Janet I. Andrews
Janet I. Andrews has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Daniel J. Diekema
Department of Medicine, Division of Infectious Diseases MaineHealth Maine Medical Center Portland Maine USA
6 shared publications Diedre K. Fleener
4 shared publicationsMichael A. Pfaller
3 shared publications- Christie P. Thomas
Department of Internal Medicine University of Iowa Carver College of Medicine Iowa City Iowa USA
2 shared publications Craig H. Syrop
2 shared publicationsJennifer R. Niebyl
2 shared publications
Latest Publications
- 19 June 2019
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 14 (1) , 77-82
Cellular-Enabled Glucometers and Maternal Glucose Control: A Quality Improvement Initiative
Management of diabetes in pregnancy is burdensome due to self-glucose monitoring, recording, and reporting demands. Cellular-enabled glucometers provide real-time transmission of glucose values independent of internet access and cell phone data plans. We describe a quality improvement (QI) intervention that introduced cellular-enabled glucometers for use during pregnancies complicated by diabetes. Our aim was to improve maternal glucose control in a cohort of insulin-requiring pregnant women enrolled in a telemedicine diabetes program. During initial establishment of a QI program, women were offered cellular-enabled glucometers but could elect to keep their standard meter. The primary outcome evaluated was glycosylated hemoglobin A1c (HbA1c) at delivery. Baseline characteristics including initial HbA1c were similar between women using a standard glucometer (n = 45) and those using a cellular-enabled glucometer (n = 72). Women who used a cellular-enabled glucometer had a lower HbA1c at delivery compared to those using a standard glucometer (5.8% vs 6.3%, P = .03). This improvement was particularly notable for women with poor glucose control (defined as HbA1c >6.5%) at initial obstetric visit. Women with poor glucose control who used a cellular-enabled glucose monitor had significantly lower HbA1c at delivery (6.0% vs 6.8%, P = .03) and greater change from initial visit compared to those using a standard glucometer (−2.6% vs −1.4%, P = .02). No statistically significant differences were detected in tracked neonatal outcomes. For pregnancies complicated by insulin-requiring diabetes, use of cellular-enabled glucometers as part of a perinatal diabetes program improves glucose control at delivery with timely transmission of accurate values throughout gestation.
- 19 June 2019
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 14 (1) , 77-82
Cellular-Enabled Glucometers and Maternal Glucose Control: A Quality Improvement Initiative
Management of diabetes in pregnancy is burdensome due to self-glucose monitoring, recording, and reporting demands. Cellular-enabled glucometers provide real-time transmission of glucose values independent of internet access and cell phone data plans. We describe a quality improvement (QI) intervention that introduced cellular-enabled glucometers for use during pregnancies complicated by diabetes. Our aim was to improve maternal glucose control in a cohort of insulin-requiring pregnant women enrolled in a telemedicine diabetes program. During initial establishment of a QI program, women were offered cellular-enabled glucometers but could elect to keep their standard meter. The primary outcome evaluated was glycosylated hemoglobin A1c (HbA1c) at delivery. Baseline characteristics including initial HbA1c were similar between women using a standard glucometer (n = 45) and those using a cellular-enabled glucometer (n = 72). Women who used a cellular-enabled glucometer had a lower HbA1c at delivery compared to those using a standard glucometer (5.8% vs 6.3%, P = .03). This improvement was particularly notable for women with poor glucose control (defined as HbA1c >6.5%) at initial obstetric visit. Women with poor glucose control who used a cellular-enabled glucose monitor had significantly lower HbA1c at delivery (6.0% vs 6.8%, P = .03) and greater change from initial visit compared to those using a standard glucometer (−2.6% vs −1.4%, P = .02). No statistically significant differences were detected in tracked neonatal outcomes. For pregnancies complicated by insulin-requiring diabetes, use of cellular-enabled glucometers as part of a perinatal diabetes program improves glucose control at delivery with timely transmission of accurate values throughout gestation.
