SWSilvio Edegar Weschenfelder

Silvio Edegar Weschenfelder

*This is an algorithmically generated author record based on publicly available information.

Silvio Edegar Weschenfelder has a total of 64 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Sacrificial anode Fered–Fenton process for the degradation of a model naphthenic acid in high‐salinity water

    by Daniela Gier Della Rocca, Silvio Edegar Weschenfelder, Luciana Prazeres Mazur, Edinara Luiz, Daniele Cocco Durigon, João Paulo Winiarski, Rosely Aparecida Peralta, Regina F. P. M. Moreira

    Offshore oilfield produced water (OPW) is a highly complex and hypersaline effluent from oil and gas extraction industry. Since the water‐soluble organic (WSO) compounds in its composition are challenging to be eliminated, their treatment by various advanced oxidation processes (AOP) have been proposed. Among these, Fenton‐like processes have shown promising results in the degradation of recalcitrant organic pollutants present in OPW. Nevertheless, most of the studies have not considered the high salinity of OPW from offshore production units. Therefore, this study investigates a sacrificial anode Fered–Fenton (EF‐Fered) process to degrade a persistent naphthenic acid cyclohexane carboxylic acid (CHA), as a WSO model contaminant, in hypersaline synthetic OPW (100 g L −1 NaCl). The simultaneous effect of homogeneous Fenton oxidation and in‐situ electrogenerated active chlorine and ferryl‐oxo species was systematically evaluated under varying operational conditions (current density, H 2 O 2 concentration, pH, and temperature). Results revealed that acidic conditions (pH 3) are strictly required to maximize removal efficiency, circumventing the chloride scavenging effect through favourable iron speciation and HOCl generation. Under optimal conditions, the EF‐Fered system achieved 88% removal of CHA in 30 min, significantly outperforming conventional Fenton oxidation (51%). Despite operating under oxidant‐saturated regimes at higher current densities, the sacrificial anode configuration demonstrated remarkable robustness with H 2 O 2 supplementation. These findings propose a highly efficient and easily scalable electrochemical strategy to overcome the salinity barrier in the treatment of highly soluble organic pollutants in OPW.

  • Open Access

    Efficient Removal of Dissolved Organics and Naphthenic Acids from Offshore Produced Water: Performance and Challenges of an Electrochemical Pilot Plant

    by Daniela Gier Della Rocca, Silvio Edegar Weschenfelder, Marta Cordeiro da Fonseca, Glaucia Rodrigues Vieira de Almeida da Fonseca, Luciana Prazeres Mazur, SálVio Lima de Carvalho Neto, Adriano da Silva, DébOra de Oliveira, Regina F. P. M. Moreira

    Oilfield produced water (OPW) is a complex wastewater, including recalcitrant compounds and stable emulsions. Although electrochemical treatment has shown promising laboratory-scale results for treating this effluent, pilot-scale validation and scale-up remain poorly explored. Therefore, this study investigates the treatment of real offshore OPW using two electrochemical pilot plants (6 and 15 L). Under the optimum operating conditions (25 A·m–2 and a residence time of 4 min), the process reduced total oil and grease from 152 to 3 mg·L–1, turbidity from 69.4 to 1.0 NTU, and total organic carbon from 561 to 42 mg·L–1. In addition, the larger pilot unit achieved similar or improved performance, confirming the feasibility of process scale-up. The results indicate that electrocoagulation/flocculation and electro-oxidation occurred simultaneously, promoting the rapid removal of dissolved organic compounds and anodic transformation of the naphthenic acids. Practical aspects relevant to offshore implementation, including energy demand (7.8 kWh kg of TOG removed–1), heat generation (166 W), gas evolution (13.5 L·h–1), and process footprint (10 m·h–1 and 15 h–1), are also discussed, highlighting the feasibility of industrial implementation.


  • Open Access

    Flocculation–microfiltration integration for high-salinity oilfield offshore produced water treatment

    by Mariane Carolina Proner, Maria Alice Prado Cechinel, Carine Loureço Alves, Sálvio Lima de Carvalho Neto, Silvio Edegar Weschenfelder, Sergio Yesid Gómez González, Alan Ambrosi, Marco Di Luccio, Regina de Fatima Peralta Muniz Moreira

  • Open Access

    The role of molecular structure of organic acids and pH in synthetic produced water ozonation

    by Clintia Cardoso Portilho, Júlia Pereira Gonçalves, Heloísa Bremm Madalosso, Sálvio Lima de Carvalho Neto, Bruna Porto, Luciano DA Silva, Silvio Weschenfelder, Adriano da Silva

