João Manuel Domingos de Almeida Rollo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
João Manuel Domingos de Almeida Rollo has a total of 92 co-authors. Here are the top co-authors by number of shared publications:
- Carlos Alberto Fortulan
Department of Mechanical Engineering, University of São Paulo, São Carlos, Brazil
8 shared publications Pedro Luiz Di Lorenzo
Universidade de São Paulo, Brasil
3 shared publications- Benedito de Moraes Purquerio
University of São Paulo, Brazil
2 shared publications - Claudia Cristiane Camilo
Universidade de São Paulo, Brasil
2 shared publications - César Augusto Duarte Rodrigues
Universidade de São Paulo
2 shared publications - Elki Cristina de Souza
Unviersidade Federal do Tocantins
2 shared publications
Latest Publications
- 1 May 2023
- Published by Springer Nature
- p. 382-390
Characterization of the Bones of Different Bovine Breeds Based on the Microarchitecture of the Bone Tissue
- 1 May 2023
- Published by Springer Nature
- p. 382-390
Characterization of the Bones of Different Bovine Breeds Based on the Microarchitecture of the Bone Tissue
- 12 February 2020
- Published by Springer Nature
- p. 45-68
Bone Quality Assessment at the Atomic Scale
- Open Access
- 1 January 2020
- Published by FapUNIFESP (SciELO) in Materials Research
- Vol. 23 (5)
Dilatometric Cycles in the Study of Precipitation of Intermetallic Phases in Duplex Stainless Steels
Duplex stainless steels (DSS) are used in off-shore platforms due to their good properties resulting from the combination of two phases, namely austenite and ferrite. Secondary intermetallic phases, such as alpha prime (α´) and sigma (σ), which are harmful, can be formed at temperatures above 400 °C, or by a casting process. This study investigates the formation of sigma phase by thermal cycles running in a dilatometer (800 °C, 850 °C, 900 °C and 1,000 °C) for 1h, and at 850 °C for 3h and 7h. The optical microscopy of the DSS microstructure subjected to 800, 850 and 900 °C for one hour revealed a small fraction of σ phase with nucleation in the contour of ferrite/austenite phases, and tests by ferritoscope indicated a decrease (~4%) in a magnetic fraction (ferrite). However, samples subjected to dilatometric cycles at 850 °C for 3 hours showed an 18% decrease in the magnetic phase and quantitative metallography revealed a 33% fraction of σ phase precipitated in the ferrite phase. Tests conducted at 850 ºC for 7 hours indicated a high fraction of σ phase precipitated (approximately 50%), starting in the grain boundary, austenite/ferrite, and advancing in ferrite grain.
- 1 January 2020
- Published by FapUNIFESP (SciELO) in Materials Research
- Vol. 23 (5)
Open AccessDilatometric Cycles in the Study of Precipitation of Intermetallic Phases in Duplex Stainless Steels
Duplex stainless steels (DSS) are used in off-shore platforms due to their good properties resulting from the combination of two phases, namely austenite and ferrite. Secondary intermetallic phases, such as alpha prime (α´) and sigma (σ), which are harmful, can be formed at temperatures above 400 °C, or by a casting process. This study investigates the formation of sigma phase by thermal cycles running in a dilatometer (800 °C, 850 °C, 900 °C and 1,000 °C) for 1h, and at 850 °C for 3h and 7h. The optical microscopy of the DSS microstructure subjected to 800, 850 and 900 °C for one hour revealed a small fraction of σ phase with nucleation in the contour of ferrite/austenite phases, and tests by ferritoscope indicated a decrease (~4%) in a magnetic fraction (ferrite). However, samples subjected to dilatometric cycles at 850 °C for 3 hours showed an 18% decrease in the magnetic phase and quantitative metallography revealed a 33% fraction of σ phase precipitated in the ferrite phase. Tests conducted at 850 ºC for 7 hours indicated a high fraction of σ phase precipitated (approximately 50%), starting in the grain boundary, austenite/ferrite, and advancing in ferrite grain.
