Roland Friedl
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Roland Friedl has a total of 127 co-authors. Here are the top co-authors by number of shared publications:
- Ursel Fantz
Max-Planck-Institut für Plasmaphysik
33 shared publications - Adrian Heiler
Max-Planck-Institut für Plasmaphysik, Garching, Germany
7 shared publications - Dirk Wunderlich
Max-Planck-Institut für Plasmaphysik
5 shared publications - Stefan Briefi
Max Planck Inst Plasma Phys, Boltzmannstr 2, D-85748 Garching, Germany
5 shared publications - Sofia Cristofaro
Max-Planck-Institut für Plasmaphysik, Boltzmannstr. 2, 85748 Garching, Germany
4 shared publications C. Hopf
3 shared publications
Latest Publications
- Open Access
- 1 May 2026
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3237 (1)
The high-energy tail of the EEDF and its impact on H − volume ion sources
Primary electrons emitted from the cathode of arc discharge plasmas used for production of negative hydrogen ions give rise to a high-energy electron ensemble of the resulting EEDF. The impact of this high-energy tail on the process chain towards negative ion formation via dissociative electron attachment is quantified by modeling. Collisional-radiative and balance models for the solver Yacora are applied using a Maxwellian EEDF, a simulated EEDF for a filament source as well as anticipated EEDFs for a variation of the arc voltage. The high energy tail (and its variations) are found to affect the vibrational population of H 2 , and with that the H − density, by a factor of 1.1–3. Measurements on the D-Pace filament source show an increasing beam current by 27% for increasing filament voltage, possibly indicating an actual impact on the EEDF; this however needs to be confirmed by further investigations using appropriate plasma diagnostics.
- 1 May 2026
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3237 (1)
Open AccessThe high-energy tail of the EEDF and its impact on H − volume ion sources
Primary electrons emitted from the cathode of arc discharge plasmas used for production of negative hydrogen ions give rise to a high-energy electron ensemble of the resulting EEDF. The impact of this high-energy tail on the process chain towards negative ion formation via dissociative electron attachment is quantified by modeling. Collisional-radiative and balance models for the solver Yacora are applied using a Maxwellian EEDF, a simulated EEDF for a filament source as well as anticipated EEDFs for a variation of the arc voltage. The high energy tail (and its variations) are found to affect the vibrational population of H 2 , and with that the H − density, by a factor of 1.1–3. Measurements on the D-Pace filament source show an increasing beam current by 27% for increasing filament voltage, possibly indicating an actual impact on the EEDF; this however needs to be confirmed by further investigations using appropriate plasma diagnostics.
- Open Access
- 27 June 2025
- Published by Elsevier in Fusion Engineering and Design
- Vol. 219
Achieving high amplifications in a cw-driven optical cavity relevant for photoneutralization of negative ion beams
- 27 June 2025
- Published by Elsevier in Fusion Engineering and Design
- Vol. 219
Open AccessAchieving high amplifications in a cw-driven optical cavity relevant for photoneutralization of negative ion beams
- Open Access
- 21 March 2025
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 43 (3)
Generation of ultra-low work function surfaces by caesium and water coadsorption in view of negative hydrogen ion sources
The surface production of negative hydrogen ions requires low work function (WF) converter surfaces, for which caesium adsorption is typically used. Since caesium is highly reactive and easily forms caesium compounds, the resulting WF is strongly influenced by the vacuum conditions, ranging from about 10−8 to 10−6 mbar in present-day negative hydrogen ion sources for accelerators and fusion. As water is usually the main residual gas, dedicated investigations on the WF evolution upon caesium and water coadsorption are performed. The investigations are conducted in an ultra-high vacuum chamber (base pressure of ∼10−10 mbar), where a polycrystalline molybdenum surface is caesiated and water is admitted by using a variable leak valve. Up to a water pressure of 10−9 mbar, the typical WF minimum curve is measured: The WF decreases to 1.5±0.1 eV in the submonolayer regime and increases to 1.8±0.1 eV for longer caesiation times. For water pressures ≳10−8 mbar, the WF decreases to below 1.5 eV for a sufficient caesium flux onto the surface, indicating the formation of caesium oxides. The WF stabilizes at 1.2±0.1 eV and is in agreement with measurements performed in a high vacuum chamber (base pressure of 10−6−10−5 mbar), where it is shown that the ultra-low WF is achieved for a caesium to water flux ratio of ≳5×10−3 onto the surface. Heating the substrate to temperatures above 200°C leads to caesium desorption from the surface and to a WF increase of the ultra-low WF layer. The results impressively demonstrate that the base pressure and applied surface temperature are decisive parameters for the development of negative hydrogen ion sources.
