Luis Eduardo Juanicó
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Luis Eduardo Juanicó has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Marcelo Gustavo Molina
Instituto de Energía Eléctrica (IEE), Universidad Nacional de San Juan (UNSJ) and Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), San Juan J5400, Argentina
7 shared publications Alejandro D. González
4 shared publicationsEduardo Taglialavore
4 shared publicationsFabián Rinalde
National Research Council (Conicet) and Balseiro Institute, Bariloche Atomic Center
3 shared publicationsG.F. Rinalde
Centro Atómico Bariloche, 8400 Bariloche, Río Negro, Argentina
3 shared publicationsNicolás Di Lalla
3 shared publications
Latest Publications
- 30 October 2026
- Published by Emerald Publishing in Aircraft Engineering and Aerospace Technology
- p. 1-19
Balanced-lift wing-assisted hybrid airships for ultra-heavy wind turbine logistics
Purpose: The continued scaling of next-generation wind turbines toward rotor blades exceeding 120–140 m is creating major logistical constraints for conventional transport and installation systems. This study aims to investigate the feasibility of large wing-assisted balanced-lift hybrid airships as low-infrastructure platforms for the transport and airborne-crane installation of ultra-large wind turbine components. Design/methodology/approach: A multidisciplinary conceptual design and parametric optimization framework integrating buoyancy modeling, aerodynamic performance estimation, structural mass scaling, propulsion sizing and mission-level energy analysis was developed. More than 120 configurations were evaluated across a representative design space spanning envelope volume, buoyancy fraction, wing geometry and propulsion assumptions. The cruise-oriented optimization was subsequently extended to a mission-constrained buoyancy–thrust–ballast (BTB) reference configuration incorporating zero-speed payload transfer, reversible water ballast, distributed vectored propulsion, bidirectional wing lift and optional helium thermal management. Aerodynamic and structural sensitivity analyses were additionally performed to quantify the robustness of the conceptual design assumptions. Findings: The parametric analysis identifies a consistent cruise-oriented balanced-lift design region near comparable aerostatic and aerodynamic contributions, but the subsequent BTB analysis shows that this condition should not be interpreted as a fixed operational lift split. Instead, the revised vehicle follows a mission-dependent lift-sharing trajectory in which buoyancy, positive or negative aerodynamic wing lift, ballast and vectored thrust assume different roles throughout the transport–installation–return–pickup cycle. The representative WindZep-He 150 configuration retains a payload capability of approximately 150–155 t at a nominal cruise speed near 185 km/h. Segment-level mission analysis predicts approximately 9–11 t of fuel consumption for a representative 500 km round-trip transport-and-installation mission, while a 14 t onboard allocation is retained to provide operational reserve. Sensitivity analysis further indicates progressive rather than discontinuous degradation under cruise-drag penalties of 20%–30% and wing–empennage structural-mass increases of up to 75%. Research limitations/implications: This study remains a conceptual-level investigation based on semi-empirical aerodynamic methods and first-order engineering models. Configuration-specific CFD, finite-element structural and aeroelastic analysis, nonlinear flight-dynamic simulation, suspended-load dynamics, mooring-load analysis and control-system development remain necessary before detailed design. The sensitivity results nevertheless indicate that plausible first-order aerodynamic and structural uncertainties modify performance margins without overturning the underlying architectural feasibility. Originality/value: This study reframes balanced-lift not as a fixed aerostatic–aerodynamic lift ratio, but as a mission-adaptive architectural principle for ultra-heavy hybrid airships. The proposed BTB operating concept distributes the large vertical-force changes associated with payload transfer among reversible water ballast, bidirectional aerodynamic lift, thermal buoyancy preconditioning, limited compressed-air trim and distributed vectored thrust. This provides a physically consistent conceptual pathway for combining efficient forward transport with zero-speed airborne-crane capability while reducing dependence on conventional heavy-transport and erection infrastructure.
