MNMarta Nycz

Marta Nycz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Marta Nycz has a total of 17 co-authors. Here are the top co-authors by number of shared publications:

  • Katarzyna Arkusz

    University of Zielona Gora 9 Licealna Street

    6 shared publications
  • Dorota Genowefa Pijanowska

    Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Ks. Trojdena 4, Warszawa 02-109, Poland

    2 shared publications
  • Dorota Genowefa Pijanowska

    Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland

    2 shared publications
  • Ewa Paradowska

    Univ Zielona Gora, Fac Mech Engn, Dept Biomed Engn, Ul Prof Szafrana 4, PL-65516 Zielona Gora, Poland

    2 shared publications
  • Ewa Paradowska

    Department of Biomedical Engineering, Faculty of Mechanical Engineering, University of Zielona Gora, Licealna 9 Street, 65-417 Zielona Gora, Poland

    2 shared publications
  • Katarzyna Arkusz

    Department of Biomedical Engineering, Faculty of Engineering and Technical Sciences, University of Zielona Gora, Prof. Z. Szafrana 4, Zielona Gora 65-516, Poland

    2 shared publications

Latest Publications

  • Open Access

    From Nano- to Microsilver: Morphology Control and Shape Evolution of Facile One-Step Electrochemical Synthesis of Silver Particles on TiO2 Nanotubes

    by Marta Nycz, Katarzyna Arkusz

    Nano- and microsilver (Ag) exhibit a wide range of desirable catalytic, electronic, adsorption, and antimicrobial features, complementing the excellent properties of titanium dioxide (TiO2) nanotubes by increasing their specific surface area. Formed via electrodeposition processes, it has advantages such as high purity; the methodology is repeatable, reproducible, fast, and easy. Anodically produced TiO2 nanotubes were modified with nano- and microsilver by electrodeposition from silver nitrate solution using cyclic voltammetry and chronoamperometry. The mechanisms of electrodeposition and evolution of silver morphology were analyzed based on cyclic voltammograms/current density-time curves and micrographs taken using a scanning electron microscope. The variables were the AgNO3 precursor solution's concentration, applied voltage, and number of cycles or deposition time. It was proven that there is a universal mechanism for the evolution of the morphology of the deposited silver, regardless of the electrodeposition method used. With the increase of the precursor concentration, deposition time, and applied voltage, the silver grows and reorients according to the following scheme: initially deposited Ag has the form of clusters of Ag nanoparticles resembling nanoflowers, nanoleaves, and spherical nanoparticles, which over time through aggregation create short dendrites and then develop subsequent multilevel branches to evolve into interconnected microsized particles.


  • Open Access

    Shedding light on the problem: Influence of the radiator power, source-sample distance, and exposure time on the performance of UV-C lamps in laboratory and real-world conditions

    by Katarzyna Arkusz, Kamila Pasik, Aleksandra Jędrzejewska, Tomasz Klekiel, Waldemar Woźniak, Marta Nycz, Roman Stryjski

    Effective surface disinfection is crucial for preventing the spread of pathogens in hospitals. Standard UltraViolet-C (UV-C) lamps have been widely used for this purpose, but their disinfection efficiency under real-world conditions is not well understood. To fill this gap, the influence of the power of the ultraviolet radiator, source-sample distance, and exposure time on the performance of UV-C lamps against Escherichia coli and Staphylococcus epidermidis were experimentally determined in the laboratory and hospital. The obtained results showed that the UV irradiance and, thus, the UV-C disinfection efficiency decreased significantly at distances greater than 100 cm from the UV-C lamp. Moreover, increasing the total power of the radiators does not improve the performance of UV-C lamps under real conditions. The UV-C disinfection efficiency greater than 90% was achieved only under laboratory conditions at a close distance from the UV-C lamp, i.e., 10 cm. These findings provide novel insights into the limitations of UV-C lamps in real-world conditions and highlight the need for more effective disinfection strategies in hospitals.


  • Open Access

    Understanding technical cleanliness: importance, assessment, maintenance

    by Joanna Faber, Krzysztof Brodzik, Marta Nycz

    Development of the automotive industry, including so-called dowsizing and rightsizing, entails the need to ensure, and hence to verify, the stringent cleanliness levels of an increasing number of car components. The assurance of proper cleanliness level requires knowledge of the entire production process and precise information on the contaminants that will allow to identify their sources. Obtaining reliable cleanliness information requires establishing of many different factors, i. a. selection of proper contamination extraction and collection technique, proper parameters of extraction, validation of extraction procedure, methods of particles analysis. Analytical techniques which are implemented include gravimetric, optical microscopy and advanced techniques like scanning electron microscopy. This work present’s actual state of knowledge regarding technical cleanliness analysis of components. Important aspects of QA&QC in technical cleanliness assessment are also discussed.


