Justin Fong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Justin Fong has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Denny Oetomo
Department of Mechanical Engineering, The University of Melbourne, Melbourne, Australia
11 shared publications Vincent Crocher
The University of Melbourne
11 shared publications- Ying Tan
Peking University
10 shared publications Ying Tan
The University of Melbourne
9 shared publicationsDenny Oetomo
The University of Melbourne
8 shared publications- Iven Mareels
The University of Melbourne
7 shared publications
Latest Publications
- 8 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Human-Machine Systems
- Vol. 56 (1) , 2-11
Quantifying Manual Adjustment of Foot Placement Under a Fixed Robotic Trajectory in Lower Limb Exoskeletons
Controlling foot placement is a key challenge in the use of assistive lower limb exoskeletons designed for those with motor impairments. Due to the mechanical flexibility of exoskeletons, users can intentionally manipulate the resulting step length without alteration of the exoskeleton’s reference trajectory. This is generally achieved by manually applying wrench upon the exoskeleton and the ground using crutches. This work sought to investigate this mechanism as a deliberate means to control foot placement. Ten nondisabled participants were asked to pilot a user-balanced exoskeleton to target step lengths of 0.1 to 0.4 m, with the exoskeleton trajectory unchanged throughout the experiment. Performance was evaluated by mean absolute error (MAE) and standard deviation (SD) of resulting step lengths. To explore the degree that these results might apply to users with impairments, participants were asked to minimize leg muscle activations during the experiment. Simultaneously, surface electromyography (sEMG) data were collected and normalized between resting (0.0) and unassisted walking (1.0). Activations ranged between 0.014 and 2.853, and were used to categorize participants into High muscle activation (HMA) and Low muscle activation (LMA) groups. The LMA group (median MAE 0.026 m, SD 0.028 m) performed differently compared to the HMA group (median MAE 0.021 m, SD 0.021 m), however, most participants achieved acceptable performance across all target step lengths, compared to a 0.05 m guideline. The results confirm that step length can be controlled through exoskeleton users’ manual efforts. Whilst the range of adjustments may vary with device and user, this could facilitate simplified exoskeleton control strategies and an intuitive method of user control.
- 8 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Human-Machine Systems
- Vol. 56 (1) , 2-11
Quantifying Manual Adjustment of Foot Placement Under a Fixed Robotic Trajectory in Lower Limb Exoskeletons
Controlling foot placement is a key challenge in the use of assistive lower limb exoskeletons designed for those with motor impairments. Due to the mechanical flexibility of exoskeletons, users can intentionally manipulate the resulting step length without alteration of the exoskeleton’s reference trajectory. This is generally achieved by manually applying wrench upon the exoskeleton and the ground using crutches. This work sought to investigate this mechanism as a deliberate means to control foot placement. Ten nondisabled participants were asked to pilot a user-balanced exoskeleton to target step lengths of 0.1 to 0.4 m, with the exoskeleton trajectory unchanged throughout the experiment. Performance was evaluated by mean absolute error (MAE) and standard deviation (SD) of resulting step lengths. To explore the degree that these results might apply to users with impairments, participants were asked to minimize leg muscle activations during the experiment. Simultaneously, surface electromyography (sEMG) data were collected and normalized between resting (0.0) and unassisted walking (1.0). Activations ranged between 0.014 and 2.853, and were used to categorize participants into High muscle activation (HMA) and Low muscle activation (LMA) groups. The LMA group (median MAE 0.026 m, SD 0.028 m) performed differently compared to the HMA group (median MAE 0.021 m, SD 0.021 m), however, most participants achieved acceptable performance across all target step lengths, compared to a 0.05 m guideline. The results confirm that step length can be controlled through exoskeleton users’ manual efforts. Whilst the range of adjustments may vary with device and user, this could facilitate simplified exoskeleton control strategies and an intuitive method of user control.
- 30 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (12) , 19821-19833
Portable Support Polygon Measurement System in Walking Aid Supported Gait
Accurate measurement of the support polygon is crucial for assessing balance and stability during gait. This is of particular concern for individuals requiring a walking aid such as a cane or crutch. However, existing methods require fixed infrastructure or time consuming setup, hindering community-based assessments and applications. This work introduces a novel system that uses sensors mounted to a cane or other gait aid, and a Manifold Extended Kalman Filtering technique to estimate the relative contact surface locations between the user and the ground, even in the presence of intermittent measurements. The proposed technique serves as a versatile framework for various applications requiring relative pose information. The performance of a computer-tethered prototype was evaluated in three configurations against a laboratory-based motion capture system yielding Mean Absolute Errors (MAE) of 20-62mm in the horizontal plane for the feet and crutch positions. To isolate the effects of measurement intermittency from measurement accuracy, the algorithm was also run with simulated measurements with zero error, but with the same intermittency, resulting in MAEs of 8-20mm. These findings demonstrate the feasibility of the approach and underscore the significance of sensor accuracy. Due to only requiring sensors on the walking aid, the proposed system may offer a practical solution for balance evaluation in community-based applications.