- 30 October 2026
- Published by Emerald Publishing in Aircraft Engineering and Aerospace Technology
- p. 1-19
Balanced-lift wing-assisted hybrid airships for ultra-heavy wind turbine logistics
Purpose: The continued scaling of next-generation wind turbines toward rotor blades exceeding 120–140 m is creating major logistical constraints for conventional transport and installation systems. This study aims to investigate the feasibility of large wing-assisted balanced-lift hybrid airships as low-infrastructure platforms for the transport and airborne-crane installation of ultra-large wind turbine components. Design/methodology/approach: A multidisciplinary conceptual design and parametric optimization framework integrating buoyancy modeling, aerodynamic performance estimation, structural mass scaling, propulsion sizing and mission-level energy analysis was developed. More than 120 configurations were evaluated across a representative design space spanning envelope volume, buoyancy fraction, wing geometry and propulsion assumptions. The cruise-oriented optimization was subsequently extended to a mission-constrained buoyancy–thrust–ballast (BTB) reference configuration incorporating zero-speed payload transfer, reversible water ballast, distributed vectored propulsion, bidirectional wing lift and optional helium thermal management. Aerodynamic and structural sensitivity analyses were additionally performed to quantify the robustness of the conceptual design assumptions. Findings: The parametric analysis identifies a consistent cruise-oriented balanced-lift design region near comparable aerostatic and aerodynamic contributions, but the subsequent BTB analysis shows that this condition should not be interpreted as a fixed operational lift split. Instead, the revised vehicle follows a mission-dependent lift-sharing trajectory in which buoyancy, positive or negative aerodynamic wing lift, ballast and vectored thrust assume different roles throughout the transport–installation–return–pickup cycle. The representative WindZep-He 150 configuration retains a payload capability of approximately 150–155 t at a nominal cruise speed near 185 km/h. Segment-level mission analysis predicts approximately 9–11 t of fuel consumption for a representative 500 km round-trip transport-and-installation mission, while a 14 t onboard allocation is retained to provide operational reserve. Sensitivity analysis further indicates progressive rather than discontinuous degradation under cruise-drag penalties of 20%–30% and wing–empennage structural-mass increases of up to 75%. Research limitations/implications: This study remains a conceptual-level investigation based on semi-empirical aerodynamic methods and first-order engineering models. Configuration-specific CFD, finite-element structural and aeroelastic analysis, nonlinear flight-dynamic simulation, suspended-load dynamics, mooring-load analysis and control-system development remain necessary before detailed design. The sensitivity results nevertheless indicate that plausible first-order aerodynamic and structural uncertainties modify performance margins without overturning the underlying architectural feasibility. Originality/value: This study reframes balanced-lift not as a fixed aerostatic–aerodynamic lift ratio, but as a mission-adaptive architectural principle for ultra-heavy hybrid airships. The proposed BTB operating concept distributes the large vertical-force changes associated with payload transfer among reversible water ballast, bidirectional aerodynamic lift, thermal buoyancy preconditioning, limited compressed-air trim and distributed vectored thrust. This provides a physically consistent conceptual pathway for combining efficient forward transport with zero-speed airborne-crane capability while reducing dependence on conventional heavy-transport and erection infrastructure.
- Open Access
- 7 October 2026
- Published by Springer Nature in Discover Vehicles
- Vol. 2 (1) , 47
Smart electrified trailers as distributed sensing and actuation platforms for heavy-duty freight transport
- 7 October 2026
- Published by Springer Nature in Discover Vehicles
- Vol. 2 (1) , 47
Open AccessSmart electrified trailers as distributed sensing and actuation platforms for heavy-duty freight transport
- 2 October 2026
- Published by Springer Nature in Atomic Energy
- p. 1-8
Fading fission in Western economies: structural limitations and the uncertain role of small modular reactors
- 2 October 2026
- Published by Springer Nature in Atomic Energy
- p. 1-8
Fading fission in Western economies: structural limitations and the uncertain role of small modular reactors
- 22 September 2026
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 48 (1)
A predictive thermodynamic–economic design methodology for heat-pump systems under dynamic electricity pricing
1. 1.1. The decarbonization of the building sector is widely recognized as one of the principal challenges of the global energy transition. Because space heating and domestic hot-water production a...