- 9 December 2019
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 23 (2) , 54-68
Relating mechanical properties of vertebral trabecular bones to osteoporosis
Osteoporosis is an osteometabolic disease, which promotes structural degradation of bone tissue and reduction of mineral density. We reported here a mechanical resistance assay from normal, osteopenic and osteoporotic trabecular vertebral bones of human cadavers. We performed a compressed test on ninety samples, evaluating Young’s modulus and X-ray microtomography to measure bone volume fraction and trabecular thickness. This experimental data are employed for computing the orthotropic macroscopic behavior of vertebral trabecular bones using known analytical formulae that were obtained by Galka et al. (Arch Mech 51: 335-355, 1999) via an asymptotic homogenization model. A geometrical model with a periodic orthogonal plate-like structure is applied. The properties of the bone-trabecular mass are considered linear, homogeneous and orthotropic. Average values for all technical or engineering elastic properties are computed for three important regions of the trabecular bones corresponding to thirty individuals classified as normal, osteopenic or osteoporotic by calcaneus ultrassometry. This study could be useful for a better understanding of the elastic behavior of trabecular bones in human vertebral bodies, allowing an estimation of bone answer under stress in different directions and the risk of fracture associated with osteoporosis.
- 9 December 2019
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 23 (2) , 54-68
Relating mechanical properties of vertebral trabecular bones to osteoporosis
Osteoporosis is an osteometabolic disease, which promotes structural degradation of bone tissue and reduction of mineral density. We reported here a mechanical resistance assay from normal, osteopenic and osteoporotic trabecular vertebral bones of human cadavers. We performed a compressed test on ninety samples, evaluating Young’s modulus and X-ray microtomography to measure bone volume fraction and trabecular thickness. This experimental data are employed for computing the orthotropic macroscopic behavior of vertebral trabecular bones using known analytical formulae that were obtained by Galka et al. (Arch Mech 51: 335-355, 1999) via an asymptotic homogenization model. A geometrical model with a periodic orthogonal plate-like structure is applied. The properties of the bone-trabecular mass are considered linear, homogeneous and orthotropic. Average values for all technical or engineering elastic properties are computed for three important regions of the trabecular bones corresponding to thirty individuals classified as normal, osteopenic or osteoporotic by calcaneus ultrassometry. This study could be useful for a better understanding of the elastic behavior of trabecular bones in human vertebral bodies, allowing an estimation of bone answer under stress in different directions and the risk of fracture associated with osteoporosis.
- Open Access
- 1 January 2018
- Published by Sociedade Brasileira de Quimica (SBQ) in Journal of the Brazilian Chemical Society
- Vol. 29 (9) , 1803-1810
Microstructure by Thermal Attack under Vacuum of a Superduplex Stainless Steels and Electrochemical Behavior in H2S/CO2-Saturated Synthetic Seawater
- 1 January 2018
- Published by Sociedade Brasileira de Quimica (SBQ) in Journal of the Brazilian Chemical Society
- Vol. 29 (9) , 1803-1810
Open AccessMicrostructure by Thermal Attack under Vacuum of a Superduplex Stainless Steels and Electrochemical Behavior in H2S/CO2-Saturated Synthetic Seawater
- 1 January 2018
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 912, 234-239
Study of Abrasive Cutting of Natural Quartz for Manufacturing Piezoelectric Power Generators
The present study is related with the dicing of natural quartz crystals as part of the process manufacturing of a power generator device. Power generation is important, mainly for wifi systems, which use of batteries is restrictive or impossible due short dimensions and difficult of maintenance. The manufacturing dicing process applied in micro electromechanical systems (MEMS) is the main reference for this study, which objective is explores different parameters of dicing process and the impact of it in the final performance of the generator. Failure impregnation and productivity were study in blade and band saw process with different parameters as speed and cutting force. The natural quartz was selected mainly because availability in Brazil and piezoelectric properties. It was obtained substrates AT cutting plan with thickness of 2.5mm and width of 3mm. The material was tested under compressive stress and the correspondent electric signal was obtained.