- 6 April 2018
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 12 (5) , 1086-1087
Enhanced Patient Satisfaction With Cellular-Enabled Glucose Meters in Pregnancy
- 6 April 2018
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 12 (5) , 1086-1087
Enhanced Patient Satisfaction With Cellular-Enabled Glucose Meters in Pregnancy
- 1 June 2010
- Published by Elsevier in Journal of Reproductive Immunology
- Vol. 85 (2) , 198-204
Pregnant women have increased incidence of IgE autoantibodies reactive with the skin and placental antigen BP180 (type XVII collagen)
- 1 June 2010
- Published by Elsevier in Journal of Reproductive Immunology
- Vol. 85 (2) , 198-204
Pregnant women have increased incidence of IgE autoantibodies reactive with the skin and placental antigen BP180 (type XVII collagen)
- 1 October 2009
- Published by Elsevier in American Journal of Obstetrics and Gynecology
- Vol. 201 (4) , 396.e1-396.e5
Screening for Staphylococcus aureus carriage in pregnancy: usefulness of novel sampling and culture strategies
- 1 October 2009
- Published by Elsevier in American Journal of Obstetrics and Gynecology
- Vol. 201 (4) , 396.e1-396.e5
Screening for Staphylococcus aureus carriage in pregnancy: usefulness of novel sampling and culture strategies
- Open Access
- 1 July 2009
- Published by The Endocrine Society in The Journal of Clinical Endocrinology & Metabolism
- Vol. 94 (7) , 2524-2530
A Recently Evolved Novel Trophoblast-Enriched Secreted Form of fms-Like Tyrosine Kinase-1 Variant Is Up-Regulated in Hypoxia and Preeclampsia
Context: Recent published studies indicate a possible role for sFlt1 in the development of preeclampsia. Objective: The objective of the study was to investigate the expression and regulation of sFlt1-e15a, a recently described novel C-terminal variant isoform of sFlt1. Design: The studies included a computational comparative analysis of the genomic locus of sFlt1 across vertebrate species; an assessment of sFlt1 variants in human and rhesus cells and tissues; an analysis of sFlt1 variants transiently expressed in HeLa and COS-7 cells; an evaluation of the effect of hypoxia on sFlt1 expression in trophoblasts; and a comparison of placental sFlt1 expression between pregnancies complicated by preeclampsia and control pregnancies. Result and Conclusions: sFlt1-e15a emerged as an alternate transcript of Flt1 late in evolution with the insertion of an AluSq sequence into the primate genome after the emergence of the simian infraorder about 40 million years ago. sFlt1-e15a is particularly abundant in human placenta and trophoblasts and is also highly expressed in nonhuman primate placenta. The expressed protein has a C-terminal polyserine tail and, like reference sequence sFlt1 (sFlt1-i13), is glycosylated and secreted. Consistent with a role in placental pathophysiology, hypoxia stimulates sFlt1-e15a expression in isolated cytotrophoblasts and a trophoblast cell line, and differentiation into syncytiotrophoblasts further enhances the effect of hypoxia. Placental levels of sFlt1-e15a and sFlt1-i13 transcripts are significantly elevated in patients with preeclampsia compared with normal pregnancies. We speculate that sFlt1-e15a may contribute to the pathophysiology of preeclampsia.
- 1 July 2009
- Published by The Endocrine Society in The Journal of Clinical Endocrinology & Metabolism
- Vol. 94 (7) , 2524-2530
Open AccessA Recently Evolved Novel Trophoblast-Enriched Secreted Form of fms-Like Tyrosine Kinase-1 Variant Is Up-Regulated in Hypoxia and Preeclampsia
Context: Recent published studies indicate a possible role for sFlt1 in the development of preeclampsia. Objective: The objective of the study was to investigate the expression and regulation of sFlt1-e15a, a recently described novel C-terminal variant isoform of sFlt1. Design: The studies included a computational comparative analysis of the genomic locus of sFlt1 across vertebrate species; an assessment of sFlt1 variants in human and rhesus cells and tissues; an analysis of sFlt1 variants transiently expressed in HeLa and COS-7 cells; an evaluation of the effect of hypoxia on sFlt1 expression in trophoblasts; and a comparison of placental sFlt1 expression between pregnancies complicated by preeclampsia and control pregnancies. Result and Conclusions: sFlt1-e15a emerged as an alternate transcript of Flt1 late in evolution with the insertion of an AluSq sequence into the primate genome after the emergence of the simian infraorder about 40 million years ago. sFlt1-e15a is particularly abundant in human placenta and trophoblasts and is also highly expressed in nonhuman primate placenta. The expressed protein has a C-terminal polyserine tail and, like reference sequence sFlt1 (sFlt1-i13), is glycosylated and secreted. Consistent with a role in placental pathophysiology, hypoxia stimulates sFlt1-e15a expression in isolated cytotrophoblasts and a trophoblast cell line, and differentiation into syncytiotrophoblasts further enhances the effect of hypoxia. Placental levels of sFlt1-e15a and sFlt1-i13 transcripts are significantly elevated in patients with preeclampsia compared with normal pregnancies. We speculate that sFlt1-e15a may contribute to the pathophysiology of preeclampsia.
- 1 October 2008
- Published by Wolters Kluwer Health in Obstetrics & Gynecology
- Vol. 112 (4) , 933-938
Nonmenstrual Toxic Shock Syndrome Due to Methicillin-Resistant Staphylococcus aureus
- 1 October 2008
- Published by Wolters Kluwer Health in Obstetrics & Gynecology
- Vol. 112 (4) , 933-938
Nonmenstrual Toxic Shock Syndrome Due to Methicillin-Resistant Staphylococcus aureus
- 1 December 2007
- Published by Elsevier in American Journal of Obstetrics and Gynecology
- Vol. 197 (6) , 608.e1-608.e6
Cytomegalovirus and the role of interferon in the expression of tumor necrosis factor–related apoptosis-inducing ligand in the placenta
- 1 December 2007
- Published by Elsevier in American Journal of Obstetrics and Gynecology
- Vol. 197 (6) , 608.e1-608.e6
Cytomegalovirus and the role of interferon in the expression of tumor necrosis factor–related apoptosis-inducing ligand in the placenta
- 1 October 2007
- Published by Elsevier in American Journal of Obstetrics and Gynecology
- Vol. 197 (4) , 424.e1-424.e4
The yeast connection: is Candida linked to breastfeeding associated pain?
