Vega Pradana Rachim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Vega Pradana Rachim has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Sung-Min Park
Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), Pohang, South Korea
6 shared publications - Wan-Young Chung
Department of AI Convergence, Pukyong National University, Busan 48513, Republic of Korea
4 shared publications Jin-Hyeok Baek
School of Interdisciplinary Bioscience and Bioengineering, Pohang University of Science and Technology, Pohang, Republic of Korea
3 shared publications- Bongjin Lee
Department of Pediatrics, Seoul National University Hospital, Seoul, Republic of Korea
1 shared publication - Hee Chan Kim
Department of Biomedical Engineering, Seoul National University College of Medicine, Seoul, Republic of Korea
1 shared publication - Jaeseong Jang
HUINNO Company Ltd
1 shared publication
Latest Publications
- 27 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 30 (1) , 643-654
Enhanced Post-Prandial Glycemic Response Prediction in Type 2 Diabetes with Microbiome Data and Deep Learning
Nutritional intervention can improve glycemic control for type 2 diabetes mellitus (T2DM), and thus accurately predicting post-prandial glycemic responses (PPGRs) to each meal is essential. PPGRs can vary significantly between individuals, even when consuming the same foods, due to the diverse and complex nature of individual characteristics. However, to date, system-scale studies investigating the variability of PPGRs in people living with T2DM are scarce. This research collected meal logs, continuous glucose monitoring records, clinicodemographic profiles, and gut microbiota data comprising over 2,000 real-life meals across 88 individuals with T2DM, revealing causal relationships in the diet-microbiome-PPGR interplay. Furthermore, we developed a multimodal deep learning predictive PPGR model that integrates heterogeneous input data. The proposed model achieves R of 0.62 and 0.66 for 2- and 4-h PPGR prediction, respectively, significantly surpassing the perfor-mance of the carbohydrate single predictor and state-of-the-art machine learning algorithms. This model substantially improved the prediction in the subgroup of low responders to carbohydrates, a traditionally challenging population for accurate prediction using carbohydrate-based methods. This advancement empowers personalized PPGR prediction, laying the foundation for precision nutrition and better glycemic management for individuals with T2DM.
- 27 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 30 (1) , 643-654
Enhanced Post-Prandial Glycemic Response Prediction in Type 2 Diabetes with Microbiome Data and Deep Learning
Nutritional intervention can improve glycemic control for type 2 diabetes mellitus (T2DM), and thus accurately predicting post-prandial glycemic responses (PPGRs) to each meal is essential. PPGRs can vary significantly between individuals, even when consuming the same foods, due to the diverse and complex nature of individual characteristics. However, to date, system-scale studies investigating the variability of PPGRs in people living with T2DM are scarce. This research collected meal logs, continuous glucose monitoring records, clinicodemographic profiles, and gut microbiota data comprising over 2,000 real-life meals across 88 individuals with T2DM, revealing causal relationships in the diet-microbiome-PPGR interplay. Furthermore, we developed a multimodal deep learning predictive PPGR model that integrates heterogeneous input data. The proposed model achieves R of 0.62 and 0.66 for 2- and 4-h PPGR prediction, respectively, significantly surpassing the perfor-mance of the carbohydrate single predictor and state-of-the-art machine learning algorithms. This model substantially improved the prediction in the subgroup of low responders to carbohydrates, a traditionally challenging population for accurate prediction using carbohydrate-based methods. This advancement empowers personalized PPGR prediction, laying the foundation for precision nutrition and better glycemic management for individuals with T2DM.