- 21 March 2025
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 43 (3)
Open AccessGeneration of ultra-low work function surfaces by caesium and water coadsorption in view of negative hydrogen ion sources
The surface production of negative hydrogen ions requires low work function (WF) converter surfaces, for which caesium adsorption is typically used. Since caesium is highly reactive and easily forms caesium compounds, the resulting WF is strongly influenced by the vacuum conditions, ranging from about 10−8 to 10−6 mbar in present-day negative hydrogen ion sources for accelerators and fusion. As water is usually the main residual gas, dedicated investigations on the WF evolution upon caesium and water coadsorption are performed. The investigations are conducted in an ultra-high vacuum chamber (base pressure of ∼10−10 mbar), where a polycrystalline molybdenum surface is caesiated and water is admitted by using a variable leak valve. Up to a water pressure of 10−9 mbar, the typical WF minimum curve is measured: The WF decreases to 1.5±0.1 eV in the submonolayer regime and increases to 1.8±0.1 eV for longer caesiation times. For water pressures ≳10−8 mbar, the WF decreases to below 1.5 eV for a sufficient caesium flux onto the surface, indicating the formation of caesium oxides. The WF stabilizes at 1.2±0.1 eV and is in agreement with measurements performed in a high vacuum chamber (base pressure of 10−6−10−5 mbar), where it is shown that the ultra-low WF is achieved for a caesium to water flux ratio of ≳5×10−3 onto the surface. Heating the substrate to temperatures above 200°C leads to caesium desorption from the surface and to a WF increase of the ultra-low WF layer. The results impressively demonstrate that the base pressure and applied surface temperature are decisive parameters for the development of negative hydrogen ion sources.
- Open Access
- 2 December 2024
- Published by Springer Nature in Plasma Chemistry and Plasma Processing
- Vol. 45 (1) , 1-20
Separation of Plasma Species for Investigating the Impact of Hydrogen Plasmas on the Work Function of Caesiated Surfaces
In negative hydrogen ion sources in situ adsorption of Cs is typically used to generate low work function converter surfaces. The achievement of a temporally stable low work function coating is, however, challenging due to the hydrogen plasma interaction with the surface. Particularly in ion sources for neutral beam injection systems for fusion with pulse durations of minutes to hours temporal instabilities are a major issue and limit the source performance. To clarify the influence of the hydrogen plasma on the converter surface, investigations are performed at an experiment equipped with an absolute work function diagnostic based on the photoelectric effect. Caesiated surfaces are exposed to the full plasma impact by the generation of plasmas in front of the surface as well as to selected plasma species (H atoms, positive ions and VUV/UV photons) from an external plasma source to identify driving mechanisms that lead to surface changes. Depending on the exposure time and initial surface condition, the plasma strongly affects the surface in terms of work function and quantum efficiency (QE). For degraded Cs layers (work function $$\ge 3$$ eV) a favorable increase in QE and reduction in work function can be achieved, while for Cs layers with an ultra-low work function of $$1.2-1.3$$ eV the opposite is true. It is found that each plasma species can influence the Cs layers and that VUV photons lead to a work function increase of ultra-low work function layers. For sufficiently high VUV fluences a severe work function increase by 0.5 eV is given, highlighting the relevance of photochemical processes in the plasma-surface interaction and demonstrating that ultra-low work function layers are not stable in a hydrogen plasma environment.- 2 December 2024
