Dushyant Sharma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dushyant Sharma has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Sukumar Mishra
Department of Electrical Engineering Indian Institute of Technology Delhi Hauz Khas New Delhi India
5 shared publications- Anoop Jain
Department of Electrical Engineering, Indian Institute of Technology Jodhpur, Jodhpur, India
4 shared publications - Vaibhav Vaishnav
Department of Electrical Engineering, Indian Institute of Technology Jodhpur, Jodhpur, India
4 shared publications - Ayesha Firdaus
Department of Electrical Engineering Indian Institute of Technology Delhi Hauz Khas New Delhi India
2 shared publications - Behrooz Mirafzal
Department of Electrical Engineering, University of South Carolina, Columbia, SC, USA
2 shared publications - Fahmid Sadeque
Department of Electrical and Computer Engineering, Kansas State University, Manhattan, KS, USA
2 shared publications
Latest Publications
- Open Access
- 1 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
A Unified and Seamless Control Strategy for Single and Double-Stage Grid Forming PV Inverter with Partial Grid Following Operation in AC Microgrid
This study proposes a novel unified control technique considering the input side dynamics of grid forming inverters which are applicable not only for single-stage solar-fed grid forming inverters (SFGFMIs) but also double-stage SFGFMI without intervening with the DC/DC boost controller if present, ensuring stable power sharing. The autonomous system comprises multiple single-stage or double-stage SFGFMIs which are operated in both grid forming mode (GFM) mode during sufficient power and partial grid following (PGFL) mode, operating at its maximum power point (MPP), during power deficiency of any of the respective SFGFMIs. The proposed controller is initially investigated for a single-stage SFGFMI system subject to load variation and irradiation variation of one of the SFGFMI, revealing the impressive performance of the system and proper power sharing, as well as maintaining the same reactive power and proper synchronization. Further, the proposed controller performance is also evaluated for a double-stage SFGFMI system under the same disturbances as in the single-stage SFGFMI system, depicting the effectiveness and applicability of the same controller without any modification in the DC/DC boost converter's controller. The proposed controller is validated through real-time Hardware-in-the-Loop (HIL) simulations, highlighting the robustness of the controller and ensuring the stable operation of the system.
- 1 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessA Unified and Seamless Control Strategy for Single and Double-Stage Grid Forming PV Inverter with Partial Grid Following Operation in AC Microgrid
This study proposes a novel unified control technique considering the input side dynamics of grid forming inverters which are applicable not only for single-stage solar-fed grid forming inverters (SFGFMIs) but also double-stage SFGFMI without intervening with the DC/DC boost controller if present, ensuring stable power sharing. The autonomous system comprises multiple single-stage or double-stage SFGFMIs which are operated in both grid forming mode (GFM) mode during sufficient power and partial grid following (PGFL) mode, operating at its maximum power point (MPP), during power deficiency of any of the respective SFGFMIs. The proposed controller is initially investigated for a single-stage SFGFMI system subject to load variation and irradiation variation of one of the SFGFMI, revealing the impressive performance of the system and proper power sharing, as well as maintaining the same reactive power and proper synchronization. Further, the proposed controller performance is also evaluated for a double-stage SFGFMI system under the same disturbances as in the single-stage SFGFMI system, depicting the effectiveness and applicability of the same controller without any modification in the DC/DC boost converter's controller. The proposed controller is validated through real-time Hardware-in-the-Loop (HIL) simulations, highlighting the robustness of the controller and ensuring the stable operation of the system.
