Luzhen Nie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Luzhen Nie has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
- Steven Freear
University of Leeds
18 shared publications David M. J. Cowell
School of Electronic and Electrical Engineering University of Leeds Leeds, LS2 9JT UK
8 shared publicationsSteven Freear
School of Electronic and Electrical Engineering, University of Leeds, Leeds, UK
8 shared publications- James Ross McLaughlan
School of Electronic & Electrical Engineering, University of Leeds, LS2 9JT, UK
6 shared publications - Stefano Laureti
Department of Informatics, Modeling, Electronics and System Engineering, University of Calabria, Rende, Italy
6 shared publications David A. Hutchins
School of Engineering University of Warwick Coventry, CV4 7AL UK
5 shared publications
Latest Publications
- Open Access
- 21 August 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 123 (8)
A human ear-inspired ultrasonic transducer (HEUT) for 3D localization of sub-wavelength scatterers
The proposed technology aims to enable 3D localization of scatterers using single element ultrasonic transducers, which are traditionally limited to 1D measurements. This is achieved by designing a bespoke acoustic lens with a spiral-shaped pattern similar to the human outer ear, a shape that has evolved for sound source localization. This lens breaks the surface symmetry of the transducer, allowing ultrasonic waves arriving from different directions to be encoded in a certain way that can later be decoded to extract directional information. By employing the mechanism of spatial-encoding of the received signals and decoding via signal processing, the location of sub-wavelength scatterers can be detected in 3D with a single measurement for sparsely distributed scatterers. The proposed technology is first verified through a simulation study, and then 3D printed acoustic lenses are used to demonstrate the 3D encoding functionality of the Human Ear-inspired Ultrasonic Transducer (HEUT) experimentally. A framework is created to localize scatterers in 3D by processing received signals acquired by a HEUT prototype. With this technology, a single transducer can obtain multi-dimensional information with a single pulse-echo measurement, reducing the number of elements required for performing 3D ultrasound localization. The proposed spatial-encoding and -decoding technology can be applied to other wave-based imaging methods to develop affordable, practical, and compact sensing devices.
- 21 August 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 123 (8)
Open AccessA human ear-inspired ultrasonic transducer (HEUT) for 3D localization of sub-wavelength scatterers
The proposed technology aims to enable 3D localization of scatterers using single element ultrasonic transducers, which are traditionally limited to 1D measurements. This is achieved by designing a bespoke acoustic lens with a spiral-shaped pattern similar to the human outer ear, a shape that has evolved for sound source localization. This lens breaks the surface symmetry of the transducer, allowing ultrasonic waves arriving from different directions to be encoded in a certain way that can later be decoded to extract directional information. By employing the mechanism of spatial-encoding of the received signals and decoding via signal processing, the location of sub-wavelength scatterers can be detected in 3D with a single measurement for sparsely distributed scatterers. The proposed technology is first verified through a simulation study, and then 3D printed acoustic lenses are used to demonstrate the 3D encoding functionality of the Human Ear-inspired Ultrasonic Transducer (HEUT) experimentally. A framework is created to localize scatterers in 3D by processing received signals acquired by a HEUT prototype. With this technology, a single transducer can obtain multi-dimensional information with a single pulse-echo measurement, reducing the number of elements required for performing 3D ultrasound localization. The proposed spatial-encoding and -decoding technology can be applied to other wave-based imaging methods to develop affordable, practical, and compact sensing devices.
