Roman S. Voronov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Roman S. Voronov has a total of 101 co-authors. Here are the top co-authors by number of shared publications:
- Dimitrios Vassilios Papavassiliou
School of Sustainable Chemical, Biological, and Materials Engineering, University of Oklahoma, Norman, Oklahoma 73019-1004, USA
11 shared publications - Anh Tong
Otto H. York Department of Chemical and Materials Engineering, New Jersey Institute of Technology Newark College of Engineering 1 , 161 Warren Street, Newark, New Jersey 07102, USA
6 shared publications Vassilios I. Sikavitsas
Stephenson School of Biomedical Engineering, The University of Oklahoma, 202 W. Boyd Carson Engineering Center, Room 107, Norman, OK 73019, USA
6 shared publicationsMigle Surblyte
Ying Wu College of Computing Sciences, Department of Computer Science, New Jersey Institute of Technology, Newark, NJ 07102, USA
5 shared publicationsQuang Long Pham
The Otto H. York Department of Chemical and Materials Engineering, New Jersey Institute of Technology Newark College of Engineering, Newark, NJ, USA
5 shared publicationsSamuel B. VanGordon
School of Chemical, Biological and Materials Engineering, The University of Oklahoma, Norman, Oklahoma
5 shared publications
Latest Publications
- Open Access
- 29 October 2026
- Published by Open Engineering Inc in engrXiv
Fabrication of Three-Dimensionally Addressable Microfluidic Plumbing by Stereolithographic 3D Printing
Cell cultures thicker than a few hundred micrometers are hard to feed, because nothing circulates inside them. They are also hard to analyze without destroying them, and hard to correct once the cells are inside. Our group previously answered those three problems for flat cultures with an automated microfluidic device in which a computer opens any one of a grid of ports on its own, an ability we call addressable, to deliver or withdraw cells and chemicals at chosen locations inside one living culture. Here we extend that addressable plumbing to a three-dimensional scaffold, a lattice of culture chambers, designed to be built in one piece by 3D printing. Every chamber has an inlet and an outlet channel on each of the three axes, and those channels are the chamber's ports. Each inlet-outlet pair carries a valve at the chamber's mouth on either side and a bypass channel that joins the two channels around the chamber. Closing the two valves on an axis sends flow along that axis through the bypass, and opening them admits it into the chamber. Fluid carrying cells or chemicals can therefore travel along a row of chambers to any one of them without entering, or disturbing, the chambers before it. Prior addressable layouts either confine such transfers to one row or leave every other column of chambers empty to serve as the detour. We also place valves on the bypasses themselves. With a bypass closed and a chamber opened toward its neighbor, the two chambers exchange molecules and cells by diffusion while the rest of the lattice stays isolated, so one device can run as a single interconnected culture, as isolated wells, or as isolated sub-volumes. A combinatorial multiplexer, a valve matrix that opens one of many lines from a few control lines, is designed to drive the lattice's valve lines from a handful of external pneumatic solenoids. We then printed the building block of the lattice, one port with its valves, as a single part on a commercial stereolithographic printer, and then one complete unit module as a single cube. Two of the block's valves stand in orientations that, to our knowledge, no one had printed before: a valve whose membrane is printed standing vertically rather than flat on the build plate, and a valve whose control pressure arrives perpendicular to the membrane rather than along it. We expected each to fail, the first by splitting along the seams between print layers and the second by tearing at the center of the membrane, and flow simulations confirmed the second cause. We removed both causes by geometry: the channel that brings the control pressure now enters at the sides of the membrane rather than its center, and a reinforcement whose layer seams are offset from the membrane's backs the vertical membrane. Valves printed with those changes sealed and opened under pneumatic control. The scaffold is built for patterned co-cultures of osteoblasts and chondrocytes monitored through their own ports, and we will report that application in a later version of this preprint.
