FKFabian Kording

Fabian Kording

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Fabian Kording has a total of 51 co-authors. Here are the top co-authors by number of shared publications:

  • Gerhard Adam

    Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf

    4 shared publications
  • Jin Yamamura

    Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf

    4 shared publications
  • Friedrich Ueberle

    Hamburg University of Applied Sciences, Faculty of Life Sciences

    3 shared publications
  • Bjoern Schoennagel

    University Medical Centre Hamburg-Eppendorf, Centre for Radiology and Endoscopy, Department of Diagnostic and Interventional Radiology, Germany

    2 shared publications
  • Caroline Jung

    University Medical Center Hamburg-Eppendorf, Center for Radiology and Endoscopy, Department of Diagnostic and Interventional Radiology, University Medical Center Hamburg-Eppendorf

    2 shared publications
  • G. Adam

    Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany

    2 shared publications

Latest Publications

  • Open Access

    Fetal Cardiac MRI Using Doppler US Gating: Emerging Technology and Clinical Implications

    by Thomas M. Vollbrecht, Malenka M. Bissell, Fabian Kording, Annegret Geipel, Alexander Isaak, Brigitte S. Strizek, Christopher Hart, Alex J. Barker, Julian A. Luetkens

    Fetal cardiac MRI using Doppler US gating is an emerging technique to support prenatal diagnosis of congenital heart disease and other cardiovascular abnormalities. Analogous to postnatal electrocardiographically gated cardiac MRI, this technique enables directly gated MRI of the fetal heart throughout the cardiac cycle, allowing for immediate data reconstruction and review of image quality. This review outlines the technical principles and challenges of cardiac MRI with Doppler US gating, such as loss of gating signal due to fetal movement. A practical workflow of patient preparation for the use of Doppler US-gated fetal cardiac MRI in clinical routine is provided. Currently applied MRI sequences (ie, cine or four-dimensional flow imaging), with special consideration of technical adaptations to the fetal heart, are summarized. The authors provide a literature review on the clinical benefits of Doppler US-gated fetal cardiac MRI for gaining additional diagnostic information on cardiovascular malformations and fetal hemodynamics. Finally, future perspectives of Doppler US-gated fetal cardiac MRI and further technical developments to reduce acquisition times and eliminate sources of artifacts are discussed. Keywords: MR Fetal, Ultrasound Doppler, Cardiac, Heart, Congenital, Obstetrics, Fetus Supplemental material is available for this article. © RSNA, 2024.


  • Open Access

    Dynamic fetal cardiovascular magnetic resonance imaging using Doppler ultrasound gating

    by Fabian Kording, Jin Yamamura, Manuela Tavares de Sousa, Christian Ruprecht, Erik Hedström, Anthony H. Aletras, P. Ellen Grant, Andrew J. Powell, Kai Fehrs, Gerhard Adam, et al.


  • Open Access

    Evaluation of a Portable Doppler Ultrasound Gating Device for Fetal Cardiac MR Imaging: Initial Results at 1.5T and 3T

    by Fabian Kording, Bjoern P. Schoennagel, Manuela Tavares de Sousa, Kai Fehrs, Gerhard Adam, Jin Yamamura, Christian Ruprecht

    Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies


  • Doppler ultrasound triggering for cardiac MRI at 7T

    by F. Kording, C. Ruprecht, B. Schoennagel, K. Fehrs, J. Yamamura, G. Adam, J. Goebel, K. Nassenstein, S. Maderwald, H.H. Quick, et al.

