Davide Giavarina

Davide Giavarina

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Davide Giavarina has a total of 474 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Relationship between Residual Urine Output and Type of Dialysis with FGF23 Levels

    by Valentina Corradi, Sara Samoni, Alice Mariotto, Carlotta Caprara, Elisa Scalzotto, Anna Chiara Frigo, Francesca K. Martino, Davide Giavarina, Claudio Ronco, Monica Zanella

    Several studies investigated the role of fibroblast growth factor 23 (FGF23) in the regulation of renal phosphate excretion in chronic kidney disease (CKD). However, patients with residual urine output (UO) seem to control their serum phosphorus levels better. Our aim was to determine whether FGF23 levels are influenced by dialysis modality and UO. We performed a cross-sectional study in hemodialysis (HD) and peritoneal dialysis (PD) patients. The C-terminal FGF23 (cFGF23) levels were determined in plasma with a two-site enzyme-linked immunosorbent assay. The UO collection referred to an mL/day measurement. All p values were two-sided, and the statistical significance was set at p < 0.05. We enrolled 133 patients (58 HD, 75 PD, UO 70%). The median cFGF23 was significantly higher in HD vs. PD patients (p = 0.0017) and not significantly higher in patients without UO (p = 0.12). We found a negative correlation between cFGF23 and the UO volume (p = 0.0250), but the correlation was not significant when considering the type of dialysis treatment. Phosphorus (ß = 0.21677; p = 0.0007), type of dialysis (ß = −0.68392; p = 0.0003), and creatinine (ß = 0.08130; p = 0.0133) were significant and independent predictors of cFGF23 levels. In conclusion, cFGF23 was significantly higher in HD than in PD patients. We found a significant negative correlation between cFGF23 and the residual UO volume, but the correlation was not significant considering the type of dialysis. Our study reveals that dialysis modality is an independent predictor of FGF23 levels. In particular, PD is associated with lower FGF23 levels than HD.


  • Evaluating the role of a fully automated SARS-CoV-2 antigen ECLIA immunoassay in the management of the SARS COV 2 pandemic on general population

    by Mariarosa Carta, Michela Pascarella, Anna Cappelletti, Mario Rassu, Davide Giavarina

    Objectives: Chemiluminescence immunoassay (CLIA) automated assays (fourth-generation antigen test) for SARS-CoV-2 detection are promising because of their analytical productivity, but have lower sensitivity and specificity than rt-PCR assays. The authors of this paper evaluated a recent immunoassay implemented on Siemens Atellica IM, investigating how much this could affect the actual feasibility of this diagnostic during the pandemic. Methods: From the three-day routine 134 positive and 241 negative swab samples by rt-PCR test were evaluated, selected as 1/3 positive – 2/3 negative. Results: Using rt-PCR as gold standard, the specificity of immunoassay was 96.7%, while sensitivity was 68.0%. Sensitivity is inversely proportional to the viral load: 100% for cycles threshold (CT) values from 14 to 29, 95% until 30 CT, then 85, 74, 72, 68%, for 31–35 CT respectively. Conclusions: Our study confirms the reliability of the fourth-generation antigen assay in recognizing negative samples. Conversely, sensitivity appears to be less reliable (68.0%) than reported in the literature. This could be due to a non-randomized study group: many swab samples were taken from patients with expected low viral load (hospitalized for COVID for more than 10–12 days or asymptomatic patients for epidemiological surveillance). The strong correlation of sensitivity and viral load could prove significant to track the infectiousness of infected people, as previous studies reported that a viral load of at least 10E6 copies of RNA/mL, corresponding to 25 CT, is the threshold of transmission of the disease.