- 30 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (12) , 19821-19833
Portable Support Polygon Measurement System in Walking Aid Supported Gait
Accurate measurement of the support polygon is crucial for assessing balance and stability during gait. This is of particular concern for individuals requiring a walking aid such as a cane or crutch. However, existing methods require fixed infrastructure or time consuming setup, hindering community-based assessments and applications. This work introduces a novel system that uses sensors mounted to a cane or other gait aid, and a Manifold Extended Kalman Filtering technique to estimate the relative contact surface locations between the user and the ground, even in the presence of intermittent measurements. The proposed technique serves as a versatile framework for various applications requiring relative pose information. The performance of a computer-tethered prototype was evaluated in three configurations against a laboratory-based motion capture system yielding Mean Absolute Errors (MAE) of 20-62mm in the horizontal plane for the feet and crutch positions. To isolate the effects of measurement intermittency from measurement accuracy, the algorithm was also run with simulated measurements with zero error, but with the same intermittency, resulting in MAEs of 8-20mm. These findings demonstrate the feasibility of the approach and underscore the significance of sensor accuracy. Due to only requiring sensors on the walking aid, the proposed system may offer a practical solution for balance evaluation in community-based applications.
- 3 November 2023
- Published by Elsevier
- p. 39-65
Fundamentals of neurorehabilitation robotics (engineering perspective)
- 3 November 2023
- Published by Elsevier
- p. 39-65
Fundamentals of neurorehabilitation robotics (engineering perspective)
- 1 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2021, 7574-7577
The Effect of Crutch Gait Pattern on Shoulder Reaction Force when Walking with Lower Limb Exoskeletons
Lower limb exoskeleton robots have shown great potential in assistive and rehabilitative applications, allowing individuals with motor impairment, such as spinal cord injury (SCI) patients, to perform overground gait. Most assistive lower limb exoskeletons require users to use crutches to balance themselves during standing and walking. However, long-term crutch usage has been demonstrated to be potentially harmful to the shoulder joints, due to the repetitive high shoulder reaction forces. Investigations into the shoulder loads experienced during exoskeleton use are needed to understand the extent of this harm and, if required, to reduce the risk of injury. In this preliminary study, the effects of different gait patterns on the shoulder load are investigated in an experiment involving three able-bodied individuals. Specifically, the differences in shoulder load during exoskeleton walking are studied with two commonlyobserved gait patterns: (1) the four-point parallel crutch gait and (2) the four-point reciprocal crutch gait. Contact forces between the ground and the human-exoskeleton system were recorded and used to indicate shoulder reaction force. The results suggested no significant differences in maximum force and maximum rate of loading between the two crutch gait patterns, and only minor differences in force time integral. This indicates that shoulder reaction force may not be a significant factor when choosing between crutch gaits during exoskeleton use.
- 1 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2021, 7574-7577
The Effect of Crutch Gait Pattern on Shoulder Reaction Force when Walking with Lower Limb Exoskeletons
Lower limb exoskeleton robots have shown great potential in assistive and rehabilitative applications, allowing individuals with motor impairment, such as spinal cord injury (SCI) patients, to perform overground gait. Most assistive lower limb exoskeletons require users to use crutches to balance themselves during standing and walking. However, long-term crutch usage has been demonstrated to be potentially harmful to the shoulder joints, due to the repetitive high shoulder reaction forces. Investigations into the shoulder loads experienced during exoskeleton use are needed to understand the extent of this harm and, if required, to reduce the risk of injury. In this preliminary study, the effects of different gait patterns on the shoulder load are investigated in an experiment involving three able-bodied individuals. Specifically, the differences in shoulder load during exoskeleton walking are studied with two commonlyobserved gait patterns: (1) the four-point parallel crutch gait and (2) the four-point reciprocal crutch gait. Contact forces between the ground and the human-exoskeleton system were recorded and used to indicate shoulder reaction force. The results suggested no significant differences in maximum force and maximum rate of loading between the two crutch gait patterns, and only minor differences in force time integral. This indicates that shoulder reaction force may not be a significant factor when choosing between crutch gaits during exoskeleton use.
