  • Opto-Electromechanical Smart Glasses for Intraocular Pressure Sensing

    by Nergis Saraçbaşı, Parviz Zolfaghari, Arda D. Yalçınkaya, Onur Ferhanoğlu

    We demonstrate smart glasses that integrate a laser diode, a pair of electromagnetically actuated 3D-printed cantilevers, and an endoscopic camera for non-contact intraocular pressure (IOP) monitoring. This sensing device utilizes a fast-scanning cantilever to generate a vertical line on the eye, while a secondary sub-resonant cantilever dynamically steers the beam to remain centered on the pupil despite eye rotation. The IOP is inferred from the corneal deformation, quantified as the radius of curvature of the projected laser line captured by the endoscopic camera. Ray-tracing and finite-element simulations were performed to analyze the optical and mechanical design of the cantilevers. We conducted experiments on an elastic eye phantom at different tilt angles, revealing a pressure resolution of 2.37 mmHg within the 0–50 mmHg range. Compared with grid-projection approach, the dual-actuated design enables precise pupil tracking and consistent curvature estimation. With further in-vivo experimentation and development, the proposed smart-glasses platform could translate into a personalized, real-time continuous IOP monitoring device for glaucoma management.

  • Open Access

    Magnetically Actuated Composite Vocal Fold Phantom for CT/TA Muscle Mimicry

    by Onur Tavli, Kuter Erdil, Alp Kayra Dagistanli, Daghan Gokdel, Onur Ferhanoglu

    We present a magnetically actuated vocal fold–phantom phonation system capable of reproducing longitudinal tension modulation to mimic cricothyroid (CT) and thyroarytenoid (TA) muscle activation. We first formulate the electromagnetic force model and describe howthe resulting artificial muscle activation alters longitudinal stiffness, transverse stiffness, and vibratory behavior. Vocal fold phantoms are fabricated using RTV silicone mixed with Fe powder and cast in 3D-printed molds. Leveraging gravity during curing, Fe powder are concentrated near the transverse surface closest to the actuation coil, enhancing magnetic responsiveness while maintaining tissue-like mechanical properties. Finite-element simulations are used to investigate how longitudinal loading modifies vibratory modes and dynamics. Experimentally, laser Doppler vibrometry (LDV) and knife-edge optical sensing validate the analytical and simulation results. Magnetic actuation enabled longitudinal elongations up to 2.0 mm, providing a tunable phonation frequency range of 127–191 Hz, consistent with simulation. Repeatability testing over 10 hours revealed only ±95 μm standard deviation in elongation, demonstrating the reliability and stability of both the actuator and the phantom. These results establish a tunable, muscle-mimicking platform that can facilitate controlled investigations of tension-dependent phonatory mechanics and support future laryngological research.

  • A tactile sensing capsule endoscope employing force sensing cantilevers for tumor diagnosis in the GI tract

    by Furkan Peker, Ö. Gökalp Akcan, Dila Atak, Ibrahim H. Ozata, Derya S. Uymaz, Emre Balik, Müjdat Zeybel, Hamdi Torun, Onur Ferhanoğlu


  • A MEMS on Fiber Multisensor Platform for Surgical Assistance

    by Morteza Teymoori, Parviz Zolfaghari, Onur Ferhanoğlu, Murat Tümer, Arda Deniz Yalcinkaya

    We developed a microelectromechanical system for simultaneous temperature and pressure measurements, which is integrated on a fiber. The developed platform is integrated at the tip of a fiber optic cable for surgical assistance. The platform comprises a three-layer sealed micrometer-scale membrane that deflects in response to external pressure. Moreover, we exploit the change in bandgap wavelength of the Gallium Arsenide substrate to monitor temperature. The developed multi-sensor is capable of point-wise and decoupled measurements, owing to its compact form factor and different physical principles used for sensing of temperature and pressure. Both sensors are interrogated using a multimode fiber that is butt-coupled to the substrate, allowing for simple integration and alignment as opposed to a singlemode fiber. Furthermore, the exploitation of graded-index in the fiber core enables measurement immunity to fiber bending. Experiments were conducted in a pressure chamber and on ex vivo tissue. We measured sensitivities of 9.04 nm/mmHg in displacement for pressure and –1.38% /°C in optical power for temperature. With further development, the proposed device can be adapted to a clinical setting as a assistive tool during ablative medical operations, in determining ablation boundaries while monitoring intravascular or organ pressure as a vital signal.

