Abdul Rehman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Abdul Rehman has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Muhammad Ali Ehsan
Interdisciplinary Research Center for Hydrogen Technologies and Carbon Management (IRC-HTCM), King Fahd University of Petroleum & Minerals, Dhahran, Saudi Arabia
9 shared publications Abbas Saeed Hakeem
Interdisciplinary Research Center for Hydrogen and Energy Storage (IRC-HES), King Fahd University of Petroleum and Minerals, Dhahran 31261, Saudi Arabia
3 shared publications- Abbas Saeed Hakeem
Interdisciplinary Research Center for Hydrogen and Energy Storage, King Fahd University of Petroleum and Minerals, Dhahran, Saudi Arabia
3 shared publications - Adeel Afzal
Sensors and Diagnostics Lab, School of Chemistry, University of the Punjab, Quaid-i-Azam Campus, Lahore 54590, Pakistan
3 shared publications Asghar Ali
Department of Chemistry, College of Science, University of Hafr Al Batin, PO Box 1803, Hafr Al Batin 39524, Saudi Arabia
3 shared publications- Mohammad Qamar
Interdisciplinary Research Center for Hydrogen Technologies and Carbon Management (IRC-HTCM)
3 shared publications
Latest Publications
- 29 September 2021
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 35 (19) , 16054-16064
Highly Effective Electrochemical Water Oxidation by Millerite-Phased Nickel Sulfide Nanoflakes Fabricated on Ni Foam by Aerosol-Assisted Chemical Vapor Deposition
- 29 September 2021
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 35 (19) , 16054-16064
Highly Effective Electrochemical Water Oxidation by Millerite-Phased Nickel Sulfide Nanoflakes Fabricated on Ni Foam by Aerosol-Assisted Chemical Vapor Deposition
- Open Access
- 9 September 2021
- Published by American Chemical Society (ACS)
Development of opto-chemical mercury sensor using fluorescent pyrene-functionalized silica nanoparticles
- 9 September 2021
- Published by American Chemical Society (ACS)
Open AccessDevelopment of opto-chemical mercury sensor using fluorescent pyrene-functionalized silica nanoparticles
- 16 August 2021
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 13 (36) , 4019-4037
Rapid antibody diagnostics for SARS-CoV-2 adaptive immune response
The emergence of a pandemic scale respiratory illness (COVID-19) and the lack of the world's readiness to prevent its spread resulted in an unprecedented rise of biomedical diagnostic industries, as they took lead to provide efficient diagnostic solutions for COVID-19.
- 16 August 2021
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 13 (36) , 4019-4037
Rapid antibody diagnostics for SARS-CoV-2 adaptive immune response
The emergence of a pandemic scale respiratory illness (COVID-19) and the lack of the world's readiness to prevent its spread resulted in an unprecedented rise of biomedical diagnostic industries, as they took lead to provide efficient diagnostic solutions for COVID-19.
- Open Access
- 3 June 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (6) , 1030
Screen-Printed Graphene/Carbon Electrodes on Paper Substrates as Impedance Sensors for Detection of Coronavirus in Nasopharyngeal Fluid Samples
Severe acute respiratory syndrome (SARS-CoV-2), the causative agent of the global pandemic, which has resulted in more than one million deaths with tens of millions reported cases, requires a fast, accurate, and portable testing mechanism operable in the field environment. Electrochemical sensors, based on paper substrates with portable electrochemical devices, can prove an excellent alternative in mitigating the economic and public health effects of the disease. Herein, we present an impedance biosensor for the detection of the SARS-CoV-2 spike protein utilizing the IgG anti-SARS-CoV-2 spike antibody. This label-free platform utilizing screen-printed electrodes works on the principle of redox reaction impedance of a probe and can detect antigen spikes directly in nasopharyngeal fluid as well as virus samples collected in the universal transport medium (UTM). High conductivity graphene/carbon ink is used for this purpose so as to have a small background impedance that leads to a wider dynamic range of detection. Antibody immobilization onto the electrode surface was conducted through a chemical entity or a biological entity to see their effect; where a biological immobilization can enhance the antibody loading and thereby the sensitivity. In both cases, we were able to have a very low limit of quantification (i.e., 0.25 fg/mL), however, the linear range was 3 orders of magnitude wider for the biological entity-based immobilization. The specificity of the sensor was also tested against high concentrations of H1N1 flu antigens with no appreciable response. The most optimized sensors are used to identify negative and positive COVID-19 samples with great accuracy and precision.