- 13 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 16 (2) , 1641-1653
Auxiliary Network-Enabled Attack Detection and Resilient Control of Islanded AC Microgrid
This paper proposes a cyber-resilient distributed control strategy equipped with attack detection capabilities for islanded AC microgrids in the presence of bounded stealthy Byzantine cyber attacks affecting both frequency and power information exchanged among neighboring distributed generators (DGs). The proposed control methodology relies on the construction of an auxiliary layer and the establishment of effective inter-layer cooperation between the actual DGs in the control layer and the virtual DGs in the auxiliary layer. This cooperation aims to achieve robust frequency restoration and proportional active power-sharing. It is shown that the in situ presence of a concealed auxiliary layer not only guarantees resilience against stealthy bounded attacks on both frequency and power measurements but also facilitates a network-enabled attack identification mechanism. The paper provides rigorous proof of the stability of the closed-loop system and derives bounds for frequency and power deviations under attack conditions, offering insights into the impact of the attack signal, control and pinning gains, and network connectivity on the system’s convergence properties. The performance of the proposed controllers is illustrated by simulating a networked islanded AC microgrid in a Simulink environment showcasing both attributes of attack resilience and attack detection.
- 13 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 16 (2) , 1641-1653
Auxiliary Network-Enabled Attack Detection and Resilient Control of Islanded AC Microgrid
This paper proposes a cyber-resilient distributed control strategy equipped with attack detection capabilities for islanded AC microgrids in the presence of bounded stealthy Byzantine cyber attacks affecting both frequency and power information exchanged among neighboring distributed generators (DGs). The proposed control methodology relies on the construction of an auxiliary layer and the establishment of effective inter-layer cooperation between the actual DGs in the control layer and the virtual DGs in the auxiliary layer. This cooperation aims to achieve robust frequency restoration and proportional active power-sharing. It is shown that the in situ presence of a concealed auxiliary layer not only guarantees resilience against stealthy bounded attacks on both frequency and power measurements but also facilitates a network-enabled attack identification mechanism. The paper provides rigorous proof of the stability of the closed-loop system and derives bounds for frequency and power deviations under attack conditions, offering insights into the impact of the attack signal, control and pinning gains, and network connectivity on the system’s convergence properties. The performance of the proposed controllers is illustrated by simulating a networked islanded AC microgrid in a Simulink environment showcasing both attributes of attack resilience and attack detection.
- 23 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (3) , 4313-4323
Autonomous Control of Inverters in Microgrid
Grid-interactive inverters are mainly employed to optimize power injection while synchronizing with the grid's frequency and using the phase angle as the reference point. In certain circumstances, these inverters might be required to sustain power in an isolated grid segment. To achieve this, they need to generate reference points internally and collaboratively share the power load of the islanded segment, known as a microgrid. This article presents a self-governing control architecture for inverters that autonomously detect grid reconnection and islanding events, switching between grid-following (GFL) and grid-forming (GFM) modes without relying on data communication or supervisory controllers. The proposed control architecture employs a unique control-sync technique in which two sets of parallel control paths with minimal control loops are used for GFL and GFM modes of operations. Herein, while one set of control paths is engaged to generate the pulse-width modulated (PWM) signals, the other set synchronizes in the background. This ensures seamless transitions between GFL and GFM modes of operation. The efficacy of the proposed autonomous control scheme is validated through a hardware setup comprising a 30 kVA grid emulator and three 5 - 10 kVA, 208V three-phase inverters. The experiment results confirm that inverters with the proposed controller can detect grid reconnection and islanding events and autonomously switch between GFL and GFM modes.
- 23 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (3) , 4313-4323
Autonomous Control of Inverters in Microgrid
Grid-interactive inverters are mainly employed to optimize power injection while synchronizing with the grid's frequency and using the phase angle as the reference point. In certain circumstances, these inverters might be required to sustain power in an isolated grid segment. To achieve this, they need to generate reference points internally and collaboratively share the power load of the islanded segment, known as a microgrid. This article presents a self-governing control architecture for inverters that autonomously detect grid reconnection and islanding events, switching between grid-following (GFL) and grid-forming (GFM) modes without relying on data communication or supervisory controllers. The proposed control architecture employs a unique control-sync technique in which two sets of parallel control paths with minimal control loops are used for GFL and GFM modes of operations. Herein, while one set of control paths is engaged to generate the pulse-width modulated (PWM) signals, the other set synchronizes in the background. This ensures seamless transitions between GFL and GFM modes of operation. The efficacy of the proposed autonomous control scheme is validated through a hardware setup comprising a 30 kVA grid emulator and three 5 - 10 kVA, 208V three-phase inverters. The experiment results confirm that inverters with the proposed controller can detect grid reconnection and islanding events and autonomously switch between GFL and GFM modes.
