Nur Hartini Mohd Taib
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Nur Hartini Mohd Taib has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
Ibrahim Lutfi Shuaib
Univ Sains Malaysia, Adv Med & Dent Inst, Kepala Batas 13200, Penang, Malaysia
5 shared publicationsSuzana Mat Isa
Univ Sains Malaysia, Adv Med & Dent Inst, Kepala Batas 13200, Penang, Malaysia
5 shared publications- Ahmad Fairuz Omar
Department of Hepatology, Gastroenterology& Infectious Diseases, Faculty of Medicine, Zagazig University, Zagazig, Egypt
4 shared publications - Edrine Damulira
Medical Radiation Programme, School of Health Sciences, Universiti Sains Malaysia, 16150 Kubang Kerian, Kelantan, Malaysia
4 shared publications - Muhammad Nur Salihin Yusoff
Medical Radiation Programme, School of Health Sciences, Universiti Sains Malaysia, Kubang Kerian 16150, Malaysia
4 shared publications Wan Ahmad Kamil Wan Abdullah
Univ Sains Malaysia, Sch Med Sci, Dept Radiol, Hlth Campus, Kubang Kerian 16150, Kelantan Darul, Malaysia
4 shared publications
Latest Publications
- 1 January 2025
- Vol. 80 (1) , 88-95
Quantitative characterisation of carotid atherosclerotic plaque neovascularisation using contrast-enhanced ultrasound imaging: A feasibility study.
Contrast-enhanced ultrasound (CEUS), an in vivo imaging tool for evaluating intraplaque neovascularisation (IPN), is an increasingly researched marker of susceptible atherosclerotic plaque. This study aims to assess the feasibility of quantifying carotid IPN using CEUS and to identify and characterise the neovascularisation in carotid plaques. The hospital's ethical committee approved the study, and the informed individual consent form of CEUS was obtained from all patients before the examination. Seventy-one patients with carotid atherosclerotic plaques (95 plaques) were studied on CEUS. Contrast enhancement in the plaque was evaluated with visual interpretation and quantitative analysis. The intraplaque neovascularisation (IPN) test was graded on a 3- point scale. IPN was quantified using dedicated software for CEUS image analysis. It was found that the CEUS quantitative parameters were significantly different for plaques with varying types of echoes. The quantitative parameters also differed in soft, hard, and mixed plaques. The quantification of carotid IPN using CEUS was found feasible. The quantitative parameters measured from CEUS provide multiple references for carotid IPN of different echo types. This can help identify and monitor unstable atherosclerotic plaques. CEUS has the potential to be an important tool in clinical application, specifically for diagnosing carotid atherosclerotic plaque features and vulnerability.
- 1 January 2025
- Vol. 80 (1) , 88-95
Quantitative characterisation of carotid atherosclerotic plaque neovascularisation using contrast-enhanced ultrasound imaging: A feasibility study.
Contrast-enhanced ultrasound (CEUS), an in vivo imaging tool for evaluating intraplaque neovascularisation (IPN), is an increasingly researched marker of susceptible atherosclerotic plaque. This study aims to assess the feasibility of quantifying carotid IPN using CEUS and to identify and characterise the neovascularisation in carotid plaques. The hospital's ethical committee approved the study, and the informed individual consent form of CEUS was obtained from all patients before the examination. Seventy-one patients with carotid atherosclerotic plaques (95 plaques) were studied on CEUS. Contrast enhancement in the plaque was evaluated with visual interpretation and quantitative analysis. The intraplaque neovascularisation (IPN) test was graded on a 3- point scale. IPN was quantified using dedicated software for CEUS image analysis. It was found that the CEUS quantitative parameters were significantly different for plaques with varying types of echoes. The quantitative parameters also differed in soft, hard, and mixed plaques. The quantification of carotid IPN using CEUS was found feasible. The quantitative parameters measured from CEUS provide multiple references for carotid IPN of different echo types. This can help identify and monitor unstable atherosclerotic plaques. CEUS has the potential to be an important tool in clinical application, specifically for diagnosing carotid atherosclerotic plaque features and vulnerability.