- Open Access
- 18 March 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (6) , 1161
Enhancement of Ultrasound B-Mode Image Quality Using Nonlinear Filtered-Multiply-and-Sum Compounding for Improved Carotid Artery Segmentation
In ultrasound B-mode imaging, the axial resolution (AR) is commonly determined by the duration or bandwidth of an excitation signal. A shorter-duration pulse will produce better resolution compared to a longer one but with compromised penetration depth. Instead of relying on the pulse duration or bandwidth to improve the AR, an alternative method termed filtered multiply and sum (FMAS) has been introduced in our previous work. For spatial-compounding, FMAS uses the autocorrelation technique as used in filtered-delay multiply and sum (FDMAS), instead of conventional averaging. FMAS enables a higher frame rate and less computational complexity than conventional plane-wave compound imaging beamformed with delay and sum (DAS) and FDMAS. Moreover, it can provide an improved contrast ratio and AR. In previous work, no explanation was given on how FMAS was able to improve the AR. Thus, in this work, we discuss in detail the theory behind the proposed FMAS algorithm and how it is able to improve the spatial resolution mainly in the axial direction. Simulations, experimental phantom measurements and in vivo studies were conducted to benchmark the performance of the proposed method. We also demonstrate how the suggested new algorithm may be used in a practical biomedical imaging application. The balloon snake active contour segmentation technique was applied to the ultrasound B-mode image of a common carotid artery produced with FMAS. The suggested method is capable of reducing the number of iterations for the snake to settle on the region-of-interest contour, accelerating the segmentation process.
- 18 March 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (6) , 1161
Open AccessEnhancement of Ultrasound B-Mode Image Quality Using Nonlinear Filtered-Multiply-and-Sum Compounding for Improved Carotid Artery Segmentation
In ultrasound B-mode imaging, the axial resolution (AR) is commonly determined by the duration or bandwidth of an excitation signal. A shorter-duration pulse will produce better resolution compared to a longer one but with compromised penetration depth. Instead of relying on the pulse duration or bandwidth to improve the AR, an alternative method termed filtered multiply and sum (FMAS) has been introduced in our previous work. For spatial-compounding, FMAS uses the autocorrelation technique as used in filtered-delay multiply and sum (FDMAS), instead of conventional averaging. FMAS enables a higher frame rate and less computational complexity than conventional plane-wave compound imaging beamformed with delay and sum (DAS) and FDMAS. Moreover, it can provide an improved contrast ratio and AR. In previous work, no explanation was given on how FMAS was able to improve the AR. Thus, in this work, we discuss in detail the theory behind the proposed FMAS algorithm and how it is able to improve the spatial resolution mainly in the axial direction. Simulations, experimental phantom measurements and in vivo studies were conducted to benchmark the performance of the proposed method. We also demonstrate how the suggested new algorithm may be used in a practical biomedical imaging application. The balloon snake active contour segmentation technique was applied to the ultrasound B-mode image of a common carotid artery produced with FMAS. The suggested method is capable of reducing the number of iterations for the snake to settle on the region-of-interest contour, accelerating the segmentation process.
- Open Access
- 10 February 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (4) , 1818
An Open Access Chamber Designed for the Acoustic Characterisation of Microbubbles
Microbubbles are used as contrast agents in clinical ultrasound for Left Ventricular Opacification (LVO) and perfusion imaging. They are also the subject of promising research in therapeutics as a drug delivery mechanism or for sonoporation and co-administration. For maximum efficacy in these applications, it is important to understand the acoustic characteristics of the administered microbubbles. Despite this, there is significant variation in the experimental procedures and equipment used to measure the acoustic properties of microbubble populations. A chamber was designed to facilitate acoustic characterisation experiments and was manufactured using additive manufacturing techniques. The design has been released to allow wider uptake in the research community. The efficacy of the chamber for acoustic characterisation has been explored with an experiment to measure the scattering of SonoVue® microbubbles at the fundamental frequency and second harmonic under interrogation from emissions in the frequency range of 1.6 to 6.4 MHz. The highest overall scattering values were measured at 1.6 MHz and decreased as the frequency increased, a result which is in agreement with previously published measurements. Statistical analysis of the acoustic scattering measurements have been performed and a significant difference, at the 5% significance level, was found between the samples containing contrast agent and the control sample containing only deionised water. These findings validate the proposed design for measuring the acoustic scattering characteristics of ultrasound contrast agents.