- 13 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 17 (3) , 3401-3412
Quadratic-Droop-Based Distributed Secondary Control of Microgrid With Detail-Balanced Communication Topology
This article proposes a quadratic-droop-based fixed-time distributed secondary voltage control of an islanded ac microgrid. The microgrid consists of inverter-based distributed generators, connected over a detail-balanced communication topology with bidirectional unequal edge weights. The proposed voltage restoration strategy is derived from the quadratic relation between voltage and reactive power for inductive microgrids against their linear dependence, which has been conventionally used in designing voltage droop controllers. It has been illustrated that the proposed quadratic-droop-based control design strategy shows better performance as compared with the linear counterpart. We provide a rigorous Lyapunov stability analysis for the proposed controller and also obtain an upper bound on the convergence time, independent of the system's initial conditions. In addition, frequency restoration and proportional active power sharing among the generators are realized in the fixed time. Simulations are provided to verify the efficacy of the proposed controllers, including a comparative analysis with conventional droop control and finite-time control through a case study.
- 13 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Systems Journal
- Vol. 17 (3) , 3401-3412
Quadratic-Droop-Based Distributed Secondary Control of Microgrid With Detail-Balanced Communication Topology
This article proposes a quadratic-droop-based fixed-time distributed secondary voltage control of an islanded ac microgrid. The microgrid consists of inverter-based distributed generators, connected over a detail-balanced communication topology with bidirectional unequal edge weights. The proposed voltage restoration strategy is derived from the quadratic relation between voltage and reactive power for inductive microgrids against their linear dependence, which has been conventionally used in designing voltage droop controllers. It has been illustrated that the proposed quadratic-droop-based control design strategy shows better performance as compared with the linear counterpart. We provide a rigorous Lyapunov stability analysis for the proposed controller and also obtain an upper bound on the convergence time, independent of the system's initial conditions. In addition, frequency restoration and proportional active power sharing among the generators are realized in the fixed time. Simulations are provided to verify the efficacy of the proposed controllers, including a comparative analysis with conventional droop control and finite-time control through a case study.
- 19 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Control Systems Letters
- Vol. 7, 991-996
Bounded Voltage Regulation in a Direct Current Microgrid Using Barrier Lyapunov Function With Uncertain Load Current
A distributed control methodology for steady-state voltage regulation, along with a bounded transient response in a Direct Current (DC) microgrid, is proposed in this letter. The idea of asymmetric barrier Lyapunov function (ABLF) is used in realizing the prescribed constraints on the voltage magnitudes while considering the uncertain nature of the load current. By proposing a suitable load current estimator, we show that the voltage regulation is achieved within prescribed limits, and the closed-loop system remains stable under the proposed controller. We also obtain explicit bounds on the voltage and current errors, virtual controller, and estimated load current in the post-design analysis. Simulations illustrate the theoretical findings and the robustness of the proposed scheme to load perturbations.
- 19 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Control Systems Letters
- Vol. 7, 991-996
Bounded Voltage Regulation in a Direct Current Microgrid Using Barrier Lyapunov Function With Uncertain Load Current
A distributed control methodology for steady-state voltage regulation, along with a bounded transient response in a Direct Current (DC) microgrid, is proposed in this letter. The idea of asymmetric barrier Lyapunov function (ABLF) is used in realizing the prescribed constraints on the voltage magnitudes while considering the uncertain nature of the load current. By proposing a suitable load current estimator, we show that the voltage regulation is achieved within prescribed limits, and the closed-loop system remains stable under the proposed controller. We also obtain explicit bounds on the voltage and current errors, virtual controller, and estimated load current in the post-design analysis. Simulations illustrate the theoretical findings and the robustness of the proposed scheme to load perturbations.