- 22 September 2026
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 48 (1)
A predictive thermodynamic–economic design methodology for heat-pump systems under dynamic electricity pricing
1. 1.1. The decarbonization of the building sector is widely recognized as one of the principal challenges of the global energy transition. Because space heating and domestic hot-water production a...
- Open Access
- 27 June 2026
- Published by Elsevier in SSRN Electronic Journal
Weak-Ionization Cryogenic Adsorption (WICA): A Conceptual Cyclic Process for Helium Enrichment from LNG Residual Gas
Helium is typically recovered as a secondary product during natural-gas processing using cryogenic separation, membrane systems, and adsorption-based technologies. However, the enrichment of dilute helium streams often requires multiple process stages and increasing system complexity.This technical note proposes Weak-Ionization Cryogenic Adsorption (WICA), a conceptual cyclic process for helium enrichment from LNG residual gas streams. The proposed architecture combines weak ionization, cryogenic adsorption, and periodic regeneration within a packed-bed system operating under LNG conditions.WICA seeks to exploit ionization-energy, mass-transport, adsorption, and cryogenic asymmetries naturally present in the He–N₂ system. Rather than pursuing complete plasma separation, the concept aims to generate a persistent difference in residence time between helium and nitrogen through the combined action of ionization, adsorption, and transport phenomena.The present work identifies a favorable process framework for future investigation based on the simultaneous exploitation of multiple cooperative asymmetries within a single cyclic separation process.
- 27 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessWeak-Ionization Cryogenic Adsorption (WICA): A Conceptual Cyclic Process for Helium Enrichment from LNG Residual Gas
Helium is typically recovered as a secondary product during natural-gas processing using cryogenic separation, membrane systems, and adsorption-based technologies. However, the enrichment of dilute helium streams often requires multiple process stages and increasing system complexity.This technical note proposes Weak-Ionization Cryogenic Adsorption (WICA), a conceptual cyclic process for helium enrichment from LNG residual gas streams. The proposed architecture combines weak ionization, cryogenic adsorption, and periodic regeneration within a packed-bed system operating under LNG conditions.WICA seeks to exploit ionization-energy, mass-transport, adsorption, and cryogenic asymmetries naturally present in the He–N₂ system. Rather than pursuing complete plasma separation, the concept aims to generate a persistent difference in residence time between helium and nitrogen through the combined action of ionization, adsorption, and transport phenomena.The present work identifies a favorable process framework for future investigation based on the simultaneous exploitation of multiple cooperative asymmetries within a single cyclic separation process.
- Open Access
- 29 April 2026
- Published by Corporación de Ciencia y Tecnología para el Desarrollo de la Industria Naval, Marítima y Fluvial in Ship science & technology
- Vol. 19 (38) , 89-99
Economic and Hydrodynamic Optimization of a 96,000 m³ Semi-Submersible Carrier Using Combined Drag-Reduction Technologies for Global Liquid Trade
A 96,000 m³ semi-submersible heavy liquid carrier is proposed, with the cargo hull axis located at a depth of 31–32 m and an 11 m diameter surface tower. The design integrates five commercially available drag-reduction technologies (shark-skin riblet film, micro-bubble air lubrication, controlled micro-roughness inducing benign micro-cavitation, polymer ejection, and near-complete elimination of wave-making resistance). Full-scale CFD simulations (42.8 million cells) and HSVA tank tests demonstrate 73–87 % lower frictional resistance compared with modern Aframax/Suezmax tankers at 14–20 knots. Intact transverse metacentric height reaches 60–285 m, yielding a probabilistic damage stability index A = 0.9876. Seakeeping analysis in JONSWAP spectra (Hs = 9.5 m) shows maximum pitch ±1.8° and roll ±2.3°, with bridge vertical acceleration ≤ 0.11 g and no green water up to Beaufort Force 10. Economic evaluation on disrupted Arabian Gulf–Northwest Europe routes via Cape of Good Hope and on a closed triangular crude oil/desalinated water/ethanol cycle (Arabian Gulf–China–California) demonstrates payback periods of 2.9–5.1 months and 25-year net present values of 12.4–41.7 billion USD at November 2025 market rates. The concept offers a technically mature solution for decarbonization and geopolitical risk mitigation in maritime bulk liquid transport.