  • Open Access

    Fabrication of Electrochemical Biosensor Based on Titanium Dioxide Nanotubes and Silver Nanoparticles for Heat Shock Protein 70 Detection

    by Marta Nycz, Katarzyna Arkusz, Dorota G. Pijanowska

    This paper presents the fabrication methodology of an electrochemical biosensor for the detection of heat shock protein 70 (HSP70) as a potential tumor marker with high diagnostic sensitivity. The sensor substrate was a composite based on titanium dioxide nanotubes (TNTs) and silver nanoparticles (AgNPs) produced directly on TNTs by electrodeposition, to which anti-HSP70 antibodies were attached by covalent functionalization. This manuscript contains a detailed description of the production, modification, and the complete characteristics of the material used as a biosensor platform. As-formed TNTs, annealed TNTs, and the final sensor platform—AgNPs/TNTs, were tested using scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), and X-ray diffraction analysis (XRD). In addition, open circuit potential (OCP), electrochemical impedance spectroscopy (EIS), and cyclic voltammetry (CV) of these substrates were used to assess the influence of TNTs modification on their electrochemical characteristics. The EIS technique was used to monitor the functionalization steps of the AgNPs/TNTs electrode and the interaction between anti-HSP70 and HSP70. The produced composite was characterized by high purity, and electrical conductivity improved more than twice compared to unmodified TNTs. The linear detection range of HSP70 of the developed biosensor was in the concentration range from 0.1 to 100 ng/mL.


  • Electrodes Based on a Titanium Dioxide Nanotube–Spherical Silver Nanoparticle Composite for Sensing of Proteins

    by Marta Nycz, Katarzyna Arkusz, Dorota Genowefa Pijanowska

    The aim of the research was to provide electrochemical, chemical, phase, and microscopic characteristics of electrodes based on titanium dioxide nanotubes (TNTs) containing uniformly deposited, nonagglomerated spherical silver nanoparticles (AgNPs). The nanoparticles were produced with the use of electrodeposition and sputter deposition methods. This paper presents the results of research of these platforms with the use of the following techniques: electrochemical impedance spectroscopy, X-ray diffraction analysis, X-ray photoelectron spectroscopy, and scanning electron microscopy. Evaluation of the adsorption of proteins—bovine serum albumin (BSA)—was carried out to establish the possibility of the use of the electrodes in a low-cost, simple detection system without surface functionalization. The research proved that the AgNP deposition facilitated the electron transfer increasing their conductivity properties as well as promoting the protein adsorption. The AgNPs/TNT electrodes showed a high selectivity to the BSA–anti-BSA complex. Half an hour of immobilization was enough to completely saturate the TNT electrodes, whereas for AgNPs/TNTs, 1 h of immobilization seemed to be not enough. The impedance parameter changes for electrodes with the AgNPs reached even about 300%. The biggest changes were noted for the platform obtained using cyclic voltammetry, so it is the best detection platform for biosensing.


  • Influence of geometry and annealing temperature in argon atmosphere of TiO2 nanotubes on their electrochemical properties

    by Marta Nycz, Ewa Paradowska, Katarzyna Arkusz, Dorota Genowefa Pijanowska

    Purpose: In this paper, electrochemical properties of the as-formed and thermally treated titanium dioxide (TiO2) nanotubes with diameter in the range of 20-100 nm and height in the range of 100-1000 nm were presented. In addition, the effects of annealing temperature (450-550 degrees C) on the electrochemical characteristics of these structures, as well as the influence of diameter and height of TiO2 nanotubes on these properties were examined. The results were referred to a compact TiO2 layer (100 nm thick). Methods: The electrochemical test included open circuit potential, impedance spectroscopy and cyclic voltammetry measurements. The scanning electron microscope with energy dispersive spectroscopy analyser, x-ray photoelectron spectroscopy, and x-ray diffraction analysers were used for surface morphology characterisation as well as elemental, phase and chemical composition of TiO2 layers. Results: It was found that nanotubes with the diameter of 50 and 75 nm (height of 1000 nm) annealed at 550 degrees C exhibit the lowest impedance and phase angle values. However, the voltammetric detection of potassium ferricyanide indicated that the closest to 1 I-pc/I-pa ratio were shown by nanotubes with a diameter of 50 and 75 nm annealed at 450 degrees C. Conclusions: On the basis of performed analysis, it can be stated that the TiO2 layer with nanotubes of 50 nm in diameter and of 1000 nm in height, annealed in 450 degrees C may be indicated as the ones having the most favourable sensing and biosensing properties.


