Carsten Fischer
Research Subjects
Carsten Fischer has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Peter Gehrke
Department for Oral, Cranio-Maxillofacial and Facial Plastic Surgery, Goethe University, University Hospital Frankfurt, Frankfurt am Main, Germany
9 shared publications - Paul Weigl
Department of Postgraduate Education, Center for Dentistry and Oral Medicine (Carolinum), University Hospital, Goethe University Frankfurt, 60596 Frankfurt, Germany
5 shared publications - Robert Sader
University Hospital Frankfurt, Goethe-University Frankfur
3 shared publications - Günter Dhom
Private Practice for Oral Surgery and Implant Dentistry, Ludwigshafen, Germany
2 shared publications - Ralf Smeets
Department of Oral and Maxillofacial Surgery, University Medical Center Hamburg-Eppendorf, 20246 Hamburg, Germany
2 shared publications - Thomas Beikler
Department of Periodontics, Preventive and Restorative Dentistry, University Medical Center Hamburg-Eppendorf, 20246 Hamburg, Germany
2 shared publications
Latest Publications
- Open Access
- 1 January 2024
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 16 (4) , 231-243
Effect of cement type, luting protocol, and ceramic abutment material on the shade of cemented titanium-based lithium disilicate crowns and surrounding peri-implant soft tissue: a spectrophotometric analysis
Gehrke P, et al. J Adv Prosthodont. 2024 Aug;16(4):231-243. https://doi.org/10.4047/jap.2024.16.4.231
- 1 January 2024
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 16 (4) , 231-243
Open AccessEffect of cement type, luting protocol, and ceramic abutment material on the shade of cemented titanium-based lithium disilicate crowns and surrounding peri-implant soft tissue: a spectrophotometric analysis
Gehrke P, et al. J Adv Prosthodont. 2024 Aug;16(4):231-243. https://doi.org/10.4047/jap.2024.16.4.231
- Open Access
- 28 October 2022
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 14 (5) , 273-284
Microbiological cleaning and disinfection efficacy of a three-stage ultrasonic processing protocol for CAD-CAM implant abutments
Gehrke P, et al. J Adv Prosthodont. 2022 Oct;14(5):273-284. https://doi.org/10.4047/jap.2022.14.5.273
- 28 October 2022
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 14 (5) , 273-284
Open AccessMicrobiological cleaning and disinfection efficacy of a three-stage ultrasonic processing protocol for CAD-CAM implant abutments
Gehrke P, et al. J Adv Prosthodont. 2022 Oct;14(5):273-284. https://doi.org/10.4047/jap.2022.14.5.273
- Open Access
- 16 August 2021
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 26 (2) , 1375-1389
Bacterial translocation and microgap formation at a novel conical indexed implant abutment system for single crowns
Objectives: A conometric concept was recently introduced in which conical implant abutments hold the matching crown copings by friction alone, eliminating the need for cement or screws. The aim of this in vitro study was to assess the presence of microgap formation and bacterial leakage at the Acuris conometric restorative interface of three different implant abutment systems. Material and methods: A total of 75 Acuris samples of three implant-abutment systems (Ankylos, Astra Tech EV, Xive) were subjected to microbiological (n = 60) and scanning electron microscopic (SEM) investigation (n = 15). Bacterial migration into and out of the conical coupling system were analyzed in an anaerobic workstation for 48, 96, 144, and 192 h. Bacterial DNA quantification using qrt-PCR was performed at each time point. The precision of the conometric coupling and internal fit of cemented CAD/CAM crowns on corresponding Acuris TiN copings were determined by means of SEM. Results: qrt-PCR results failed to demonstrate microbial leakage from or into the Acuris system. SEM analysis revealed minute punctate microgaps at the apical aspect of the conometric junction (2.04 to 2.64 µm), while mean cement gaps of 12 to 145 µm were observed at the crown-coping interface. Conclusions: The prosthetic morse taper connection of all systems examined does not allow bacterial passage. Marginal integrity and internal luting gap between the ceramic crown and the coping remained within the clinically acceptable limits. Clinical relevance: Conometrically seated single crowns provide sufficient sealing efficiency, relocating potential misfits from the crown-abutment interface to the crown-coping interface.