- 19 February 2025
- Published by Elsevier in Expert Systems with Applications
- Vol. 274
Generalized reinforcement learning control algorithm for fully automated insulin delivery system
- 19 February 2025
- Published by Elsevier in Expert Systems with Applications
- Vol. 274
Generalized reinforcement learning control algorithm for fully automated insulin delivery system
- 31 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (20) , 32444-32454
Cuffless Blood Pressure Estimation Model Using Clustering Techniques
This study introduces a clustered algorithm for estimating blood pressure (BP) using electrocardiographic and photoplethysmographic data obtained from 1675 subjects, corresponding to a total of 1051462 cardiac cycles. These data were sourced from the publicly accessible biosignal database, VitalDB. To enable the application of pulse wave analysis (PWA) on the recorded signals, the study extracted 29 morphological features from these signals and employed the K-means clustering algorithm to categorize them into six distinct clusters. Each of these clusters was used to train and optimize three separate BP estimation algorithms. Notably, the Shapley additive explanations analysis identified arterial stiffness and peripheral resistance as the most influential factors contributing to the clustering process. Experimental results reveal that the most accurate BP estimation model achieves deviations of 0.043 ± 6.43 mmHg for systolic BP and 0.052 ± 3.65 mmHg for diastolic BP. Remarkably, the adoption of clustering lead to notable enhancements in accuracy across key metrics, including mean error, standard deviation, and mean absolute error estimates. Importantly, these improvements align with the rigorous criteria established by three international BP standards: the Association for the Advancement of Medical Instrumentation/ISO, the British Hypertension Society, and the Institution of Electrical and Electronic Engineers. This study underscores the potential for clinical adoption of the clustering-based, cuffless BP estimation algorithm, which accommodates individual variations without necessitating a pretraining process for the subjects under investigation.
- 31 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (20) , 32444-32454
Cuffless Blood Pressure Estimation Model Using Clustering Techniques
This study introduces a clustered algorithm for estimating blood pressure (BP) using electrocardiographic and photoplethysmographic data obtained from 1675 subjects, corresponding to a total of 1051462 cardiac cycles. These data were sourced from the publicly accessible biosignal database, VitalDB. To enable the application of pulse wave analysis (PWA) on the recorded signals, the study extracted 29 morphological features from these signals and employed the K-means clustering algorithm to categorize them into six distinct clusters. Each of these clusters was used to train and optimize three separate BP estimation algorithms. Notably, the Shapley additive explanations analysis identified arterial stiffness and peripheral resistance as the most influential factors contributing to the clustering process. Experimental results reveal that the most accurate BP estimation model achieves deviations of 0.043 ± 6.43 mmHg for systolic BP and 0.052 ± 3.65 mmHg for diastolic BP. Remarkably, the adoption of clustering lead to notable enhancements in accuracy across key metrics, including mean error, standard deviation, and mean absolute error estimates. Importantly, these improvements align with the rigorous criteria established by three international BP standards: the Association for the Advancement of Medical Instrumentation/ISO, the British Hypertension Society, and the Institution of Electrical and Electronic Engineers. This study underscores the potential for clinical adoption of the clustering-based, cuffless BP estimation algorithm, which accommodates individual variations without necessitating a pretraining process for the subjects under investigation.
- Open Access
- 10 July 2023
- Published by Springer Nature in npj Flexible Electronics
- Vol. 7 (1) , 1-12
Real-time multiaxial strain mapping using computer vision integrated optical sensors
Soft strain sensors pose great potential for emerging human–machine interfaces. However, their real-world applications have been limited due to challenges such as low reproducibility, susceptibility to environmental noise, and short lifetimes, which are attributed to nanotechnologies, including microfabrication techniques. In this study, we present a computer vision-based optical strain (CVOS) sensor system that integrates computer vision with streamlined microfabrication techniques to overcome these challenges and facilitate real-time multiaxial strain mapping. The proposed CVOS sensor consists of an easily fabricated soft silicone substrate with micro-markers and a tiny camera for highly sensitive marker detection. Real-time multiaxial strain mapping allows for measuring and distinguishing complex multi-directional strain patterns, providing the proposed CVOS sensor with higher scalability. Our results indicate that the proposed CVOS sensor is a promising approach for the development of highly sensitive and versatile human–machine interfaces that can operate long-term under real-world conditions.
- 10 July 2023
- Published by Springer Nature in npj Flexible Electronics
- Vol. 7 (1) , 1-12
Open AccessReal-time multiaxial strain mapping using computer vision integrated optical sensors
Soft strain sensors pose great potential for emerging human–machine interfaces. However, their real-world applications have been limited due to challenges such as low reproducibility, susceptibility to environmental noise, and short lifetimes, which are attributed to nanotechnologies, including microfabrication techniques. In this study, we present a computer vision-based optical strain (CVOS) sensor system that integrates computer vision with streamlined microfabrication techniques to overcome these challenges and facilitate real-time multiaxial strain mapping. The proposed CVOS sensor consists of an easily fabricated soft silicone substrate with micro-markers and a tiny camera for highly sensitive marker detection. Real-time multiaxial strain mapping allows for measuring and distinguishing complex multi-directional strain patterns, providing the proposed CVOS sensor with higher scalability. Our results indicate that the proposed CVOS sensor is a promising approach for the development of highly sensitive and versatile human–machine interfaces that can operate long-term under real-world conditions.