    Purpose A prerequisite for cardiac MR (CMR) imaging is adequate synchronization of image acquisition with the cardiac cycle. Electrocardiogram triggering may be hampered by electromagnetic interferences at high field strength. The purpose of this work is to evaluate the feasibility of Doppler ultrasound triggering for CMR image synchronization at 7T ultra‐high‐field MRI. Methods A custom‐built Doppler ultrasound (DUS) trigger device was developed. Magnetic resonance compatibility was evaluated using E‐ and H‐field probes and flip angle maps prior to the study. Cardiac MR was performed at 7T in 13 healthy subjects using DUS and pulse oximetry for triggering. For validation of the trigger signal, the electrocardiogram, pulse, and DUS signals were compared outside of the MR room. Breath‐hold cine fast low‐angle‐shot sequences were acquired in short‐axis and four‐chamber view. Image quality was assessed by two senior radiologists and by measurement of endocardial blurring. Results The maximal change in E‐ and H‐field distributions with and without transducer was 5%. No interferences were observed between DUS and MRI in the B1 maps and during CMR imaging. Validation of the DUS trigger signal resulted in a high correlation to the electrocardiographic signal of r = 0.99. Analysis of image and trigger quality revealed no significant differences. Conclusion Doppler ultrasound was applied as a new trigger method in CMR at 7T. The transmission line and transducer were locally approved as 7T MR conditional, and were successfully tested for image synchronization at 7T. In the future, this method needs to be evaluated in a larger patient population. Magn Reson Med 80:239–247, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


  • Open Access

    Doppler Ultrasound Triggering for Cardiovascular MRI at 3T in a Healthy Volunteer Study

    by Fabian Kording, Jin Yamamura, Gunnar Lund, Friedrich Ueberle, Caroline Jung, Gerhard Adam, Bjoern Philip Schoennagel

    Electrocardiogram (ECG) triggering for cardiac magnetic resonance (CMR) may be influenced by electromagnetic interferences with increasing magnetic field strength. The aim of this study was to evaluate the performance of Doppler ultrasound (DUS) as an alternative trigger technique for CMR in comparison to ECG and pulse oximetry (POX) at 3T and using different sequence types. Balanced turbo field echo two-dimensional (2D) short axis cine CMR and 2D phase-contrast angiography of the ascending aorta was performed in 11 healthy volunteers at 3T using ECG, DUS, and POX for cardiac triggering. DUS and POX triggering were compared to the reference standard of ECG in terms of trigger quality (trigger detection and temporal variability), image quality [endocardial blurring (EB)], and functional measurements [left ventricular (LV) volumetry and aortic blood flow velocimetry]. Trigger signal detection and temporal variability did not differ significantly between ECG/DUS (I = 0.6) and ECG/POX (P = 0.4). Averaged EB was similar for ECG, DUS, and POX (pECG/DUS = 0.4, pECG/POX = 0.9). Diastolic EB was significantly decreased for DUS in comparison to ECG (P = 0.02) and POX (P = 0.04). The LV function assessment and aortic blood flow were not significantly different. This study demonstrated the feasibility of DUS for gating human CMR at 3T. The magnetohydrodynamic effect did not significantly disturb ECG triggering in this small healthy volunteer study. DUS showed a significant improvement in diastolic EB but could not be identified as a superior trigger method. The potential benefit of DUS has to be evaluated in a larger clinical patient population.


  • Doppler Ultraschall im Vergleich zu Elektrokardiogramm und Pulsoximetrie bei 3T