- Open Access
The Assessment of White Matter Integrity Alteration Pattern in Patients with Brain Tumor Utilizing Diffusion Tensor Imaging: A Systematic Review
Alteration in the surrounding brain tissue may occur in the presence of a brain tumor. The present study aims to assess the characteristics and criteria of the pattern of white matter tract microstructure integrity alteration in brain tumor patients. The Scopus, PubMed/Medline, and Web of Science electronic databases were searched for related articles based on the guidelines established by PRISMA. Twenty-five studies were selected on the morphological changes of white matter tract integrity based on the differential classification of white matter tract (WMT) patterns in brain tumor patients through diffusion tensor imaging (DTI). The characterization was based on two criteria: the visualization of the tract—its orientation and position—and the DTI parameters, which were the fractional anisotropy and apparent diffusion coefficient. Individual evaluations revealed no absolute, mutually exclusive type of tumor in relation to morphological WMT microstructure integrity changes. In most cases, different types and grades of tumors have shown displacement or infiltration. Characterizing morphological changes in the integrity of the white matter tract microstructures is vital in the diagnostic and prognostic evaluation of the tumor’s progression and could be a potential assessment for the early detection of possible neurological defects that may affect the patient, as well as aiding in surgery decision-making.
Open AccessThe Assessment of White Matter Integrity Alteration Pattern in Patients with Brain Tumor Utilizing Diffusion Tensor Imaging: A Systematic Review
Alteration in the surrounding brain tissue may occur in the presence of a brain tumor. The present study aims to assess the characteristics and criteria of the pattern of white matter tract microstructure integrity alteration in brain tumor patients. The Scopus, PubMed/Medline, and Web of Science electronic databases were searched for related articles based on the guidelines established by PRISMA. Twenty-five studies were selected on the morphological changes of white matter tract integrity based on the differential classification of white matter tract (WMT) patterns in brain tumor patients through diffusion tensor imaging (DTI). The characterization was based on two criteria: the visualization of the tract—its orientation and position—and the DTI parameters, which were the fractional anisotropy and apparent diffusion coefficient. Individual evaluations revealed no absolute, mutually exclusive type of tumor in relation to morphological WMT microstructure integrity changes. In most cases, different types and grades of tumors have shown displacement or infiltration. Characterizing morphological changes in the integrity of the white matter tract microstructures is vital in the diagnostic and prognostic evaluation of the tumor’s progression and could be a potential assessment for the early detection of possible neurological defects that may affect the patient, as well as aiding in surgery decision-making.
- 12 April 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (8) , 085001
Development and characterization of an LED-based detector for dosimetry in diagnostic radiology
Light-emitting diodes (LEDs) could be a potential dosimetry candidate because they are radiation hard, spectrally selective, direct band gap, and low-cost devices. Thus, an LED-based detector prototype was designed and characterized for dosimetry. A 20 × 20 cm 2 array of surface mount device LED chips was sandwiched in photovoltaic mode between two intensifying screens to form a dosimetric system. The system was enclosed in a light-tight air cavity using black vinyl tape. The screens converted diagnostic x-ray beams into fluorescent blue light. LEDs, applied in detector mode, converted the fluorescent light into radiation-induced currents. A digital multimeter converted the analog currents into digital voltage signals. Prototype characterization was executed using (a) IEC 61267’s RQR 7 (90 kVp) and RQR 8 (100 kVp) beam qualities, and (b) low (25 mAs) and high (80 mAs) beam quantities. A standard dosimeter probe was simultaneously exposed with the prototype to measure the prototype’s absorbed dose. In all exposures, the x-ray beams were perpendicularly incident on both the dosimeter and prototype, at a fixed source to detector distance-60 cm. The LED array prototype’s minimum detectable dose was 0.139 mGy, and the maximum dose implemented herein was ∼13 mGy. The prototype was 99.18% and 98.64% linearly sensitive to absorbed dose and tube current–time product (mAs), respectively. The system was ±4.69% energy, ±6.8% dose, and ±7.7% dose rate dependent. Two prototype data sets were 89.93% repeatable. We fabricated an ultrathin (5 mm), lightweight (130 g), and a relatively low-cost LED-based dosimetric prototype. The prototype executed a simple, efficient, and accurate real-time dosimetric mechanism. It could thus be an alternative to the current passive dosimetric systems.
