Qing Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Qing Wang has a total of 66 co-authors. Here are the top co-authors by number of shared publications:
- Wei Zhao
Department of Electrical Engineering, Tsinghua University, Beijing, China
29 shared publications - Songling Huang
Tsinghua University
26 shared publications - Shen Wang
Tsinghua University,State Key Lab of Power Systems,Department of Electrical Engineering,Beijing,China
17 shared publications - Hongyu Sun
School of Physical Science and Engineering, Beijing Jiaotong University, Beijing 100044, China
8 shared publications - Zhe Wang
State Key Laboratory of Power System, Department of Electrical Engineering, Tsinghua University, Beijing 100084, China
8 shared publications Songling Huang
Tsinghua University
6 shared publications
Latest Publications
- 1 January 2023
- Published by The Electromagnetics Academy in Progress In Electromagnetics Research M
- Vol. 120, 1-14
Impact of Phase Noise on Sidelobe Cancellation System Utilizing Distributed Phase-Lock-Loops
- 1 January 2023
- Published by The Electromagnetics Academy in Progress In Electromagnetics Research M
- Vol. 120, 1-14
Impact of Phase Noise on Sidelobe Cancellation System Utilizing Distributed Phase-Lock-Loops
- 18 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (3) , 1826-1836
A SVD-Based Dynamic Harmonic Phasor Estimator With Improved Suppression of Out-of-Band Interference
The diffusion of nonlinear loads and power electronic devices in power systems deteriorates the signal environment, and increases the difficulty of measuring harmonic phasors. Considering accurate harmonic phasor information is necessary to deal with harmonic related issues, this paper focuses on realizing accurate dynamic harmonic phasor estimation when the signal is contaminated by certain interharmonic tones, i.e. the out-of-band interference (OBI). Specifically, this work introduces the singular value decomposition into the Taylor-Fourier transform algorithm, deriving a general decomposition form for harmonic phasor filters, and yielding a set of adjustable parameters. Then these parameters are configured to minimize the negative influence of OBI on the dynamic harmonic phasor filters. Based on the recommended parameter values, the optimized harmonic estimator is obtained, and then tested under signals distorted by OBI, harmonic, noise, and in worse cases, frequency deviation, and some dynamic conditions. Test results show the proposal achieves good harmonic phasor estimation even under multiple interferences and dynamic scenarios, and has a much weaker dependence on OBI tones compared to conventional approaches.
- 18 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (3) , 1826-1836
A SVD-Based Dynamic Harmonic Phasor Estimator With Improved Suppression of Out-of-Band Interference
The diffusion of nonlinear loads and power electronic devices in power systems deteriorates the signal environment, and increases the difficulty of measuring harmonic phasors. Considering accurate harmonic phasor information is necessary to deal with harmonic related issues, this paper focuses on realizing accurate dynamic harmonic phasor estimation when the signal is contaminated by certain interharmonic tones, i.e. the out-of-band interference (OBI). Specifically, this work introduces the singular value decomposition into the Taylor-Fourier transform algorithm, deriving a general decomposition form for harmonic phasor filters, and yielding a set of adjustable parameters. Then these parameters are configured to minimize the negative influence of OBI on the dynamic harmonic phasor filters. Based on the recommended parameter values, the optimized harmonic estimator is obtained, and then tested under signals distorted by OBI, harmonic, noise, and in worse cases, frequency deviation, and some dynamic conditions. Test results show the proposal achieves good harmonic phasor estimation even under multiple interferences and dynamic scenarios, and has a much weaker dependence on OBI tones compared to conventional approaches.
- 28 July 2022
- Published by Science China Press., Co. Ltd. in SCIENTIA SINICA Technologica
- Vol. 53 (2) , 210-220
Heuristic shape formation algorithm in swarm robots based on group auction
集群机器人的图形构造问题是指通过控制集群机器人的运动趋使其形成一个特定的图形. 集群机器人中的图形构造问题通常可以分解为两个子问题: 机器人与目标点之间的任务分配以及机器人与目标点之间的路径规划. 根据集群机器人图形构造问题规模大、易拥堵、碰撞的特点, 提出了一种集中优化、分组拍卖以及分布式交互相结合的OGADI (optimized grouping auction and distributed interaction) 方法, 以缩短图形构造的完成时间. 将OGADI算法与最短路径集诱导顶点排序算法对比, 结果表明, 在集群机器人规模分别为500、1000、1300下, OGADI算法图形构造任务平均完成时间分别缩短了16.1%、13.6%、14.4%, 仿真验证了OGADI算法的可行性和有效性.