  • Open Access

    Electrochemical Evaluation of the Compact and Nanotubular Oxide Layer Destruction under Ex Vivo Ti6Al4V ELI Transpedicular Screw Implantation

    by Katarzyna Arkusz, Marta Nycz, Ewa Paradowska

    Nano-engineered implants are a promising orthopedic implant modification enhancing bioactivity and integration. Despite the lack of destruction of an oxide layer confirmed in ex vivo and in vivo implantation, the testing of a microrupture of an anodic layer initiating immune-inflammatory reaction is still underexplored. The aim of this work was to form the compact and nanotubular oxide layer on the Ti6Al4V ELI transpedicular screws and electrochemical detection of layer microrupture after implantation ex vivo by the Magerl technique using scanning electron microscopy and highly sensitive electrochemical methods. For the first time, the obtained results showed the ability to form the homogenous nanotubular layer on an Ti6Al4V ELI screw, both in α and β-phases, with favorable morphology, i.e., 35 ÷ 50 ± 5 nm diameter, 1500 ± 100 nm height. In contrast to previous studies, microrupture and degradation of both form layers were observed using ultrasensitive electrochemical methods. Mechanical stability and corrosion protection of nanotubular layer were significantly better when compared to compact oxide layer and bare Ti6Al4V ELI.


  • Open Access

    Influence of the Silver Nanoparticles (AgNPs) Formation Conditions onto Titanium Dioxide (TiO2) Nanotubes Based Electrodes on Their Impedimetric Response

    by Marta Nycz, Katarzyna Arkusz, Dorota Genowefa Pijanowska

    This paper presents the comparison of the effects of three methods of production of silver spherical and near-spherical nanoparticles (AgNPs) on the titanium dioxide nanotubes (TNT) base: cyclic voltammetry, chronoamperometry, and sputter deposition. It also evaluates the influence of silver nanoparticles on the electrochemical properties of the developed electrodes. The novelty of this research was to fabricate regular AgNPs free of agglomerates uniformly distributed onto the TNT layer, which has not been accomplished with previous attempts. The applied methods do not require stabilizing and reducing reagents. The extensive electrochemical characteristic of AgNP/TNT was performed by open circuit potential and electrochemical impedance spectroscopy methods. For AgNPs/TNT obtained by each method, the impedance module of these electrodes was up to 50% lower when compared to TNT, which means that AgNPs enabled more efficient electron transfer due to the effective area increase. In addition, the presence of nanoparticles increases the corrosion resistance of the prepared electrodes. These substrates can be used as electrochemical sensors due to their high electrical conductivity, and also as implants due to the antibacterial properties of both the TNT and AgNPs.


  • Surface analysis of long-term hemodialysis catheters made of carbothane (poly(carbonate)urethane) before and after implantation in the patients' bodies

    by Marta Nycz, Ewa Paradowska, Katarzyna Arkusz, Bartosz Kudlinski, Elzbieta Krasicka-Cydzik

    Purpose: The vascular cannulation is associated with a number of complications. The aim of this work was to study the composition and distribution of the film covering the surfaces of Mahurkar Maxid and Palindrome catheters, which were removed from the body of long-term hemodialysis patients. Moreover, the roughness and contact angle of the catheters were evaluated. Methods: Two brand new (as a reference) and thirty used catheters were the subject of the study. Their implantation period lasted from 4 months to a year and the reason for removal was the production of another vascular access or obstruction. Surfaces were analyzed by scanning electron microscope, atomic force microscope and goniometer. Results: The inner surfaces of the used catheters were covered with a film of various complexity which includes a plurality of protein, blood cell counts and the crystals. The closer to the distal part the film becomes more complex and multi-layered. Even the surfaces of brand new catheter were not completely smooth. The only significant difference between analyzed models was the presence of thrombus in the distal part of Mahurkar Maxid catheters, not in the Palindrome. Conclusions: The distal part of the catheters is the place most exposed to obstruction and infection, which may be due to not reaching the anticoagulant agent into this part. Not only the occurrence of side holes affects the formation of thrombus, but also their quantity, geometry and distribution which effect on fluid mechanics. The surface of the catheters needs to improvement to minimize the occurrence of defects and cracks.


  • Open Access

    Examination of Deteriogenic Biofilms on Building Facades with Scanning Electron Microscopy / Badanie Deteriogennych Nalotów Biologicznych Na Elewacjach Budynków Metodą Elektronowej Mikroskopii Skaningowej

    by Marlena Piontek, Hanna Lechów, Ewa Paradowska, Marta Nycz

    Destruction of facades is a complex process in which technical material changes its properties, and which is caused by depositing biological agents. The examination of biofilms from building facades is difficult because sampling for tests may result in the damage to the structure of the facade’s material. Also biological analysis of the material obtained from a biofilm is arduous. Some species of microorganisms are impossible to be isolated and their pure cultures cannot be cultivated in laboratory conditions. It is multispecies cultures that most frequently develop on the surfaces of the facade’s technical material. Clustered in a group, they cooperate with each other and reveal different features than single cells. It is essential to identify organisms present in the biofilms, since they may initiate deterioration processes. The aim of the research was the observation of the biofilm, collected from two facades, in a micrometer scale with the use of a scanning electron microscope