  • Open Access

    Subclinical AKI and Clinical Outcomes in Elderly Patients Undergoing Cardiac Surgery: Diagnostic Utility of NGAL versus Standard Creatinine Increase Criteria

    by Matteo Marcello, Grazia Maria Virzì, María-Jimena Muciño-Bermejo, Sabrina Milan Manani, Davide Giavarina, Loris Salvador, Claudio Ronco, Monica Zanella

    Background: Acute kidney injury (AKI) is a common and serious postoperative complication in patients undergoing cardiac surgery and its incidence is particularly high among elderly patients. Cardiac surgery-associated AKI (CSA-AKI) represents the second most common cause of AKI in the intensive care unit but its true incidence could be underestimated, especially in elderly population. The current biomarkers of AKI are unreliable and delayed during acute changes in kidney function. In the setting of subclinical AKI (SAKI), biomarkers of tubular damage, such as NGAL, seem to be an early indicator of kidney damage. The aim of this study was to investigate NGAL utility in the SAKI diagnosis in the first 48 h after cardiac surgery and its helpfulness in predicting adverse clinical outcomes in comparison to current criteria for AKI. Methods: This is an observational study of 72 patients admitted to San Bortolo’s cardiac surgery department for elective cardiosurgical procedure enrolled over a 5-months period. All patients underwent peripheral venous sample 48 h after cardiac surgery to assess plasmatic creatinine (48Cr) and NGAL (48pNGAL) in addition to exams already foreseen by clinical practice. For each patient we studied renal, respiratory and cardiovascular outcome during hospitalization as well as 30 days and 6 months mortality. Creatinine Increase AKI (CrIAKI) was defined by 48CrI ≥0.3 mg/dL and SAKI was defined by 48pNGAL ≥100 pg/dL. We also assessed Respiratory (ArespO) as well as Cardiovascular (ACvO) outcome. Results: Thirty days mortality was 8.3% (6 patients) and 6 months mortality was 12.5% (9 patients). A total of 27 patients (37.5%) presented AKI according to KDIGO (4) and 4 (5.5%) needed renal replacement therapy (RRT). SAKI was significantly associated with 30 days mortality (p = 0.0238), 6 months mortality (p = 0.002), Adverse renal outcome (ARenO) (p = 0.004) and need for RRT (p = 0.005). CrIAKI was significantly associated with 30 days mortality (p = 0.009) and ARenO (p = 0.0001), but not with 6 months mortality nor need for RRT.


  • Open Access

    Neutrophil Gelatinase-Associated Lipocalin (NGAL) in Peritoneal Dialytic Effluent: Preliminary Results on the Comparison between Two Different Methods in Patients with and without Peritonitis

    by Grazia Maria Virzì, Sabrina Milan Manani, Matteo Marcello, Elisa Costa, Davide Marturano, Ilaria Tantillo, Silvia Lerco, Valentina Corradi, Massimo De Cal, Francesca K. Martino, et al.

    Neutrophil gelatinase-associated lipocalin (NGAL) is a lipocalin involved in the immune response and is significantly high in the peritoneal dialytic effluent (PDE) of peritoneal dialysis (PD) patients with inflammation of the peritoneum membrane (peritonitis). The focus of this study was to match two different techniques for peritoneal NGAL evaluation: NGAL point-of-care test-POCT (NGAL Dipstick—NGALds) versus the laboratory-based NGAL assay and with the white cell count in PDE. In this study, we included 30 PD patients: 17 with peritonitis and 13 without. Peritoneal NGAL was tested by a turbidimetric immunoassay and by NGALds. We noticed a good positive linear correlation between the POCT results and the laboratory-based test and between the peritoneal NGALds and white cell count in PDE (both, p < 0.01). NGALds values resulted in being elevated in patients with peritonitis (300 ng/mL, IQR 300–600) in comparison to patients without (100 ng/mL, IQR 50–150) (p < 0.01). Furthermore, the NGALds test was performed in a median time of 20 mins (IQR 18–21) in comparison with the median time of 65 mins (IQR 55–69) necessary for the laboratory-based test (p < 0.01). The results of the NGALds were coherent with the laboratory-based NGAL and with the white cell count in PDE; furthermore, it was a user-friendly method with real-time findings. NGALds could be an extra tool for the diagnosis of peritonitis, helpful at the bedside of the patient, shortening the length of diagnosis, and if the laboratory-based NGAL test is not accessible.


