Misugi Urano
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Misugi Urano has a total of 102 co-authors. Here are the top co-authors by number of shared publications:
Yuta Shibamoto
10 shared publicationsTatsuya Toyama
Department of Breast Surgery, Nagoya City University Graduate School of Medical Sciences, Japan
6 shared publicationsNorio Shiraki
Department of Radiology, Nagoya City West Medical Center
5 shared publicationsTatsuya Kawai
5 shared publications- Akio Hiwatashi
Department of Radiology, Nagoya City University Graduate School of Medical Sciences , 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, Aichi 467-8601
3 shared publications Kengo Ohta
Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, Aichi 467-0001, Japan
3 shared publications
Latest Publications
- Open Access
- 25 August 2026
- Published by Elsevier in Radiology Case Reports
- Vol. 21 (11) , 5538-5543
Photon-counting detector CT vs energy-integrating detector CT for the diagnosis of arterial dissection in the cervicocerebral region: A single-center case series
- 25 August 2026
- Published by Elsevier in Radiology Case Reports
- Vol. 21 (11) , 5538-5543
Open AccessPhoton-counting detector CT vs energy-integrating detector CT for the diagnosis of arterial dissection in the cervicocerebral region: A single-center case series
- Open Access
- 21 January 2025
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 36 (5) , 869-876
Robot-Assisted CT-Guided Biopsy with an Artificial Intelligence–Based Needle-Path Generator: An Experimental Evaluation Using a Phantom Model
- 21 January 2025
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 36 (5) , 869-876
Open AccessRobot-Assisted CT-Guided Biopsy with an Artificial Intelligence–Based Needle-Path Generator: An Experimental Evaluation Using a Phantom Model
- Open Access
- 10 August 2024
- Published by Elsevier in Radiology Case Reports
- Vol. 19 (11) , 4721-4724
Giant-cell arteritis on photon-counting detector CT: A case report
- 10 August 2024
- Published by Elsevier in Radiology Case Reports
- Vol. 19 (11) , 4721-4724
Open AccessGiant-cell arteritis on photon-counting detector CT: A case report
- Open Access
- 15 June 2024
- Published by Elsevier in Radiology Case Reports
- Vol. 19 (9) , 3618-3621
Photon-counting detector CT with an ultra-low-dose contrast media to diagnose a renal pseudoaneurysm: A case report
- 15 June 2024
- Published by Elsevier in Radiology Case Reports
- Vol. 19 (9) , 3618-3621
Open AccessPhoton-counting detector CT with an ultra-low-dose contrast media to diagnose a renal pseudoaneurysm: A case report
- 11 May 2023
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 103, 179-184
Three-compartment spectral diffusion analysis for breast cancer magnetic resonance imaging
- 11 May 2023
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 103, 179-184
Three-compartment spectral diffusion analysis for breast cancer magnetic resonance imaging
- Open Access
- 1 November 2020
- Published by Elsevier in Radiology Case Reports
- Vol. 15 (11) , 2494
Corrigendum to “Relapsed multiple myeloma manifesting as extramedullary plasmacytoma of the breast: Imaging findings” [Radiology Case Reports 14 (2019) 584–587]
- 1 November 2020
- Published by Elsevier in Radiology Case Reports
- Vol. 15 (11) , 2494
Open AccessCorrigendum to “Relapsed multiple myeloma manifesting as extramedullary plasmacytoma of the breast: Imaging findings” [Radiology Case Reports 14 (2019) 584–587]
- 10 September 2020
- Published by Springer Nature in Breast Cancer Research and Treatment
- Vol. 184 (3) , 817-823
Utility of 70-kV single-energy CT in depicting the extent of breast cancer for preoperative planning
Purpose To evaluate the detectability of breast cancer and visibility of the tumor extent using 70-kV single-energy contrast-enhanced (CE) breast computed tomography (70-kV CECT) compared with CE breast magnetic resonance imaging (CEMR). Methods Between 2013 and 2015, 110 patients with 112 breast cancer lesions who underwent breast surgery after undergoing both 70-kV CECT and CEMR were enrolled. The major axis lengths of the breast lesion were measured and compared with the pathologically determined major axes. Agreement in the measured major axes was evaluated using the intra-class correlation coefficient (ICC). Results Both 70-kV CECT and CEMR depicted all breast cancer lesions. The mean major axis was 3.0 (95% confidence interval [CI], 2.5–3.4) cm on CECT and 2.9 (2.6–3.3) cm on CEMR. The mean differences between the pathologically and radiologically measured major axes on 70-kV CECT and CEMR were 0.9 (0.7–1.1) and 1.0 (0.8–1.2) cm, respectively. The accuracy of the radiological major axes compared with the pathological major axes was 82.1% and 80.4% on CECT and CEMR, respectively (p = 0.81). The major axes on the two modalities demonstrated moderate agreement (ICC = 0.69, 95% CI 0.58–0.77). Pathologically and radiologically measured major axes on 70-kV CECT and CEMR demonstrated excellent agreement (ICC = 0.91, 95% CI 0.93–0.96). Conclusions Low-tube voltage (70-kV) CECT is the preferred modality to identify breast cancer lesions and tumor extent for preoperative planning because it has a similar diagnostic ability to CEMR and can be performed in the supine position.