- 18 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Control Systems Letters
- Vol. 7, 733-738
Control of Heterogeneous Battery Energy Storage Systems-Based Microgrid Connected via Detail-Balanced Communication Topology
This paper proposes a distributed secondary control for heterogeneous battery energy storage systems (BESSs) to achieve finite-time consensus in frequency and active power while maintaining a balanced energy-level. The proposed scheme incorporates heterogeneity in electrical as well as control aspects and models heterogeneous BESS-based islanded AC microgrid as a multi-agent system with agents interacting according to a detail-balanced topology with heterogeneous edge weights. The finite-time stability of the closed-loop system, under the proposed controllers, is rigorously proved by considering a single composite homogeneous Lyapunov function, thereby calculating an upper limit on convergence time. Efficacy of the proposed controllers is illustrated by simulating a BESS-based microgrid in a Simulink environment.
- 18 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Control Systems Letters
- Vol. 7, 733-738
Control of Heterogeneous Battery Energy Storage Systems-Based Microgrid Connected via Detail-Balanced Communication Topology
This paper proposes a distributed secondary control for heterogeneous battery energy storage systems (BESSs) to achieve finite-time consensus in frequency and active power while maintaining a balanced energy-level. The proposed scheme incorporates heterogeneity in electrical as well as control aspects and models heterogeneous BESS-based islanded AC microgrid as a multi-agent system with agents interacting according to a detail-balanced topology with heterogeneous edge weights. The finite-time stability of the closed-loop system, under the proposed controllers, is rigorously proved by considering a single composite homogeneous Lyapunov function, thereby calculating an upper limit on convergence time. Efficacy of the proposed controllers is illustrated by simulating a BESS-based microgrid in a Simulink environment.
- Open Access
- 14 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 41341-41351
Synchronization of Inverters in Grid Forming Mode
This article compares two strategies for seamless (re)connection of grid-forming inverters to a microgrid powered by droop-controlled inverters. While an incoming inverter must be synced to the microgrid, seamless syncing and power-sharing are technical challenges for grid-forming inverters. In the first strategy, called the output-sync method, an incoming inverter is synced to the microgrid, and then the circuit breaker is closed for power-sharing. In the second strategy, called the controller-sync method, the inverter initially contributes at zero power following the microgrid frequency, and then the controller is transferred to the mode of power-sharing. Remarkably, the circuit breaker can be kept closed during the syncing process using the controller-sync method as the inverter starts from zero power contribution. In this novel strategy, two controller sets run in parallel, i.e., two parallel control paths are in place for obtaining the magnitude and the phase angle of the PWM reference signal. These parallel paths are synced for seamless transitions when only one of them is engaged to generate the PWM reference signal. The efficacy of these control strategies has been tested in a hardware setup of a microgrid fed by two 5kVA 208V droop-controlled inverters, and the results are presented in this article. This article is also accompanied by a video clip demonstrating the performance of the output-sync and controller-sync methods in the laboratory.
- 14 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 41341-41351
Open AccessSynchronization of Inverters in Grid Forming Mode
This article compares two strategies for seamless (re)connection of grid-forming inverters to a microgrid powered by droop-controlled inverters. While an incoming inverter must be synced to the microgrid, seamless syncing and power-sharing are technical challenges for grid-forming inverters. In the first strategy, called the output-sync method, an incoming inverter is synced to the microgrid, and then the circuit breaker is closed for power-sharing. In the second strategy, called the controller-sync method, the inverter initially contributes at zero power following the microgrid frequency, and then the controller is transferred to the mode of power-sharing. Remarkably, the circuit breaker can be kept closed during the syncing process using the controller-sync method as the inverter starts from zero power contribution. In this novel strategy, two controller sets run in parallel, i.e., two parallel control paths are in place for obtaining the magnitude and the phase angle of the PWM reference signal. These parallel paths are synced for seamless transitions when only one of them is engaged to generate the PWM reference signal. The efficacy of these control strategies has been tested in a hardware setup of a microgrid fed by two 5kVA 208V droop-controlled inverters, and the results are presented in this article. This article is also accompanied by a video clip demonstrating the performance of the output-sync and controller-sync methods in the laboratory.
