Ahmed M. Ballo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ahmed M. Ballo has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Peter Thomsen
Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
2 shared publications A. Palmquist
Department of Biomaterials, Institute for Clinical Sciences, Sahlgrenska Academy at University of Gothenburg, Gothenburg, Sweden; BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy, Gothenburg, Sweden
1 shared publicationAbdullah Al-Dosari
Department of Prosthetic Dental Science, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
1 shared publicationCaroline T. Nguyen
Department of Oral Health Sciences, Faculty of Dentistry, University of British Columbia, Vancouver, Canada
1 shared publication- Eralp Akca
Department of Periodontology, Dental Sciences Center, Gulhane Military Medical Academy, Ankara, Turkey
1 shared publication Fahad Alshehri
Department of Periodontics and Community Dentistry, King Saud University, Riyadh, Saudi Arabia
1 shared publication
Latest Publications
- 26 April 2021
- Published by Wiley in Journal of Prosthodontics
- Vol. 30 (7) , 632-635
A Novel Digital Implant Planning Workflow in Patients with Preexisting Metal Restorations: A Technical Report
A prosthetic‐driven virtual implant plan is considered a challenging procedure depending on accurate registration of the three‐dimensional optical surface scan and 3D volumetric rendering reconstructed from cone‐beam computed tomography (CBCT) images. However, the presence of pre‐existing metal restorations may significantly negatively influence the registration process. This technical report describes a novel digital workflow to optimize the implant planning outcome for the partially edentulous patient with pre‐existing metal restorations by accurately aligning the standard triangle language data of the intraoral scanner with the CBCT rendering using a dual‐scan technique and an appliance with radiographic markers. This article is protected by copyright. All rights reserved
- 26 April 2021
- Published by Wiley in Journal of Prosthodontics
- Vol. 30 (7) , 632-635
A Novel Digital Implant Planning Workflow in Patients with Preexisting Metal Restorations: A Technical Report
A prosthetic‐driven virtual implant plan is considered a challenging procedure depending on accurate registration of the three‐dimensional optical surface scan and 3D volumetric rendering reconstructed from cone‐beam computed tomography (CBCT) images. However, the presence of pre‐existing metal restorations may significantly negatively influence the registration process. This technical report describes a novel digital workflow to optimize the implant planning outcome for the partially edentulous patient with pre‐existing metal restorations by accurately aligning the standard triangle language data of the intraoral scanner with the CBCT rendering using a dual‐scan technique and an appliance with radiographic markers. This article is protected by copyright. All rights reserved
- 18 March 2019
- Published by Wiley in Journal of Prosthodontics
- Vol. 28 (5) , 596-600
Digital Workflow of Auricular Rehabilitation: A Technical Report Using an Intraoral Scanner
Prosthodontic rehabilitation of a congenital or acquired defect of the ear is considered a challenging and skill‐dependent procedure. This technical report describes a novel approach for direct digital scanning of the unaffected contralateral ear using an intraoral scanner and external markers. The obtained digital data of the ear was exported, digitally mirrored, and successfully positioned to a virtual model of a human head with a missing ear. This technique demonstrates the potential application of CAD/CAM in the design and fabrication of an auricular prosthesis for patients with a unilateral ear defect.
- 18 March 2019
- Published by Wiley in Journal of Prosthodontics
- Vol. 28 (5) , 596-600
Digital Workflow of Auricular Rehabilitation: A Technical Report Using an Intraoral Scanner
Prosthodontic rehabilitation of a congenital or acquired defect of the ear is considered a challenging and skill‐dependent procedure. This technical report describes a novel approach for direct digital scanning of the unaffected contralateral ear using an intraoral scanner and external markers. The obtained digital data of the ear was exported, digitally mirrored, and successfully positioned to a virtual model of a human head with a missing ear. This technique demonstrates the potential application of CAD/CAM in the design and fabrication of an auricular prosthesis for patients with a unilateral ear defect.
- Open Access
- 1 January 2016
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 8 (5) , 345-353
Esthetic outcome for maxillary anterior single implants assessed by different dental specialists
Al-Dosari A, et al. J Adv Prosthodont. 2016 Oct;8(5):345-353. https://doi.org/10.4047/jap.2016.8.5.345
- 1 January 2016
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 8 (5) , 345-353
Open AccessEsthetic outcome for maxillary anterior single implants assessed by different dental specialists
Al-Dosari A, et al. J Adv Prosthodont. 2016 Oct;8(5):345-353. https://doi.org/10.4047/jap.2016.8.5.345
- 1 January 2015
- Published by ROPOSTURO Romanian Association of Oral Rehabilitation and Posturotherapy in STOMATOLOGY EDU JOURNAL
- Vol. 2 (1) , 84
Implant Dentistry Research Guide: Basic, Translational and Clinical Research
- 1 January 2015
- Published by ROPOSTURO Romanian Association of Oral Rehabilitation and Posturotherapy in STOMATOLOGY EDU JOURNAL
- Vol. 2 (1) , 84
Implant Dentistry Research Guide: Basic, Translational and Clinical Research
- 1 December 2014
- Published by Elsevier in Dental Materials
- Vol. 30 (12) , e384-e395
Osseointegration of fiber-reinforced composite implants: Histological and ultrastructural observations
- 1 December 2014
- Published by Elsevier in Dental Materials
- Vol. 30 (12) , e384-e395
Osseointegration of fiber-reinforced composite implants: Histological and ultrastructural observations
- 27 May 2014
- Published by Wiley in European Journal of Oral Sciences
- Vol. 122 (4) , 303-309
Effect of implant design and bioactive glass coating on biomechanical properties of fiber‐reinforced composite implants
This study aimed to evaluate the influence of implant design and bioactive glass (BAG) coating on the response of bone to fiber-reinforced composite (FRC) implants. Three different FRC implant types were manufactured for the study: non-threaded implants with a BAG coating; threaded implants with a BAG coating; and threaded implants with a grit-blasted surface. Thirty-six implants (six implants for each group per time point) were installed in the tibiae of six pigs. After an implantation period of 4 and 12 wk, the implants were retrieved and prepared for micro-computed tomography (micro-CT), push-out testing, and scanning electron microscopy analysis. Micro-CT demonstrated that the screw-threads and implant structure remained undamaged during the installation. The threaded FRC/BAG implants had the highest bone volume after 12 wk of implantation. The push-out strengths of the threaded FRC/BAG implants after 4 and 12 wk (463°N and 676°N, respectively) were significantly higher than those of the threaded FRC implants (416°N and 549°N, respectively) and the nonthreaded FRC/BAG implants (219°N and 430°N, respectively). Statistically significant correlation was found between bone volume and push-out strength values. This study showed that osseointegrated FRC implants can withstand the static loading up to failure without fracture, and that the addition of BAG significantly improves the push-out strength of FRC implants.
