Tohid Soleymani Aghdam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tohid Soleymani Aghdam has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Hossein Kazemi Karegar
Faculty of Electrical Engineering, Shahid Beheshti University, Tehran, Iran
8 shared publications - Ali Abbasi
Department of Electrical Engineering, Tan.C., Islamic Azad University, Boushehr 7551733665, Iran
3 shared publications - Hatem Hussein Zeineldin
Khalifa University, Abu Dhabi, UAE
3 shared publications A. Karimi
1 shared publicationA. Pirayesh
1 shared publicationAhmad Salemnia
Department of Electrical Engineering, Shahid Beheshti University, Velenjak, Tehran, Iran
1 shared publication
Latest Publications
- 21 August 2023
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 52 (8) , 1328-1340
Optimal Adaptive Protection Coordination with Inter-Trips and Setting Groups for Meshed Distribution Grids
- 21 August 2023
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 52 (8) , 1328-1340
Optimal Adaptive Protection Coordination with Inter-Trips and Setting Groups for Meshed Distribution Grids
- Open Access
- 1 February 2020
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 10 (1) , 72-79
Inter-trip links incorporated optimal protection coordination
Due to advances in smart grid, different communication links as delay, inter-trip and activation are used between relays to enhance the protection system performance. In this paper, the effect of inter-trip links on optimal coordination of directional overcurrent relays (DOCRs) is analytically investigated and modelled. Moreover, an index is proposed to find the optimum locations for inter-trip link installation to reach the minimal fault clearance times under the selectivity constraint. Then a method is proposed to determine the candidate locations of inter-trip links and the associated reduced operating times. An Exhaustive search approach is also used to validate the efficiency of the proposed method. The method is simulated and tested on distribution network of IEEE 33 bus using the Power Factory software and MATLAB optimization toolbox. Genetic algorithm is used as an optimization tool to find optimal settings of relays. The results indicate the capability of proposed method in optimal protection coordination with optimum inter-trips.
- 1 February 2020
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 10 (1) , 72-79
Open AccessInter-trip links incorporated optimal protection coordination
Due to advances in smart grid, different communication links as delay, inter-trip and activation are used between relays to enhance the protection system performance. In this paper, the effect of inter-trip links on optimal coordination of directional overcurrent relays (DOCRs) is analytically investigated and modelled. Moreover, an index is proposed to find the optimum locations for inter-trip link installation to reach the minimal fault clearance times under the selectivity constraint. Then a method is proposed to determine the candidate locations of inter-trip links and the associated reduced operating times. An Exhaustive search approach is also used to validate the efficiency of the proposed method. The method is simulated and tested on distribution network of IEEE 33 bus using the Power Factory software and MATLAB optimization toolbox. Genetic algorithm is used as an optimization tool to find optimal settings of relays. The results indicate the capability of proposed method in optimal protection coordination with optimum inter-trips.
- 1 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 77-82
Optimal Adaptive Protection Using Setting Groups Allocation Based on Impedance Matrix
In this paper, an offline adaptive protection coordination based on Setting Groups (SGs) is proposed to consider the uncertainties in distribution networks. Distributed Generations (DGs) and line outages significantly change the patterns of fault current which results in miss-coordination and non-optimal tripping times. The SGs are systematically assigned based on the impedance matrix to cluster the different operating conditions of grid to a limited number of SGs, using kmeans method. Based on the assigned operating modes to each SG, an optimal coordination is solved to maximize protection system sensitivity, simultaneously preserving the selectivity in case of events like DGs disconnection and line outage. The proposed method is simulated on IEEE 30 Bus and optimum SGs are found using Genetic Algorithm (GA). The results indicate that relays present a robust protection while the selectivity is guaranteed.