- Published by Springer Nature in Plasma Chemistry and Plasma Processing
- Vol. 45 (1) , 1-20
Open AccessSeparation of Plasma Species for Investigating the Impact of Hydrogen Plasmas on the Work Function of Caesiated Surfaces
In negative hydrogen ion sources in situ adsorption of Cs is typically used to generate low work function converter surfaces. The achievement of a temporally stable low work function coating is, however, challenging due to the hydrogen plasma interaction with the surface. Particularly in ion sources for neutral beam injection systems for fusion with pulse durations of minutes to hours temporal instabilities are a major issue and limit the source performance. To clarify the influence of the hydrogen plasma on the converter surface, investigations are performed at an experiment equipped with an absolute work function diagnostic based on the photoelectric effect. Caesiated surfaces are exposed to the full plasma impact by the generation of plasmas in front of the surface as well as to selected plasma species (H atoms, positive ions and VUV/UV photons) from an external plasma source to identify driving mechanisms that lead to surface changes. Depending on the exposure time and initial surface condition, the plasma strongly affects the surface in terms of work function and quantum efficiency (QE). For degraded Cs layers (work function $$\ge 3$$ eV) a favorable increase in QE and reduction in work function can be achieved, while for Cs layers with an ultra-low work function of $$1.2-1.3$$ eV the opposite is true. It is found that each plasma species can influence the Cs layers and that VUV photons lead to a work function increase of ultra-low work function layers. For sufficiently high VUV fluences a severe work function increase by 0.5 eV is given, highlighting the relevance of photochemical processes in the plasma-surface interaction and demonstrating that ultra-low work function layers are not stable in a hydrogen plasma environment. - Open Access
- 1 January 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (01) , C01057
Ultra-low work function of caesiated surfaces and impact of selected gas species
Modern high-power negative hydrogen ion sources rely predominantly on the surface production of negative hydrogen ions. Hence, low work function converter surfaces are mandatory, for which the alkali metal Cs is commonly evaporated into the ion source to lower the work function of refractory metals by surface adsorption. To study the work function behaviour upon caesiation under the typically given non-ultra-high vacuum conditions, investigations are performed at a dedicated laboratory experiment. In a vacuum environment dominated by water vapour, the work function evolution is found to be dependent on the flux ratio of Cs to H2O onto the surface. For sufficiently high flux ratios, ultra-low work functions in the range of 1.25±0.10 eV are generated with excellent reproducibility. In the absence of Cs evaporation, the work function gradually increases under the influence of the residual gases, and re-caesiation processes lead to lower quantum efficiencies and higher work functions of typically 1.9–2.1 eV. While the addition of hydrogen and deuterium gas at several Pa as well as the leakage of inert gases (argon and nitrogen) into the vacuum system have a negligible influence on the caesiation process, small amounts of oxygen with partial pressures of ∼10-2–10-1 Pa lead to an instant reduction of the Cs density in the gas phase by several orders of magnitude and to an increase in the work function of the order of 1 eV. After the oxygen exposure is terminated, however, the Cs density and work function fully recover within several minutes.