- 29 October 2026
- Published by Open Engineering Inc in engrXiv
Open AccessFabrication of Three-Dimensionally Addressable Microfluidic Plumbing by Stereolithographic 3D Printing
Cell cultures thicker than a few hundred micrometers are hard to feed, because nothing circulates inside them. They are also hard to analyze without destroying them, and hard to correct once the cells are inside. Our group previously answered those three problems for flat cultures with an automated microfluidic device in which a computer opens any one of a grid of ports on its own, an ability we call addressable, to deliver or withdraw cells and chemicals at chosen locations inside one living culture. Here we extend that addressable plumbing to a three-dimensional scaffold, a lattice of culture chambers, designed to be built in one piece by 3D printing. Every chamber has an inlet and an outlet channel on each of the three axes, and those channels are the chamber's ports. Each inlet-outlet pair carries a valve at the chamber's mouth on either side and a bypass channel that joins the two channels around the chamber. Closing the two valves on an axis sends flow along that axis through the bypass, and opening them admits it into the chamber. Fluid carrying cells or chemicals can therefore travel along a row of chambers to any one of them without entering, or disturbing, the chambers before it. Prior addressable layouts either confine such transfers to one row or leave every other column of chambers empty to serve as the detour. We also place valves on the bypasses themselves. With a bypass closed and a chamber opened toward its neighbor, the two chambers exchange molecules and cells by diffusion while the rest of the lattice stays isolated, so one device can run as a single interconnected culture, as isolated wells, or as isolated sub-volumes. A combinatorial multiplexer, a valve matrix that opens one of many lines from a few control lines, is designed to drive the lattice's valve lines from a handful of external pneumatic solenoids. We then printed the building block of the lattice, one port with its valves, as a single part on a commercial stereolithographic printer, and then one complete unit module as a single cube. Two of the block's valves stand in orientations that, to our knowledge, no one had printed before: a valve whose membrane is printed standing vertically rather than flat on the build plate, and a valve whose control pressure arrives perpendicular to the membrane rather than along it. We expected each to fail, the first by splitting along the seams between print layers and the second by tearing at the center of the membrane, and flow simulations confirmed the second cause. We removed both causes by geometry: the channel that brings the control pressure now enters at the sides of the membrane rather than its center, and a reinforcement whose layer seams are offset from the membrane's backs the vertical membrane. Valves printed with those changes sealed and opened under pneumatic control. The scaffold is built for patterned co-cultures of osteoblasts and chondrocytes monitored through their own ports, and we will report that application in a later version of this preprint.
- Open Access
- 26 September 2026
- Published by Open Engineering Inc in engrXiv
Cross-Section and Top-View Image-Analysis Pipelines for Automated Characterization of 3D-Printed Microfluidic Channels and Valves
Printing a microfluidic device in one piece encloses its channels and valve membranes inside a solid body, where inspection from the outside cannot easily tell whether a channel formed or how far a membrane moves. In a companion study we built a design framework for printed membrane valves that rests on measurements taken from micrographs of purpose-built test devices. Here we report the imaging methods and the three open-source analysis programs that produce those measurements. Two of the programs analyze cross-section views, in which the microscope looks along each channel through its open end while light shines through the device from behind. In that view an open channel appears as a bright window, and a blocked channel or a deflected membrane darkens it. A general-purpose segmentation model (the Segment Anything Model) outlines candidate channel regions without task-specific training. A sequence of classical image tests then decides which candidate is the channel. The first cross-section program classifies each channel as open, occluded, or not formed and measures how far the channel roof sags. The second compares images of each valve before and after pressurization and fits a circular arc to the edge of the membrane to measure how far the membrane reaches into the channel. A set of quality checks turns an unreliable reach measurement into missing data rather than a false zero. The third program, still under development, analyzes top views taken through the transparent resin. The top-view program tracks both walls of every channel along its full length and classifies each channel as formed, narrowed, pinched closed, or not formed. Applied to 112 top views, it located narrowings and closures partway along channels, which a cross-section at the channel end cannot show, and it agreed with an expert on 17 of 24 reviewed channels. Each program also writes a diagnostic figure for every automated decision.
