Grazia Poidomani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Grazia Poidomani has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Lina Zuccatosta
Pulmonary Diseases Unit, Azienda Ospedaliero-Universitaria Ospedali Riuniti, Ancona
2 shared publicationsMartina Bonifazi
Pulmonary Diseases Unit, Azienda Ospedaliero-Universitaria Ospedali Riuniti, Ancona
2 shared publications- Stefano Gasparini
Polytechnic University of Marche Region
2 shared publications - Carlo Vancheri
Department of Clinical and Experimental Medicine, Regional Referral Center for Rare Lung Diseases, Policlinico “G.Rodolico-San Marco”, University of Catania, 95123 Catania, Italy
1 shared publication Chiara Lo Nigro
1 shared publication- Claudia Crimi
Department of Clinical and Experimental Medicine, University of Catania, 95123 Catania, Italy
1 shared publication
Latest Publications
- 1 January 2015
- Published by S. Karger AG in Respiration
- Vol. 89 (1) , 49-56
Fully Covered Self-Expandable Metal Stent in Tracheobronchial Disorders: Clinical Experience
Background: The third-generation fully covered self-expandable metallic stent (SEMS) has been developed to solve the problems of difficult removal and in-stent granuloma formation related to the uncovered or partially covered type. There are few written reports about the performance of this type of stents with early encouraging results. Objectives: To report and analyse our experience with the Silmet® stent in the management of malignant and benign tracheobronchial disorders. Methods: We retrospectively reviewed medical records of patients who underwent fully covered SEMS Silmet placement at the Interventional Pulmonology Unit, La Maddalena Cancer Center, Palermo, Italy, between May 2010 and August 2013. Results: Stents were placed in 52 patients with malignant (n = 49) and benign airway obstruction (n = 2) and broncho-oesophageal fistula (n = 1). SEMSs were inserted into the trachea (n = 19), the main bronchi (n = 21) and the peripheral bronchi (n = 31). Besides 1 procedural dislocation, the deployment was successful in all patients with an immediate significant improvement of symptoms (Barthel Index p < 0.001; Medical Research Council score p < 0.001). A radiographic improvement was detected in 48% of patients. The mean follow-up duration was 119 ± 120 days (range 22-549 days). Complications observed were: migration (7.6%), tumour overgrowth (15%), infections (5.7%), granulation tissue formation (3.8%) and mucus plug (3.8%). Conclusions: The Silmet stent is effective, safe and simple to implant and remove. We suggest its use in cases of tight stenoses, in the treatment of small- to medium-caliber airways or in cases of tortuous airways.
- 1 January 2015
- Published by S. Karger AG in Respiration
- Vol. 89 (1) , 49-56
Fully Covered Self-Expandable Metal Stent in Tracheobronchial Disorders: Clinical Experience
Background: The third-generation fully covered self-expandable metallic stent (SEMS) has been developed to solve the problems of difficult removal and in-stent granuloma formation related to the uncovered or partially covered type. There are few written reports about the performance of this type of stents with early encouraging results. Objectives: To report and analyse our experience with the Silmet® stent in the management of malignant and benign tracheobronchial disorders. Methods: We retrospectively reviewed medical records of patients who underwent fully covered SEMS Silmet placement at the Interventional Pulmonology Unit, La Maddalena Cancer Center, Palermo, Italy, between May 2010 and August 2013. Results: Stents were placed in 52 patients with malignant (n = 49) and benign airway obstruction (n = 2) and broncho-oesophageal fistula (n = 1). SEMSs were inserted into the trachea (n = 19), the main bronchi (n = 21) and the peripheral bronchi (n = 31). Besides 1 procedural dislocation, the deployment was successful in all patients with an immediate significant improvement of symptoms (Barthel Index p < 0.001; Medical Research Council score p < 0.001). A radiographic improvement was detected in 48% of patients. The mean follow-up duration was 119 ± 120 days (range 22-549 days). Complications observed were: migration (7.6%), tumour overgrowth (15%), infections (5.7%), granulation tissue formation (3.8%) and mucus plug (3.8%). Conclusions: The Silmet stent is effective, safe and simple to implant and remove. We suggest its use in cases of tight stenoses, in the treatment of small- to medium-caliber airways or in cases of tortuous airways.
- Open Access
- 1 January 2008
- Published by Japanese Society of Internal Medicine in Internal Medicine
- Vol. 47 (15) , 1415-1417
Subsegmental Pulmonary Embolism: Value of Thoracic Ultrasound for Diagnosis and Follow-Up
Timely diagnosis of pulmonary embolism (PE) is crucial because prompt appropriate management can decrease mortality and morbidity. However, the diagnosis of PE is often a challenge because of aspecific clinical presentation and the lack of a single non-invasive diagnostic test sufficiently sensitive for the diagnosis in all suspected cases. The present report describes a 37-year-old woman in whom diagnosis of recurrent subsegmental PE was achieved through subtle integration of imaging techniques including thoracic ultrasound (TUS) that was demonstrated to be of valuable usefulness. We think that TUS may represent an adjunctive technique for diagnosing PE.
- 1 January 2008
- Published by Japanese Society of Internal Medicine in Internal Medicine
- Vol. 47 (15) , 1415-1417
Open AccessSubsegmental Pulmonary Embolism: Value of Thoracic Ultrasound for Diagnosis and Follow-Up
Timely diagnosis of pulmonary embolism (PE) is crucial because prompt appropriate management can decrease mortality and morbidity. However, the diagnosis of PE is often a challenge because of aspecific clinical presentation and the lack of a single non-invasive diagnostic test sufficiently sensitive for the diagnosis in all suspected cases. The present report describes a 37-year-old woman in whom diagnosis of recurrent subsegmental PE was achieved through subtle integration of imaging techniques including thoracic ultrasound (TUS) that was demonstrated to be of valuable usefulness. We think that TUS may represent an adjunctive technique for diagnosing PE.