- 1 October 2007
- Published by Elsevier in American Journal of Obstetrics and Gynecology
- Vol. 197 (4) , 424.e1-424.e4
The yeast connection: is Candida linked to breastfeeding associated pain?
- 5 July 2007
- Published by Wiley in The FASEB Journal
- Vol. 21 (14) , 3885-3895
Intronic polyadenylation signal sequences and alternate splicing generate human soluble Fltl variants and regulate the abundance of soluble Flt1 in the placenta
The gene FLT1 produces at least two transcripts from a common transcription start site: full‐length Flt1 contains 30 exons encoding a membrane‐bound VEGF receptor;soluble Flt1 (sFlt1) shares the first 13 exons but utilizes poly(A) signal sequences within intron 13 to create a transcript that lacks downstream exons. To address the mechanisms that regulate human sFlt1, we mapped the 3′ end of sFlt1 mRNA and defined the full extent of its 3′ untranslated region (UTR). We identified a 3.2 Kb sFlt1 transcript that is cleaved within an alternatively spliced exon downstream of exon 14 and is predicted to encode a C‐terminal variant of sFlt1 with an unusual polyserine tail. sFlt1 mRNA cleavage sites within intron 13 were identified in human placenta and in vascular endothe‐lium by ribonuclease protection assay (RPA). A proximal and two distal mRNA cleavage sites were identified by RPA downstream of consensus polyadenylation signals that create variant transcripts with a 3′ UTR ranging from 30 bases to ~4 Kb. Northern blot analysis and 3′ rapid amplification of cDNA ends (RACE) in placenta confirmed the existence of distal intronic sFlt1 cleavage sites that give rise to a sFlt1 transcript of ~7 Kb. The identity of the distal signal sequences were then confirmed by mutagenesis of putative signal elements in a polyadenylation reporter assay. We demonstrate the heterogeneity of human sFlt1 that arises from alternate splicing and from alternative polyadenylation directed by strong intronic poly(A) signal sequences leading to C‐terminal variants and to an sFlt1 transcript with a large 3′ UTR containing several AU rich elements and poly(U) regions that may regulate mRNA stability.— Thomas, C. P., Andrews, J. I., Liu, K. Z. Intronic polyadenylation signal sequences and alternate splicing generate human soluble Flt1 variants and regulate the abundance of soluble Flt1 in the placenta. FASEB J . 21, 3885–3895 (2007)
- 5 July 2007
- Published by Wiley in The FASEB Journal
- Vol. 21 (14) , 3885-3895
Intronic polyadenylation signal sequences and alternate splicing generate human soluble Fltl variants and regulate the abundance of soluble Flt1 in the placenta
The gene FLT1 produces at least two transcripts from a common transcription start site: full‐length Flt1 contains 30 exons encoding a membrane‐bound VEGF receptor;soluble Flt1 (sFlt1) shares the first 13 exons but utilizes poly(A) signal sequences within intron 13 to create a transcript that lacks downstream exons. To address the mechanisms that regulate human sFlt1, we mapped the 3′ end of sFlt1 mRNA and defined the full extent of its 3′ untranslated region (UTR). We identified a 3.2 Kb sFlt1 transcript that is cleaved within an alternatively spliced exon downstream of exon 14 and is predicted to encode a C‐terminal variant of sFlt1 with an unusual polyserine tail. sFlt1 mRNA cleavage sites within intron 13 were identified in human placenta and in vascular endothe‐lium by ribonuclease protection assay (RPA). A proximal and two distal mRNA cleavage sites were identified by RPA downstream of consensus polyadenylation signals that create variant transcripts with a 3′ UTR ranging from 30 bases to ~4 Kb. Northern blot analysis and 3′ rapid amplification of cDNA ends (RACE) in placenta confirmed the existence of distal intronic sFlt1 cleavage sites that give rise to a sFlt1 transcript of ~7 Kb. The identity of the distal signal sequences were then confirmed by mutagenesis of putative signal elements in a polyadenylation reporter assay. We demonstrate the heterogeneity of human sFlt1 that arises from alternate splicing and from alternative polyadenylation directed by strong intronic poly(A) signal sequences leading to C‐terminal variants and to an sFlt1 transcript with a large 3′ UTR containing several AU rich elements and poly(U) regions that may regulate mRNA stability.— Thomas, C. P., Andrews, J. I., Liu, K. Z. Intronic polyadenylation signal sequences and alternate splicing generate human soluble Flt1 variants and regulate the abundance of soluble Flt1 in the placenta. FASEB J . 21, 3885–3895 (2007)