Michael E. Gehm
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Michael E. Gehm has a total of 287 co-authors. Here are the top co-authors by number of shared publications:
Hao Xin
Electrical and Computer Engineering Department, University of Arizona, Tucson, Arizona, 85721, USA
26 shared publicationsWei-Ren Ng
Electrical and Computer Engineering Department, University of Arizona, Tucson, Arizona, 85721, USA
24 shared publicationsDavid J. Brady
Department of Electrical and Computer Engineering, Duke University, Durham, North Carolina 27708;
19 shared publications- Esteban Vera
School of Electrical Engineering, Pontificia Universidad Catlica de Valparaso, Valparaso, Chile
19 shared publications Min Liang
Electrical and Computer Engineering Department, University of Arizona, Tucson, Arizona, 85721, USA
15 shared publicationsD. J. Brady
Duke University ECE Department, Box 90291, Durham, North Carolina 27708, USA
13 shared publications
Latest Publications
- 14 October 2025
- Published by Optica Publishing Group in Applied Optics
- Vol. 64 (30) , 9017-9023
Design and analysis of asymmetric vision from a plume of oriented synthetic aerosol particles
The introduction of scattering media along an imaging path typically results in a deterioration of image quality, as scattering re-directs light into off-axis trajectories. Our goal is to create an asymmetric vision environment by exacerbating this deterioration of image quality along only one view direction, while the opposing view direction retains reasonable vision quality. This environment will be imposed by a plume of engineered aerosol particles, causing asymmetric image information propagation between forward and backward view directions. This aerosol particle is necessarily asymmetric in both geometry and absorption behavior, resulting in scattering mean free path length differences between forward and backward propagation directions. Here, we present our current particle design, the microclub, and initial optical modeling results that indicate the microclub particle could affect such an asymmetric vision environment.
- 14 October 2025
- Published by Optica Publishing Group in Applied Optics
- Vol. 64 (30) , 9017-9023
Design and analysis of asymmetric vision from a plume of oriented synthetic aerosol particles
The introduction of scattering media along an imaging path typically results in a deterioration of image quality, as scattering re-directs light into off-axis trajectories. Our goal is to create an asymmetric vision environment by exacerbating this deterioration of image quality along only one view direction, while the opposing view direction retains reasonable vision quality. This environment will be imposed by a plume of engineered aerosol particles, causing asymmetric image information propagation between forward and backward view directions. This aerosol particle is necessarily asymmetric in both geometry and absorption behavior, resulting in scattering mean free path length differences between forward and backward propagation directions. Here, we present our current particle design, the microclub, and initial optical modeling results that indicate the microclub particle could affect such an asymmetric vision environment.
- 29 August 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (25) , 6776-6785
Asymmetric imaging in the presence of a bright interferent
Given two aerosol plumes—one scattering and one absorbing—in the presence of a bright interferent, it has been shown that the image contrast ratio through the pair of plumes is different in the two opposing view directions [ Appl. Opt. 54, 12 (2015)APOPAI 0003-6935 10.1364/AO.54.000012 ]. Here, we generalize those earlier findings to plumes with mixed absorbing and scattering properties. By using the path integral solution to the radiative transfer equation, we incorporate both path length dependence and redirection of light due to multiple scattering and allow for arbitrary interferent location. Within this expanded model, we demonstrate that these effects can significantly alter the asymmetry predicted by the previous work.
- 29 August 2024
- Published by Optica Publishing Group in Applied Optics
- Vol. 63 (25) , 6776-6785
Asymmetric imaging in the presence of a bright interferent
Given two aerosol plumes—one scattering and one absorbing—in the presence of a bright interferent, it has been shown that the image contrast ratio through the pair of plumes is different in the two opposing view directions [ Appl. Opt. 54, 12 (2015)APOPAI 0003-6935 10.1364/AO.54.000012 ]. Here, we generalize those earlier findings to plumes with mixed absorbing and scattering properties. By using the path integral solution to the radiative transfer equation, we incorporate both path length dependence and redirection of light due to multiple scattering and allow for arbitrary interferent location. Within this expanded model, we demonstrate that these effects can significantly alter the asymmetry predicted by the previous work.