- 26 September 2026
- Published by Open Engineering Inc in engrXiv
Open AccessCross-Section and Top-View Image-Analysis Pipelines for Automated Characterization of 3D-Printed Microfluidic Channels and Valves
Printing a microfluidic device in one piece encloses its channels and valve membranes inside a solid body, where inspection from the outside cannot easily tell whether a channel formed or how far a membrane moves. In a companion study we built a design framework for printed membrane valves that rests on measurements taken from micrographs of purpose-built test devices. Here we report the imaging methods and the three open-source analysis programs that produce those measurements. Two of the programs analyze cross-section views, in which the microscope looks along each channel through its open end while light shines through the device from behind. In that view an open channel appears as a bright window, and a blocked channel or a deflected membrane darkens it. A general-purpose segmentation model (the Segment Anything Model) outlines candidate channel regions without task-specific training. A sequence of classical image tests then decides which candidate is the channel. The first cross-section program classifies each channel as open, occluded, or not formed and measures how far the channel roof sags. The second compares images of each valve before and after pressurization and fits a circular arc to the edge of the membrane to measure how far the membrane reaches into the channel. A set of quality checks turns an unreliable reach measurement into missing data rather than a false zero. The third program, still under development, analyzes top views taken through the transparent resin. The top-view program tracks both walls of every channel along its full length and classifies each channel as formed, narrowed, pinched closed, or not formed. Applied to 112 top views, it located narrowings and closures partway along channels, which a cross-section at the channel end cannot show, and it agreed with an expert on 17 of 24 reviewed channels. Each program also writes a diagnostic figure for every automated decision.
- Open Access
- 14 September 2026
- Published by Open Engineering Inc in engrXiv
A Geometry-First Design Framework and Interactive Design Tool for 3D-Printed Microfluidic Valves Using New Photopolymer Resins
Microfluidic valves are essential for routing, isolation, and automation in integrated microfluidic systems, yet they remain difficult to fabricate in 3D-printed workflows: a functional valve requires a thin, pressure-responsive membrane within an otherwise rigid monolithic print — a combination that vendor datasheets do not predict. With no consensus material for 3D-printed microfluidics and new resins appearing continually, valve development devolves into blind trial-and-error across a large space of printer settings and geometric parameters. We present a geometry-first framework that establishes valve feasibility for newly adopted photopolymer resins without mechanical property data or iterative guesswork. Using the commercial resin FunToDo NanoClear, we map enclosed-channel printability bounds, identify membrane thickness–width limits, quantify membrane reach — how far the actuated membrane travels toward the channel floor — with an automated image-analysis pipeline, and prescribe the sealing geometry through an interactive design tool. A single measured constant — the membrane deflection coefficient κ — links these steps, and the closure model underlying the tool is purely geometric and therefore independent of fabrication route. Functional testing validates the framework: tool-prescribed valve seats decouple sealing from channel width, and the optimized valves block flow completely, tolerate control pressures up to 60 psi, and sustain one million open/close actuation cycles at all but the widest tested channel width — matching the highest lifetime reported for a 3D-printed membrane valve, previously achieved only with custom in-house resin formulations, here obtained with an off-the-shelf commercial material. The framework also generated a previously unreported squeeze-valve redesign in which two mirrored spherical-cap seats, prescribed by the same κ, guide opposed floor and ceiling membranes to closure. Its generality was reaffirmed by producing valves from Asiga Dental IBT, a dental resin never before used for microfluidics, and the valves were integrated into device-level demonstrations including multi-way flow routing and an on-chip pump.
- 14 September 2026
- Published by Open Engineering Inc in engrXiv
Open AccessA Geometry-First Design Framework and Interactive Design Tool for 3D-Printed Microfluidic Valves Using New Photopolymer Resins
Microfluidic valves are essential for routing, isolation, and automation in integrated microfluidic systems, yet they remain difficult to fabricate in 3D-printed workflows: a functional valve requires a thin, pressure-responsive membrane within an otherwise rigid monolithic print — a combination that vendor datasheets do not predict. With no consensus material for 3D-printed microfluidics and new resins appearing continually, valve development devolves into blind trial-and-error across a large space of printer settings and geometric parameters. We present a geometry-first framework that establishes valve feasibility for newly adopted photopolymer resins without mechanical property data or iterative guesswork. Using the commercial resin FunToDo NanoClear, we map enclosed-channel printability bounds, identify membrane thickness–width limits, quantify membrane reach — how far the actuated membrane travels toward the channel floor — with an automated image-analysis pipeline, and prescribe the sealing geometry through an interactive design tool. A single measured constant — the membrane deflection coefficient κ — links these steps, and the closure model underlying the tool is purely geometric and therefore independent of fabrication route. Functional testing validates the framework: tool-prescribed valve seats decouple sealing from channel width, and the optimized valves block flow completely, tolerate control pressures up to 60 psi, and sustain one million open/close actuation cycles at all but the widest tested channel width — matching the highest lifetime reported for a 3D-printed membrane valve, previously achieved only with custom in-house resin formulations, here obtained with an off-the-shelf commercial material. The framework also generated a previously unreported squeeze-valve redesign in which two mirrored spherical-cap seats, prescribed by the same κ, guide opposed floor and ceiling membranes to closure. Its generality was reaffirmed by producing valves from Asiga Dental IBT, a dental resin never before used for microfluidics, and the valves were integrated into device-level demonstrations including multi-way flow routing and an on-chip pump.