- 12 April 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (8) , 085001
Development and characterization of an LED-based detector for dosimetry in diagnostic radiology
Light-emitting diodes (LEDs) could be a potential dosimetry candidate because they are radiation hard, spectrally selective, direct band gap, and low-cost devices. Thus, an LED-based detector prototype was designed and characterized for dosimetry. A 20 × 20 cm 2 array of surface mount device LED chips was sandwiched in photovoltaic mode between two intensifying screens to form a dosimetric system. The system was enclosed in a light-tight air cavity using black vinyl tape. The screens converted diagnostic x-ray beams into fluorescent blue light. LEDs, applied in detector mode, converted the fluorescent light into radiation-induced currents. A digital multimeter converted the analog currents into digital voltage signals. Prototype characterization was executed using (a) IEC 61267’s RQR 7 (90 kVp) and RQR 8 (100 kVp) beam qualities, and (b) low (25 mAs) and high (80 mAs) beam quantities. A standard dosimeter probe was simultaneously exposed with the prototype to measure the prototype’s absorbed dose. In all exposures, the x-ray beams were perpendicularly incident on both the dosimeter and prototype, at a fixed source to detector distance-60 cm. The LED array prototype’s minimum detectable dose was 0.139 mGy, and the maximum dose implemented herein was ∼13 mGy. The prototype was 99.18% and 98.64% linearly sensitive to absorbed dose and tube current–time product (mAs), respectively. The system was ±4.69% energy, ±6.8% dose, and ±7.7% dose rate dependent. Two prototype data sets were 89.93% repeatable. We fabricated an ultrathin (5 mm), lightweight (130 g), and a relatively low-cost LED-based dosimetric prototype. The prototype executed a simple, efficient, and accurate real-time dosimetric mechanism. It could thus be an alternative to the current passive dosimetric systems.
- 30 April 2020
- Published by Penerbit Universiti Kebangsaan Malaysia (UKM Press) in Sains Malaysiana
- Vol. 49 (4) , 793-800
Relationship between Volume of Leukoaraiosis Spot and Degree of Tissue Damage: A Quantitative Diffusion Tensor Imaging Study
- 30 April 2020
- Published by Penerbit Universiti Kebangsaan Malaysia (UKM Press) in Sains Malaysiana
- Vol. 49 (4) , 793-800
Relationship between Volume of Leukoaraiosis Spot and Degree of Tissue Damage: A Quantitative Diffusion Tensor Imaging Study
- Open Access
- 16 January 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (2) , 651
Amplification of Radiation-Induced Signal of LED Strip by Increasing Number of LED Chips and Using Amplifier Board
Transducers, such as photodiodes, phototransistors, and photovoltaic cells are promising radiation detectors. However, for accurate radiation detection and dosimetry, signals that emanate from these devices have to be sufficient to facilitate accurate calibrations, i.e., assigning a quantity of radiation dose to a specific magnitude of the signal. More so, purposely fabricated for luminescence, LEDs produce significantly low signals during radiation detection applications. Therefore, this paper investigates the enhancement and augmentation of photovoltaic signals that were generated when LED strips were being exposed to diagnostic X-rays. Initially, signal amplification was achieved through increasing the effective LED active area (from 60 to 120 chips); by successively connecting LED strips. Further, signal amplification was undertaken by injecting the raw LED strip signal into an amplifier board with adjustable gains. In both the signal amplification techniques, the tube voltage (kVp), tube current-time product (mAs), and source-to-detector distance (SDD) were varied. The principal findings show that effective active area-based signal amplifications produced an overall average of 91.16% signal enhancement throughout all of the X-ray parameter variations. On the other hand, the amplifier board produced an average of 36.48% signal enhancement for the signals that were injected into it. Chip number increment-based signal amplifications had a 0.687% less coefficient of variation than amplifier board signal amplifications. The amplifier board signal amplifications were impaired by factors, such as dark currents, amplifier board maximum operational output voltage, and saturation. Therefore, future electronic signal amplification could use amplifier boards having low dark currents and high operational voltage headroom. The low-cost and simplicity that are associated with active-area amplification could be further exploited in a hybrid amplification technique with electronic amplification and scintillators.