  • Clinical Assessment of Continuous Hemodialysis with the Medium Cutoff EMiC®2 Membrane in Patients with Septic Shock

    by Fiorenza Ferrari, Faeq Husain-Syed, Paola Milla, Anna Lorenzin, Luigia Scudeller, Marco Sartori, Silvia Gramaticopolo, Luigi D’aUria, Angelo Guglielmi, Pietro Cornara, et al.

    Introduction: At the time of renal replacement therapy, approximately 20% of critically ill patients have septic shock. In this study, medium cutoff (MCO) continuous venovenous hemodialysis (CVVHD) was compared to high-flux membrane continuous venovenous hemodiafiltration (CVVHDF) in terms of hemodynamic improvement, efficiency, middle molecule removal, and inflammatory system activation. Methods: This is a monocenter crossover randomized study. Between December 31, 2017, and December 31, 2019, 20 patients with septic shock and stage 3 acute kidney injury (AKI) admitted to 2 Italian ICUs were enrolled. All patients underwent CVVHD with Ultraflux® EMiC®2 and CVVHDF with AV1000S® without washout. Each treatment lasted 24 h. Results: Compared to AV1000S®-CVVHDF, EMIC®2-CVVHD normalized cardiac index (β = −0.64; p = 0.02) and heart rate (β = 5.72; p = 0.01). Interleukin-8 and myeloperoxidase removal were greater with AV1000S®-CVVHDF than with EMiC®2-CVVHD (β = 0.35; p < 0.001; β = 0.43; p = 0.03, respectively). Leukocytosis improved over 24 h in EMiC®2-CVVHD-treated patients (β = 4.13; p = 0.03), whereas procalcitonin levels decreased regardless of the modality (β = 0.89; p = 0.01) over a 48-h treatment period. Reduction rates, instantaneous plasmatic clearance of urea, creatinine, and β2-microglobulin were similar across modalities. β2-Microglobulin removal efficacy was greater in the EMiC®2 group (β = 0–2.88; p = 0.002), while albumin levels did not differ. Albumin was undetectable in the effluent in both treatments. Discussion: In patients with septic shock and severe AKI, the efficacy of uremic toxin removal was comparable between MCO-CVVHD and CVVHDF. Further, MCO-CVVHD was associated with improved hemodynamics. Fraction of filtration and transmembrane pressure reduction and the maintenance of equal efficacy might be the key features of CVVHD with MCO membranes in critically ill patients.


  • Open Access

    Comparison of Anti–SARS-CoV-2 S1 Receptor-Binding Domain Antibody Immunoassays in Health Care Workers Before and After the BNT162b2 mRNA Vaccine

    by Mariarosa Carta, Irene Marinello, Anna Cappelletti, Alessandra Rodolfi, Erica Cerrito, Camilla Bernasconi, Marlene Gottardo, Francesca Dal Lago, Daniele Rizzetto, Elena Barzon, et al.

    The Pfizer-BioNTech BNT162b2 vaccine against SARS-CoV-2 infection is now available. This vaccine induces antibody production against the receptor-binding domain (RBD) of the spike glycoprotein S1 (S1-RBD). This study evaluated the performance of new immunoassays to measure this type of antibody. Blood samples were collected at t0 (prime dose), after 21 days (t1, booster dose), and then after another 15 days (t2) from 70 health care professionals who had tested negative for previous SARS-CoV-2 infection and underwent vaccination with BNT162b2. Antibodies against S1-RBD were measured using 4 commercial assays. At t0, t1, and t2, the median antibody concentrations (interquartile range) were, respectively, 0.2 (0.1-0.4), 49.5 (19.1-95.7), and 888.0 (603.6-1,345.8) U/mL by Maglumi SARS-CoV-2 S-RBD immunoglobulin G (IgG) (Shenzen New Industries Biomedical Engineering, Snibe Diagnostics); 0.0 (0.0-0.0), 7.9 (4.2-15.6), and 112.3 (76.4-205.6) U/mL by Atellica IM SARS-CoV-2 IgG assay (Siemens Healthineers); 0.0 (0.0-0.0), 59.9 (18.3-122.0), and 2,646.0 (1,351.2-4,124.0) U/mL by Elecsys Anti–SARS-CoV-2 S assay (Roche Diagnostics); and 1.8 (1.8-1.8), 184 (94-294), and 1,841.0 (1,080.0-2,900.0) AU/mL by LIAISON SARS-CoV-2 TrimericS IgG assay (DiaSorin). The differences between medians at t0, t1, and t2 were all statistically significant (P < .001). Antibodies against nucleocapsid proteins (N) were also measured using Maglumi 2019-nCoV IgG assay, which showed all negative results. All the considered anti-RBD methods detected response to the vaccine, while the method directed against anti-N failed to show response.