- Open Access
- 30 May 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (6) , 657
Common Food-Wrap Film as a Cost-Effective and Readily Available Alternative to Thermoplastic Polyurethane (TPU) Membranes for Microfluidic On-Chip Valves and Pumps
Microfluidic devices rely on precise fluid control to enable complex operations in diagnostics, chemical synthesis, and biological research. Central to this control are microvalves, which regulate on-chip flow but require flexible membranes for active operation. While the laser cutting of thermoplastics offers a fast, automated method for fabricating rigid microfluidic components, integrating flexible elements like valves and pumps remains a key challenge. Thermoplastic polyurethane (TPU) membranes have been adopted to address this need but are costly and difficult to procure reliably. In this study, we present commercial food-wrap film (FWF) as a low-cost, widely available alternative membrane material. We demonstrate FWF’s compatibility with laser-cut thermoplastic microfluidic devices by successfully fabricating Quake-style valves and peristaltic pumps. FWF valves maintained reliable sealing at 40 psi, maintained stable flow rates of ~1.33 μL/min during peristaltic operation, and sustained over one million continuous actuation cycles without performance degradation. Burst pressure testing confirmed robustness up to 60 psi. Additionally, FWF’s thermal resistance up to 140 °C enabled effective thermal bonding with PMMA layers, simplifying device assembly. These results establish FWF as a viable substitute for TPU membranes, offering an accessible and scalable solution for microfluidic device fabrication, particularly in resource-limited settings where TPU availability is constrained.
- 30 May 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (6) , 657
Open AccessCommon Food-Wrap Film as a Cost-Effective and Readily Available Alternative to Thermoplastic Polyurethane (TPU) Membranes for Microfluidic On-Chip Valves and Pumps
Microfluidic devices rely on precise fluid control to enable complex operations in diagnostics, chemical synthesis, and biological research. Central to this control are microvalves, which regulate on-chip flow but require flexible membranes for active operation. While the laser cutting of thermoplastics offers a fast, automated method for fabricating rigid microfluidic components, integrating flexible elements like valves and pumps remains a key challenge. Thermoplastic polyurethane (TPU) membranes have been adopted to address this need but are costly and difficult to procure reliably. In this study, we present commercial food-wrap film (FWF) as a low-cost, widely available alternative membrane material. We demonstrate FWF’s compatibility with laser-cut thermoplastic microfluidic devices by successfully fabricating Quake-style valves and peristaltic pumps. FWF valves maintained reliable sealing at 40 psi, maintained stable flow rates of ~1.33 μL/min during peristaltic operation, and sustained over one million continuous actuation cycles without performance degradation. Burst pressure testing confirmed robustness up to 60 psi. Additionally, FWF’s thermal resistance up to 140 °C enabled effective thermal bonding with PMMA layers, simplifying device assembly. These results establish FWF as a viable substitute for TPU membranes, offering an accessible and scalable solution for microfluidic device fabrication, particularly in resource-limited settings where TPU availability is constrained.
- Open Access
- 2 January 2025
- Published by Open Engineering Inc in engrXiv
Geometrical Modifications for Reliable 3D Printing of Microvalves in Multi-Plane Microfluidic Devices
Three-dimensional (3D) printing has emerged as a transformative technology for fabricating complex microfluidic devices, enabling features that were previously unattainable with traditional layer-by-layer soft lithography. One key challenge in advancing 3D-printed microfluidics is the integration of functional microvalves across multiple spatial orientations. This study explores the design, simulation, and experimental realization of novel microvalve configurations to overcome the limitations of conventional, single-plane valves. We hypothesize that non-traditional valve orientations, such as those with vertically printed membranes or perpendicular control channels, present unique fabrication and operational challenges, including membrane delamination and stress-induced failure. To address these issues, we developed optimized geometries and fabrication techniques, supported by computational fluid dynamics (CFD) simulations to predict and mitigate stress concentrations. Our results demonstrate successful implementation of previously unreported valve configurations, validated through pressure testing and flow control experiments. These advancements expand the versatility of 3D-printed microfluidic systems, paving the way for more robust and adaptable devices in biomedical, chemical, and environmental applications.