- 3 June 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (6) , 1030
Open AccessScreen-Printed Graphene/Carbon Electrodes on Paper Substrates as Impedance Sensors for Detection of Coronavirus in Nasopharyngeal Fluid Samples
Severe acute respiratory syndrome (SARS-CoV-2), the causative agent of the global pandemic, which has resulted in more than one million deaths with tens of millions reported cases, requires a fast, accurate, and portable testing mechanism operable in the field environment. Electrochemical sensors, based on paper substrates with portable electrochemical devices, can prove an excellent alternative in mitigating the economic and public health effects of the disease. Herein, we present an impedance biosensor for the detection of the SARS-CoV-2 spike protein utilizing the IgG anti-SARS-CoV-2 spike antibody. This label-free platform utilizing screen-printed electrodes works on the principle of redox reaction impedance of a probe and can detect antigen spikes directly in nasopharyngeal fluid as well as virus samples collected in the universal transport medium (UTM). High conductivity graphene/carbon ink is used for this purpose so as to have a small background impedance that leads to a wider dynamic range of detection. Antibody immobilization onto the electrode surface was conducted through a chemical entity or a biological entity to see their effect; where a biological immobilization can enhance the antibody loading and thereby the sensitivity. In both cases, we were able to have a very low limit of quantification (i.e., 0.25 fg/mL), however, the linear range was 3 orders of magnitude wider for the biological entity-based immobilization. The specificity of the sensor was also tested against high concentrations of H1N1 flu antigens with no appreciable response. The most optimized sensors are used to identify negative and positive COVID-19 samples with great accuracy and precision.
- 22 March 2021
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 146 (10) , 3317-3327
Aerosol-assisted nanostructuring of nickel/cobalt oxide thin films for viable electrochemical hydrazine sensing
Herein, we report the fabrication of NiO–CoO films for the electrochemical detection of hydrazine. An electrochemical sensor was devised where aerosol assisted chemical vapor deposition (AACVD) was employed as a nifty method for synthesizing NiO–CoO films over FTO electrodes. NiO–CoO-nanoparticle (NP) and NiO–CoO-nanowall (NW) films were fabricated over FTO substrates. The electrocatalytic analysis was performed in a standard three-electrode electrochemical setup. NiO–CoO-NW/FTO showed enhanced electro-oxidation for hydrazine at all concentrations tested. XRD, XPS, EDX, and FE-SEM techniques were used to characterize the structural, morphological, and elemental properties of NiO–CoO films. The results showed improved sensitivity, a large dynamic range, and good long-term stability of NiO–CoO-NW films. The amperometric response was used to measure the detection limit, and it was as low as 0.01 μM, and the sensitivity is ∼33 μA μM−1 cm−2. Besides, the NiO–CoO-NW/FTO electrodes showed significant selectivity towards hydrazine upon testing cross-sensitivity to other common interfering molecules. This strategy of using NiO–CoO-NW/FTO electrodes prepared via AACVD has great potential for the direct determination of hydrazine in environmental sensing applications.
- 22 March 2021
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 146 (10) , 3317-3327
Aerosol-assisted nanostructuring of nickel/cobalt oxide thin films for viable electrochemical hydrazine sensing
Herein, we report the fabrication of NiO–CoO films for the electrochemical detection of hydrazine. An electrochemical sensor was devised where aerosol assisted chemical vapor deposition (AACVD) was employed as a nifty method for synthesizing NiO–CoO films over FTO electrodes. NiO–CoO-nanoparticle (NP) and NiO–CoO-nanowall (NW) films were fabricated over FTO substrates. The electrocatalytic analysis was performed in a standard three-electrode electrochemical setup. NiO–CoO-NW/FTO showed enhanced electro-oxidation for hydrazine at all concentrations tested. XRD, XPS, EDX, and FE-SEM techniques were used to characterize the structural, morphological, and elemental properties of NiO–CoO films. The results showed improved sensitivity, a large dynamic range, and good long-term stability of NiO–CoO-NW films. The amperometric response was used to measure the detection limit, and it was as low as 0.01 μM, and the sensitivity is ∼33 μA μM−1 cm−2. Besides, the NiO–CoO-NW/FTO electrodes showed significant selectivity towards hydrazine upon testing cross-sensitivity to other common interfering molecules. This strategy of using NiO–CoO-NW/FTO electrodes prepared via AACVD has great potential for the direct determination of hydrazine in environmental sensing applications.