- 1 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 77-82
Optimal Adaptive Protection Using Setting Groups Allocation Based on Impedance Matrix
In this paper, an offline adaptive protection coordination based on Setting Groups (SGs) is proposed to consider the uncertainties in distribution networks. Distributed Generations (DGs) and line outages significantly change the patterns of fault current which results in miss-coordination and non-optimal tripping times. The SGs are systematically assigned based on the impedance matrix to cluster the different operating conditions of grid to a limited number of SGs, using kmeans method. Based on the assigned operating modes to each SG, an optimal coordination is solved to maximize protection system sensitivity, simultaneously preserving the selectivity in case of events like DGs disconnection and line outage. The proposed method is simulated on IEEE 30 Bus and optimum SGs are found using Genetic Algorithm (GA). The results indicate that relays present a robust protection while the selectivity is guaranteed.
- 1 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 118-123
A New Strategy for Induction Motor Fault Detection Based on Wavelet Transform and Probabilistic Neural Network
Broken rotor bar faults cause of motor malfunction and reduction of the life cycle. For the safe and appropriate performance of induction motors, the motor fault detection is a critical issue. This paper presents a new strategy for the broken rotor bar fault detection of the induction motors. Finite element method (FEM) is used for accurate fault modelling and the flux density under broken rotor bar faults has been comprehensively analyzed. Moreover, a new rotor bar fault detection method based on probabilistic neural network (PNN) and wavelet transform is presented. The proposed approach uses the stator current signal amplitude samples in the time-frequency domain to extract the appropriate coefficients where they are considered as inputs to a PNN. The output of the PNN classifies the status of the rotor to a healthy or faulty condition. The performance of the proposed method is verified using numerical simulation.
- 1 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 118-123
A New Strategy for Induction Motor Fault Detection Based on Wavelet Transform and Probabilistic Neural Network
Broken rotor bar faults cause of motor malfunction and reduction of the life cycle. For the safe and appropriate performance of induction motors, the motor fault detection is a critical issue. This paper presents a new strategy for the broken rotor bar fault detection of the induction motors. Finite element method (FEM) is used for accurate fault modelling and the flux density under broken rotor bar faults has been comprehensively analyzed. Moreover, a new rotor bar fault detection method based on probabilistic neural network (PNN) and wavelet transform is presented. The proposed approach uses the stator current signal amplitude samples in the time-frequency domain to extract the appropriate coefficients where they are considered as inputs to a PNN. The output of the PNN classifies the status of the rotor to a healthy or faulty condition. The performance of the proposed method is verified using numerical simulation.
- 20 February 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 15 (1) , 183-192
Optimal Coordination of Double-Inverse Overcurrent Relays for Stable Operation of DGs
Due to the increasing penetration of Distributed Generations (DGs) in distribution networks, the performance of protective relays is becoming more critical to maintain the stability of the DGs especially during fault conditions. Among different types of DGs, Squirrel Cage Induction Generators (SCIGs) and Synchronous DGs are sensitive to faults and might become unstable even after fault clearance. Since the fault clearing time depends on the Overcurrent Relays (OCRs) characteristic curves, this paper proposes a Double-Inverse OCR (DIOCR) characteristic to provide proper coordination while maintaining DGs stability. The proposed method defines the Critical Clearing Time (CCTs) curve for each DG and combines them with DIOCRs curves and Coordination Time Interval (CTI) constraints for finding optimal DIOCRs settings. The proposed method is simulated on the IEEE 33-bus distribution network equipped with SCIG and synchronous based DGs. The obtained results highlight the capability of DIOCRs in protecting distribution system with DGs stability constraints.
- 20 February 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 15 (1) , 183-192
Optimal Coordination of Double-Inverse Overcurrent Relays for Stable Operation of DGs
Due to the increasing penetration of Distributed Generations (DGs) in distribution networks, the performance of protective relays is becoming more critical to maintain the stability of the DGs especially during fault conditions. Among different types of DGs, Squirrel Cage Induction Generators (SCIGs) and Synchronous DGs are sensitive to faults and might become unstable even after fault clearance. Since the fault clearing time depends on the Overcurrent Relays (OCRs) characteristic curves, this paper proposes a Double-Inverse OCR (DIOCR) characteristic to provide proper coordination while maintaining DGs stability. The proposed method defines the Critical Clearing Time (CCTs) curve for each DG and combines them with DIOCRs curves and Coordination Time Interval (CTI) constraints for finding optimal DIOCRs settings. The proposed method is simulated on the IEEE 33-bus distribution network equipped with SCIG and synchronous based DGs. The obtained results highlight the capability of DIOCRs in protecting distribution system with DGs stability constraints.