- 10 February 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (4) , 1818
Open AccessAn Open Access Chamber Designed for the Acoustic Characterisation of Microbubbles
Microbubbles are used as contrast agents in clinical ultrasound for Left Ventricular Opacification (LVO) and perfusion imaging. They are also the subject of promising research in therapeutics as a drug delivery mechanism or for sonoporation and co-administration. For maximum efficacy in these applications, it is important to understand the acoustic characteristics of the administered microbubbles. Despite this, there is significant variation in the experimental procedures and equipment used to measure the acoustic properties of microbubble populations. A chamber was designed to facilitate acoustic characterisation experiments and was manufactured using additive manufacturing techniques. The design has been released to allow wider uptake in the research community. The efficacy of the chamber for acoustic characterisation has been explored with an experiment to measure the scattering of SonoVue® microbubbles at the fundamental frequency and second harmonic under interrogation from emissions in the frequency range of 1.6 to 6.4 MHz. The highest overall scattering values were measured at 1.6 MHz and decreased as the frequency increased, a result which is in agreement with previously published measurements. Statistical analysis of the acoustic scattering measurements have been performed and a significant difference, at the 5% significance level, was found between the samples containing contrast agent and the control sample containing only deionised water. These findings validate the proposed design for measuring the acoustic scattering characteristics of ultrasound contrast agents.
- Open Access
- 1 December 2021
- Published by Wiley in Advanced Engineering Materials
- Vol. 24 (4)
A Metallic Additively Manufactured Metamaterial for Enhanced Monitoring of Acoustic Cavitation‐Based Therapeutic Ultrasound
The combination of ultrasound and microbubbles allows treatment of indications that would be impossible or too risk adverse with conventional surgery. During treatment, subharmonic and ultraharmonic components that can only be generated from microbubbles are of great interest for intraoperative monitoring. However, the microbubble emissions are several orders of magnitude lower in power compared to that of the fundamental frequency component from the ultrasound applicator, resulting in a low signal‐to‐noise ratio (SNR) for monitoring. A 3D acoustic metamaterial (AMM) immersed in water is proposed for suppressing unwanted ultrasound waves, which allows the improved sensitivity for detecting weak microbubble emissions. Numerically, the importance of shear waves on the AMM transfer properties is highlighted, though only longitudinal ultrasound waves are transmitted through water. Experimentally, the design is implemented in titanium using additive manufacturing, with an attenuation level of 40 dB at the fundamental frequency. Consequently, the application of the AMM efficiently improves the SNR for subharmonic and ultraharmonic microbubble emissions by 11.8 and 11.9 dB, respectively. The subharmonic components originally overwhelmed by noise are recovered. This is the first time that AMMs have been applied to passive acoustic monitoring and this work stands to improve treatment outcomes from cavitation‐mediated focused ultrasound therapy.
- 1 December 2021
- Published by Wiley in Advanced Engineering Materials
- Vol. 24 (4)
Open AccessA Metallic Additively Manufactured Metamaterial for Enhanced Monitoring of Acoustic Cavitation‐Based Therapeutic Ultrasound
The combination of ultrasound and microbubbles allows treatment of indications that would be impossible or too risk adverse with conventional surgery. During treatment, subharmonic and ultraharmonic components that can only be generated from microbubbles are of great interest for intraoperative monitoring. However, the microbubble emissions are several orders of magnitude lower in power compared to that of the fundamental frequency component from the ultrasound applicator, resulting in a low signal‐to‐noise ratio (SNR) for monitoring. A 3D acoustic metamaterial (AMM) immersed in water is proposed for suppressing unwanted ultrasound waves, which allows the improved sensitivity for detecting weak microbubble emissions. Numerically, the importance of shear waves on the AMM transfer properties is highlighted, though only longitudinal ultrasound waves are transmitted through water. Experimentally, the design is implemented in titanium using additive manufacturing, with an attenuation level of 40 dB at the fundamental frequency. Consequently, the application of the AMM efficiently improves the SNR for subharmonic and ultraharmonic microbubble emissions by 11.8 and 11.9 dB, respectively. The subharmonic components originally overwhelmed by noise are recovered. This is the first time that AMMs have been applied to passive acoustic monitoring and this work stands to improve treatment outcomes from cavitation‐mediated focused ultrasound therapy.