- 1 January 2018
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 912, 234-239
Study of Abrasive Cutting of Natural Quartz for Manufacturing Piezoelectric Power Generators
The present study is related with the dicing of natural quartz crystals as part of the process manufacturing of a power generator device. Power generation is important, mainly for wifi systems, which use of batteries is restrictive or impossible due short dimensions and difficult of maintenance. The manufacturing dicing process applied in micro electromechanical systems (MEMS) is the main reference for this study, which objective is explores different parameters of dicing process and the impact of it in the final performance of the generator. Failure impregnation and productivity were study in blade and band saw process with different parameters as speed and cutting force. The natural quartz was selected mainly because availability in Brazil and piezoelectric properties. It was obtained substrates AT cutting plan with thickness of 2.5mm and width of 3mm. The material was tested under compressive stress and the correspondent electric signal was obtained.
- Open Access
- 1 June 2017
- Published by FapUNIFESP (SciELO) in Research on Biomedical Engineering
- Vol. 33 (2) , 91-96
Axial compressive strength of human vertebrae trabecular bones classified as normal, osteopenic and osteoporotic by quantitative ultrasonometry of calcaneus
Keywords Osteoporosis; Calcaneal ultrasonometry; Trabecular bone; Human vertebra; Axial compression test; Correlation
- 1 June 2017
- Published by FapUNIFESP (SciELO) in Research on Biomedical Engineering
- Vol. 33 (2) , 91-96
Open AccessAxial compressive strength of human vertebrae trabecular bones classified as normal, osteopenic and osteoporotic by quantitative ultrasonometry of calcaneus
Keywords Osteoporosis; Calcaneal ultrasonometry; Trabecular bone; Human vertebra; Axial compression test; Correlation
- Open Access
- 1 January 2017
- Published by SAGE Publications in Journal of Applied Biomaterials & Functional Materials
- Vol. 15 (3) , 223-235
Bone Response to Porous Alumina Implants Coated with Bioactive Materials, Observed Using Different Characterization Techniques
Background: Implants or implantable devices should integrate into the host tissue faster than fibrous capsule formation, in which the design of the interface is one of the biggest challenges. Generally, bioactive materials are not viable for load-bearing applications, so inert biomaterials are proposed. However, the surface must be modified through techniques such as coating with bioactive materials, roughness and sized pores. The aim of this research was to validate an approach for the evaluation of the tissue growth on implants of porous alumina coated with bioactive materials. Methods: Porous alumina implants were coated with 45S5 Bioglass® (BG) and hydroxyapatite (HA) and implanted in rat tibiae for a period of 28 days. Ex vivo resections were performed to analyze osseointegration, along with histological analysis, Scanning Electron Microscopy with Energy Dispersive X-Ray spectroscopy (SEM-EDX) line scanning, radiography and biomechanical testing. Results: Given that the process of implant integration needs with the bone tissue to be accelerated, it was then seen that BG acted to start the rapid integration, and HA acted to sustaining the process. Conclusions: Inert materials coated with bioglass and HA present a potential for application as bone substitutes, preferably with pores of diameters between 100 μm and 400 μm and, restrict for smaller than 100 μm, because it prevents pores without organized tissue formation or vacant. Designed as functional gradient material, stand out for applications in bone tissue under load, where, being the porous surface responsible for the osseointegration and the inner material to bear and to transmit the loads.