- 16 August 2021
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 26 (2) , 1375-1389
Open AccessBacterial translocation and microgap formation at a novel conical indexed implant abutment system for single crowns
Objectives: A conometric concept was recently introduced in which conical implant abutments hold the matching crown copings by friction alone, eliminating the need for cement or screws. The aim of this in vitro study was to assess the presence of microgap formation and bacterial leakage at the Acuris conometric restorative interface of three different implant abutment systems. Material and methods: A total of 75 Acuris samples of three implant-abutment systems (Ankylos, Astra Tech EV, Xive) were subjected to microbiological (n = 60) and scanning electron microscopic (SEM) investigation (n = 15). Bacterial migration into and out of the conical coupling system were analyzed in an anaerobic workstation for 48, 96, 144, and 192 h. Bacterial DNA quantification using qrt-PCR was performed at each time point. The precision of the conometric coupling and internal fit of cemented CAD/CAM crowns on corresponding Acuris TiN copings were determined by means of SEM. Results: qrt-PCR results failed to demonstrate microbial leakage from or into the Acuris system. SEM analysis revealed minute punctate microgaps at the apical aspect of the conometric junction (2.04 to 2.64 µm), while mean cement gaps of 12 to 145 µm were observed at the crown-coping interface. Conclusions: The prosthetic morse taper connection of all systems examined does not allow bacterial passage. Marginal integrity and internal luting gap between the ceramic crown and the coping remained within the clinically acceptable limits. Clinical relevance: Conometrically seated single crowns provide sufficient sealing efficiency, relocating potential misfits from the crown-abutment interface to the crown-coping interface.
- 1 July 2021
- Published by Quintessence Publishing in The International Journal of Oral and Maxillofacial Implants
- Vol. 36 (4) , e91-e96
Optical Efficacy of Titanium Nitride–Coated Abutment Material on Soft Tissue Discoloration: A Spectrophotometric In Vitro Analysis
Peter Gehrke, Dr Med Dent/Kai-Peter Zimmermann, Dr Med Dent, MSc/Octavio Weinhold, Dr Med Dent, MSc, MSc/G?nter Dhom, Prof Dr Med Dent/Carsten Fischer, MDT/Robert Sader, Prof Dr Med, Dr Med Dent, Dr Med Habil: Purpose: The objective of this investigation was to assess the extent of mucosal discoloration caused by different CAD/CAM abutment materials and to determine the influence of mucosa thickness on the subsequent color, with a particular focus on titanium nitride. Materials and Methods: In a pig maxilla, a trapdoor-shaped mucosa flap was prepared unilaterally. Several CAD/CAM abutment materials were used to assess a number of clinical scenarios. Varying mucosa thicknesses were simulated by connective tissue grafts harvested at the contralateral side of the palate, resulting in layer thicknesses of 1.5, 2, and 3 mm. Titanium (Ti), zirconia (ZrO2), and titanium nitride (TiN) served as test specimens with and without ceramic veneering. Color differences (ΔE) and deviations in brightness (L), chroma (C), and hue (H) were determined spectrophotometrically, comparing the measured value of the native tissue and the results obtained with different materials at varying mucosa thicknesses. Results: All tested specimens caused a mucosa discoloration in comparison to the native tissue, diminishing with increasing mucosa thickness. The use of TiN demonstrated the least mucosa discoloration in thin soft tissue of 1.5 mm, with a mean ΔE value of 1.93 (P = .004). While ZrO2 revealed a comparable ΔE value of 2.13 (P = .022) at a tissue thickness of 1.5 mm, Ti showed the highest mucosa discoloration above the visibility threshold of ΔE = 3.1, with a mean ΔE value of 4.07 (P = .002). Ceramic veneering of the Ti samples led to a considerable reduction in soft tissue discoloration, with a resulting ΔE value of 2.2. The veneering of TiN and ZrO2 samples with porcelain, on the other hand, had no noticeable effect on the mucosa color. Conclusion: CAD/CAM abutment materials cause an adverse soft tissue color shift that decreases with increasing mucosa thickness. In thin peri-implant mucosa, titanium nitride and zirconia lead to the least discoloration. Due to their positive optical properties and mechanical superiority compared with ceramic abutments, gold-hue titanium nitride?coated CAD/CAM abutments could be a clinical alternative in cases of thin peri-implant mucosa.