- 16 April 2024
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 35 (5) , 855-861
Spectral Reconstruction Improvement in a Cycloidal Coded-Aperture Mass Spectrometer
Spatial aperture coding is a technique used to improve throughput without sacrificing resolution both in optical spectroscopy and sector mass spectrometry (MS). Previous work demonstrated that aperture coding combined with a position-sensitive array detector in a miniature cycloidal mass spectrometer was successful in providing high-throughput, high-resolution measurements. However, due to poor alignment and field nonuniformities, reconstruction artifacts were present. Recently, significant progress was made in eliminating most of the reconstruction artifacts with improved field uniformity and alignment. However, artifacts as large as 1/3 of the main peak were still observed at low mass ( 17 u) and a larger curvature did not pass through all slits in the coded aperture. Therefore, when reconstructing with a system response derived from the aperture image from a higher mass m/z = 32 u ion, reconstruction artifacts appeared for m/z < 17 u. In this work, two methods were implemented to significantly reduce the presence of artifacts in reconstructed data. First, we modified the reconstruction algorithm to incorporate a mass-dependent system response function across the mass range (10–110 u). This method reduced the size of the artifacts by 82%. Second, to validate the hypothesis that the mass-dependent system response function was a result of differences in curvature of ions in the ion source, we modified the design of the ion source by shifting the coded aperture slits relative to the center of the ionization volume. This method resulted in ions of all masses passing through all slits in the coded aperture, a constant system response function across the entire mass range. Artifacts were reduced by 94%.
- 16 April 2024
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 35 (5) , 855-861
Spectral Reconstruction Improvement in a Cycloidal Coded-Aperture Mass Spectrometer
Spatial aperture coding is a technique used to improve throughput without sacrificing resolution both in optical spectroscopy and sector mass spectrometry (MS). Previous work demonstrated that aperture coding combined with a position-sensitive array detector in a miniature cycloidal mass spectrometer was successful in providing high-throughput, high-resolution measurements. However, due to poor alignment and field nonuniformities, reconstruction artifacts were present. Recently, significant progress was made in eliminating most of the reconstruction artifacts with improved field uniformity and alignment. However, artifacts as large as 1/3 of the main peak were still observed at low mass ( 17 u) and a larger curvature did not pass through all slits in the coded aperture. Therefore, when reconstructing with a system response derived from the aperture image from a higher mass m/z = 32 u ion, reconstruction artifacts appeared for m/z < 17 u. In this work, two methods were implemented to significantly reduce the presence of artifacts in reconstructed data. First, we modified the reconstruction algorithm to incorporate a mass-dependent system response function across the mass range (10–110 u). This method reduced the size of the artifacts by 82%. Second, to validate the hypothesis that the mass-dependent system response function was a result of differences in curvature of ions in the ion source, we modified the design of the ion source by shifting the coded aperture slits relative to the center of the ionization volume. This method resulted in ions of all masses passing through all slits in the coded aperture, a constant system response function across the entire mass range. Artifacts were reduced by 94%.
- 17 March 2024
- Published by Wiley in Advanced Functional Materials
- Vol. 34 (29)
Toward One‐Way Smoke: Synthesis of Copper‐Based Microclubs with Asymmetric Scattering and Absorption
The ultimate goal of this work is to create an engineered aerosol that acts as one‐way smoke, i.e. it creates an asymmetric vision environment in which the ability to image objects depends on the viewing direction. To this end, a rapid, one‐pot synthesis of copper‐based microclubs is developed that consists of a Cu2O octahedron attached to a Cu2O@Cu shaft. Millions of synthesized particles are analyzed in minutes with a FlowCam to provide a robust statistical analysis of their geometry, and rapidly elucidate the roles of the reaction constituents on the particle shape and yield. The combination of asymmetry in both shape and composition introduces a 30% difference in scattering of light propagating parallel to the microclub axis from opposing directions. This work represents a first step toward the creation of an asymmetric imaging environment with an aerosol consisting of acoustically aligned microclubs.
- 17 March 2024
- Published by Wiley in Advanced Functional Materials
- Vol. 34 (29)
Toward One‐Way Smoke: Synthesis of Copper‐Based Microclubs with Asymmetric Scattering and Absorption
The ultimate goal of this work is to create an engineered aerosol that acts as one‐way smoke, i.e. it creates an asymmetric vision environment in which the ability to image objects depends on the viewing direction. To this end, a rapid, one‐pot synthesis of copper‐based microclubs is developed that consists of a Cu2O octahedron attached to a Cu2O@Cu shaft. Millions of synthesized particles are analyzed in minutes with a FlowCam to provide a robust statistical analysis of their geometry, and rapidly elucidate the roles of the reaction constituents on the particle shape and yield. The combination of asymmetry in both shape and composition introduces a 30% difference in scattering of light propagating parallel to the microclub axis from opposing directions. This work represents a first step toward the creation of an asymmetric imaging environment with an aerosol consisting of acoustically aligned microclubs.