- 1 January 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (01) , C01057
Open AccessUltra-low work function of caesiated surfaces and impact of selected gas species
Modern high-power negative hydrogen ion sources rely predominantly on the surface production of negative hydrogen ions. Hence, low work function converter surfaces are mandatory, for which the alkali metal Cs is commonly evaporated into the ion source to lower the work function of refractory metals by surface adsorption. To study the work function behaviour upon caesiation under the typically given non-ultra-high vacuum conditions, investigations are performed at a dedicated laboratory experiment. In a vacuum environment dominated by water vapour, the work function evolution is found to be dependent on the flux ratio of Cs to H2O onto the surface. For sufficiently high flux ratios, ultra-low work functions in the range of 1.25±0.10 eV are generated with excellent reproducibility. In the absence of Cs evaporation, the work function gradually increases under the influence of the residual gases, and re-caesiation processes lead to lower quantum efficiencies and higher work functions of typically 1.9–2.1 eV. While the addition of hydrogen and deuterium gas at several Pa as well as the leakage of inert gases (argon and nitrogen) into the vacuum system have a negligible influence on the caesiation process, small amounts of oxygen with partial pressures of ∼10-2–10-1 Pa lead to an instant reduction of the Cs density in the gas phase by several orders of magnitude and to an increase in the work function of the order of 1 eV. After the oxygen exposure is terminated, however, the Cs density and work function fully recover within several minutes.
- 16 February 2023
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (5) , 055501
A portable diagnostic system for the quantification of VUV fluxes emitted from low-temperature plasmas
Vacuum-ultraviolet (VUV) spectroscopy is linked to a huge effort, in particular if absolute numbers are required. To overcome this, a flexible device is developed based on a photodiode and optical filters for wavelength selection. Characterization of the diagnostic is performed against a VUV spectrometer that is radiometrically calibrated down to 46 nm. In the first instance, the latter is used for an analysis of VUV spectra of inductively coupled low-temperature plasmas for a variety of discharge gases and mixtures. The measured photon fluxes can easily have comparable magnitude as the occurring ion flux, and it is demonstrated that the photonic energy distribution can change drastically with varying external parameters (pressure, RF power). This highlights the need for energy resolution for VUV flux detection and a set of ten optical filters was selected for the VUV diode system according to the respective prominent emission ranges of typical discharge gases for plasma processing. Recommended filter combinations for each of the discharge gases and mixtures are given. The developed diagnostic is calibrated in-house against the VUV spectrometer, which makes energy-resolved absolute VUV flux measurements up to photon energies of 27 eV possible. The calibration is performed individually for all the investigated discharge gases and the corresponding filter combinations, and an accuracy of better than 25% compared to the VUV spectrometer is attested for the investigated parameter space (0.3–10 Pa, 200–1100 W RF power). Its applicability is demonstrated by measuring VUV fluxes at two further low-temperature plasma setups.
- 16 February 2023
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (5) , 055501
A portable diagnostic system for the quantification of VUV fluxes emitted from low-temperature plasmas
Vacuum-ultraviolet (VUV) spectroscopy is linked to a huge effort, in particular if absolute numbers are required. To overcome this, a flexible device is developed based on a photodiode and optical filters for wavelength selection. Characterization of the diagnostic is performed against a VUV spectrometer that is radiometrically calibrated down to 46 nm. In the first instance, the latter is used for an analysis of VUV spectra of inductively coupled low-temperature plasmas for a variety of discharge gases and mixtures. The measured photon fluxes can easily have comparable magnitude as the occurring ion flux, and it is demonstrated that the photonic energy distribution can change drastically with varying external parameters (pressure, RF power). This highlights the need for energy resolution for VUV flux detection and a set of ten optical filters was selected for the VUV diode system according to the respective prominent emission ranges of typical discharge gases for plasma processing. Recommended filter combinations for each of the discharge gases and mixtures are given. The developed diagnostic is calibrated in-house against the VUV spectrometer, which makes energy-resolved absolute VUV flux measurements up to photon energies of 27 eV possible. The calibration is performed individually for all the investigated discharge gases and the corresponding filter combinations, and an accuracy of better than 25% compared to the VUV spectrometer is attested for the investigated parameter space (0.3–10 Pa, 200–1100 W RF power). Its applicability is demonstrated by measuring VUV fluxes at two further low-temperature plasma setups.