- 29 April 2026
- Published by Corporación de Ciencia y Tecnología para el Desarrollo de la Industria Naval, Marítima y Fluvial in Ship science & technology
- Vol. 19 (38) , 89-99
Open AccessEconomic and Hydrodynamic Optimization of a 96,000 m³ Semi-Submersible Carrier Using Combined Drag-Reduction Technologies for Global Liquid Trade
A 96,000 m³ semi-submersible heavy liquid carrier is proposed, with the cargo hull axis located at a depth of 31–32 m and an 11 m diameter surface tower. The design integrates five commercially available drag-reduction technologies (shark-skin riblet film, micro-bubble air lubrication, controlled micro-roughness inducing benign micro-cavitation, polymer ejection, and near-complete elimination of wave-making resistance). Full-scale CFD simulations (42.8 million cells) and HSVA tank tests demonstrate 73–87 % lower frictional resistance compared with modern Aframax/Suezmax tankers at 14–20 knots. Intact transverse metacentric height reaches 60–285 m, yielding a probabilistic damage stability index A = 0.9876. Seakeeping analysis in JONSWAP spectra (Hs = 9.5 m) shows maximum pitch ±1.8° and roll ±2.3°, with bridge vertical acceleration ≤ 0.11 g and no green water up to Beaufort Force 10. Economic evaluation on disrupted Arabian Gulf–Northwest Europe routes via Cape of Good Hope and on a closed triangular crude oil/desalinated water/ethanol cycle (Arabian Gulf–China–California) demonstrates payback periods of 2.9–5.1 months and 25-year net present values of 12.4–41.7 billion USD at November 2025 market rates. The concept offers a technically mature solution for decarbonization and geopolitical risk mitigation in maritime bulk liquid transport.
- Open Access
- 28 September 2024
- Published by Ninety Nine Publication in Journal of Advance Research in Food, Agriculture and Environmental Science (ISSN 2208-2417)
- Vol. 10 (3) , 26-30
Conceptual Proposal for Enhancing Autonomous Taxi Systems: A Focus on Tesla's Cybercab
This work provides a comparative analysis of Tesla's autonomous taxi model (referred to as robotaxi or Cybercab) and proposes a new design focused on enhancing efficiency and accessibility. Previous studies have examined efficiency differences between internal combustion engine (ICE) vehicles and electric cars, as well as the specific requirements of city taxis compared to high-speed vehicles, concluding that a specialized design could yield more efficient electric taxis. Our proposed robotaxi concept aims to address several limitations in Tesla’s design, including: Increased Passenger Capacity: Expanding seating from 2 to 4 passengers. Enhanced Accessibility: Featuring a taller cabin, larger doors, and compatibility for wheelchair users traveling alone. Simplified Mechanics: Using two sliding doors instead of Tesla’s three upward-opening doors. Improved Luggage Access: Positioning luggage space within the passenger cabin for convenience. These modifications are expected to increase fuel efficiency relative to Tesla’s model and reduce environmental impact, as discussed herein.