- 9 August 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (33) , 11357-11363
The Long Neglected Cycloidal Mass Analyzer
In 1938, Walker Bleakney and John A. Hipple first described the cycloidal mass analyzer as the only mass analyzer configuration capable of “perfect” ion focusing. Why has their geometry been largely neglected for many years and how might it earn a respectable place in the world of modern chemical analysis? This Perspective explores the properties of the cycloidal mass analyzer and identifies the lack of suitable ion array detectors as a significant reason why cycloidal mass analyzers are not widely used. The recent development of capacitive transimpedance amplifier array detectors can enable several techniques using cycloidal mass analyzers including spatially coded apertures and single particle mass analysis with a “virtual-slit”, helping the cycloidal mass analyzer earn a respectable place in chemical analysis.
- 9 August 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (33) , 11357-11363
The Long Neglected Cycloidal Mass Analyzer
In 1938, Walker Bleakney and John A. Hipple first described the cycloidal mass analyzer as the only mass analyzer configuration capable of “perfect” ion focusing. Why has their geometry been largely neglected for many years and how might it earn a respectable place in the world of modern chemical analysis? This Perspective explores the properties of the cycloidal mass analyzer and identifies the lack of suitable ion array detectors as a significant reason why cycloidal mass analyzers are not widely used. The recent development of capacitive transimpedance amplifier array detectors can enable several techniques using cycloidal mass analyzers including spatially coded apertures and single particle mass analysis with a “virtual-slit”, helping the cycloidal mass analyzer earn a respectable place in chemical analysis.
- 31 December 2020
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 32 (2) , 509-518
Improving the Performance of a Cycloidal Coded-Aperture Miniature Mass Spectrometer
Cycloidal sector mass analyzers have, in principle, perfect focusing due to perpendicularly oriented uniform electric and magnetic fields, making them ideal candidates for incorporation of spatially coded apertures. We have previously demonstrated a proof-of-concept cycloidal-coded aperture miniature mass spectrometer (C-CAMMS) instrument and achieved a greater than 10-fold increase in throughput without sacrificing resolution, compared with a single slit instrument. However, artifacts were observed in the reconstructed mass spectrum due to nonuniformity in the electric field and misalignment of the detector and the ion source with the mass analyzer focal plane. In this work, we modified the mass analyzer design of the previous C-CAMMS instrument to improve electric field uniformity, improve the alignment of the ion source and the mass analyzer with the detector, and increase the depth-of-focus to further facilitate alignment. A comparison of reconstructed spectra of a mixture of dry air and toluene at different electric fields was performed using the improved C-CAMMS prototype. A reduction in reconstruction artifacts compared to our proof-of-concept C-CAMMS instrument highlights the improved performance enabled by the design changes.
- 31 December 2020
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 32 (2) , 509-518
Improving the Performance of a Cycloidal Coded-Aperture Miniature Mass Spectrometer
Cycloidal sector mass analyzers have, in principle, perfect focusing due to perpendicularly oriented uniform electric and magnetic fields, making them ideal candidates for incorporation of spatially coded apertures. We have previously demonstrated a proof-of-concept cycloidal-coded aperture miniature mass spectrometer (C-CAMMS) instrument and achieved a greater than 10-fold increase in throughput without sacrificing resolution, compared with a single slit instrument. However, artifacts were observed in the reconstructed mass spectrum due to nonuniformity in the electric field and misalignment of the detector and the ion source with the mass analyzer focal plane. In this work, we modified the mass analyzer design of the previous C-CAMMS instrument to improve electric field uniformity, improve the alignment of the ion source and the mass analyzer with the detector, and increase the depth-of-focus to further facilitate alignment. A comparison of reconstructed spectra of a mixture of dry air and toluene at different electric fields was performed using the improved C-CAMMS prototype. A reduction in reconstruction artifacts compared to our proof-of-concept C-CAMMS instrument highlights the improved performance enabled by the design changes.
- 3 December 2019
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 59 (10) , 102402-13
Resolution and sampling analysis in digital in-line holography with spherical wave illumination
The resolution optimization and sampling strategies in practical digital in-line holography (DIH) with spherical wave illumination are analytically studied by optimizing system parameters. Optimal parameters of holographic recording, including illumination wavelength, numerical aperture of the spherical illumination wave, source-sensor distance, object–sensor distance, and sampling parameters of the sensor, for achievable resolution are worked out. A formula is derived to guide the DIH system design in general cases. Different sampling strategies associated with corresponding reconstruction waves (plane wave and spherical waves with various curvatures) are analyzed. The reason why recording with spherical wave and reconstructing with plane wave works well in practice is explained in detail. We also present how to determine the reconstruction distance and magnification to reconcile the curvature difference. The analysis is carried out mathematically and verified by simulated holograms. Optical experiments with U.S. Air Force resolution target are carried out based on the analysis for further verification.