- 2 January 2025
- Published by Open Engineering Inc in engrXiv
Open AccessGeometrical Modifications for Reliable 3D Printing of Microvalves in Multi-Plane Microfluidic Devices
Three-dimensional (3D) printing has emerged as a transformative technology for fabricating complex microfluidic devices, enabling features that were previously unattainable with traditional layer-by-layer soft lithography. One key challenge in advancing 3D-printed microfluidics is the integration of functional microvalves across multiple spatial orientations. This study explores the design, simulation, and experimental realization of novel microvalve configurations to overcome the limitations of conventional, single-plane valves. We hypothesize that non-traditional valve orientations, such as those with vertically printed membranes or perpendicular control channels, present unique fabrication and operational challenges, including membrane delamination and stress-induced failure. To address these issues, we developed optimized geometries and fabrication techniques, supported by computational fluid dynamics (CFD) simulations to predict and mitigate stress concentrations. Our results demonstrate successful implementation of previously unreported valve configurations, validated through pressure testing and flow control experiments. These advancements expand the versatility of 3D-printed microfluidic systems, paving the way for more robust and adaptable devices in biomedical, chemical, and environmental applications.
- Open Access
- 29 May 2023
- Published by Elsevier in SLAS Technology
- Vol. 28 (3) , 101
Bioprinting the future
- 29 May 2023
- Published by Elsevier in SLAS Technology
- Vol. 28 (3) , 101
Open AccessBioprinting the future
- 1 March 2023
- Published by AIP Publishing in Biomicrofluidics
- Vol. 17 (2) , 024103
Addressable microfluidics technology for non-sacrificial analysis of biomaterial implants in vivo
Tissue regeneration-promoting and drug-eluting biomaterials are commonly implanted into animals as a part of late-stage testing before committing to human trials required by the government. Because the trials are very expensive (e.g., they can cost over a billion U.S. dollars), it is critical for companies to have the best possible characterization of the materials' safety and efficacy before it goes into a human. However, the conventional approaches to biomaterial evaluation necessitate sacrificial analysis (i.e., euthanizing a different animal for measuring each time point and retrieving the implant for histological analysis), due to the inability to monitor how the host tissues respond to the presence of the material in situ. This is expensive, inaccurate, discontinuous, and unethical. In contrast, our manuscript presents a novel microfluidic platform potentially capable of performing non-disruptive fluid manipulations within the spatial constraints of an 8 mm diameter critical calvarial defect—a “gold standard” model for testing engineered bone tissue scaffolds in living animals. In particular, here, addressable microfluidic plumbing is specifically adapted for the in vivo implantation into a simulated rat's skull, and is integrated with a combinatorial multiplexer for a better scaling of many time points and/or biological signal measurements. The collected samples (modeled as food dyes for proof of concept) are then transported, stored, and analyzed ex vivo, which adds previously-unavailable ease and flexibility. Furthermore, care is taken to maintain a fluid equilibrium in the simulated animal's head during the sampling to avoid damage to the host and to the implant. Ultimately, future implantation protocols and technology improvements are envisioned toward the end of the manuscript. Although the bone tissue engineering application was chosen as a proof of concept, with further work, the technology is potentially versatile enough for other in vivo sampling applications. Hence, the successful outcomes of its advancement should benefit companies developing, testing, and producing vaccines and drugs by accelerating the translation of advanced cell culturing tech to the clinical market. Moreover, the nondestructive monitoring of the in vivo environment can lower animal experiment costs and provide data-gathering continuity superior to the conventional destructive analysis. Lastly, the reduction of sacrifices stemming from the use of this technology would make future animal experiments more ethical.