- 28 July 2022
- Published by Science China Press., Co. Ltd. in SCIENTIA SINICA Technologica
- Vol. 53 (2) , 210-220
Heuristic shape formation algorithm in swarm robots based on group auction
集群机器人的图形构造问题是指通过控制集群机器人的运动趋使其形成一个特定的图形. 集群机器人中的图形构造问题通常可以分解为两个子问题: 机器人与目标点之间的任务分配以及机器人与目标点之间的路径规划. 根据集群机器人图形构造问题规模大、易拥堵、碰撞的特点, 提出了一种集中优化、分组拍卖以及分布式交互相结合的OGADI (optimized grouping auction and distributed interaction) 方法, 以缩短图形构造的完成时间. 将OGADI算法与最短路径集诱导顶点排序算法对比, 结果表明, 在集群机器人规模分别为500、1000、1300下, OGADI算法图形构造任务平均完成时间分别缩短了16.1%、13.6%、14.4%, 仿真验证了OGADI算法的可行性和有效性.
- 6 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (3) , 3599-3616
Compatibility Issues With Irregular Current Injection Islanding Detection Methods in Multi-DG Units Equipped With Grid-Connected Transformers
Compatibility issues with irregular current injection islanding detection methods are actually the problem that some irregular currents at the same frequency injected into the same line may cancel each other out and then the islanding detection may be impaired, which have been discussed under direct couple conditions (i.e., conditions without grid-connected transformers) in the literature. This article analyzes the issues under the opposite conditions where distributed generation (DG) units are equipped with grid-connected transformers, and is aimed at finding a solution. The analysis derives the setting formulas of key parameters for both three-phase and single-phase DG units, and shows that considering fault tolerance and practicability, only specific frequencies can be used for irregular currents. The usable frequencies are different under different cases. These conclusions are different from those based on direct couple conditions. By summarizing the conclusions based on conditions with grid-connected transformers achieved in this article and those based on direct couple conditions in the literature, a complete solution to compatibility issues is obtained. The conclusions in this article have been verified by the experiments and simulations at the end of this article.
- 6 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (3) , 3599-3616
Compatibility Issues With Irregular Current Injection Islanding Detection Methods in Multi-DG Units Equipped With Grid-Connected Transformers
Compatibility issues with irregular current injection islanding detection methods are actually the problem that some irregular currents at the same frequency injected into the same line may cancel each other out and then the islanding detection may be impaired, which have been discussed under direct couple conditions (i.e., conditions without grid-connected transformers) in the literature. This article analyzes the issues under the opposite conditions where distributed generation (DG) units are equipped with grid-connected transformers, and is aimed at finding a solution. The analysis derives the setting formulas of key parameters for both three-phase and single-phase DG units, and shows that considering fault tolerance and practicability, only specific frequencies can be used for irregular currents. The usable frequencies are different under different cases. These conclusions are different from those based on direct couple conditions. By summarizing the conclusions based on conditions with grid-connected transformers achieved in this article and those based on direct couple conditions in the literature, a complete solution to compatibility issues is obtained. The conclusions in this article have been verified by the experiments and simulations at the end of this article.
- Open Access
- 16 July 2021
- Published by ASME International
Design and Development of Hardware to Analyze and Categorize the Condition of Batteries With the Aim of Enabling Their Re-Use
*This paper covers the design and implementation of an accurate, yet flexible test system for Lithium-Ion batteries. The system makes use of linear charge and discharge circuitry to ensure a low noise control, and can support the simultaneous and independent testing of six cells. The system is controlled and data collected by specialist MatLab© software with a user-friendly GUI.
- 16 July 2021
- Published by ASME International
Open AccessDesign and Development of Hardware to Analyze and Categorize the Condition of Batteries With the Aim of Enabling Their Re-Use
*This paper covers the design and implementation of an accurate, yet flexible test system for Lithium-Ion batteries. The system makes use of linear charge and discharge circuitry to ensure a low noise control, and can support the simultaneous and independent testing of six cells. The system is controlled and data collected by specialist MatLab© software with a user-friendly GUI.