- Top Cited PapersOpen Access
- 23 May 2022
- Published by Elsevier in Fusion Engineering and Design
- Vol. 180
Status and future development of Heating and Current Drive for the EU DEMO
- 23 May 2022
- Published by Elsevier in Fusion Engineering and Design
- Vol. 180
Top Cited PapersOpen AccessStatus and future development of Heating and Current Drive for the EU DEMO
- Open Access
- 1 March 2022
- Published by AIP Publishing in AIP Advances
- Vol. 12 (3) , 035339
Impact of the photoelectric threshold sensitivity on the work function determination—Revealing ultra-low work functions of caesiated surfaces
The exploitation of the photoelectric effect is a prominent method for the in situ measurement of the absolute work function of a surface. In the case of metallic surfaces, the Fowler theory is routinely applied for fitting or extrapolating the measured photoelectric yield data to determine the work function value. However, for the reliable application of the Fowler method, attention must be paid to the experimental sensitivity to the photoelectric behavior close to the threshold, which is mainly determined by the signal-to-noise ratio for photocurrent detection and the available photon energies used for irradiation. This is illustrated by means of applying a photoelectric work function measurement system during a Cs coating process of a metal surface, where insufficiently low photon energies or an unfavorable noise level can lead to a severe overestimation of the work function of the order of 1 eV. By a sufficient enhancement of the photoelectric sensitivity, it is now unveiled that ultra-low surface work functions of 1.25 ± 0.10 eV can be generated via caesiation of metallic surfaces (here molybdenum and stainless steel) under vacuum conditions of 10−6–10−5 mbar, which is most probably the result of the formation of an oxidized Cs adlayer.
- 1 March 2022
- Published by AIP Publishing in AIP Advances
- Vol. 12 (3) , 035339
Open AccessImpact of the photoelectric threshold sensitivity on the work function determination—Revealing ultra-low work functions of caesiated surfaces
The exploitation of the photoelectric effect is a prominent method for the in situ measurement of the absolute work function of a surface. In the case of metallic surfaces, the Fowler theory is routinely applied for fitting or extrapolating the measured photoelectric yield data to determine the work function value. However, for the reliable application of the Fowler method, attention must be paid to the experimental sensitivity to the photoelectric behavior close to the threshold, which is mainly determined by the signal-to-noise ratio for photocurrent detection and the available photon energies used for irradiation. This is illustrated by means of applying a photoelectric work function measurement system during a Cs coating process of a metal surface, where insufficiently low photon energies or an unfavorable noise level can lead to a severe overestimation of the work function of the order of 1 eV. By a sufficient enhancement of the photoelectric sensitivity, it is now unveiled that ultra-low surface work functions of 1.25 ± 0.10 eV can be generated via caesiation of metallic surfaces (here molybdenum and stainless steel) under vacuum conditions of 10−6–10−5 mbar, which is most probably the result of the formation of an oxidized Cs adlayer.
- Open Access
- 1 December 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (12) , 123510
Emission spectroscopy of negative hydrogen ion sources: From VUV to IR
The target parameters of negative ion sources regarding the current of extracted negative ions, the current of co-extracted electrons, the pulse duration, the duty cycle, and the availability of the system can be rather strict. Knowledge of plasma parameters such as the electron temperature and the electron density and also properties of molecules or photon fluxes can provide essential insights into the ion source physics needed for reaching the target parameters. Emission spectroscopy is a non-invasive tool enabling access to line-of-sight averaged values of plasma parameters. This paper gives an overview of the application of emission spectroscopy in the visible range, extended for long wavelengths to the near-IR and for short wavelengths to the vacuum ultraviolet (VUV)/UV range. The amount of information to be gained from measured emission spectra is directly correlated with the effort invested for calibrating the system. Examples are given, ranging from simple monitoring to the complex evaluation of molecular spectra and the determination of highly energetic photon fluxes in the VUV/UV range. Additional emphasis is laid on the population models needed for the interpretation of measured spectra.