- 10 September 2020
- Published by Springer Nature in Breast Cancer Research and Treatment
- Vol. 184 (3) , 817-823
Utility of 70-kV single-energy CT in depicting the extent of breast cancer for preoperative planning
Purpose To evaluate the detectability of breast cancer and visibility of the tumor extent using 70-kV single-energy contrast-enhanced (CE) breast computed tomography (70-kV CECT) compared with CE breast magnetic resonance imaging (CEMR). Methods Between 2013 and 2015, 110 patients with 112 breast cancer lesions who underwent breast surgery after undergoing both 70-kV CECT and CEMR were enrolled. The major axis lengths of the breast lesion were measured and compared with the pathologically determined major axes. Agreement in the measured major axes was evaluated using the intra-class correlation coefficient (ICC). Results Both 70-kV CECT and CEMR depicted all breast cancer lesions. The mean major axis was 3.0 (95% confidence interval [CI], 2.5–3.4) cm on CECT and 2.9 (2.6–3.3) cm on CEMR. The mean differences between the pathologically and radiologically measured major axes on 70-kV CECT and CEMR were 0.9 (0.7–1.1) and 1.0 (0.8–1.2) cm, respectively. The accuracy of the radiological major axes compared with the pathological major axes was 82.1% and 80.4% on CECT and CEMR, respectively (p = 0.81). The major axes on the two modalities demonstrated moderate agreement (ICC = 0.69, 95% CI 0.58–0.77). Pathologically and radiologically measured major axes on 70-kV CECT and CEMR demonstrated excellent agreement (ICC = 0.91, 95% CI 0.93–0.96). Conclusions Low-tube voltage (70-kV) CECT is the preferred modality to identify breast cancer lesions and tumor extent for preoperative planning because it has a similar diagnostic ability to CEMR and can be performed in the supine position.
- Open Access
- 1 May 2019
- Published by Elsevier in Radiology Case Reports
- Vol. 14 (5) , 584-587
Relapsed multiple myeloma manifesting as extramedullary plasmacytoma of the breast: Imaging findings
- 1 May 2019
- Published by Elsevier in Radiology Case Reports
- Vol. 14 (5) , 584-587
Open AccessRelapsed multiple myeloma manifesting as extramedullary plasmacytoma of the breast: Imaging findings
- 31 December 2018
- Published by Kurume Medical Journal in The Kurume Medical Journal
- Vol. 65 (4) , 113-121
Digital Mammographic Features of Breast Cancer Recurrences and Benign Lesions Mimicking Malignancy Following Breast-Conserving Surgery and Radiation Therapy.
Mammography after breast-conserving surgery and radiation therapy is an important tool for followup. Early diagnosis of local recurrence enables prompt treatment decisions, which may affect patient prognosis. For complicated post-treatment changes, radiologists sometimes have difficulties in interpreting follow-up mammography. Fat necrosis, dystrophic calcifications, suture calcification features, breast edema, seroma and distorted breast are benign changes related to treatment. These findings may mimic or hide tumor recurrence making it difficult to diagnose recurrences or prevent inappropriate biopsies. Recurrent tumors in follow-up mammography show several typical findings such as increasing asymmetric density, enlarging mass, reappearance of breast edema, and micro-calcifications. The purpose of this pictorial review is to demonstrate and discuss mammographic findings of recurrent tumors and important post-treatment changes that may mimic benign or malignant lesions, also using breast ultrasound images or breast magnetic resonance images. Recognizing post-treatment changes may help radiologists to more effectively identify candidates for suspected local recurrences.
- 31 December 2018
- Published by Kurume Medical Journal in The Kurume Medical Journal
- Vol. 65 (4) , 113-121
Digital Mammographic Features of Breast Cancer Recurrences and Benign Lesions Mimicking Malignancy Following Breast-Conserving Surgery and Radiation Therapy.
Mammography after breast-conserving surgery and radiation therapy is an important tool for followup. Early diagnosis of local recurrence enables prompt treatment decisions, which may affect patient prognosis. For complicated post-treatment changes, radiologists sometimes have difficulties in interpreting follow-up mammography. Fat necrosis, dystrophic calcifications, suture calcification features, breast edema, seroma and distorted breast are benign changes related to treatment. These findings may mimic or hide tumor recurrence making it difficult to diagnose recurrences or prevent inappropriate biopsies. Recurrent tumors in follow-up mammography show several typical findings such as increasing asymmetric density, enlarging mass, reappearance of breast edema, and micro-calcifications. The purpose of this pictorial review is to demonstrate and discuss mammographic findings of recurrent tumors and important post-treatment changes that may mimic benign or malignant lesions, also using breast ultrasound images or breast magnetic resonance images. Recognizing post-treatment changes may help radiologists to more effectively identify candidates for suspected local recurrences.