- 1 March 2023
- Published by AIP Publishing in Biomicrofluidics
- Vol. 17 (2) , 024103
Addressable microfluidics technology for non-sacrificial analysis of biomaterial implants in vivo
Tissue regeneration-promoting and drug-eluting biomaterials are commonly implanted into animals as a part of late-stage testing before committing to human trials required by the government. Because the trials are very expensive (e.g., they can cost over a billion U.S. dollars), it is critical for companies to have the best possible characterization of the materials' safety and efficacy before it goes into a human. However, the conventional approaches to biomaterial evaluation necessitate sacrificial analysis (i.e., euthanizing a different animal for measuring each time point and retrieving the implant for histological analysis), due to the inability to monitor how the host tissues respond to the presence of the material in situ. This is expensive, inaccurate, discontinuous, and unethical. In contrast, our manuscript presents a novel microfluidic platform potentially capable of performing non-disruptive fluid manipulations within the spatial constraints of an 8 mm diameter critical calvarial defect—a “gold standard” model for testing engineered bone tissue scaffolds in living animals. In particular, here, addressable microfluidic plumbing is specifically adapted for the in vivo implantation into a simulated rat's skull, and is integrated with a combinatorial multiplexer for a better scaling of many time points and/or biological signal measurements. The collected samples (modeled as food dyes for proof of concept) are then transported, stored, and analyzed ex vivo, which adds previously-unavailable ease and flexibility. Furthermore, care is taken to maintain a fluid equilibrium in the simulated animal's head during the sampling to avoid damage to the host and to the implant. Ultimately, future implantation protocols and technology improvements are envisioned toward the end of the manuscript. Although the bone tissue engineering application was chosen as a proof of concept, with further work, the technology is potentially versatile enough for other in vivo sampling applications. Hence, the successful outcomes of its advancement should benefit companies developing, testing, and producing vaccines and drugs by accelerating the translation of advanced cell culturing tech to the clinical market. Moreover, the nondestructive monitoring of the in vivo environment can lower animal experiment costs and provide data-gathering continuity superior to the conventional destructive analysis. Lastly, the reduction of sacrifices stemming from the use of this technology would make future animal experiments more ethical.
- Open Access
- 11 January 2022
- Published by Frontiers Media SA in Frontiers in Molecular Biosciences
- Vol. 8, 783268
A Minireview of Microfluidic Scaffold Materials in Tissue Engineering
In 2020, nearly 107,000 people in the U.S needed a lifesaving organ transplant, but due to a limited number of donors, only ∼35% of them have actually received it. Thus, successful bio-manufacturing of artificial tissues and organs is central to satisfying the ever-growing demand for transplants. However, despite decades of tremendous investments in regenerative medicine research and development conventional scaffold technologies have failed to yield viable tissues and organs. Luckily, microfluidic scaffolds hold the promise of overcoming the major challenges associated with generating complex 3D cultures: 1) cell death due to poor metabolite distribution/clearing of waste in thick cultures; 2) sacrificial analysis due to inability to sample the culture non-invasively; 3) product variability due to lack of control over the cell action post-seeding, and 4) adoption barriers associated with having to learn a different culturing protocol for each new product. Namely, their active pore networks provide the ability to perform automated fluid and cell manipulations (e.g., seeding, feeding, probing, clearing waste, delivering drugs, etc.) at targeted locations in-situ. However, challenges remain in developing a biomaterial that would have the appropriate characteristics for such scaffolds. Specifically, it should ideally be: 1) biocompatible—to support cell attachment and growth, 2) biodegradable—to give way to newly formed tissue, 3) flexible—to create microfluidic valves, 4) photo-crosslinkable—to manufacture using light-based 3D printing and 5) transparent—for optical microscopy validation. To that end, this minireview summarizes the latest progress of the biomaterial design, and of the corresponding fabrication method development, for making the microfluidic scaffolds.
- 11 January 2022
- Published by Frontiers Media SA in Frontiers in Molecular Biosciences
- Vol. 8, 783268
Open AccessA Minireview of Microfluidic Scaffold Materials in Tissue Engineering
In 2020, nearly 107,000 people in the U.S needed a lifesaving organ transplant, but due to a limited number of donors, only ∼35% of them have actually received it. Thus, successful bio-manufacturing of artificial tissues and organs is central to satisfying the ever-growing demand for transplants. However, despite decades of tremendous investments in regenerative medicine research and development conventional scaffold technologies have failed to yield viable tissues and organs. Luckily, microfluidic scaffolds hold the promise of overcoming the major challenges associated with generating complex 3D cultures: 1) cell death due to poor metabolite distribution/clearing of waste in thick cultures; 2) sacrificial analysis due to inability to sample the culture non-invasively; 3) product variability due to lack of control over the cell action post-seeding, and 4) adoption barriers associated with having to learn a different culturing protocol for each new product. Namely, their active pore networks provide the ability to perform automated fluid and cell manipulations (e.g., seeding, feeding, probing, clearing waste, delivering drugs, etc.) at targeted locations in-situ. However, challenges remain in developing a biomaterial that would have the appropriate characteristics for such scaffolds. Specifically, it should ideally be: 1) biocompatible—to support cell attachment and growth, 2) biodegradable—to give way to newly formed tissue, 3) flexible—to create microfluidic valves, 4) photo-crosslinkable—to manufacture using light-based 3D printing and 5) transparent—for optical microscopy validation. To that end, this minireview summarizes the latest progress of the biomaterial design, and of the corresponding fabrication method development, for making the microfluidic scaffolds.