- Open Access
- 17 May 2022
- Published by Wiley in Advanced Materials Technologies
- Vol. 7 (11)
A Scalable Laser‐Centric Fabrication of an Epidermal Cardiopulmonary Patch
Recent advances in scalable fabrication methods based on printing technologies have improved the yield and lowered the cost of manufacturing epidermal sensors. However, modern technologies still require expensive multi‐bio‐ink raw materials. A laser‐centric fabrication method that realizes a cost‐effective, scalable, and streamlined fabrication process with easily used material and equipment is reported. The fabricated epidermal patch can quickly respond to the demands of personalized models. Here, the epidermal sensor patch is applied to continuous monitoring of the human cardiopulmonary system. The sensor performs conventional bio‐signal monitoring but is also extendible to other monitoring forms. The patch provides enhanced functions through its gas‐permeable and skin‐adhesive microporous layer and its stretchable, conformal, and biocompatible multimodal sensing layer. The utility of the proposed sensor patch in clinical diagnosis in a mobile healthcare environment is demonstrated in multiple bio‐signal‐morphology analyses.
- 17 May 2022
- Published by Wiley in Advanced Materials Technologies
- Vol. 7 (11)
Open AccessA Scalable Laser‐Centric Fabrication of an Epidermal Cardiopulmonary Patch
Recent advances in scalable fabrication methods based on printing technologies have improved the yield and lowered the cost of manufacturing epidermal sensors. However, modern technologies still require expensive multi‐bio‐ink raw materials. A laser‐centric fabrication method that realizes a cost‐effective, scalable, and streamlined fabrication process with easily used material and equipment is reported. The fabricated epidermal patch can quickly respond to the demands of personalized models. Here, the epidermal sensor patch is applied to continuous monitoring of the human cardiopulmonary system. The sensor performs conventional bio‐signal monitoring but is also extendible to other monitoring forms. The patch provides enhanced functions through its gas‐permeable and skin‐adhesive microporous layer and its stretchable, conformal, and biocompatible multimodal sensing layer. The utility of the proposed sensor patch in clinical diagnosis in a mobile healthcare environment is demonstrated in multiple bio‐signal‐morphology analyses.
- 16 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (8) , 10132-10142
Unobtrusive, Cuffless Blood Pressure Monitoring Using a Soft Polymer Sensor Array With Flexible Hybrid Electronics
The state-of-the-art systems for blood pressure (BP) monitoring often use cuffed-based rigid sensory systems, bulky electronics, multiple measurement sites, and intermittent measurement. Here, we introduce a new type of epidermal electronics that were specifically designed for cuffless BP-monitoring system, named multiPANI. The proposed fully integrated wearable device is equipped with a wireless-flexible hybrid electronics, a personalized flexible sensor array, and encapsulated with a thin biocompatible elastomer layer for soft-conformal contact with the complex skin surface structure. In addition, a unique capability of multiPANI to monitor multiple local pulse wave velocity (PWV) enabling us to develop a novel hybrid BP estimation algorithm that combine a selective-local PWV and high-signal-to-noise-ratio-based pulse wave analysis (PWA) for robust-cuffless BP-monitoring system. Experimental results indicate that the proposed hybrid selective PWV-PWA BP model outperform the typical single-PWV BP model by ~30%, with an acceptable root-mean-square-error performance of 3.94 ± 0.5 and 1.88 ± 0.9 mmHg, for systolic BP and diastolic BP respectively. Collectively, this study demonstrated a unique solution of fully integrated epidermal electronics and hybrid BP estimation algorithm for a robust, cuffless, and long-term BP monitoring.