- 1 July 2021
- Published by Quintessence Publishing in The International Journal of Oral and Maxillofacial Implants
- Vol. 36 (4) , e91-e96
Optical Efficacy of Titanium Nitride–Coated Abutment Material on Soft Tissue Discoloration: A Spectrophotometric In Vitro Analysis
Peter Gehrke, Dr Med Dent/Kai-Peter Zimmermann, Dr Med Dent, MSc/Octavio Weinhold, Dr Med Dent, MSc, MSc/G?nter Dhom, Prof Dr Med Dent/Carsten Fischer, MDT/Robert Sader, Prof Dr Med, Dr Med Dent, Dr Med Habil: Purpose: The objective of this investigation was to assess the extent of mucosal discoloration caused by different CAD/CAM abutment materials and to determine the influence of mucosa thickness on the subsequent color, with a particular focus on titanium nitride. Materials and Methods: In a pig maxilla, a trapdoor-shaped mucosa flap was prepared unilaterally. Several CAD/CAM abutment materials were used to assess a number of clinical scenarios. Varying mucosa thicknesses were simulated by connective tissue grafts harvested at the contralateral side of the palate, resulting in layer thicknesses of 1.5, 2, and 3 mm. Titanium (Ti), zirconia (ZrO2), and titanium nitride (TiN) served as test specimens with and without ceramic veneering. Color differences (ΔE) and deviations in brightness (L), chroma (C), and hue (H) were determined spectrophotometrically, comparing the measured value of the native tissue and the results obtained with different materials at varying mucosa thicknesses. Results: All tested specimens caused a mucosa discoloration in comparison to the native tissue, diminishing with increasing mucosa thickness. The use of TiN demonstrated the least mucosa discoloration in thin soft tissue of 1.5 mm, with a mean ΔE value of 1.93 (P = .004). While ZrO2 revealed a comparable ΔE value of 2.13 (P = .022) at a tissue thickness of 1.5 mm, Ti showed the highest mucosa discoloration above the visibility threshold of ΔE = 3.1, with a mean ΔE value of 4.07 (P = .002). Ceramic veneering of the Ti samples led to a considerable reduction in soft tissue discoloration, with a resulting ΔE value of 2.2. The veneering of TiN and ZrO2 samples with porcelain, on the other hand, had no noticeable effect on the mucosa color. Conclusion: CAD/CAM abutment materials cause an adverse soft tissue color shift that decreases with increasing mucosa thickness. In thin peri-implant mucosa, titanium nitride and zirconia lead to the least discoloration. Due to their positive optical properties and mechanical superiority compared with ceramic abutments, gold-hue titanium nitride?coated CAD/CAM abutments could be a clinical alternative in cases of thin peri-implant mucosa.
- Open Access
- 17 January 2021
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 22 (2) , 881
Marginal Adaptation and Microbial Leakage at Conometric Prosthetic Connections for Implant-Supported Single Crowns: An In Vitro Investigation
Encouraging clinical results were reported on a novel cone-in-cone coupling for the fixation of dental implant-supported crowns (Acuris, Dentsply Sirona Implants, Mölndal, Sweden). However, the presence or absence of a microgap and a potential bacterial leakage at the conometric joint has not yet been investigated. A misfit and a resulting gap between the conometric components could potentially serve as a bacterial reservoir that promotes plaque formation, which in turn may lead to inflammation of the peri-implant tissues. Thus, a two-fold study set-up was designed in order to evaluate the bidirectional translocation of bacteria along conometrically seated single crowns. On conometric abutments filled with a culture suspension of anaerobic bacteria, the corresponding titanium nitride-coated (TiN) caps were fixed by friction. Each system was sterilized and immersed in culture medium to provide an optimal environment for microbial growth. Positive and negative controls were prepared. Specimens were stored in an anaerobic workstation, and total and viable bacterial counts were determined. Every 48 h, samples were taken from the reaction tubes to inoculate blood agar plates and to isolate bacterial DNA for quantification using qrt-PCR. In addition, one Acuris test system was subjected to scanning electron microscopy (SEM) to evaluate the precision of fit of the conometric coupling and marginal crown opening. Throughout the observational period of one week, blood agar plates of the specimens showed no viable bacterial growth. qrt-PCR, likewise, yielded a result approaching zero with an amount of about 0.53 × 10−4 µg/mL DNA. While the luting gap/marginal opening between the TiN-cap and the ceramic crown was within the clinically acceptable range, the SEM analysis failed to identify a measurable microgap at the cone-in-cone junction. Within the limits of the in-vitro study it can be concluded that the Acuris conometric interface does not allow for bacterial translocation under non-dynamic loading conditions.