    Oilfield produced water generated during oil and gas production contains high salinity and significant concentrations of recalcitrant organic compounds, particularly organic acids. This study investigated the ozonation of benzoic acid (BA) and valeric acid (VA) as model compounds in synthetic produced water, evaluating single- and bicomponent systems under different initial pH conditions (8, 10, and 12). Additional bicomponent mixtures with mass ratios of 1:2 and 2:1 were assessed at pH 12 to examine of component interactions on degradation kinetics. Ozonation experiments were performed in a batch reactor, with degradation kinetics monitored via UHPLC–MS. Ozone concentrations in gas and aqueous phases, as well as pH variation, were continuously evaluated. Results showed that degradation efficiency strongly depends on pH and molecular structure. In single-component systems, VA degradation was highly pH-dependent, reaching ~87% at pH 12 due to intensified indirect oxidation, while BA exhibited consistently high removal efficiencies (>88%) across all pH values, reflecting its high intrinsic reactivity toward molecular ozone. In bicomponent systems, competitive effects reduced performance at pH 8 and 10; however, at pH 12 degradation efficiencies exceeded 80% for both compounds, indicating that enhanced hydroxyl radical formation mitigates competition effects. Kinetic data were satisfactorily described by a pseudo-first-order model under most conditions. The integrated evaluation of degradation kinetics, ozone consumption, and pH variation provides mechanistic insights into ozonation processes and supports its application for the treatment of produced water containing structurally diverse organic acids.

  • Oilfield produced water treatment by membranes: insights, challenges, and technological readiness

    by Mariane Carolina Proner, Silvio Edegar Weschenfelder, Luciana Prazeres Mazur, Alan Ambrosi, Marco Di Luccio, Regina F. P. M. Moreira


  • Water and wastewater treatment by micellar enhanced ultrafiltration – A critical review

    by Mileena Moreno, Luciana P. Mazur, Silvio Edegar Weschenfelder, Renata J. Regis, Rodrigo A.F. de Souza, Belisa A. Marinho, Adriano da Silva, Selene M.A. Guelli U. de Souza, Antônio Augusto U. de Souza


  • Água produzida e seu impacto na indústria petrolífera

    by Juliana Dumard Carracena Candido, Silvio Edegar Weschenfelder, Helen Conceição Ferraz

    Anais do I Web Encontro Nacional de Engenharia Química (978-65-5941-255-6) - Água Produzida E Seu Impacto Na Indústria Petrolífera

  • Fouling mitigation in produced water treatment by conjugation of advanced oxidation process and microfiltration

    by Anna Danielli da Fonseca Ferreira, Déborah Regina Bispo Coelho, Rafael Victor Gomes dos Santos, Kleby Soares Nascimento, Fabricio de Andrade Presciliano, Felipe Pereira da Silva, Juacyara Carbonelli Campos, Fabiana Valéria da Fonseca, Cristiano Piacsek Borges, Silvio Edegar Weschenfelder

    This work explored the use of ozonation and photoperoxidation before the microfiltration process to reduce fouling. Produced water was synthesized with salt, viscosifier, and surfactant. The additives influence on membrane fouling was evaluated. Photoperoxidation process led to an overall better performance than ozonation in terms of oil removal and fouling reduction. The maximum oil removal efficiency was 86%, obtained for emulsions with salt after 2 h of treatment (COD: H2O2 ratio 1:1, UV dose of 965 J/m2). The inclusion of chemical additives impaired the oxidative power of hydroxyl radicals leading to a moderate oil removal; however, they were still able to reduce membrane fouling, mainly in oil/water emulsions with viscosifier. Higher salt concentration promoted fouling resistance and also benefited the permeate quality. Cross-flow microfiltration process integrated with photoperoxidation was able to improve the permeate flux from 84 to 182 L/m2.h after 3 h of exposure to UV radiation, resulting in a permeate with less than 10 mg/L of oil content. Graphical abstract


  • The use of oilfield gaseous byproducts as extractants of recalcitrant naphthenic acids from synthetic produced water

    by Ana Caroline Klemz, Mayra Stéphanie Pascoal Damas, Sergio Yesid Gómez González, Luciana Prazeres Mazur, Belisa Alcantara Marinho, Silvio Edegar Weschenfelder, Débora de Oliveira, Adriano da Silva, José Alexandre Borges Valle, Antônio Augusto U. de Souza, et al.