- 24 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 10 (3) , 2407-2415
Variable Tripping Time Differential Protection for Microgrids Considering DG Stability
Coordination between protective device fault clearing times and Distributed Generation (DGs) stability is essential to avoid nuisance tripping of DG. In this paper, a multi-agent protection scheme based on a Variable Tripping Time Differential Protection Scheme (VTDPS) is proposed for micro-grid protection capable of operating in both grid-connected and islanded mode. Variable tripping time is used for coordination with laterals protective devices without the need for additional current measurement and data transmission. Each agent is composed of primary, backup and bus protection layers, with their relevant VTDPS, that achieves main and backup protection for a microgrid. Moreover, the Critical Clearing Time (CCT) curves of DGs and tripping time curve of VTDPS are analyzed in each feeder zone and a relevant formula is developed to check the CCT constraint for the proposed multi-agent VTDPS. The presented method is simulated on a modified CIGREE microgrid benchmark system with synchronous DGs. The obtained results prove the capability of the proposed protection scheme to prevent instability of DGs in both modes of operation.
- 24 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 10 (3) , 2407-2415
Variable Tripping Time Differential Protection for Microgrids Considering DG Stability
Coordination between protective device fault clearing times and Distributed Generation (DGs) stability is essential to avoid nuisance tripping of DG. In this paper, a multi-agent protection scheme based on a Variable Tripping Time Differential Protection Scheme (VTDPS) is proposed for micro-grid protection capable of operating in both grid-connected and islanded mode. Variable tripping time is used for coordination with laterals protective devices without the need for additional current measurement and data transmission. Each agent is composed of primary, backup and bus protection layers, with their relevant VTDPS, that achieves main and backup protection for a microgrid. Moreover, the Critical Clearing Time (CCT) curves of DGs and tripping time curve of VTDPS are analyzed in each feeder zone and a relevant formula is developed to check the CCT constraint for the proposed multi-agent VTDPS. The presented method is simulated on a modified CIGREE microgrid benchmark system with synchronous DGs. The obtained results prove the capability of the proposed protection scheme to prevent instability of DGs in both modes of operation.
- 18 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 9 (6) , 5733-5741
Transient Stability Constrained Protection Coordination for Distribution Systems With DG
Overcurrent Relays (OCRs) are the main protective devices used in distribution networks. High relay operating times coupled with the low inertia time constant of Distributed Generations (DGs) can result in DG instability during fault clearance. This paper proposes a novel stability constrained protection coordination problem formulation that incorporates transient stability constraints for determining the optimal relay settings. A hybrid communication assisted protection scheme is optimally determined to satisfy both protection coordination as well as transient stability constraints. The proposed approach is tested on the IEEE-33 bus distribution system equipped with synchronous based DG. Time domain simulations are performed to determine the critical clearing time curve for each DG to be incorporated in the protection coordination problem. The proposed approach is compared against conventional protection coordination.
- 18 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 9 (6) , 5733-5741
Transient Stability Constrained Protection Coordination for Distribution Systems With DG
Overcurrent Relays (OCRs) are the main protective devices used in distribution networks. High relay operating times coupled with the low inertia time constant of Distributed Generations (DGs) can result in DG instability during fault clearance. This paper proposes a novel stability constrained protection coordination problem formulation that incorporates transient stability constraints for determining the optimal relay settings. A hybrid communication assisted protection scheme is optimally determined to satisfy both protection coordination as well as transient stability constraints. The proposed approach is tested on the IEEE-33 bus distribution system equipped with synchronous based DG. Time domain simulations are performed to determine the critical clearing time curve for each DG to be incorporated in the protection coordination problem. The proposed approach is compared against conventional protection coordination.