- Open Access
- 12 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 29 (15344320) , 1403-1412
Inducing Human Motor Adaptation Without Explicit Error Feedback: A Motor Cost Approach
Recent studies have shown that motor adaptation is an optimisation process on both kinematic error and effort. This work aims to induce a motor adaption in an experimental setup solely relying on the effort without any explicit kinematic error. In this experiment, the intervention space and adaptation space are decoupled: while the force field only applies to the hand linear velocity, the adaptation is expected to happen in the arm joint null space (i.e. the swivel angle). The primary hypothesis is that such an effort-based force field can induce a movement pattern change in an indirect manner. Secondarily, assuming that this adaptation may be further promoted through subtle prompts to explore the cost space, a variation of the approach with a progressive goal is also tested. Twenty naive subjects were allocated into two groups with slightly different implementations of the force field: one with a Constant Goal (CG) and another one with a Progressively changing Goal (PG). Subjects were asked to perform reaching tasks while attached to a 3D manipulandum. During the intervention, the device applied a resistive viscous force at the subject's hand as a function of the subject's swivel angle to encourage an increase of the latter. Significant increases of the swivel angle of 4.9° and 6.3° were observed for the CG and the PG groups respectively. This result confirms the feasibility of inducing motor adaptation in the redundant joint space by providing a task space intervention without explicit error feedback.
- 12 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 29 (15344320) , 1403-1412
Open AccessInducing Human Motor Adaptation Without Explicit Error Feedback: A Motor Cost Approach
Recent studies have shown that motor adaptation is an optimisation process on both kinematic error and effort. This work aims to induce a motor adaption in an experimental setup solely relying on the effort without any explicit kinematic error. In this experiment, the intervention space and adaptation space are decoupled: while the force field only applies to the hand linear velocity, the adaptation is expected to happen in the arm joint null space (i.e. the swivel angle). The primary hypothesis is that such an effort-based force field can induce a movement pattern change in an indirect manner. Secondarily, assuming that this adaptation may be further promoted through subtle prompts to explore the cost space, a variation of the approach with a progressive goal is also tested. Twenty naive subjects were allocated into two groups with slightly different implementations of the force field: one with a Constant Goal (CG) and another one with a Progressively changing Goal (PG). Subjects were asked to perform reaching tasks while attached to a 3D manipulandum. During the intervention, the device applied a resistive viscous force at the subject's hand as a function of the subject's swivel angle to encourage an increase of the latter. Significant increases of the swivel angle of 4.9° and 6.3° were observed for the CG and the PG groups respectively. This result confirms the feasibility of inducing motor adaptation in the redundant joint space by providing a task space intervention without explicit error feedback.
- 2 July 2021
- Published by Springer Nature
- p. 287-292
CANopen Robot Controller (CORC): An Open Software Stack for Human Robot Interaction Development
- 2 July 2021
- Published by Springer Nature
- p. 287-292
CANopen Robot Controller (CORC): An Open Software Stack for Human Robot Interaction Development
- 1 July 2020
- Published by Taylor & Francis in Disability and Rehabilitation: Assistive Technology
- Vol. 17 (5) , 531-538
Promoting clinical best practice in a user-centred design study of an upper limb rehabilitation robot
Purpose: Despite their promise to increase therapy intensity in neurorehabilitation, robotic devices have not yet seen mainstream adoption. Whilst there are a number of contributing factors, it is obvious that the treating clinician should have a clear understanding of the objectives and limitations of robotic device use. This study sought to explore how devices can be developed to support a clinician in providing clinical best practice. Methods and Materials: A user-centred design study of a robotic device was conducted, involving build-then-use iterations, where successive iterations are built based on feedback from the use cycle. This work reports results of an analysis of qualitative and quantitative data describing the use of the robotic device in the clinical sessions, and from a focus group with the treating clinicians. Results and Conclusions: The data indicated that use of the device did not result in patient goal-setting and may have resulted in poor movement quality. Therapists expected a higher level of autonomy from the robotic device, and this may have contributed to the above problems. These problems can and should be addressed through modification of both the study design and device to provide more explicit instructions to promote clinical best practice.