- Open Access
- 1 February 2021
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1070 (1) , 012095
Selection of Excitation Signals and Acoustic Pressure Measurement for In-Vivo Studies with Ultrasound Array Research Platform II
In recent years, the Ultrasound Group at the University of Leeds has developed an open platform (OP) known as Ultrasound Array Research Platform II (UARPII). The OP serves as a main component for researchers to test and implement new algorithms which is not feasible with the commercially available clinical scanners. In this paper, three types of excitation signals, the square pulse, 2-cycle sinusoid and linear frequency modulated chirps which are commonly employed in ultrasound imaging, were investigated for in-vivo experiments with the UARP II OP. The USA food and drug administration (FDA) provides strict guidelines that need to be followed when working with in-vivo medium. This is to ensure that the acoustic beam intensities do not cause any types of thermal damage and cavitation. The acoustic pressures produced by those excitation signals were measured with a needle hydrophone. The main three parameters of the excitation signals measured and calculated are the mechanical index (MI), spatial peak pulse average intensity (SPPA) and spatial peak temporal average intensity (SPTA). By considering advantages and disadvantages of all investigated excitation signals, the 2-cycle sinusoidal signal has been selected for all simulations and experiments with the in-vivo medium.
- 1 February 2021
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1070 (1) , 012095
Open AccessSelection of Excitation Signals and Acoustic Pressure Measurement for In-Vivo Studies with Ultrasound Array Research Platform II
In recent years, the Ultrasound Group at the University of Leeds has developed an open platform (OP) known as Ultrasound Array Research Platform II (UARPII). The OP serves as a main component for researchers to test and implement new algorithms which is not feasible with the commercially available clinical scanners. In this paper, three types of excitation signals, the square pulse, 2-cycle sinusoid and linear frequency modulated chirps which are commonly employed in ultrasound imaging, were investigated for in-vivo experiments with the UARP II OP. The USA food and drug administration (FDA) provides strict guidelines that need to be followed when working with in-vivo medium. This is to ensure that the acoustic beam intensities do not cause any types of thermal damage and cavitation. The acoustic pressures produced by those excitation signals were measured with a needle hydrophone. The main three parameters of the excitation signals measured and calculated are the mechanical index (MI), spatial peak pulse average intensity (SPPA) and spatial peak temporal average intensity (SPTA). By considering advantages and disadvantages of all investigated excitation signals, the 2-cycle sinusoidal signal has been selected for all simulations and experiments with the in-vivo medium.
- 1 December 2020
- Published by Elsevier in Additive Manufacturing
- Vol. 36
Additive manufacturing of metamaterials: A review
- 1 December 2020
- Published by Elsevier in Additive Manufacturing
- Vol. 36
Additive manufacturing of metamaterials: A review
- Open Access
- 1 November 2020
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 46 (11) , 2875-2890
Contrast-Enhanced High-Frame-Rate Ultrasound Imaging of Flow Patterns in Cardiac Chambers and Deep Vessels
- 1 November 2020
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 46 (11) , 2875-2890
Open AccessContrast-Enhanced High-Frame-Rate Ultrasound Imaging of Flow Patterns in Cardiac Chambers and Deep Vessels
- Open Access
- 1 October 2020
- Published by Elsevier in Additive Manufacturing
- Vol. 35
An ultrasonic metallic Fabry–Pérot metamaterial for use in water
- 1 October 2020
- Published by Elsevier in Additive Manufacturing
- Vol. 35
Open AccessAn ultrasonic metallic Fabry–Pérot metamaterial for use in water
- Open Access
- 30 June 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-12
Trapped air metamaterial concept for ultrasonic sub-wavelength imaging in water
Acoustic metamaterials constructed from conventional base materials can exhibit exotic phenomena not commonly found in nature, achieved by combining geometrical and resonance effects. However, the use of polymer-based metamaterials that could operate in water is difficult, due to the low acoustic impedance mismatch between water and polymers. Here we introduce the concept of “trapped air” metamaterial, fabricated via vat photopolymerization, which makes ultrasonic sub-wavelength imaging in water using polymeric metamaterials highly effective. This concept is demonstrated for a holey-structured acoustic metamaterial in water at 200–300 kHz, via both finite element modelling and experimental measurements, but it can be extended to other types of metamaterials. The new approach, which outperforms the usual designs of these structures, indicates a way forward for exploiting additive-manufacturing for realising polymer-based acoustic metamaterials in water at ultrasonic frequencies.