- Open Access
Direct Self-Assembly of Hierarchically Grown Rhodium Thin Films for Electrocatalytic Hydrogen Evolution Reaction
Thin films of metallic rhodium (Rh) are developed on two different supports, nickel foam (NF) and titanium foil (Ti), and evaluated for electrochemical hydrogen evolution reaction (HER). The electrodes are prepared by aerosol-assisted chemical vapor deposition technique using a Rh diethyldithiocarabamte precursor for three distinct time periods of 40, 80, and 120 min at 500 °C. The film consists of phase pure metallic Rh with hierarchical flower-like morphology. The structural features of such nanostructures can be modulated by adjusting the growth time. The HER catalytic performance data for the optimized films (i.e., with the deposition time of 80 min) suggest that the Rh deposited on Ti foil (Rh/Ti) catalyze the reaction substantially faster than Rh deposited on Ni foam (Rh/NF). To produce current density of 100 mA cm−2, the Rh/NF needed over potential of 263 mV, while the Rh/Ti electrode required only 175 mV. In spite of lower electrical conductivity, caused by the bare Ti foil, the Rh/Ti electrode exhibits superior HER performance. The Tafel slopes of Rh/NF and Rh/Ti electrodes are determined to be 52 and 42 mV dec−1, while the turnover frequencies are estimated to be 1.1 and 37.3 s−1 at over potential of 260 mV.
Open AccessDirect Self-Assembly of Hierarchically Grown Rhodium Thin Films for Electrocatalytic Hydrogen Evolution Reaction
Thin films of metallic rhodium (Rh) are developed on two different supports, nickel foam (NF) and titanium foil (Ti), and evaluated for electrochemical hydrogen evolution reaction (HER). The electrodes are prepared by aerosol-assisted chemical vapor deposition technique using a Rh diethyldithiocarabamte precursor for three distinct time periods of 40, 80, and 120 min at 500 °C. The film consists of phase pure metallic Rh with hierarchical flower-like morphology. The structural features of such nanostructures can be modulated by adjusting the growth time. The HER catalytic performance data for the optimized films (i.e., with the deposition time of 80 min) suggest that the Rh deposited on Ti foil (Rh/Ti) catalyze the reaction substantially faster than Rh deposited on Ni foam (Rh/NF). To produce current density of 100 mA cm−2, the Rh/NF needed over potential of 263 mV, while the Rh/Ti electrode required only 175 mV. In spite of lower electrical conductivity, caused by the bare Ti foil, the Rh/Ti electrode exhibits superior HER performance. The Tafel slopes of Rh/NF and Rh/Ti electrodes are determined to be 52 and 42 mV dec−1, while the turnover frequencies are estimated to be 1.1 and 37.3 s−1 at over potential of 260 mV.
- 16 November 2020
- Published by Royal Society of Chemistry (RSC) in Sustainable Energy & Fuels
- Vol. 5 (2) , 459-468
Morphologically controlled rapid fabrication of rhodium sulfide (Rh2S3) thin films for superior and robust hydrogen evolution reaction
Rh2S3 thin film electrodes prepared by a facile and rapid fabrication route exhibit superior HER catalysis performance in acidic media.
- 16 November 2020
- Published by Royal Society of Chemistry (RSC) in Sustainable Energy & Fuels
- Vol. 5 (2) , 459-468
Morphologically controlled rapid fabrication of rhodium sulfide (Rh2S3) thin films for superior and robust hydrogen evolution reaction
Rh2S3 thin film electrodes prepared by a facile and rapid fabrication route exhibit superior HER catalysis performance in acidic media.
- Open Access
- 2 September 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-11
Synergistic effects in bimetallic Pd–CoO electrocatalytic thin films for oxygen evolution reaction
Bimetallic catalysts due to the synergistic effects often outperform their single-component counterparts while exhibiting structure and composition-dependent enhancement in active sites, thereby having the potential to improve the current density and over-potential parameters in the water oxidation reaction. Herein, we demonstrate a simple and rapid, yet highly efficient method to fabricate Pd–CoO films of immaculate homogeneity as characterized using different imaging and spectroscopic techniques. The SEM images revealed that the films were composed of bimetallic spherical granules wherein both metals were uniformly distributed in an atomic ratio of ~ 1:1. The time-dependent investigations of the film fabrication behavior demonstrated that the films formed in shorter deposition times (1–2 h) display more porous character, allowing better access to the reaction centers. This character was transcribed into their enhanced electrocatalytic performance toward the oxygen evolution reaction (OER). Using this specific bimetallic formulation, we could attain a low over-potential of 274 mV for a current density of 10 mA cm−2, whereas the high current density value of > 200 mA cm−2was achieved while still under 600 mV of over-potential. The cycling and current generation stability was also found to be sufficiently high, which can only be attributed to the facile electron transfer processes and a higher number of active sites available in homogeneous bimetallic films.