- 16 January 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (2) , 651
Open AccessAmplification of Radiation-Induced Signal of LED Strip by Increasing Number of LED Chips and Using Amplifier Board
Transducers, such as photodiodes, phototransistors, and photovoltaic cells are promising radiation detectors. However, for accurate radiation detection and dosimetry, signals that emanate from these devices have to be sufficient to facilitate accurate calibrations, i.e., assigning a quantity of radiation dose to a specific magnitude of the signal. More so, purposely fabricated for luminescence, LEDs produce significantly low signals during radiation detection applications. Therefore, this paper investigates the enhancement and augmentation of photovoltaic signals that were generated when LED strips were being exposed to diagnostic X-rays. Initially, signal amplification was achieved through increasing the effective LED active area (from 60 to 120 chips); by successively connecting LED strips. Further, signal amplification was undertaken by injecting the raw LED strip signal into an amplifier board with adjustable gains. In both the signal amplification techniques, the tube voltage (kVp), tube current-time product (mAs), and source-to-detector distance (SDD) were varied. The principal findings show that effective active area-based signal amplifications produced an overall average of 91.16% signal enhancement throughout all of the X-ray parameter variations. On the other hand, the amplifier board produced an average of 36.48% signal enhancement for the signals that were injected into it. Chip number increment-based signal amplifications had a 0.687% less coefficient of variation than amplifier board signal amplifications. The amplifier board signal amplifications were impaired by factors, such as dark currents, amplifier board maximum operational output voltage, and saturation. Therefore, future electronic signal amplification could use amplifier boards having low dark currents and high operational voltage headroom. The low-cost and simplicity that are associated with active-area amplification could be further exploited in a hybrid amplification technique with electronic amplification and scintillators.
- Open Access
- 26 December 2019
- Published by MDPI AG in Applied Sciences
- Vol. 10 (1) , 200
Comparison of Current–Voltage Response to Diagnostic X-rays of Five Light-Emitting Diode Strips
Light-emitting diodes (LEDs) have miscellaneous applications owing to their low cost, small size, flexibility, and commercial availability. Furthermore, LEDs have dual applicability as light emitters and detectors. This study explores the current–voltage (C–V) response of LED strips exposed to diagnostic x-rays. Cold white, warm white, red, green, and blue LED strip colors were tested. Each strip consisted of 12 LED chips and was connected to a multimeter. The variable diagnostic x-ray parameters evaluated were kilovoltage peak (kVp), milliampere-seconds (mAs), and source-to-image distance (SID). The radiation dose was also measured using a dosimeter simultaneously exposed to x-rays perpendicularly incident on the strips. Lastly, the consistency of C–V responses, and any possible degradation after 1–2 months was also analyzed. Each LED strip color was ranked according to its C–V response in each of the investigated parameters. The LED strip color with the best cumulative rank across all the tested parameters was then examined for reproducibility. Our findings revealed that the C–V responses of LED strips are (a) generally low but measurable, (b) inconsistent and fluctuating as a consequence of kVp variations, (c) positively correlated to mAs, (d) negatively correlated to SID, and (e) positively correlated to dose. Overall results suggested cold white LED strip as most feasible for x-ray detection—in comparison to examined colors. Additionally, the reproducibility study using the cold white LED strip found a similar trend of C–V response to all variables except kVp. Outcomes indicate that LED strips have the potential to be exploited for detecting low dose (~0–100 mGy) diagnostic x-rays. However, future studies should be carried out to increase the low C–V signal.
- 26 December 2019
- Published by MDPI AG in Applied Sciences
- Vol. 10 (1) , 200
Open AccessComparison of Current–Voltage Response to Diagnostic X-rays of Five Light-Emitting Diode Strips
Light-emitting diodes (LEDs) have miscellaneous applications owing to their low cost, small size, flexibility, and commercial availability. Furthermore, LEDs have dual applicability as light emitters and detectors. This study explores the current–voltage (C–V) response of LED strips exposed to diagnostic x-rays. Cold white, warm white, red, green, and blue LED strip colors were tested. Each strip consisted of 12 LED chips and was connected to a multimeter. The variable diagnostic x-ray parameters evaluated were kilovoltage peak (kVp), milliampere-seconds (mAs), and source-to-image distance (SID). The radiation dose was also measured using a dosimeter simultaneously exposed to x-rays perpendicularly incident on the strips. Lastly, the consistency of C–V responses, and any possible degradation after 1–2 months was also analyzed. Each LED strip color was ranked according to its C–V response in each of the investigated parameters. The LED strip color with the best cumulative rank across all the tested parameters was then examined for reproducibility. Our findings revealed that the C–V responses of LED strips are (a) generally low but measurable, (b) inconsistent and fluctuating as a consequence of kVp variations, (c) positively correlated to mAs, (d) negatively correlated to SID, and (e) positively correlated to dose. Overall results suggested cold white LED strip as most feasible for x-ray detection—in comparison to examined colors. Additionally, the reproducibility study using the cold white LED strip found a similar trend of C–V response to all variables except kVp. Outcomes indicate that LED strips have the potential to be exploited for detecting low dose (~0–100 mGy) diagnostic x-rays. However, future studies should be carried out to increase the low C–V signal.