- 30 June 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-12
Open AccessTrapped air metamaterial concept for ultrasonic sub-wavelength imaging in water
Acoustic metamaterials constructed from conventional base materials can exhibit exotic phenomena not commonly found in nature, achieved by combining geometrical and resonance effects. However, the use of polymer-based metamaterials that could operate in water is difficult, due to the low acoustic impedance mismatch between water and polymers. Here we introduce the concept of “trapped air” metamaterial, fabricated via vat photopolymerization, which makes ultrasonic sub-wavelength imaging in water using polymeric metamaterials highly effective. This concept is demonstrated for a holey-structured acoustic metamaterial in water at 200–300 kHz, via both finite element modelling and experimental measurements, but it can be extended to other types of metamaterials. The new approach, which outperforms the usual designs of these structures, indicates a way forward for exploiting additive-manufacturing for realising polymer-based acoustic metamaterials in water at ultrasonic frequencies.
- Open Access
Trapped air metamaterials for ultrasonic sub-wavelength imaging in water
Acoustic metamaterials constructed from conventional base materials can exhibit exotic phenomena such as negative refractive index, extraordinary transmission-absorption and sub-wavelength imaging. These are typically achieved by combining geometrical and resonance effects. Holey-structured acoustic metamaterials have already shown potential for sub-wavelength acoustic imaging in air, where it is relatively simple to achieve the required difference in acoustic impedance needed to create resonances within the holes. However, the use of polymers for metamaterial operation in water is difficult, due to the much lower difference in acoustic impedance between water and the many polymers used, for example, in additive manufacturing. Hence, metals are commonly used. Here we show that this can be overcome by trapping air layers so that they surround each water-filled channel, making sub-wavelength imaging in water possible. The operation of such a Trapped air design is confirmed at 200-300 kHz ultrasonic frequencies via both finite element modelling and experimental measurements in a water tank. It is also shown quantitatively that the trapped air design outperforms its metal counterpart. The results indicate a way forward for exploiting additive-manufacturing for realising acoustic metamaterials in water at ultrasonic frequencies.
Open AccessTrapped air metamaterials for ultrasonic sub-wavelength imaging in water
Acoustic metamaterials constructed from conventional base materials can exhibit exotic phenomena such as negative refractive index, extraordinary transmission-absorption and sub-wavelength imaging. These are typically achieved by combining geometrical and resonance effects. Holey-structured acoustic metamaterials have already shown potential for sub-wavelength acoustic imaging in air, where it is relatively simple to achieve the required difference in acoustic impedance needed to create resonances within the holes. However, the use of polymers for metamaterial operation in water is difficult, due to the much lower difference in acoustic impedance between water and the many polymers used, for example, in additive manufacturing. Hence, metals are commonly used. Here we show that this can be overcome by trapping air layers so that they surround each water-filled channel, making sub-wavelength imaging in water possible. The operation of such a Trapped air design is confirmed at 200-300 kHz ultrasonic frequencies via both finite element modelling and experimental measurements in a water tank. It is also shown quantitatively that the trapped air design outperforms its metal counterpart. The results indicate a way forward for exploiting additive-manufacturing for realising acoustic metamaterials in water at ultrasonic frequencies.