- 3 December 2019
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 59 (10) , 102402-13
Resolution and sampling analysis in digital in-line holography with spherical wave illumination
The resolution optimization and sampling strategies in practical digital in-line holography (DIH) with spherical wave illumination are analytically studied by optimizing system parameters. Optimal parameters of holographic recording, including illumination wavelength, numerical aperture of the spherical illumination wave, source-sensor distance, object–sensor distance, and sampling parameters of the sensor, for achievable resolution are worked out. A formula is derived to guide the DIH system design in general cases. Different sampling strategies associated with corresponding reconstruction waves (plane wave and spherical waves with various curvatures) are analyzed. The reason why recording with spherical wave and reconstructing with plane wave works well in practice is explained in detail. We also present how to determine the reconstruction distance and magnification to reconcile the curvature difference. The analysis is carried out mathematically and verified by simulated holograms. Optical experiments with U.S. Air Force resolution target are carried out based on the analysis for further verification.
- Open Access
- 9 July 2019
- Published by Optica Publishing Group in Optica
- Vol. 6 (7) , 864-871
Single-shot multispectral imaging through a thin scatterer
Performing imaging with scattered light is challenging due to the complex and random modulation imposed upon the light by the scatterer. Persistent correlations, such as the optical memory effect (ME), enable high-fidelity, diffraction-limited imaging through scattering media without any prior knowledge of or access to the scattering media. However, conventional ME techniques have been limited to gray-scale imaging. We overcome this restriction by using spectral coding and compressed sensing to realize snapshot color imaging through scattering media. We demonstrate our method and obtain high-fidelity multispectral images using both emulated data (spanning the visible and infrared) and experimental data (in the visible).
- 9 July 2019
- Published by Optica Publishing Group in Optica
- Vol. 6 (7) , 864-871
Open AccessSingle-shot multispectral imaging through a thin scatterer
Performing imaging with scattered light is challenging due to the complex and random modulation imposed upon the light by the scatterer. Persistent correlations, such as the optical memory effect (ME), enable high-fidelity, diffraction-limited imaging through scattering media without any prior knowledge of or access to the scattering media. However, conventional ME techniques have been limited to gray-scale imaging. We overcome this restriction by using spectral coding and compressed sensing to realize snapshot color imaging through scattering media. We demonstrate our method and obtain high-fidelity multispectral images using both emulated data (spanning the visible and infrared) and experimental data (in the visible).
- Open Access
- 22 March 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 6 (02) , 021604-8
Three-dimensionally-printed anthropomorphic physical phantom for mammography and digital breast tomosynthesis with custom materials, lesions, and uniform quality control region
Physical phantoms allow for direct evaluation of different imaging systems and settings. Full-field digital mammography (FFDM) phantoms currently in clinical use, such as the American College of Radiology (ACR)1 and Contrast Detail Mammography (CDMAM)2 phantoms, are composed of simple test objects embedded in a single layer within a uniform background. Although widely accepted, these simple phantoms may not directly predict how the hardware-software combination of a medical imaging system will image a variety of patients in the clinic. In recent years, digital breast tomosynthesis (DBT) adoption has been accelerating, with DBT installations comprising half of all US mammography facilities and accounting for a third of all units.3 However, existing clinical breast phantoms all predate DBT and do not evaluate how image quality can be impacted by DBT artifacts and three-dimensional (3-D) anatomical details.4
- 22 March 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 6 (02) , 021604-8
Open AccessThree-dimensionally-printed anthropomorphic physical phantom for mammography and digital breast tomosynthesis with custom materials, lesions, and uniform quality control region
Physical phantoms allow for direct evaluation of different imaging systems and settings. Full-field digital mammography (FFDM) phantoms currently in clinical use, such as the American College of Radiology (ACR)1 and Contrast Detail Mammography (CDMAM)2 phantoms, are composed of simple test objects embedded in a single layer within a uniform background. Although widely accepted, these simple phantoms may not directly predict how the hardware-software combination of a medical imaging system will image a variety of patients in the clinic. In recent years, digital breast tomosynthesis (DBT) adoption has been accelerating, with DBT installations comprising half of all US mammography facilities and accounting for a third of all units.3 However, existing clinical breast phantoms all predate DBT and do not evaluate how image quality can be impacted by DBT artifacts and three-dimensional (3-D) anatomical details.4