- 1 December 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (12) , 123510
Open AccessEmission spectroscopy of negative hydrogen ion sources: From VUV to IR
The target parameters of negative ion sources regarding the current of extracted negative ions, the current of co-extracted electrons, the pulse duration, the duty cycle, and the availability of the system can be rather strict. Knowledge of plasma parameters such as the electron temperature and the electron density and also properties of molecules or photon fluxes can provide essential insights into the ion source physics needed for reaching the target parameters. Emission spectroscopy is a non-invasive tool enabling access to line-of-sight averaged values of plasma parameters. This paper gives an overview of the application of emission spectroscopy in the visible range, extended for long wavelengths to the near-IR and for short wavelengths to the vacuum ultraviolet (VUV)/UV range. The amount of information to be gained from measured emission spectra is directly correlated with the effort invested for calibrating the system. Examples are given, ranging from simple monitoring to the complex evaluation of molecular spectra and the determination of highly energetic photon fluxes in the VUV/UV range. Additional emphasis is laid on the population models needed for the interpretation of measured spectra.
- Open Access
- 1 June 2021
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 30 (6) , 065013
The role of photon self-absorption on the H (n = 2) density determination by means of VUV emission spectroscopy and TDLAS in low pressure plasmas
The H (n = 2) atomic density determination by means of vacuum ultra-violet (VUV) emission spectroscopy of the Lyman-α line in laboratory low pressure plasmas is strongly affected by self-absorption of emitted photons inside the plasma leading to an underestimation of this density. A correction of the densities obtained from VUV emission spectroscopy measurements is performed by using the escape factor method. The corrections applied can reach orders of magnitude even in low pressure plasmas. Assumptions on the spatial distribution of emitting and absorbing particles as well as on the corresponding line profiles have to be made. Consequently, additional measurements are performed, which raises the requirement of a benchmark of the applied correction procedure. In contrast, tunable diode laser absorption spectroscopy (TDLAS) on the Balmer-α line is a direct measurement of the H (n = 2) density and is thus suitable for a benchmark. For the ICP under consideration, H (n = 2) densities obtained via TDLAS are near 3 × 1015 m−3 whereas uncorrected VUV emission spectroscopy gives values in the range of roughly 1013 m−3 depending on pressure and applied RF power. The calculated escape factors are on the order of 2–8 × 10−3. An excellent agreement with TDLAS is observed by applying them to the results of the VUV emission spectroscopy.
- 1 June 2021
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 30 (6) , 065013
Open AccessThe role of photon self-absorption on the H (n = 2) density determination by means of VUV emission spectroscopy and TDLAS in low pressure plasmas
The H (n = 2) atomic density determination by means of vacuum ultra-violet (VUV) emission spectroscopy of the Lyman-α line in laboratory low pressure plasmas is strongly affected by self-absorption of emitted photons inside the plasma leading to an underestimation of this density. A correction of the densities obtained from VUV emission spectroscopy measurements is performed by using the escape factor method. The corrections applied can reach orders of magnitude even in low pressure plasmas. Assumptions on the spatial distribution of emitting and absorbing particles as well as on the corresponding line profiles have to be made. Consequently, additional measurements are performed, which raises the requirement of a benchmark of the applied correction procedure. In contrast, tunable diode laser absorption spectroscopy (TDLAS) on the Balmer-α line is a direct measurement of the H (n = 2) density and is thus suitable for a benchmark. For the ICP under consideration, H (n = 2) densities obtained via TDLAS are near 3 × 1015 m−3 whereas uncorrected VUV emission spectroscopy gives values in the range of roughly 1013 m−3 depending on pressure and applied RF power. The calculated escape factors are on the order of 2–8 × 10−3. An excellent agreement with TDLAS is observed by applying them to the results of the VUV emission spectroscopy.