- 1 January 2017
- Published by SAGE Publications in Journal of Applied Biomaterials & Functional Materials
- Vol. 15 (3) , 223-235
Open AccessBone Response to Porous Alumina Implants Coated with Bioactive Materials, Observed Using Different Characterization Techniques
Background: Implants or implantable devices should integrate into the host tissue faster than fibrous capsule formation, in which the design of the interface is one of the biggest challenges. Generally, bioactive materials are not viable for load-bearing applications, so inert biomaterials are proposed. However, the surface must be modified through techniques such as coating with bioactive materials, roughness and sized pores. The aim of this research was to validate an approach for the evaluation of the tissue growth on implants of porous alumina coated with bioactive materials. Methods: Porous alumina implants were coated with 45S5 Bioglass® (BG) and hydroxyapatite (HA) and implanted in rat tibiae for a period of 28 days. Ex vivo resections were performed to analyze osseointegration, along with histological analysis, Scanning Electron Microscopy with Energy Dispersive X-Ray spectroscopy (SEM-EDX) line scanning, radiography and biomechanical testing. Results: Given that the process of implant integration needs with the bone tissue to be accelerated, it was then seen that BG acted to start the rapid integration, and HA acted to sustaining the process. Conclusions: Inert materials coated with bioglass and HA present a potential for application as bone substitutes, preferably with pores of diameters between 100 μm and 400 μm and, restrict for smaller than 100 μm, because it prevents pores without organized tissue formation or vacant. Designed as functional gradient material, stand out for applications in bone tissue under load, where, being the porous surface responsible for the osseointegration and the inner material to bear and to transmit the loads.
- Open Access
- 16 November 2016
- Published by FapUNIFESP (SciELO) in Materials Research
- Vol. 20 (1) , 21-29
Influence of Ferrite Phase Content on the Electrochemical Properties of Duplex Stainless Steels
Duplex stainless steels have a large number of industrial applications and may replace high cost materials, especially in chloride-containing environments like seawater in off-shore platforms due to their high mechanical properties and good corrosion resistance. The influence of the ferrite content on the performance of duplex stainless steels in these corrosive environments is not well known. For the present paper, new superduplex stainless steels with ferrite between 30 and 60% were developed and their microstructure and corrosion resistance were evaluated by potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) tests in NaCl 3.5% (wt %) at 26°C and 78°C. The results obtained at 26°C showed that the pitting potential (Epitt) is little affected by the ferrite content, but for the materials with higher ferrite it was possible to observe an increase in the repassivation potential with a decrease in the corrosion potential and passive currents due to the presence of more resistive passive films. Tests performed at 78°C indicated a high decrease in the Epitt for all the samples, independently of the ferrite percentage, although maintaining superiority in higher ferrite content. Alloys with a 55% ferrite phase content, i.e. less dependent of Ni element, present a superior performance of corrosion resistance.
- 16 November 2016
- Published by FapUNIFESP (SciELO) in Materials Research
- Vol. 20 (1) , 21-29
Open AccessInfluence of Ferrite Phase Content on the Electrochemical Properties of Duplex Stainless Steels
Duplex stainless steels have a large number of industrial applications and may replace high cost materials, especially in chloride-containing environments like seawater in off-shore platforms due to their high mechanical properties and good corrosion resistance. The influence of the ferrite content on the performance of duplex stainless steels in these corrosive environments is not well known. For the present paper, new superduplex stainless steels with ferrite between 30 and 60% were developed and their microstructure and corrosion resistance were evaluated by potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) tests in NaCl 3.5% (wt %) at 26°C and 78°C. The results obtained at 26°C showed that the pitting potential (Epitt) is little affected by the ferrite content, but for the materials with higher ferrite it was possible to observe an increase in the repassivation potential with a decrease in the corrosion potential and passive currents due to the presence of more resistive passive films. Tests performed at 78°C indicated a high decrease in the Epitt for all the samples, independently of the ferrite percentage, although maintaining superiority in higher ferrite content. Alloys with a 55% ferrite phase content, i.e. less dependent of Ni element, present a superior performance of corrosion resistance.
- Open Access
- 1 January 2015
- Published by Elsevier in Procedia Engineering
- Vol. 110, 8-14
Assessment of Trabecular Bones Microarchitectures and Crystal Structure of Hydroxyapatite in Bone Osteoporosis with Application of the Rietveld Method
- 1 January 2015
- Published by Elsevier in Procedia Engineering
- Vol. 110, 8-14
Open AccessAssessment of Trabecular Bones Microarchitectures and Crystal Structure of Hydroxyapatite in Bone Osteoporosis with Application of the Rietveld Method