- Open Access
- 16 July 2021
- Published by ASME International
Temperature Control to Increase Inter-Layer Bonding Strength in Fused Deposition Modelling
*Fused Deposition Modelling (FDM) provides opportunities for new development in numerous areas. Z-directional anisotropic strength caused by weak inter-layer bonding has been recognized as the reason for limited industry adoption of FDM. This paper aims to investigate increasing the Z-directional strength of Acrylonitrile Butadiene Styrene (ABS) using a temperature controlled print
- 16 July 2021
- Published by ASME International
Open AccessTemperature Control to Increase Inter-Layer Bonding Strength in Fused Deposition Modelling
*Fused Deposition Modelling (FDM) provides opportunities for new development in numerous areas. Z-directional anisotropic strength caused by weak inter-layer bonding has been recognized as the reason for limited industry adoption of FDM. This paper aims to investigate increasing the Z-directional strength of Acrylonitrile Butadiene Styrene (ABS) using a temperature controlled print
- 7 June 2021
- Published by ASME International in Journal of Nondestructive Evaluation, Diagnostics and Prognostics of Engineering Systems
- Vol. 5 (1)
Early Fault Diagnostic System for Rolling Bearing Faults in Wind Turbines
The operation and maintenance costs of wind farms are always high due to high labor costs and the high replacement cost of parts. Thus, it is of great importance to have real-time monitoring and an early fault diagnostic system to prevent major events, reduce time-based maintenance, and minimize the cost. In this paper, such a two-step system for early stage rolling bearing failures in offshore wind turbines is introduced. First, empirical mode decomposition is applied to minimize the effect of ambient noise. Next, correlation coefficients between a reference signal and test signals are obtained and incipient fault detection is achieved by comparing the results with a threshold value. Through further analysis of the envelope spectrum, sample entropy for selected intrinsic mode functions is obtained, which is further used to train a support vector machine classifier to achieve fault classification and degradation state recognition. The proposed diagnostic approach is verified by experimental tests, and an accuracy of 98% in identifying and classifying rolling bearing failures under various loading conditions is obtained.
- 7 June 2021
- Published by ASME International in Journal of Nondestructive Evaluation, Diagnostics and Prognostics of Engineering Systems
- Vol. 5 (1)
Early Fault Diagnostic System for Rolling Bearing Faults in Wind Turbines
The operation and maintenance costs of wind farms are always high due to high labor costs and the high replacement cost of parts. Thus, it is of great importance to have real-time monitoring and an early fault diagnostic system to prevent major events, reduce time-based maintenance, and minimize the cost. In this paper, such a two-step system for early stage rolling bearing failures in offshore wind turbines is introduced. First, empirical mode decomposition is applied to minimize the effect of ambient noise. Next, correlation coefficients between a reference signal and test signals are obtained and incipient fault detection is achieved by comparing the results with a threshold value. Through further analysis of the envelope spectrum, sample entropy for selected intrinsic mode functions is obtained, which is further used to train a support vector machine classifier to achieve fault classification and degradation state recognition. The proposed diagnostic approach is verified by experimental tests, and an accuracy of 98% in identifying and classifying rolling bearing failures under various loading conditions is obtained.
- 16 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-8
Effective Focal Area Dimension Optimization of Shear Horizontal Point-Focusing EMAT Using Orthogonal Test Method
To overcome the shortcomings of low energy conversion efficiency of electromagnetic acoustic transducers (EMATs), point-focusing shear horizontal (PFSH) wave EMAT is used to focus the wave energy into a specific area. Many factors will affect the capability of the focusing transducer, and in addition to considering the signal intensity, the detection accuracy is also required to be investigated. Specifically, to simplify the test process, we use the orthogonal test method to study the effect of different influence parameters on signal intensity and focal area dimensions. Seven factors are selected, and three results are determined in the test. Range analysis shows that for signal amplitude M, the top three impact factors are the coil width w, coil turns n, and focal length lF (equal to bandwidth factor α). Moreover, magnet number m and frequency f c dominate the effective focal length l fd , and aperture angle θ determines the effective focal width w fd . To enable higher signal intensity and smaller focal area dimensions, it is necessary to consider various factors on the PFSH-EMAT focusing performance. The test's signal intensity with optimized parameters' combination at the focal point is nearly 144.42% higher than the average of all the tests, l fd decreased by 37.84%, and w fd decreased by 50.59%. The experiment also verified that focusing EMAT with optimized parameters has a better focusing performance.
- 16 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-8
Effective Focal Area Dimension Optimization of Shear Horizontal Point-Focusing EMAT Using Orthogonal Test Method
To overcome the shortcomings of low energy conversion efficiency of electromagnetic acoustic transducers (EMATs), point-focusing shear horizontal (PFSH) wave EMAT is used to focus the wave energy into a specific area. Many factors will affect the capability of the focusing transducer, and in addition to considering the signal intensity, the detection accuracy is also required to be investigated. Specifically, to simplify the test process, we use the orthogonal test method to study the effect of different influence parameters on signal intensity and focal area dimensions. Seven factors are selected, and three results are determined in the test. Range analysis shows that for signal amplitude M, the top three impact factors are the coil width w, coil turns n, and focal length lF (equal to bandwidth factor α). Moreover, magnet number m and frequency f c dominate the effective focal length l fd , and aperture angle θ determines the effective focal width w fd . To enable higher signal intensity and smaller focal area dimensions, it is necessary to consider various factors on the PFSH-EMAT focusing performance. The test's signal intensity with optimized parameters' combination at the focal point is nearly 144.42% higher than the average of all the tests, l fd decreased by 37.84%, and w fd decreased by 50.59%. The experiment also verified that focusing EMAT with optimized parameters has a better focusing performance.