- 28 September 2024
- Published by Ninety Nine Publication in Journal of Advance Research in Food, Agriculture and Environmental Science (ISSN 2208-2417)
- Vol. 10 (3) , 26-30
Open AccessConceptual Proposal for Enhancing Autonomous Taxi Systems: A Focus on Tesla's Cybercab
This work provides a comparative analysis of Tesla's autonomous taxi model (referred to as robotaxi or Cybercab) and proposes a new design focused on enhancing efficiency and accessibility. Previous studies have examined efficiency differences between internal combustion engine (ICE) vehicles and electric cars, as well as the specific requirements of city taxis compared to high-speed vehicles, concluding that a specialized design could yield more efficient electric taxis. Our proposed robotaxi concept aims to address several limitations in Tesla’s design, including: Increased Passenger Capacity: Expanding seating from 2 to 4 passengers. Enhanced Accessibility: Featuring a taller cabin, larger doors, and compatibility for wheelchair users traveling alone. Simplified Mechanics: Using two sliding doors instead of Tesla’s three upward-opening doors. Improved Luggage Access: Positioning luggage space within the passenger cabin for convenience. These modifications are expected to increase fuel efficiency relative to Tesla’s model and reduce environmental impact, as discussed herein.
- Open Access
- 8 June 2022
- Published by IntechOpen
Holistic and Affordable Approach to Supporting the Sustainability of Family Houses in Cold Climates by Using Many Vacuum-Tube Solar Collectors and Small Water Tank to Provide the Sanitary Hot Water, Space Heating, Greenhouse, and Swimming Poole Heating De
This work presents a new proposal for supporting the sustainability of a single-family house in very cold climates by installing many vacuum-tube solar collectors and a small water tank in order to fulfill the whole dweller demands of heat: space heating, sanitary hot water, and warming both, a greenhouse (spring and autumn) and a swimming pool (summer). This way is obtained a sustained demand that maximizes the utilization of heat from solar collectors throughout the year. This system is designed intending to use the smallest tank that fulfills the winter heating demand, supported by vacuum-tube solar collectors and a little help from electrical heaters working just on the valley tariff. This innovative design gets the most sustainable (but affordable) solution. This goal can be achieved by using a small well-insulated overheated aboveground water tank, instead of the huge underground reservoir of heat used by most projects tested up today. These large communal projects use huge reservoirs to provide seasonal thermal storage (STES) capacity, but their costs are huge too. Besides, it was observed that all these huge STES suffer large heat losses (about 40%), due to constraints for thermally insulating such very heavy systems. On the contrary, our small aboveground water tank can be thermally insulated very well and gets affordable costs. In this work is developed dynamical solar-thermal modeling for studying this novel approach and are discussed its major differences with traditional design. This modeling is used to study the whole demands of heat for one family living in the same conditions of the Okotoks’ project. The Okotoks’ project is based on many flat solar collectors (2,290 m2) and a huge (2,800 m3) rocky-underground STES system in order to almost fulfill (97%) the space heating demand of 52 houses (15,795 kWh/y ea.) in Alberta (Canada), having an overall cost of 9 MU$ (173,000 U$ ea.). We have already shown in previous work that this new proposal could reach noticeably lower costs (€30,500) than the Okotoks’ project in order to provide the same heating demand, by taking advantage of using 18 vacuum-tube collectors (solar area 37 m2) and a small (72 m3) well-insulated (heat losses 18%) water tank heated up to 85°C, which is the same temperature used in Okotoks and other traditional projects. Now, this proposal is enhanced by using a holistic approach to include other low-temperature demands (sanitary hot water and warming a greenhouse and swimming pool) that enhance the sustainability of dweller living. This way, the full production of heat from solar collectors is utilized (about six times larger than the single space heating demand, but using only 20 vacuum-tube solar collectors (21 m2 solar area) and a very small (10m3) water tank, reaching about a lower overall cost (€20,000), and so, the economic performance is