- 7 July 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 9 (2) , 1365-1375
Optimal Coordination of Directional Overcurrent Relays in Microgrids by Using Cuckoo-Linear Optimization Algorithm and Fault Current Limiter
Nowadays, distributed generations (DGs) and microgrids play a significant role in development of power systems, but DGs produce several protection problems especially in optimal coordination of directional overcurrent relays (DORs). Optimal coordination of DORs is a highly constrained nonlinear programming problem, which has attracted attention of many research studies in recent years. Cuckoo optimization algorithm (COA) is introduced as an optimization tool based on behavior patterns of Cuckoos. In this paper, COA and linear programming (LP) are combined as a new hybrid COA-LP optimization algorithm in order to optimize the coordination protection of DORs in microgrids and find the optimum value of fault current limiter at the point of common coupling. The optimum settings of DORs are obtained for both modes of operation: 1) grid-connected and 2) island mode. The proposed algorithm is applied to Canadian distribution benchmark and a modified IEEE 14 bus networks and compared with particle swarm optimization (PSO) and genetic algorithm (GA). The obtained results show that the computational efficiency of the proposed COA-LP is better than PSO and GA in terms of speed and total operating time of DORs.
- 7 July 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 9 (2) , 1365-1375
Optimal Coordination of Directional Overcurrent Relays in Microgrids by Using Cuckoo-Linear Optimization Algorithm and Fault Current Limiter
Nowadays, distributed generations (DGs) and microgrids play a significant role in development of power systems, but DGs produce several protection problems especially in optimal coordination of directional overcurrent relays (DORs). Optimal coordination of DORs is a highly constrained nonlinear programming problem, which has attracted attention of many research studies in recent years. Cuckoo optimization algorithm (COA) is introduced as an optimization tool based on behavior patterns of Cuckoos. In this paper, COA and linear programming (LP) are combined as a new hybrid COA-LP optimization algorithm in order to optimize the coordination protection of DORs in microgrids and find the optimum value of fault current limiter at the point of common coupling. The optimum settings of DORs are obtained for both modes of operation: 1) grid-connected and 2) island mode. The proposed algorithm is applied to Canadian distribution benchmark and a modified IEEE 14 bus networks and compared with particle swarm optimization (PSO) and genetic algorithm (GA). The obtained results show that the computational efficiency of the proposed COA-LP is better than PSO and GA in terms of speed and total operating time of DORs.
- 1 November 2015
- Published by AIP Publishing in Journal of Renewable and Sustainable Energy
- Vol. 7 (6) , 063130
Optimal protection considering fault current characteristic of wind turbines in active distribution networks
Wind Turbines (WTs) make the traditional distribution networks act as active distribution networks and change the fault currents behavior and protection system operation. The fault current contribution of WTs depends on the type of WTs generators. This paper shows the impacts of WTs on Over Current Relays (OCRs) operation and proposes a new OCR with voltage dependent curve to tackle protection problems. The proposed relay changes its settings based on the voltage measured at the location of the relay. The capability of the relay is tested on two networks, including different types of WTs by Particle Swarm Optimization algorithm. Two distribution networks with different types of WTs are modeled and simulated in MATLAB\Simulink.
- 1 November 2015
- Published by AIP Publishing in Journal of Renewable and Sustainable Energy
- Vol. 7 (6) , 063130
Optimal protection considering fault current characteristic of wind turbines in active distribution networks
Wind Turbines (WTs) make the traditional distribution networks act as active distribution networks and change the fault currents behavior and protection system operation. The fault current contribution of WTs depends on the type of WTs generators. This paper shows the impacts of WTs on Over Current Relays (OCRs) operation and proposes a new OCR with voltage dependent curve to tackle protection problems. The proposed relay changes its settings based on the voltage measured at the location of the relay. The capability of the relay is tested on two networks, including different types of WTs by Particle Swarm Optimization algorithm. Two distribution networks with different types of WTs are modeled and simulated in MATLAB\Simulink.
- 14 June 2014
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 25 (10) , 1965-1975
Fixed speed wind turbine islanding detection method based on wavelet and voltage phasor
- 14 June 2014
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 25 (10) , 1965-1975
Fixed speed wind turbine islanding detection method based on wavelet and voltage phasor