    by F Kording, J Yamamura, F Überle, G Lund, G Adam, B Schönnagel

    Zielsetzung: Bei höheren Feldstärken wird das standardmäßig verwendete EKG für die Triggerung der MRT Herzbildgebung durch den Magneto-Hydrodynamischen-Effekt gestört. Das Ziel der Studie war die Evaluierung von Doppler Ultraschall als alternative Trigger Methode bei 3T. Material und Methodik: Die Herz MRT Bildgebung wurde an 9 Probanden an einem 3T MRT durchgeführt. Doppler Ultraschall (DUS) Flusssignale wurden während der MRT Messung mit einem MRT kompatiblen Kardiotokogramm aufgenommen wobei der Ultraschallkopf in apikaler Position unter der Spule platziert wurde. Das DUS Signal wurde außerhalb des MR Raums mit einem speziell entwickelten Algorithmus analysiert wobei die E-Welle als Trigger Zeitpunkt markiert wurde. Es wurden kurze Achsen CINE Aufnahmen sowie Flussmessungen in der Aorta descendens mit jeweils EKG, DUS und Puls Oximetrie (POX) als Trigger Quelle von jedem Probanden hintereinander angefertigt. Die DUS und POX Trigger Signale wurden für einen direkten Vergleich simultan mit dem EKG aufgezeichnet und verglichen. Die Bildqualität wurde mit der Endokardialen Bildschärfe zwischen linksventrikulärem Blut und Myokard bestimmt. Für jede Trigger Methode wurden linksventrikuläre Funktionsparameter und mittlere Flussgeschwindigkeiten bestimmt und miteinander verglichen. Ergebnisse: Doppler Ultraschall Signale wurden nicht durch elektromagnetische Interferenzen beeinträchtigt und die MRT Bilder zeigten keine Artefakte. Die mittlere Herzfrequenz der Probanden lag zwischen 60 – 70 BPM. DUS und POX RR-Intervalle korrelierten stark mit dem EKG (R = 0.9/R = 0.9). Die Sensitivität der Trigger Erkennung lag jeweils bei 96%, 97% und 96%. Die Endokardiale Bildschärfe lag im mittel über alle Herzphasen bei 3.2 ± 0.2, 2.9 ± 0.2 und 3.3 ± 0.2 Pixel. Linksventrikuläre Funktionsparameter sowie Flussmessungen waren nicht signifikant unterschiedlich. Schlussfolgerungen: Doppler Ultraschall kann auch bei 3T für die MRT Herzbildgebung sowie für Flussmessungen verwendet werden. Im Vergleich zum EKG wurden die DUS Signale nicht durch das MRT gestört.

  • Automatic differentiation of placental perfusion compartments by time-to-peak analysis in mice

    by F. Kording, N.D. Forkert, J. Sedlacik, G. Adam, K. Hecher, P. Arck, C.C. Remus


  • Doppler ultrasound compared with electrocardiogram and pulse oximetry cardiac triggering: A pilot study

    by Fabian Kording, Bjoern Schoennagel, Gunnar Lund, Friedrich Ueberle, Caroline Jung, Gerhard Adam, Jin Yamamura

    Purpose Accurate triggering of the cardiac cycle is mandatory for optimal image acquisition and thus diagnostic quality in cardiac magnetic resonance imaging. The purpose of this work was to evaluate Doppler ultrasound as an alternative trigger method in cardiac MRI. Methods Steady‐state free precession (SSFP) 2D cine CMR was performed in 11 healthy subjects at 1.5T. Doppler ultrasound (DUS), electrocardiogram (ECG) and pulse oximetry (POX) were used for cardiac triggering. DUS peak detection was verified in comparison to ECG. Quantitative analysis of image quality of each gating method was determined by calculating endocardial border sharpness (EBS) and left ventricular (LV) function parameters and compared with ECG. Results Mean difference between DUS and ECG in detected RR intervals was 0.04 ± 63 ms (r = 0.96). Trigger jitter was not different between ECG and DUS (P = 0.15) but significant different between ECG and POX (P = 0.01). EBS was similar between each method (3.1 ± 0.2 / 2.6 ± 0.2 / 2.9 ± 0.2 pixel). Mean differences in stroke volume were not significantly different with −1 ± 7 mL (ECG/DUS, P = 0.9) and 2 ± 10 mL (ECG/POX, P = 0.8). Conclusion Cine cardiac MRI using DUS was successfully demonstrated. DUS triggering is an alternative method for cardiac MRI and may be applied in a clinical setting. Magn Reson Med 74:1257–1265, 2015.


  • Evaluation of an Mr Compatible Doppler-Ultrasound Device as a New Trigger Method in Cardiac Mri: A Quantitative Comparison to ECG

    by Fabian Kording, Jin Yamamura, Chressen Much, Gerhard Adam, Bjoern Schoennagel, Ulrike Wedegärtner, Friedrich Ueberle

    Article Evaluation of an Mr Compatible Doppler-Ultrasound Device as a New Trigger Method in Cardiac Mri: A Quantitative Comparison to ECG was published on September 7, 2013 in the journal Biomedical Engineering / Biomedizinische Technik (volume 58, issue SI-1-Track-L).