- Open Access
- 1 August 2021
- Published by Elsevier in SLAS Technology
- Vol. 26 (4) , 333-366
Review of Low-Cost 3D Bioprinters: State of the Market and Observed Future Trends
- 1 August 2021
- Published by Elsevier in SLAS Technology
- Vol. 26 (4) , 333-366
Open AccessReview of Low-Cost 3D Bioprinters: State of the Market and Observed Future Trends
- Open Access
- 25 September 2020
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 8
An Introductory Overview of Image-Based Computational Modeling in Personalized Cardiovascular Medicine
Cardiovascular diseases account for the number one cause of deaths in the world. Part of the reason for such grim statistics is our limited understanding of the underlying mechanisms causing these devastating pathologies, which is made difficult by the invasiveness of the procedures associated with their diagnosis (e.g., inserting catheters into the coronal artery to measure blood flow to the heart). Likewise, it is also difficult to design and test assistive devices without implanting them in vivo. However, with the recent advancements made in biomedical scanning technologies and computer simulations, image-based modeling (IBM) has arisen as the next logical step in the evolution of non-invasive patient-specific cardiovascular medicine. Yet, due to its novelty, it is still relatively unknown outside of the niche field. Therefore, the goal of this manuscript is to review the current state-of-the-art and the limitations of the methods used in this area of research, as well as their applications to personalized cardiovascular investigations and treatments. Specifically, the modeling of three different physics – electrophysiology, biomechanics and hemodynamics – used in the cardiovascular IBM is discussed in the context of the physiology that each one of them describes and the mechanisms of the underlying cardiac diseases that they can provide insight into. Only the “bare-bones” of the modeling approaches are discussed in order to make this introductory material more accessible to an outside observer. Additionally, the imaging methods, the aspects of the unique cardiac anatomy derived from them, and their relation to the modeling algorithms are reviewed. Finally, conclusions are drawn about the future evolution of these methods and their potential toward revolutionizing the non-invasive diagnosis, virtual design of treatments/assistive devices, and increasing our understanding of these lethal cardiovascular diseases.
- 25 September 2020
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 8
Open AccessAn Introductory Overview of Image-Based Computational Modeling in Personalized Cardiovascular Medicine
Cardiovascular diseases account for the number one cause of deaths in the world. Part of the reason for such grim statistics is our limited understanding of the underlying mechanisms causing these devastating pathologies, which is made difficult by the invasiveness of the procedures associated with their diagnosis (e.g., inserting catheters into the coronal artery to measure blood flow to the heart). Likewise, it is also difficult to design and test assistive devices without implanting them in vivo. However, with the recent advancements made in biomedical scanning technologies and computer simulations, image-based modeling (IBM) has arisen as the next logical step in the evolution of non-invasive patient-specific cardiovascular medicine. Yet, due to its novelty, it is still relatively unknown outside of the niche field. Therefore, the goal of this manuscript is to review the current state-of-the-art and the limitations of the methods used in this area of research, as well as their applications to personalized cardiovascular investigations and treatments. Specifically, the modeling of three different physics – electrophysiology, biomechanics and hemodynamics – used in the cardiovascular IBM is discussed in the context of the physiology that each one of them describes and the mechanisms of the underlying cardiac diseases that they can provide insight into. Only the “bare-bones” of the modeling approaches are discussed in order to make this introductory material more accessible to an outside observer. Additionally, the imaging methods, the aspects of the unique cardiac anatomy derived from them, and their relation to the modeling algorithms are reviewed. Finally, conclusions are drawn about the future evolution of these methods and their potential toward revolutionizing the non-invasive diagnosis, virtual design of treatments/assistive devices, and increasing our understanding of these lethal cardiovascular diseases.