- 26 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-9
Defect Detection and Identification of Point-Focusing Shear-Horizontal EMAT for Plate Inspection
As a kind of nondestructive testing (NDT) method, shear-horizontal (SH)-guided wave detection technology is widely used on an electromagnetic acoustic transducer (EMAT). Although ultrasonic-guided waves perform well in defect location, it is difficult to obtain detailed information about defects, and the low efficiency of EMAT energy conversion still reduces the EMAT’s performance. Therefore, in this work, the defect detection method of different shapes and sizes by point-focusing shear-horizontal (PFSH)-guided wave EMAT with the use of periodic permanent magnet (PPM) is investigated through simulation and experiment. For the purpose of defect classification and quantification, the extraction principles of defect features are obtained through simulation based on the circumferential scatter diagrams, and the neural network (NN) is used to process the features extracted from the experimental data. The results show that by extracting effective defect features from the scatter diagram, high-accuracy classification and high-precision quantification of defects under the influence of the focusing transducer can be achieved.
- 26 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-9
Defect Detection and Identification of Point-Focusing Shear-Horizontal EMAT for Plate Inspection
As a kind of nondestructive testing (NDT) method, shear-horizontal (SH)-guided wave detection technology is widely used on an electromagnetic acoustic transducer (EMAT). Although ultrasonic-guided waves perform well in defect location, it is difficult to obtain detailed information about defects, and the low efficiency of EMAT energy conversion still reduces the EMAT’s performance. Therefore, in this work, the defect detection method of different shapes and sizes by point-focusing shear-horizontal (PFSH)-guided wave EMAT with the use of periodic permanent magnet (PPM) is investigated through simulation and experiment. For the purpose of defect classification and quantification, the extraction principles of defect features are obtained through simulation based on the circumferential scatter diagrams, and the neural network (NN) is used to process the features extracted from the experimental data. The results show that by extracting effective defect features from the scatter diagram, high-accuracy classification and high-precision quantification of defects under the influence of the focusing transducer can be achieved.
- 1 February 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (2) , 025006
Characteristic analysis of electromagnetic acoustic transducers for helical shear horizontal wave based on magnetostrictive effect
The electromagnetic ultrasound detection technology provides an efficient method to inspect the structural health status. For the pipeline structure, the guided ultrasonic wave propagating along the axial direction has been the focus of the current research. However, the helical wave owns the advantage of obtaining the defect information in extra angles and has not been explored sufficiently. In this work, a transducer with a sector configuration is designed for generating helical shear horizontal waves in a pipeline. The magnetostrictive effect is analyzed, and the model is built in the finite element simulation software of COMSOL Multiphysics. The electromagnetic field and displacement distribution are studied. To evaluate the performance of the transducer, the half divergence angle is defined to measure the acoustic beam and evaluate the capacity in generating helical waves. Corresponding experiments are also implemented to analyze the influencing factors in the structural design of the transducer. The results indicate that the pulse cycle affects the half divergence angle slightly. The compromise should be considered when designing the central angle of the transducer because it influences the signal amplitude and further imaging resolution in a contradictory way.
- 1 February 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (2) , 025006
Characteristic analysis of electromagnetic acoustic transducers for helical shear horizontal wave based on magnetostrictive effect
The electromagnetic ultrasound detection technology provides an efficient method to inspect the structural health status. For the pipeline structure, the guided ultrasonic wave propagating along the axial direction has been the focus of the current research. However, the helical wave owns the advantage of obtaining the defect information in extra angles and has not been explored sufficiently. In this work, a transducer with a sector configuration is designed for generating helical shear horizontal waves in a pipeline. The magnetostrictive effect is analyzed, and the model is built in the finite element simulation software of COMSOL Multiphysics. The electromagnetic field and displacement distribution are studied. To evaluate the performance of the transducer, the half divergence angle is defined to measure the acoustic beam and evaluate the capacity in generating helical waves. Corresponding experiments are also implemented to analyze the influencing factors in the structural design of the transducer. The results indicate that the pulse cycle affects the half divergence angle slightly. The compromise should be considered when designing the central angle of the transducer because it influences the signal amplitude and further imaging resolution in a contradictory way.