the Cas12a–MSRE combined sensing method, which opens the possibility to easily and rapidly study single CpG methylation sites for disease detection.
- Open Access
- 11 January 2019
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 19 (3) , 452-463
Non-invasive sensing of transepithelial barrier function and tissue differentiation in organs-on-chips using impedance spectroscopy
Here, we describe methods for combining impedance spectroscopy measurements with electrical simulation to reveal transepithelial barrier function and tissue structure of human intestinal epithelium cultured inside an organ-on-chip microfluidic culture device. When performing impedance spectroscopy measurements, electrical simulation enabled normalization of cell layer resistance of epithelium cultured statically in a gut-on-a-chip, which enabled determination of transepithelial electrical resistance (TEER) values that can be compared across device platforms. During culture under dynamic flow, the formation of intestinal villi was accompanied by characteristic changes in impedance spectra both measured experimentally and verified with simulation, and we demonstrate that changes in cell layer capacitance may serve as measures of villi differentiation. This method for combining impedance spectroscopy with simulation can be adapted to better monitor cell layer characteristics within any organ-on-chip in vitro and to enable direct quantitative TEER comparisons between organ-on-chip platforms which should help to advance research on organ function.
- 11 January 2019
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 19 (3) , 452-463
Open AccessNon-invasive sensing of transepithelial barrier function and tissue differentiation in organs-on-chips using impedance spectroscopy
Here, we describe methods for combining impedance spectroscopy measurements with electrical simulation to reveal transepithelial barrier function and tissue structure of human intestinal epithelium cultured inside an organ-on-chip microfluidic culture device. When performing impedance spectroscopy measurements, electrical simulation enabled normalization of cell layer resistance of epithelium cultured statically in a gut-on-a-chip, which enabled determination of transepithelial electrical resistance (TEER) values that can be compared across device platforms. During culture under dynamic flow, the formation of intestinal villi was accompanied by characteristic changes in impedance spectra both measured experimentally and verified with simulation, and we demonstrate that changes in cell layer capacitance may serve as measures of villi differentiation. This method for combining impedance spectroscopy with simulation can be adapted to better monitor cell layer characteristics within any organ-on-chip in vitro and to enable direct quantitative TEER comparisons between organ-on-chip platforms which should help to advance research on organ function.
- Open Access
- 1 February 2018
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1000, 232-238
3D capillary stop valves for versatile patterning inside microfluidic chips
- 1 February 2018
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1000, 232-238
Open Access3D capillary stop valves for versatile patterning inside microfluidic chips
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 110-114
Ballistic energy conversion
Ballistic energy conversion is the direct conversion of kinetic energy into electrical energy. Aqueous droplet-based platforms are eminently suitable for this method, as droplets can be conveniently supplied with both kinetic energy and electrical charge. Starting with the 19 th century gravity-driven Kelvin thunderstorm and the electrostatic generators of Melcher and Zahn from the 1960s, we describe the recent development of ballistic energy conversion both in experiment and theory. With this method experimental efficiencies of 48% have been reached at 20 kV operating voltage with an extremely simple setup. Theory predicts maximal efficiencies of more than 90%, operation at <;100 Volt. Downscaling also promises to remove one of the largest disadvantages of electrostatic generators, namely the low power density: power densities of 1-1000 kW/m 2 are predicted.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 110-114
Ballistic energy conversion
Ballistic energy conversion is the direct conversion of kinetic energy into electrical energy. Aqueous droplet-based platforms are eminently suitable for this method, as droplets can be conveniently supplied with both kinetic energy and electrical charge. Starting with the 19 th century gravity-driven Kelvin thunderstorm and the electrostatic generators of Melcher and Zahn from the 1960s, we describe the recent development of ballistic energy conversion both in experiment and theory. With this method experimental efficiencies of 48% have been reached at 20 kV operating voltage with an extremely simple setup. Theory predicts maximal efficiencies of more than 90%, operation at <;100 Volt. Downscaling also promises to remove one of the largest disadvantages of electrostatic generators, namely the low power density: power densities of 1-1000 kW/m 2 are predicted.
- 7 September 2016
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 6 (92) , 89380-89386
Spatial control of direct chemical vapor deposition of graphene on silicon dioxide by directional copper dewetting
A non-manual, controllable and wafer-scale method for the spatial control of direct graphene synthesis onto silicon dioxide by controlled dewetting and evaporation of copper.
- 7 September 2016
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 6 (92) , 89380-89386
Spatial control of direct chemical vapor deposition of graphene on silicon dioxide by directional copper dewetting
A non-manual, controllable and wafer-scale method for the spatial control of direct graphene synthesis onto silicon dioxide by controlled dewetting and evaporation of copper.
- 27 July 2016
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 88 (16) , 7890-7893
Ion-Step Method for Surface Potential Sensing of Silicon Nanowires
This paper presents a novel stimulus-response method for surface potential sensing of silicon nanowire (Si NW) field-effect transistors. When an "ion-step" from low to high ionic strength is given as a stimulus to the gate oxide surface, an increase of double layer capacitance is therefore expected. Thus, a change of conductance through the Si-NWs is measured. The surface potential on the Si-NW gate is changed from negative for a bare SiO2 surface to neutral/ positive when there is poly-L-lysine adsorption at certain pH, which also indicates a shift of point-of-zero charge pH after surface modification. This change is measured by a drop of current variation at the ion-step. The ion-step is performed to the Si-NW through a polydimethylsiloxane microfluidic chip with automatic sample switching. A reduction of the ion-step response from 2 nA to almost zero at pH 5.0 is observed by increasing the potassium ion concentration from 10 mM to 50 mM, which corresponds to a surface potential change of similar to 12 mV. We show that this method can be used as an alternative method for surface potential sensing, making it less sensitive to drift
- 27 July 2016
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 88 (16) , 7890-7893
Ion-Step Method for Surface Potential Sensing of Silicon Nanowires
This paper presents a novel stimulus-response method for surface potential sensing of silicon nanowire (Si NW) field-effect transistors. When an "ion-step" from low to high ionic strength is given as a stimulus to the gate oxide surface, an increase of double layer capacitance is therefore expected. Thus, a change of conductance through the Si-NWs is measured. The surface potential on the Si-NW gate is changed from negative for a bare SiO2 surface to neutral/ positive when there is poly-L-lysine adsorption at certain pH, which also indicates a shift of point-of-zero charge pH after surface modification. This change is measured by a drop of current variation at the ion-step. The ion-step is performed to the Si-NW through a polydimethylsiloxane microfluidic chip with automatic sample switching. A reduction of the ion-step response from 2 nA to almost zero at pH 5.0 is observed by increasing the potassium ion concentration from 10 mM to 50 mM, which corresponds to a surface potential change of similar to 12 mV. We show that this method can be used as an alternative method for surface potential sensing, making it less sensitive to drift
- 1 January 2013
- Published by The Polarographic Society of Japan in Review of Polarography
- Vol. 59 (1) , 13-19
Electrochemical Analysis of Microfluidic Droplet Formation
- 1 January 2013
- Published by The Polarographic Society of Japan in Review of Polarography
- Vol. 59 (1) , 13-19
Electrochemical Analysis of Microfluidic Droplet Formation
- 5 April 2008
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 8 (7) , 1785-1790
Field-Dependent DNA Mobility in 20 nm High Nanoslits
- 5 April 2008
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 8 (7) , 1785-1790
Field-Dependent DNA Mobility in 20 nm High Nanoslits