  • Laser-induced breakdown spectroscopy for lithium-mediated cancer cell detection and ablation

    by Oğuz Gürcüoğlu, Tuğçe Mutlu, Onur Ferhanoğlu, Mustafa Kemal Ruhi

    Laser-Induced Breakdown Spectroscopy (LIBS) has been explored for biomedical applications, such as distinguishing between cancerous and healthy tissues. Previous studies have demonstrated altered emission intensities of elements such as Ca, Mg, Zn, and Fe in malignant tissues, suggesting that elemental profiling via LIBS could aid in the detection of tumors. However, challenges such as weak signal intensity and interference from biological matrices have hindered the development of a standardized clinical protocol. This study aims to address these limitations by enhancing LIBS signal specificity using lithium chloride (LiCl) as a tumor labeling agent. The cytotoxicity of LiCl was evaluated on PC-3 prostate cancer cells and L929 mouse fibroblast cells. Subsequently, the LIBS-mediated cancer cell detection and ablation method was tested in both phantom and in vitro cancer models. LIBS analysis revealed a significant lithium signal in LiCl-incubated groups in both phantom and in vitro models, and the system successfully identified and ablated the lithium-labeled regions. These findings suggest that LiCl-mediated LIBS may serve as a foundation for developing a compact, dual-purpose platform for cancer detection and ablation during tumor resection surgery. Future studies will focus on miniaturizing and optimizing the system for animal tests and clinical trials, aiming to delineate tumor margins based on LIBS feedback and ablate the tumor cells with precision.


  • Open Access

    A Hybrid Deep Learning and Optical Flow Framework for Monocular Capsule Endoscopy Localization

    by İrem Yakar, Ramazan Alper Kuçak, Serdar Bilgi, Onur Ferhanoglu, Tahir Cetin Akinci

    Pose estimation and localization within the gastrointestinal tract, particularly the small bowel, are crucial for invasive medical procedures. However, the task is challenging due to the complex anatomy, homogeneous textures, and limited distinguishable features. This study proposes a hybrid deep learning (DL) method combining Convolutional Neural Network (CNN)-based pose estimation and optical flow to address these challenges in a simulated small bowel environment. Initial pose estimation was used to assess the performance of simultaneous localization and mapping (SLAM) in such complex settings, using a custom endoscope prototype with a laser, micromotor, and miniaturized camera. The results showed limited feature detection and unreliable matches due to repetitive textures. To improve this issue, a hybrid CNN-based approach enhanced with Farneback optical flow was applied. Using consecutive images, three models were compared: Hybrid ResNet-50 with Farneback optical flow, ResNet-50, and NASNetLarge pretrained on ImageNet. The analysis showed that the hybrid model outperformed both ResNet-50 (0.39 cm) and NASNetLarge (1.46 cm), achieving the lowest RMSE of 0.03 cm, with feature-based SLAM failing to provide reliable results. The hybrid model also gained a competitive inference speed of 241.84 ms per frame, outperforming ResNet-50 (316.57 ms) and NASNetLarge (529.66 ms). To assess the impact of the optical flow choice, Lucas–Kanade was also implemented within the same framework and compared with the Farneback-based results. These results demonstrate that combining optical flow with ResNet-50 enhances pose estimation accuracy and stability, especially in textureless environments where traditional methods struggle. The proposed method offers a robust, real-time alternative to SLAM, with potential applications in clinical capsule endoscopy. The results are positioned as a proof-of-concept that highlights the feasibility and clinical potential of the proposed framework. Future work will extend the framework to real patient data and optimize for real-time hardware.


  • Active distance control in multi-capsule endoscopy via closed loop electromagnetic force between capsules

    by Furkan Peker, Onur Ferhanoğlu

    Capsule endoscopy offers a non-invasive and patient-friendly method for imaging the gastrointestinal tract, boasting superior tissue accessibility compared to traditional endoscopy and colonoscopy. While advances have led to capsules capable of drug delivery, tactile sensing, and biopsy, size constraints often limit a single capsule from having multifunctionality. In response, we introduce multi-capsule endoscopy, where individually ingested capsules, each with unique functionalities, work collaboratively. However, synchronized navigation of these capsules is essential for this approach. In this paper, we present an active distance control strategy using a closed-loop system. This entails equipping one capsule with a sphere permanent magnet and the other with a solenoid. We utilized a Simulink model, incorporating (i) the peristalsis motion on the primary capsule, (ii) a PID controller, (iii) force dynamics between capsules through magnetic dipole approximation, and (iv) position tracking of the secondary capsule. For practical implementation, Hall effect sensors determined the inter-capsule distance, and a PID controller adjusted the solenoid’s current to maintain the desired capsule spacing. Our proof-of-concept experiments, conducted on phantoms and ex vivo bovine tissues, pulled the leading capsule mimicking a typical human peristalsis speed of 1 cm/min. Results showcased an inter-capsule distance of 1.94 mm ± 0.097 mm for radii of curvature at 500 mm, 250 mm, and 100 mm, aiming for a 2-mm capsule spacing. For ex vivo bovine tissue, the achieved distance was 0.97 ± 0.28 mm against a target inter-capsule distance of 1 mm. Through the successful demonstration of precise inter-capsule control, this study paves the way for the potential of multi-capsule endoscopy in future research. Graphical abstract