- Open Access
Spatial Processing Front-End For Distant ASR Exploiting Self-Attention Channel Combinator
We present a novel multi-channel front-end based on channel shortening with theWeighted Prediction Error (WPE) method followed by a fixed MVDR beamformer used in combination with a recently proposed self-attention-based channel combination (SACC) scheme, for tackling the distant ASR problem. We show that the proposed system used as part of a ContextNet based end-to-end (E2E) ASR system outperforms leading ASR systems as demonstrated by a 21.6% reduction in relative WER on a multi-channel LibriSpeech playback dataset. We also show how dereverberation prior to beamforming is beneficial and compare the WPE method with a modified neural channel shortening approach. An analysis of the non-intrusive estimate of the signal C50 confirms that the 8 channel WPE method provides significant dereverberation of the signals (13.6 dB improvement). We also show how the weights of the SACC system allow the extraction of accurate spatial information which can be beneficial for other speech processing applications like diarization.
Open AccessSpatial Processing Front-End For Distant ASR Exploiting Self-Attention Channel Combinator
We present a novel multi-channel front-end based on channel shortening with theWeighted Prediction Error (WPE) method followed by a fixed MVDR beamformer used in combination with a recently proposed self-attention-based channel combination (SACC) scheme, for tackling the distant ASR problem. We show that the proposed system used as part of a ContextNet based end-to-end (E2E) ASR system outperforms leading ASR systems as demonstrated by a 21.6% reduction in relative WER on a multi-channel LibriSpeech playback dataset. We also show how dereverberation prior to beamforming is beneficial and compare the WPE method with a modified neural channel shortening approach. An analysis of the non-intrusive estimate of the signal C50 confirms that the 8 channel WPE method provides significant dereverberation of the signals (13.6 dB improvement). We also show how the weights of the SACC system allow the extraction of accurate spatial information which can be beneficial for other speech processing applications like diarization.
- Open Access
- 19 October 2020
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 14 (23) , 5634-5645
Dynamic power flow based simplified transfer function model to study instability of low‐frequency modes in inverter‐based microgrids
This study proposes a new modelling approach for studying low‐frequency oscillations (LFOs) in a droop controlled islanded microgrid. Due to the absence of inertia, these sources are more vulnerable to power and frequency oscillations. Their quick response can introduce faster electrical dynamics in the system which should be monitored from time to time. To ease the analysis process, this study proposes a simplified method for finding LFO in the microgrid. Inspired from the small‐signal automatic generation control model of the conventional grid, a transfer function based closed‐loop small‐signal model of inverter‐based islanded microgrid is presented in this study to study power‐sharing among the various inverters. The proposed model uses the concept of dynamic power flow through the network to find the power output of each source following load perturbations in a system. Time domain simulation results and eigenvalue analysis is provided to verify the effectiveness of the proposed small‐signal model. By comparing the results obtained with actual system simulation in MATLAB/Simulink, it is found that the proposed simplified model is able to predict the stability margin and the LFO of the system without using actual detailed state‐space modelling procedure.
- 19 October 2020
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 14 (23) , 5634-5645
Open AccessDynamic power flow based simplified transfer function model to study instability of low‐frequency modes in inverter‐based microgrids
This study proposes a new modelling approach for studying low‐frequency oscillations (LFOs) in a droop controlled islanded microgrid. Due to the absence of inertia, these sources are more vulnerable to power and frequency oscillations. Their quick response can introduce faster electrical dynamics in the system which should be monitored from time to time. To ease the analysis process, this study proposes a simplified method for finding LFO in the microgrid. Inspired from the small‐signal automatic generation control model of the conventional grid, a transfer function based closed‐loop small‐signal model of inverter‐based islanded microgrid is presented in this study to study power‐sharing among the various inverters. The proposed model uses the concept of dynamic power flow through the network to find the power output of each source following load perturbations in a system. Time domain simulation results and eigenvalue analysis is provided to verify the effectiveness of the proposed small‐signal model. By comparing the results obtained with actual system simulation in MATLAB/Simulink, it is found that the proposed simplified model is able to predict the stability margin and the LFO of the system without using actual detailed state‐space modelling procedure.