- 16 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (8) , 10132-10142
Unobtrusive, Cuffless Blood Pressure Monitoring Using a Soft Polymer Sensor Array With Flexible Hybrid Electronics
The state-of-the-art systems for blood pressure (BP) monitoring often use cuffed-based rigid sensory systems, bulky electronics, multiple measurement sites, and intermittent measurement. Here, we introduce a new type of epidermal electronics that were specifically designed for cuffless BP-monitoring system, named multiPANI. The proposed fully integrated wearable device is equipped with a wireless-flexible hybrid electronics, a personalized flexible sensor array, and encapsulated with a thin biocompatible elastomer layer for soft-conformal contact with the complex skin surface structure. In addition, a unique capability of multiPANI to monitor multiple local pulse wave velocity (PWV) enabling us to develop a novel hybrid BP estimation algorithm that combine a selective-local PWV and high-signal-to-noise-ratio-based pulse wave analysis (PWA) for robust-cuffless BP-monitoring system. Experimental results indicate that the proposed hybrid selective PWV-PWA BP model outperform the typical single-PWV BP model by ~30%, with an acceptable root-mean-square-error performance of 3.94 ± 0.5 and 1.88 ± 0.9 mmHg, for systolic BP and diastolic BP respectively. Collectively, this study demonstrated a unique solution of fully integrated epidermal electronics and hybrid BP estimation algorithm for a robust, cuffless, and long-term BP monitoring.
- Open Access
- 28 May 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 7947
Multimodal Wrist Biosensor for Wearable Cuff-less Blood Pressure Monitoring System
We propose a multimodal biosensor for use in continuous blood pressure (BP) monitoring system. Our proposed novel configuration measures photo-plethysmography (PPG) and impedance plethysmography (IPG) signals simultaneously from the subject wrist. The proposed biosensor system enables a fully non-intrusive system that is cuff-less, also utilize a single measurement site for maximum wearability and convenience of the patients. The efficacy of the proposed technique was evaluated on 10 young healthy subjects. Experimental results indicate that the pulse transit time (PTT)-based features calculated from an IPG peak and PPG maximum second derivative (f14) had a relatively high correlation coefficient (r) to the reference BP, with −0.81 ± 0.08 and −0.78 ± 0.09 for systolic BP (SBP) and diastolic BP (DBP), respectively. Moreover, here we proposed two BP estimation models that utilize six- and one-point calibration models. The six-point model is based on the PTT, whereas the one-point model is based on the combined PTT and radial impedance (Z). Thus, in both models, we observed an adequate root-mean-square-error estimation performance, with 4.20 ± 1.66 and 2.90 ± 0.90 for SBP and DBP, respectively, with the PTT BP model; and 6.86 ± 1.65 and 6.67 ± 1.75 for SBP and DBP, respectively, with the PTT-Z BP model. This study suggests the possibility of estimating a subject’s BP from only wrist bio-signals. Thus, the six- and one-point PTT-Z calibration models offer adequate performance for practical applications.
- 28 May 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 7947
Open AccessMultimodal Wrist Biosensor for Wearable Cuff-less Blood Pressure Monitoring System
We propose a multimodal biosensor for use in continuous blood pressure (BP) monitoring system. Our proposed novel configuration measures photo-plethysmography (PPG) and impedance plethysmography (IPG) signals simultaneously from the subject wrist. The proposed biosensor system enables a fully non-intrusive system that is cuff-less, also utilize a single measurement site for maximum wearability and convenience of the patients. The efficacy of the proposed technique was evaluated on 10 young healthy subjects. Experimental results indicate that the pulse transit time (PTT)-based features calculated from an IPG peak and PPG maximum second derivative (f14) had a relatively high correlation coefficient (r) to the reference BP, with −0.81 ± 0.08 and −0.78 ± 0.09 for systolic BP (SBP) and diastolic BP (DBP), respectively. Moreover, here we proposed two BP estimation models that utilize six- and one-point calibration models. The six-point model is based on the PTT, whereas the one-point model is based on the combined PTT and radial impedance (Z). Thus, in both models, we observed an adequate root-mean-square-error estimation performance, with 4.20 ± 1.66 and 2.90 ± 0.90 for SBP and DBP, respectively, with the PTT BP model; and 6.86 ± 1.65 and 6.67 ± 1.75 for SBP and DBP, respectively, with the PTT-Z BP model. This study suggests the possibility of estimating a subject’s BP from only wrist bio-signals. Thus, the six- and one-point PTT-Z calibration models offer adequate performance for practical applications.