- Open Access
- 1 November 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1372 (1) , 012039
Analysis of genu and splenium of the corpus callosum: comparison between healthy subjects with and without Leukoaraiosis
The purpose of this study to investigate whether there are any differences in Diffusion Tensor Imaging (DTI) values in subjects that have leukoaraiosis (LA) in the frontal white matter (fWM) and occipital white matter (oWM) compared to subjects that have no LA in those areas in the brain. DTI indices namely axial diffusivity (AD), radial diffusivity (RD), mean diffusivity (MD), fractional anisotropy (FA) were measured via retrospective study. Finding from this study shows that there is no significant difference in AD, RD, MD, and FA values between both groups. It is concluded that there are no significant differences in DTI values of genu and splenium of the corpus callosum between subjects with and without LA. This study shows that subjects with LA does not having degeneration on fiber bundles of the genu and splenium, in which the genu and splenium function in connecting right and left of hemisphere. Also, it might does not affect or not yet affect the genu and splenium fiber bundles. This finding the differences is important to determine whether any changes in AD and RD values.
- 1 November 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1372 (1) , 012039
Open AccessAnalysis of genu and splenium of the corpus callosum: comparison between healthy subjects with and without Leukoaraiosis
The purpose of this study to investigate whether there are any differences in Diffusion Tensor Imaging (DTI) values in subjects that have leukoaraiosis (LA) in the frontal white matter (fWM) and occipital white matter (oWM) compared to subjects that have no LA in those areas in the brain. DTI indices namely axial diffusivity (AD), radial diffusivity (RD), mean diffusivity (MD), fractional anisotropy (FA) were measured via retrospective study. Finding from this study shows that there is no significant difference in AD, RD, MD, and FA values between both groups. It is concluded that there are no significant differences in DTI values of genu and splenium of the corpus callosum between subjects with and without LA. This study shows that subjects with LA does not having degeneration on fiber bundles of the genu and splenium, in which the genu and splenium function in connecting right and left of hemisphere. Also, it might does not affect or not yet affect the genu and splenium fiber bundles. This finding the differences is important to determine whether any changes in AD and RD values.
- Open Access
A Review: Photonic Devices Used for Dosimetry in Medical Radiation
Numerous instruments such as ionization chambers, hand-held and pocket dosimeters of various types, film badges, thermoluminescent dosimeters (TLDs) and optically stimulated luminescence dosimeters (OSLDs) are used to measure and monitor radiation in medical applications. Of recent, photonic devices have also been adopted. This article evaluates recent research and advancements in the applications of photonic devices in medical radiation detection primarily focusing on four types; photodiodes – including light-emitting diodes (LEDs), phototransistors—including metal oxide semiconductor field effect transistors (MOSFETs), photovoltaic sensors/solar cells, and charge coupled devices/charge metal oxide semiconductors (CCD/CMOS) cameras. A comprehensive analysis of the operating principles and recent technologies of these devices is performed. Further, critical evaluation and comparison of their benefits and limitations as dosimeters is done based on the available studies. Common factors barring photonic devices from being used as radiation detectors are also discussed; with suggestions on possible solutions to overcome these barriers. Finally, the potentials of these devices and the challenges of realizing their applications as quintessential dosimeters are highlighted for future research and improvements.
Open AccessA Review: Photonic Devices Used for Dosimetry in Medical Radiation
Numerous instruments such as ionization chambers, hand-held and pocket dosimeters of various types, film badges, thermoluminescent dosimeters (TLDs) and optically stimulated luminescence dosimeters (OSLDs) are used to measure and monitor radiation in medical applications. Of recent, photonic devices have also been adopted. This article evaluates recent research and advancements in the applications of photonic devices in medical radiation detection primarily focusing on four types; photodiodes – including light-emitting diodes (LEDs), phototransistors—including metal oxide semiconductor field effect transistors (MOSFETs), photovoltaic sensors/solar cells, and charge coupled devices/charge metal oxide semiconductors (CCD/CMOS) cameras. A comprehensive analysis of the operating principles and recent technologies of these devices is performed. Further, critical evaluation and comparison of their benefits and limitations as dosimeters is done based on the available studies. Common factors barring photonic devices from being used as radiation detectors are also discussed; with suggestions on possible solutions to overcome these barriers. Finally, the potentials of these devices and the challenges of realizing their applications as quintessential dosimeters are highlighted for future research and improvements.