- 17 January 2021
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 22 (2) , 881
Open AccessMarginal Adaptation and Microbial Leakage at Conometric Prosthetic Connections for Implant-Supported Single Crowns: An In Vitro Investigation
Encouraging clinical results were reported on a novel cone-in-cone coupling for the fixation of dental implant-supported crowns (Acuris, Dentsply Sirona Implants, Mölndal, Sweden). However, the presence or absence of a microgap and a potential bacterial leakage at the conometric joint has not yet been investigated. A misfit and a resulting gap between the conometric components could potentially serve as a bacterial reservoir that promotes plaque formation, which in turn may lead to inflammation of the peri-implant tissues. Thus, a two-fold study set-up was designed in order to evaluate the bidirectional translocation of bacteria along conometrically seated single crowns. On conometric abutments filled with a culture suspension of anaerobic bacteria, the corresponding titanium nitride-coated (TiN) caps were fixed by friction. Each system was sterilized and immersed in culture medium to provide an optimal environment for microbial growth. Positive and negative controls were prepared. Specimens were stored in an anaerobic workstation, and total and viable bacterial counts were determined. Every 48 h, samples were taken from the reaction tubes to inoculate blood agar plates and to isolate bacterial DNA for quantification using qrt-PCR. In addition, one Acuris test system was subjected to scanning electron microscopy (SEM) to evaluate the precision of fit of the conometric coupling and marginal crown opening. Throughout the observational period of one week, blood agar plates of the specimens showed no viable bacterial growth. qrt-PCR, likewise, yielded a result approaching zero with an amount of about 0.53 × 10−4 µg/mL DNA. While the luting gap/marginal opening between the TiN-cap and the ceramic crown was within the clinically acceptable range, the SEM analysis failed to identify a measurable microgap at the cone-in-cone junction. Within the limits of the in-vitro study it can be concluded that the Acuris conometric interface does not allow for bacterial translocation under non-dynamic loading conditions.
- Open Access
Qualitative and Semi-Quantitative Assessment of Processing-Related Surface Contamination of One- and Two-Piece CAD/CAM Abutments before and after Ultrasonic Cleaning
Manufacturing processes of custom implant abutments may contaminate their surfaces with micro wear deposits and generic pollutants. Such particulate debris, if not removed, might be detrimental and provoke inflammatory reactions in peri-implant tissues. Although regulatory guidelines for adequate cleaning, disinfection, or sterilization exist, there does not appear to be a consistent application and data on the amount and extent of such contaminants is lacking. The aim of the present in vitro study was to evaluate the quality and quantity of processing-related surface contamination of computer-aided design/computer-aided manufacturing (CAD/CAM) abutments in the state of delivery and after ultrasonic cleaning. A total of 28 CAD/CAM monotype and hybrid abutments were cleaned and disinfected applying a three-stage ultrasonic protocol (Finevo protocol). Before and after cleaning, the chemical composition and the contamination of the abutments were assessed using scanning electron microscopy (SEM), dispersive X-ray spectroscopy (EDX), and computer-aided planimetric measurement (CAPM). In the delivery condition, monotype abutments showed a significantly higher amount of debris compared to hybrid abutments (4.86 ± 6.10% vs. 0.03 ± 0.03%, p < 0.001). The polishing process applied in the laboratory after bonding the hybrid abutment components reduces the surface roughness and thus contributes substantially to their purity. The extent of contamination caused by computer-aided manufacturing of custom abutments can be substantially minimized using a three-stage ultrasonic protocol.
Open AccessQualitative and Semi-Quantitative Assessment of Processing-Related Surface Contamination of One- and Two-Piece CAD/CAM Abutments before and after Ultrasonic Cleaning
Manufacturing processes of custom implant abutments may contaminate their surfaces with micro wear deposits and generic pollutants. Such particulate debris, if not removed, might be detrimental and provoke inflammatory reactions in peri-implant tissues. Although regulatory guidelines for adequate cleaning, disinfection, or sterilization exist, there does not appear to be a consistent application and data on the amount and extent of such contaminants is lacking. The aim of the present in vitro study was to evaluate the quality and quantity of processing-related surface contamination of computer-aided design/computer-aided manufacturing (CAD/CAM) abutments in the state of delivery and after ultrasonic cleaning. A total of 28 CAD/CAM monotype and hybrid abutments were cleaned and disinfected applying a three-stage ultrasonic protocol (Finevo protocol). Before and after cleaning, the chemical composition and the contamination of the abutments were assessed using scanning electron microscopy (SEM), dispersive X-ray spectroscopy (EDX), and computer-aided planimetric measurement (CAPM). In the delivery condition, monotype abutments showed a significantly higher amount of debris compared to hybrid abutments (4.86 ± 6.10% vs. 0.03 ± 0.03%, p < 0.001). The polishing process applied in the laboratory after bonding the hybrid abutment components reduces the surface roughness and thus contributes substantially to their purity. The extent of contamination caused by computer-aided manufacturing of custom abutments can be substantially minimized using a three-stage ultrasonic protocol.