enhanced as well. Besides, it is shown that using a small fraction of electrical heaters as a backup system (2%) and slightly overheating the water (up to 120°C@2 bar), which is feasible by using commercial stainless steel water tanks designed for such purposes, its economic performance could be again noticeably enhanced (reducing the overall cost to €20,000, and getting payback period less than two years). This way here is demonstrated the overall solar-STES system can be reduced by about half size meanwhile the energy output can be increased up to seven times. Hence, the thermal analysis performed suggested us strongly critic the traditional approach of using flat solar collectors instead of vacuum-tube collectors. This analysis shows that this choice has strongly driven the selection of a huge STES, which in turn increases noticeably the overall costs of the system since for such huge STES is mandatory to use underground reservoirs. However, this analysis also shows that without including those secondary demands, this proposal achieves a modest economic performance (payback period about 11 years) regarding its lower energy saved and compared against the “most smart” standard solution (one water tank with electrical heaters, costing about 5,000 U$ and exploiting the valley tariff of nocturnal electricity costing 0.1 €/kWh). On the contrary, when these secondary demands are included, the payback period is reduced by two years. Beyond the particular case studied here, this analysis suggests that the right design of any solar + STES system should be led by the solar production. On the contrary, the traditional design intends to fulfill one demand (space heating) concentrated during winter, and so, its performance is noticeably penalized, and the solution is definitely not to put a larger tank. Unfortunately, up today the poor performance of these projects has shown that this solar technology is (by far) unaffordable. Maybe its best days have gone, considering the enormous improvements achieved by another solar technology (using photovoltaic panels + heat pump + small daily-storage water tank), as it was discussed here.
- 8 June 2022
- Published by IntechOpen
Open AccessHolistic and Affordable Approach to Supporting the Sustainability of Family Houses in Cold Climates by Using Many Vacuum-Tube Solar Collectors and Small Water Tank to Provide the Sanitary Hot Water, Space Heating, Greenhouse, and Swimming Poole Heating De
This work presents a new proposal for supporting the sustainability of a single-family house in very cold climates by installing many vacuum-tube solar collectors and a small water tank in order to fulfill the whole dweller demands of heat: space heating, sanitary hot water, and warming both, a greenhouse (spring and autumn) and a swimming pool (summer). This way is obtained a sustained demand that maximizes the utilization of heat from solar collectors throughout the year. This system is designed intending to use the smallest tank that fulfills the winter heating demand, supported by vacuum-tube solar collectors and a little help from electrical heaters working just on the valley tariff. This innovative design gets the most sustainable (but affordable) solution. This goal can be achieved by using a small well-insulated overheated aboveground water tank, instead of the huge underground reservoir of heat used by most projects tested up today. These large communal projects use huge reservoirs to provide seasonal thermal storage (STES) capacity, but their costs are huge too. Besides, it was observed that all these huge STES suffer large heat losses (about 40%), due to constraints for thermally insulating such very heavy systems. On the contrary, our small aboveground water tank can be thermally insulated very well and gets affordable costs. In this work is developed dynamical solar-thermal modeling for studying this novel approach and are discussed its major differences with traditional design. This modeling is used to study the whole demands of heat for one family living in the same conditions of the Okotoks’ project. The Okotoks’ project is based on many flat solar collectors (2,290 m2) and a huge (2,800 m3) rocky-underground STES system in order to almost fulfill (97%) the space heating demand of 52 houses (15,795 kWh/y ea.) in Alberta (Canada), having an overall cost of 9 MU$ (173,000 U$ ea.). We have already shown in previous work that this new proposal could reach noticeably lower costs (€30,500) than the Okotoks’ project in order to provide the same heating