- 6 February 2019
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2068 (1) , 020047
Determination of Rn-222 emanations from kenaf composite brick
Radon is a natural radioactive gas that is derived from the decomposition of uranium-238 in the soils, rocks, sand and water. This study aimed to investigate whether the replacement of some amounts of raw brick materials (rocks, sand, cement) with treated kenaf fibre can reduce the Rn-222 emanations in fabricated composite bricks. Rn-222 concentrations were measured on four different fabricated bricks in Perspex box using Radon Monitor Sentinel Model 1030. 10 g of treated kenaf fibres were added by different formula of raw materials. Rn-222 concentration reading for each brick was measured within 72 hours consecutively. The results show that the properties of kenaf fibre was influenced the Rn-222 concentrations. The average of Rn-222 concentrations for composite brick 1, 2 and 3 were 1.0 pCi/L, 3.8 pCi/L, 4.1 pCi/L and 3.1 pCi/L, respectively. Composite brick 2 (gravel/kenaf fibre) show the highest average of Rn-222 concentration with 4.1 pCi/L. Meanwhile, concrete brick that act as control shows the lowest average of Rn-222 concentration with 1.0 pCi/L.
- 6 February 2019
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2068 (1) , 020047
Determination of Rn-222 emanations from kenaf composite brick
Radon is a natural radioactive gas that is derived from the decomposition of uranium-238 in the soils, rocks, sand and water. This study aimed to investigate whether the replacement of some amounts of raw brick materials (rocks, sand, cement) with treated kenaf fibre can reduce the Rn-222 emanations in fabricated composite bricks. Rn-222 concentrations were measured on four different fabricated bricks in Perspex box using Radon Monitor Sentinel Model 1030. 10 g of treated kenaf fibres were added by different formula of raw materials. Rn-222 concentration reading for each brick was measured within 72 hours consecutively. The results show that the properties of kenaf fibre was influenced the Rn-222 concentrations. The average of Rn-222 concentrations for composite brick 1, 2 and 3 were 1.0 pCi/L, 3.8 pCi/L, 4.1 pCi/L and 3.1 pCi/L, respectively. Composite brick 2 (gravel/kenaf fibre) show the highest average of Rn-222 concentration with 4.1 pCi/L. Meanwhile, concrete brick that act as control shows the lowest average of Rn-222 concentration with 1.0 pCi/L.
- 1 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 54-58
The Impact of Maximum Turning Angle on Reconstructed Fibre Tractography and Diffusion Tensor Imaging Indices
The impact of turning angle in fibre tractography reconstruction was evaluated. A single subject diffusion tensor imaging (DTI) data were obtained retrospectively. Fibre tractography was performed using commercial software, NordicICE version 2.3.9 (Nordic Neuro Lab, Norway) available at AMDI. During fibre tracking, tract turning angle was varied for 25°, 35°, 45° (default turning angle set by software developer), 55° and 65°. Two major fibre bundles were selected for fibre tractography reconstruction. Then, the assessment was performed on number of fibres reconstructed as well as the MD and FA values of the fibre bundles. The values obtained for each angle were compared with that of obtained using default angle. From the two fibre bundles observed, only results from CST are found showing a conclusive trend of changes. From the CST fibre bundles, it is shown that increasing the tract turning angle increases the number of fibres and MD and decreases the FA values. However, in terms of significance of the changes, both fibre bundles demonstrated that selection of the tract turning angle does not give any significant impact on the fibre tractography reconstruction and DTI indices.
- 1 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 54-58
The Impact of Maximum Turning Angle on Reconstructed Fibre Tractography and Diffusion Tensor Imaging Indices
The impact of turning angle in fibre tractography reconstruction was evaluated. A single subject diffusion tensor imaging (DTI) data were obtained retrospectively. Fibre tractography was performed using commercial software, NordicICE version 2.3.9 (Nordic Neuro Lab, Norway) available at AMDI. During fibre tracking, tract turning angle was varied for 25°, 35°, 45° (default turning angle set by software developer), 55° and 65°. Two major fibre bundles were selected for fibre tractography reconstruction. Then, the assessment was performed on number of fibres reconstructed as well as the MD and FA values of the fibre bundles. The values obtained for each angle were compared with that of obtained using default angle. From the two fibre bundles observed, only results from CST are found showing a conclusive trend of changes. From the CST fibre bundles, it is shown that increasing the tract turning angle increases the number of fibres and MD and decreases the FA values. However, in terms of significance of the changes, both fibre bundles demonstrated that selection of the tract turning angle does not give any significant impact on the fibre tractography reconstruction and DTI indices.