  • Improvements and limits of anti SARS-CoV-2 antibodies assays by WHO (NIBSC 20/136) standardization

    by Davide Giavarina, Mariarosa Carta

    Objectives: A few CLIA automated immunoassays for the recognition of anti S1-RBD SARS-CoV-2 antibodies have recently been placed on the market. Preliminary data demonstrate a high correlation between methods but wide differences in absolute concentrations. A new WHO international standard for anti-SARS-CoV-2 immunoglobulin, NIBSC code 20/136, has been recently introduced to reduce the differences. The aim of this study is thus to verify the harmonization made by NIBSC 20/136 on Ab anti S1-RBD measurement on real samples. Methods: The following assays were studied: LIAISON ® SARS-CoV-2 TrimericS IgG (DiaSorin); Elecsys ® anti-SARS-CoV-2 S (ROCHE); Atellica IM SARS-CoV-2 IgG (sCOVG) (Siemens); MAGLUMI ® SARS-CoV-2 S-RBD IgG (Snibe), measuring 210 samples from 70 health workers with no previous SARS-CoV2 infection, during their Pfizer-BioNTech’s BNT162b2 vaccination period. Results: The recalculation of concentrations based on the NIBSC 20/136 standardization improve the analytical and diagnostic comparability but do not cancel this variability between methods: recalibrated results remain different across methods, both in terms of tendency and single data. Conclusions: The recalculation of concentrations based on the NIBSC 20/136 standardization improves the analytical and diagnostic comparability but does not cancel the differences between methods: recalibrated results remain different across methods, both in terms of tendency and single data.


  • Clinical Implications of the New Equation to Estimate Glomerular Filtration Rate

    by Davide Giavarina, Faeq Husain-Syed, Claudio Ronco

    Recently, a new full-age spectrum equation was proposed by the European Kidney Function Consortium (EKFC) to overcome the difficulty of using multiple glomerular filtration rate (GFR) estimation equations and problems of implausible changes in GFR during the transition from adolescence to adulthood and address GFR overestimation in young adults and in the older adults. To verify the impact on patient classifications, we applied the new equation to data of 38,188 adult patients, comparing GFR estimation using the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) and EKFC equations. As expected, our data indicate that a significant proportion of patients will be reclassified downward by the EKFC compared to the CKD-EPI equation with a particular reference between CKD stages 1–2 and 2–3 and age categories of 18–30 and ≥61 years, respectively. Clinicians should be aware that any replacement for the EKFC equation will entail a period of different results in estimated GFR during the transition from the previous to the new equation.


  • Prospective serological evaluation of anti SARS-CoV-2 IgG and anti S1-RBD antibodies in a community outbreak

    by Mariarosa Carta, Luciana Bragagnolo, Andrea Tramarin, Anna Cappelletti, Elena Barzon, Lauretta Forner, Maria Grazia Meneghini, Chiara Tripodi, Marlene Gottardo, Francesca Dal Lago, et al.

    Article Prospective serological evaluation of anti SARS-CoV-2 IgG and anti S1-RBD antibodies in a community outbreak was published on July 1, 2021 in the journal Clinical Chemistry and Laboratory Medicine (CCLM) (volume 59, issue 8).