demand, by taking advantage of using 18 vacuum-tube collectors (solar area 37 m2) and a small (72 m3) well-insulated (heat losses 18%) water tank heated up to 85°C, which is the same temperature used in Okotoks and other traditional projects. Now, this proposal is enhanced by using a holistic approach to include other low-temperature demands (sanitary hot water and warming a greenhouse and swimming pool) that enhance the sustainability of dweller living. This way, the full production of heat from solar collectors is utilized (about six times larger than the single space heating demand, but using only 20 vacuum-tube solar collectors (21 m2 solar area) and a very small (10m3) water tank, reaching about a lower overall cost (€20,000), and so, the economic performance is enhanced as well. Besides, it is shown that using a small fraction of electrical heaters as a backup system (2%) and slightly overheating the water (up to 120°C@2 bar), which is feasible by using commercial stainless steel water tanks designed for such purposes, its economic performance could be again noticeably enhanced (reducing the overall cost to €20,000, and getting payback period less than two years). This way here is demonstrated the overall solar-STES system can be reduced by about half size meanwhile the energy output can be increased up to seven times. Hence, the thermal analysis performed suggested us strongly critic the traditional approach of using flat solar collectors instead of vacuum-tube collectors. This analysis shows that this choice has strongly driven the selection of a huge STES, which in turn increases noticeably the overall costs of the system since for such huge STES is mandatory to use underground reservoirs. However, this analysis also shows that without including those secondary demands, this proposal achieves a modest economic performance (payback period about 11 years) regarding its lower energy saved and compared against the “most smart” standard solution (one water tank with electrical heaters, costing about 5,000 U$ and exploiting the valley tariff of nocturnal electricity costing 0.1 €/kWh). On the contrary, when these secondary demands are included, the payback period is reduced by two years. Beyond the particular case studied here, this analysis suggests that the right design of any solar + STES system should be led by the solar production. On the contrary, the traditional design intends to fulfill one demand (space heating) concentrated during winter, and so, its performance is noticeably penalized, and the solution is definitely not to put a larger tank. Unfortunately, up today the poor performance of these projects has shown that this solar technology is (by far) unaffordable. Maybe its best days have gone, considering the enormous improvements achieved by another solar technology (using photovoltaic panels + heat pump + small daily-storage water tank), as it was discussed here.
- Open Access
- 1 January 2022
- Published by Corporacion Universitaria Remington in Revista Tecnica De La Facultad De Ingenieria Universidad Del Zulia
- Vol. 45 (1) , 58-68
Evaluación Energética y Económica de Calefacción de Hogares por Bomba de Calor en Bariloche, Montevideo y Santiago
El cambio climático obliga a mejorar la eficiencia del consumo de energía. En este trabajo se desarrolla una metodología de evaluación energética y económica de las ventajas de sustituir sistemas de calefacción tradicionales de gas natural, GLP, o electricidad, por una moderna bomba de calor (inverter). Al ser su eficiencia función de la diferencia de temperaturas entre el ambiente exterior y el interior, la eficiencia varía según la ubicación de la ciudad. De esta manera, se estudia su rendimiento en Bariloche, Santiago de Chile y Montevideo (temperatura media anual de 8,3; 14,6 y 16,3 °C, respectivamente), empleando los siguientes sistemas: 1) aire-aire, instalando varios equipos Split; y 2) aire-agua, instalando una bomba de calor que brinde calefacción por radiadores de agua. Esta metodología permite dimensionar estos sistemas y calcular el ahorro anual, ejemplificándose para una vivienda social de 50 m2. En todos los casos estudiados se alcanzaron reducciones de los consumos y ahorros de moderados a notables (y períodos de repago de la inversión menores a dos años), excepto contra el gas natural en Bariloche y Montevideo. Se discute también cómo su inversión moderada puede constituir una primera solución asequible, frente a la costosa rehabilitación térmica, a fin de obtener viviendas más sustentables.