- 27 May 2014
- Published by Wiley in European Journal of Oral Sciences
- Vol. 122 (4) , 303-309
Effect of implant design and bioactive glass coating on biomechanical properties of fiber‐reinforced composite implants
This study aimed to evaluate the influence of implant design and bioactive glass (BAG) coating on the response of bone to fiber-reinforced composite (FRC) implants. Three different FRC implant types were manufactured for the study: non-threaded implants with a BAG coating; threaded implants with a BAG coating; and threaded implants with a grit-blasted surface. Thirty-six implants (six implants for each group per time point) were installed in the tibiae of six pigs. After an implantation period of 4 and 12 wk, the implants were retrieved and prepared for micro-computed tomography (micro-CT), push-out testing, and scanning electron microscopy analysis. Micro-CT demonstrated that the screw-threads and implant structure remained undamaged during the installation. The threaded FRC/BAG implants had the highest bone volume after 12 wk of implantation. The push-out strengths of the threaded FRC/BAG implants after 4 and 12 wk (463°N and 676°N, respectively) were significantly higher than those of the threaded FRC implants (416°N and 549°N, respectively) and the nonthreaded FRC/BAG implants (219°N and 430°N, respectively). Statistically significant correlation was found between bone volume and push-out strength values. This study showed that osseointegrated FRC implants can withstand the static loading up to failure without fracture, and that the addition of BAG significantly improves the push-out strength of FRC implants.
- Open Access
- 1 December 2011
- Published by Taylor & Francis in International Journal of Nanomedicine
- Vol. 6, 3415-3428
Nanostructured model implants for in vivo studies: influence of well-defined nanotopography on de novo bone formation on titanium implants
An implantable model system was developed to investigate the effects of nanoscale surface properties on the osseointegration of titanium implants in rat tibia. Topographical nanostructures with a well-defined shape (semispherical protrusions) and variable size (60 nm, 120 nm and 220 nm) were produced by colloidal lithography on the machined implants. Furthermore, the implants were sputter-coated with titanium to ensure a uniform surface chemical composition. The histological evaluation of bone around the implants at 7 days and 28 days after implantation was performed on the ground sections using optical and scanning electron microscopy. Differences between groups were found mainly in the new bone formation process in the endosteal and marrow bone compartments after 28 days of implantation. Implant surfaces with 60 nm features demonstrated significantly higher bone-implant contact (BIC, 76%) compared with the 120 nm (45%) and control (57%) surfaces. This effect was correlated to the higher density and curvature of the 60 nm protrusions. Within the developed model system, nanoscale protrusions could be applied and systematically varied in size in the presence of microscale background roughness on complex screw-shaped implants. Moreover, the model can be adapted for the systematic variation of surface nanofeature density and chemistry, which opens up new possibilities for in vivo studies of various nanoscale surface-bone interactions.
- 1 December 2011
- Published by Taylor & Francis in International Journal of Nanomedicine
- Vol. 6, 3415-3428
Open AccessNanostructured model implants for in vivo studies: influence of well-defined nanotopography on de novo bone formation on titanium implants
An implantable model system was developed to investigate the effects of nanoscale surface properties on the osseointegration of titanium implants in rat tibia. Topographical nanostructures with a well-defined shape (semispherical protrusions) and variable size (60 nm, 120 nm and 220 nm) were produced by colloidal lithography on the machined implants. Furthermore, the implants were sputter-coated with titanium to ensure a uniform surface chemical composition. The histological evaluation of bone around the implants at 7 days and 28 days after implantation was performed on the ground sections using optical and scanning electron microscopy. Differences between groups were found mainly in the new bone formation process in the endosteal and marrow bone compartments after 28 days of implantation. Implant surfaces with 60 nm features demonstrated significantly higher bone-implant contact (BIC, 76%) compared with the 120 nm (45%) and control (57%) surfaces. This effect was correlated to the higher density and curvature of the 60 nm protrusions. Within the developed model system, nanoscale protrusions could be applied and systematically varied in size in the presence of microscale background roughness on complex screw-shaped implants. Moreover, the model can be adapted for the systematic variation of surface nanofeature density and chemistry, which opens up new possibilities for in vivo studies of various nanoscale surface-bone interactions.