- 2 September 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-11
Open AccessSynergistic effects in bimetallic Pd–CoO electrocatalytic thin films for oxygen evolution reaction
Bimetallic catalysts due to the synergistic effects often outperform their single-component counterparts while exhibiting structure and composition-dependent enhancement in active sites, thereby having the potential to improve the current density and over-potential parameters in the water oxidation reaction. Herein, we demonstrate a simple and rapid, yet highly efficient method to fabricate Pd–CoO films of immaculate homogeneity as characterized using different imaging and spectroscopic techniques. The SEM images revealed that the films were composed of bimetallic spherical granules wherein both metals were uniformly distributed in an atomic ratio of ~ 1:1. The time-dependent investigations of the film fabrication behavior demonstrated that the films formed in shorter deposition times (1–2 h) display more porous character, allowing better access to the reaction centers. This character was transcribed into their enhanced electrocatalytic performance toward the oxygen evolution reaction (OER). Using this specific bimetallic formulation, we could attain a low over-potential of 274 mV for a current density of 10 mA cm−2, whereas the high current density value of > 200 mA cm−2was achieved while still under 600 mV of over-potential. The cycling and current generation stability was also found to be sufficiently high, which can only be attributed to the facile electron transfer processes and a higher number of active sites available in homogeneous bimetallic films.
- 10 July 2020
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 12 (32) , 4028-4036
Facile and scalable fabrication of nanostructured nickel thin film electrodes for electrochemical detection of formaldehyde
Fluorine doped tin oxide (FTO) substrates were deposited with thin metallic nickel films, having distinguishable surface morphologies, via a rapid, facile, and scalable approach i.e., aerosol assisted chemical vapor deposition (AACVD). The growth patterns of the nickel deposits were studied, showing a coalescing behavior as a function of the deposition time in a hierarchical fashion. These studies were followed by electrochemical measurements to design an efficient sensor for formaldehyde detection. The electrochemical responses were correlated with the surface characteristics of the films, whereas the optimized parameters were subjected to the evaluation of sensing performances. The developed sensor demonstrated a detection limit of 8.3 × 10−6 M and a sensitivity of 0.18 A M−1 within a linear range of 0–6.5 mM. Further, the sensor showed a response time of less than 5 s, selectivity against similar concentrations of methanol and formaldehyde, and recovery of ∼102% in a spiked fruit juice sample. Finally, the commercial viability of the fabrication procedure is tested using batch production analysis, and the high reproducibility of the data shows a promising future in mass production. It is envisaged that such low-cost fabrication procedures can be converted into many useful applications in the future.
- 10 July 2020
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 12 (32) , 4028-4036
Facile and scalable fabrication of nanostructured nickel thin film electrodes for electrochemical detection of formaldehyde
Fluorine doped tin oxide (FTO) substrates were deposited with thin metallic nickel films, having distinguishable surface morphologies, via a rapid, facile, and scalable approach i.e., aerosol assisted chemical vapor deposition (AACVD). The growth patterns of the nickel deposits were studied, showing a coalescing behavior as a function of the deposition time in a hierarchical fashion. These studies were followed by electrochemical measurements to design an efficient sensor for formaldehyde detection. The electrochemical responses were correlated with the surface characteristics of the films, whereas the optimized parameters were subjected to the evaluation of sensing performances. The developed sensor demonstrated a detection limit of 8.3 × 10−6 M and a sensitivity of 0.18 A M−1 within a linear range of 0–6.5 mM. Further, the sensor showed a response time of less than 5 s, selectivity against similar concentrations of methanol and formaldehyde, and recovery of ∼102% in a spiked fruit juice sample. Finally, the commercial viability of the fabrication procedure is tested using batch production analysis, and the high reproducibility of the data shows a promising future in mass production. It is envisaged that such low-cost fabrication procedures can be converted into many useful applications in the future.