- 1 January 2022
- Published by Corporacion Universitaria Remington in Revista Tecnica De La Facultad De Ingenieria Universidad Del Zulia
- Vol. 45 (1) , 58-68
Open AccessEvaluación Energética y Económica de Calefacción de Hogares por Bomba de Calor en Bariloche, Montevideo y Santiago
El cambio climático obliga a mejorar la eficiencia del consumo de energía. En este trabajo se desarrolla una metodología de evaluación energética y económica de las ventajas de sustituir sistemas de calefacción tradicionales de gas natural, GLP, o electricidad, por una moderna bomba de calor (inverter). Al ser su eficiencia función de la diferencia de temperaturas entre el ambiente exterior y el interior, la eficiencia varía según la ubicación de la ciudad. De esta manera, se estudia su rendimiento en Bariloche, Santiago de Chile y Montevideo (temperatura media anual de 8,3; 14,6 y 16,3 °C, respectivamente), empleando los siguientes sistemas: 1) aire-aire, instalando varios equipos Split; y 2) aire-agua, instalando una bomba de calor que brinde calefacción por radiadores de agua. Esta metodología permite dimensionar estos sistemas y calcular el ahorro anual, ejemplificándose para una vivienda social de 50 m2. En todos los casos estudiados se alcanzaron reducciones de los consumos y ahorros de moderados a notables (y períodos de repago de la inversión menores a dos años), excepto contra el gas natural en Bariloche y Montevideo. Se discute también cómo su inversión moderada puede constituir una primera solución asequible, frente a la costosa rehabilitación térmica, a fin de obtener viviendas más sustentables.
- Open Access
- 10 May 2020
- Published by Fundacion Universidad de Palermo in Ciencia y Tecnología
Estrategias de Ahorro Energético en Hogares: ¿Termotanque Eléctrico o Gas?
Se presentan novedosas estrategias de ahorro energético utilizando termotanques eléctricos hogareños con las que obtenienen ahorros significativos, desde 675 kWh/año para un único usuario hasta 2.490 kWh/año para una familia de siete miembros, que se traducen (tarifa 3 $/kWh) en $2.000 y $7.500 al año. Instalando tres termotanques: uno compacto 20 litros en cocina a 50 °C, otro de 50 litros a 45 °C en un baño, ambos con reloj programador y desconección nocturna, y otro de 150 litros en otro baño (apagado y con encendido remoto) el consumo anual de esta familia se reduce a $14.000 contra $21.500 de la configuración básica (un termotanque 150 litros siempre a 75 °C). Se discute la conveniencia del uso de termotanques eléctricos o gas (natural o envasado). El costo anual de combustible con gas natural (4 $/m3) o envasado (50 $/kg) para esta familia asciende a $4.400 y $55.000, respectivamente; no obstante incluyendo otros costos asociados (mantenimiento y seguridad, $12.500 anuales) la comparación favorece a la mejor opción eléctrica. Esta conclusión podría cambiar el paradigma a favor del gas natural en hogares, y concientizaría sobre sus riesgos.
- 10 May 2020
- Published by Fundacion Universidad de Palermo in Ciencia y Tecnología
Open AccessEstrategias de Ahorro Energético en Hogares: ¿Termotanque Eléctrico o Gas?
Se presentan novedosas estrategias de ahorro energético utilizando termotanques eléctricos hogareños con las que obtenienen ahorros significativos, desde 675 kWh/año para un único usuario hasta 2.490 kWh/año para una familia de siete miembros, que se traducen (tarifa 3 $/kWh) en $2.000 y $7.500 al año. Instalando tres termotanques: uno compacto 20 litros en cocina a 50 °C, otro de 50 litros a 45 °C en un baño, ambos con reloj programador y desconección nocturna, y otro de 150 litros en otro baño (apagado y con encendido remoto) el consumo anual de esta familia se reduce a $14.000 contra $21.500 de la configuración básica (un termotanque 150 litros siempre a 75 °C). Se discute la conveniencia del uso de termotanques eléctricos o gas (natural o envasado). El costo anual de combustible con gas natural (4 $/m3) o envasado (50 $/kg) para esta familia asciende a $4.400 y $55.000, respectivamente; no obstante incluyendo otros costos asociados (mantenimiento y seguridad, $12.500 anuales) la comparación favorece a la mejor opción eléctrica. Esta conclusión podría cambiar el paradigma a favor del gas natural en hogares, y concientizaría sobre sus riesgos.