- Open Access
- 1 January 2018
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 10 (3) , 197-204
Influence of scaling procedures on the integrity of titanium nitride coated CAD/CAM abutments
Gehrke P, et al. J Adv Prosthodont. 2018 Jun;10(3):197-204. https://doi.org/10.4047/jap.2018.10.3.197
- 1 January 2018
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 10 (3) , 197-204
Open AccessInfluence of scaling procedures on the integrity of titanium nitride coated CAD/CAM abutments
Gehrke P, et al. J Adv Prosthodont. 2018 Jun;10(3):197-204. https://doi.org/10.4047/jap.2018.10.3.197
- Open Access
- 20 September 2017
- Published by MDPI AG in Preprints.org
Comparative Analysis of Surface Topography of Custom CAD/CAM ZirconiaAbutments by means of Optical Profilometry
Objective: CAD/CAM generated ceramic implant abutments have recently attracted interest due to their superior customization possibilities and aesthetic advantages. Despite their widespread clinical use, little information is currently available on their surface topography, however. The transmucosal portion of the abutment shoulder is of particular interest, as it ideally supports soft tissue but minimizes mechanical plaque retention. The aim of this in vitro study was to topographically characterize the trans- and subgingival roughness of CAD/CAM zirconia abutments from different manufacturers and compare them with zirconia stock abutments. Material and Method: The surface topography of eight CAD/CAM zirconia implant abutments (tests) and two prefabricated zirconia stock abutments (controls) was determined using focus variation microscopy. Two points on the abutment shoulder were subjected to profilometric examination. 2D and 3D parameters of roughness were obtained and compared. Results: The surface roughness of all the test abutments exceeded the recommended threshold of Ra = 0.2 µm and therefore exhibited an increased risk of mechanical plaque retention. Obvious differences in surface structure were apparent, allowing conclusions to be drawn about the manufacturing method and subsequent reworking processes. Conclusion: Manually reworking the trans- and submucosal area of the investigated CAD/CAM zirconia abutments appears necessary to fulfil the conditions for optimal surface topography. The Sa value as arithmetic mean, taking the maximum height (Sz value) and surface excess (Sdr) into account, is an essential parameter for assessing the surface topography of implant abutments.
- 20 September 2017
- Published by MDPI AG in Preprints.org
Open AccessComparative Analysis of Surface Topography of Custom CAD/CAM ZirconiaAbutments by means of Optical Profilometry
Objective: CAD/CAM generated ceramic implant abutments have recently attracted interest due to their superior customization possibilities and aesthetic advantages. Despite their widespread clinical use, little information is currently available on their surface topography, however. The transmucosal portion of the abutment shoulder is of particular interest, as it ideally supports soft tissue but minimizes mechanical plaque retention. The aim of this in vitro study was to topographically characterize the trans- and subgingival roughness of CAD/CAM zirconia abutments from different manufacturers and compare them with zirconia stock abutments. Material and Method: The surface topography of eight CAD/CAM zirconia implant abutments (tests) and two prefabricated zirconia stock abutments (controls) was determined using focus variation microscopy. Two points on the abutment shoulder were subjected to profilometric examination. 2D and 3D parameters of roughness were obtained and compared. Results: The surface roughness of all the test abutments exceeded the recommended threshold of Ra = 0.2 µm and therefore exhibited an increased risk of mechanical plaque retention. Obvious differences in surface structure were apparent, allowing conclusions to be drawn about the manufacturing method and subsequent reworking processes. Conclusion: Manually reworking the trans- and submucosal area of the investigated CAD/CAM zirconia abutments appears necessary to fulfil the conditions for optimal surface topography. The Sa value as arithmetic mean, taking the maximum height (Sz value) and surface excess (Sdr) into account, is an essential parameter for assessing the surface topography of implant abutments.
- Open Access
- 1 January 2015
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 7 (2) , 151-159
Microscopical and chemical surface characterization of CAD/CAM zircona abutments after different cleaning procedures. A qualitative analysis
Gehrke P, et al. J Adv Prosthodont. 2015 Apr;7(2):151-159. http://dx.doi.org/10.4047/jap.2015.7.2.151
- 1 January 2015
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 7 (2) , 151-159
Open AccessMicroscopical and chemical surface characterization of CAD/CAM zircona abutments after different cleaning procedures. A qualitative analysis
Gehrke P, et al. J Adv Prosthodont. 2015 Apr;7(2):151-159. http://dx.doi.org/10.4047/jap.2015.7.2.151