- Top Cited Papers
- 1 May 2019
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 286, 173-180
Wearable-band type visible-near infrared optical biosensor for non-invasive blood glucose monitoring
- 1 May 2019
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 286, 173-180
Top Cited PapersWearable-band type visible-near infrared optical biosensor for non-invasive blood glucose monitoring
- 28 February 2019
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (5) , 7568-7584
High-accuracy VLC-based indoor positioning system using multi-level modulation
In this study, a novel high-precision positioning algorithm was proposed by using Visible Light Communication (VLC) with only a simple and single receiver. The received voltage-level difference with multi-level modulation was adopted as the input variable, in order to minimize the negative consequences of noise. Then, the relationship between the received voltage-level difference, noise, and position was developed based on the optical propagation model. The minimum mean squares error algorithm and extended-Kalman filter was employed in order to improve the accuracy of the optical model and achieve high performance. Using the developed algorithm, high-accuracy results with a 0.9 cm average position error in the simulation and 2.56 cm average position error in the practical experiments were obtained.
- 28 February 2019
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (5) , 7568-7584
High-accuracy VLC-based indoor positioning system using multi-level modulation
In this study, a novel high-precision positioning algorithm was proposed by using Visible Light Communication (VLC) with only a simple and single receiver. The received voltage-level difference with multi-level modulation was adopted as the input variable, in order to minimize the negative consequences of noise. Then, the relationship between the received voltage-level difference, noise, and position was developed based on the optical propagation model. The minimum mean squares error algorithm and extended-Kalman filter was employed in order to improve the accuracy of the optical model and achieve high performance. Using the developed algorithm, high-accuracy results with a 0.9 cm average position error in the simulation and 2.56 cm average position error in the practical experiments were obtained.
- 6 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 30 (10) , 903-906
Multilevel Intensity-Modulation for Rolling Shutter-Based Optical Camera Communication
High data transmission rates are desirable in an optical camera communication (OCC) system. In order to achieve this, a novel multilevel-intensity modulation (m-IM) scheme for a rolling-shutter (RS)-based OCC is introduced in this letter. The proposed multilevel intensity signal is obtained by transmitting the signal pulse time faster than the camera shutter speed, where the shutter speed is highly dependent on the camera exposure time and the RS-effect of CMOS-image sensor of the camera. In addition, pulse width modulation is also used on the transmitter side to control the output intensity (signal pulse) of the LED transmitter. As the optical signal is received wirelessly by the camera, we further propose a novel smartphone-based digital demodulation algorithm for our RS-based OCC system. In this letter, we compare the performance of the proposed system to a typical modulation scheme for OCC system, such as ON-OFF keying. Moreover, an intensive performance test is conducted for different symbol times to determine their relationship to bit error rate and achieved data rate. A data transmission rate >10 kbps over a range of up to 2 m by using a 30 fps smartphone camera can be achieved by using our proposed 4-IM in our proposed scheme.
- 6 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 30 (10) , 903-906
Multilevel Intensity-Modulation for Rolling Shutter-Based Optical Camera Communication
High data transmission rates are desirable in an optical camera communication (OCC) system. In order to achieve this, a novel multilevel-intensity modulation (m-IM) scheme for a rolling-shutter (RS)-based OCC is introduced in this letter. The proposed multilevel intensity signal is obtained by transmitting the signal pulse time faster than the camera shutter speed, where the shutter speed is highly dependent on the camera exposure time and the RS-effect of CMOS-image sensor of the camera. In addition, pulse width modulation is also used on the transmitter side to control the output intensity (signal pulse) of the LED transmitter. As the optical signal is received wirelessly by the camera, we further propose a novel smartphone-based digital demodulation algorithm for our RS-based OCC system. In this letter, we compare the performance of the proposed system to a typical modulation scheme for OCC system, such as ON-OFF keying. Moreover, an intensive performance test is conducted for different symbol times to determine their relationship to bit error rate and achieved data rate. A data transmission rate >10 kbps over a range of up to 2 m by using a 30 fps smartphone camera can be achieved by using our proposed 4-IM in our proposed scheme.