- 1 July 2020
- Published by Taylor & Francis in Disability and Rehabilitation: Assistive Technology
- Vol. 17 (5) , 531-538
Promoting clinical best practice in a user-centred design study of an upper limb rehabilitation robot
Purpose: Despite their promise to increase therapy intensity in neurorehabilitation, robotic devices have not yet seen mainstream adoption. Whilst there are a number of contributing factors, it is obvious that the treating clinician should have a clear understanding of the objectives and limitations of robotic device use. This study sought to explore how devices can be developed to support a clinician in providing clinical best practice. Methods and Materials: A user-centred design study of a robotic device was conducted, involving build-then-use iterations, where successive iterations are built based on feedback from the use cycle. This work reports results of an analysis of qualitative and quantitative data describing the use of the robotic device in the clinical sessions, and from a focus group with the treating clinicians. Results and Conclusions: The data indicated that use of the device did not result in patient goal-setting and may have resulted in poor movement quality. Therapists expected a higher level of autonomy from the robotic device, and this may have contributed to the above problems. These problems can and should be addressed through modification of both the study design and device to provide more explicit instructions to promote clinical best practice.
- 1 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 105-109
Direct versus Indirect Visual Feedback: the Effect of Technology in Neurorehabilitation
Visuomotor feedback and its impact on performing and learning movements is an extensively studied field, both through the use of experiments under different types of visuomotor feedback, as well as through neurophysiological studies. Neurorehabilitation of the upper-limb relies heavily on repetitive targeted movements and in recent decades, the introduction of instrumented and robotic devices coupled with computer screens have substituted the existing direct visual feedback of traditional practice with an indirect feedback. However, the impact of such a shift has not been studied.Putting in perspective the literature on these different aspects, this paper shows that there seems to be little indication that the feedback type may significantly affect the neurorehabilitation outcomes. Nevertheless, despite the intrinsic difficulties in directly observing the effects of the introduction of indirect visual feedback in neurorehabilitation practices, it is of interest to investigate further this specific aspect of the newly introduced technologies.
- 1 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 105-109
Direct versus Indirect Visual Feedback: the Effect of Technology in Neurorehabilitation
Visuomotor feedback and its impact on performing and learning movements is an extensively studied field, both through the use of experiments under different types of visuomotor feedback, as well as through neurophysiological studies. Neurorehabilitation of the upper-limb relies heavily on repetitive targeted movements and in recent decades, the introduction of instrumented and robotic devices coupled with computer screens have substituted the existing direct visual feedback of traditional practice with an indirect feedback. However, the impact of such a shift has not been studied.Putting in perspective the literature on these different aspects, this paper shows that there seems to be little indication that the feedback type may significantly affect the neurorehabilitation outcomes. Nevertheless, despite the intrinsic difficulties in directly observing the effects of the introduction of indirect visual feedback in neurorehabilitation practices, it is of interest to investigate further this specific aspect of the newly introduced technologies.
- 16 October 2018
- Published by Springer Nature
- p. 180-184
Sensorless Force Estimator in Rehabilitation Robotics
- 16 October 2018
- Published by Springer Nature
- p. 180-184
Sensorless Force Estimator in Rehabilitation Robotics
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2018, 2470-2474
Effect Of Arm Deweighting Using End-Effector Based Robotic Devices On Muscle Activity
Deweighting of the limb is commonly performed for patients with a neurological injury, such as stroke, as it allows these patients with limited muscle activity to perform movements. Deweighting has been implemented in exoskeletons and other multi-contact devices, but not on an end-effector based device with single contact point between the assisting robot and the human limb being assisted. This study inves-tigates the effects of deweighting using an end-effector based device on healthy subjects. The muscle activity of five subjects was measured in both static postures and dynamic movements. The results indicate a decrease in the activity of muscles which typically act against gravity - such as the anterior deltoid and the biceps brachii - but also suggest an increase in activity in muscles which act with gravity - such as the posterior deltoid and the lateral triceps. This can be explained by both the change in required muscle-generated torques and a conscious change in approach by the participants. These observations have implications for neurorehabilitation, particularly with respect to the muscle activation patterns which are trained through rehabilitation exercises.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2018, 2470-2474
Effect Of Arm Deweighting Using End-Effector Based Robotic Devices On Muscle Activity
Deweighting of the limb is commonly performed for patients with a neurological injury, such as stroke, as it allows these patients with limited muscle activity to perform movements. Deweighting has been implemented in exoskeletons and other multi-contact devices, but not on an end-effector based device with single contact point between the assisting robot and the human limb being assisted. This study inves-tigates the effects of deweighting using an end-effector based device on healthy subjects. The muscle activity of five subjects was measured in both static postures and dynamic movements. The results indicate a decrease in the activity of muscles which typically act against gravity - such as the anterior deltoid and the biceps brachii - but also suggest an increase in activity in muscles which act with gravity - such as the posterior deltoid and the lateral triceps. This can be explained by both the change in required muscle-generated torques and a conscious change in approach by the participants. These observations have implications for neurorehabilitation, particularly with respect to the muscle activation patterns which are trained through rehabilitation exercises.