Zheng Yuan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Zheng Yuan has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
Bo Deng
China Academy of Engineering Physics 1 Research Center of Laser Fusion Mianyang, Sichuan 621900, China
2 shared publicationsBo Qing
Research Center of Laser Fusion, China Academy of Engineering Physics 1 , Mianyang 621900, China
2 shared publicationsChengwu Huang
Research Center of Laser Fusion, China Academy of Engineering Physics 1 , Mianyang 621900, China
2 shared publicationsDong Yang
Research Center of Laser Fusion, China Academy of Engineering Physics 1 , Mianyang 621900, China
2 shared publicationsGuohong Yang
Research Center of Laser Fusion, China Academy of Engineering Physics 1 , Mianyang 621900, China
2 shared publicationsJiyan Zhang
Research Center of Laser Fusion, China Academy of Engineering Physics 1 , Mianyang 621900, China
2 shared publications
Latest Publications
- Open Access
- 12 September 2025
- Published by Association for Computing Machinery (ACM)
- p. 1741-1746
Athlete Injury Prediction: A Time Series Forecasting Method Based on Wearable Sensor Data and Deep Learning
- 12 September 2025
- Published by Association for Computing Machinery (ACM)
- p. 1741-1746
Open AccessAthlete Injury Prediction: A Time Series Forecasting Method Based on Wearable Sensor Data and Deep Learning
- 1 June 2021
- Published by AIP Publishing in Physics of Plasmas
- Vol. 28 (6) , 062707
Multi-keV x-ray radiator from titanium cylindrical cavity at the Shenguang-III prototype laser facility
Great efforts have been made to create a bright K-shell source using the thin metal cylindrical cavities in the past few decades. Several metal materials such as titanium (Ti), iron, and so on have been tested for high x-ray conversion efficiency mainly at the OMEGA and NIF laser facilities. Recently, x-ray sources in Ti K-shell transition energy range were investigated at the Shenguang-III prototype laser facility with ∼5 kJ laser energy. The experiments were aimed to reproduce the previous ones at OMEGA, but with an extraordinarily small volume of cylindrical cavity and detailed characterizations of the x-ray source. The cavities were 800 μm inner diameter, 800 μm length, and 30 μm thick plastic tubes supporting 1 μm thick Ti. Seven laser beams were focused to 200 μm diameter. The combination of the small cavity volume and the focused laser spots is intended to improve the electron temperature with limited laser energy since the electron temperature is a key issue for high x-ray conversion efficiency. Thomson scattering was adopted to experimentally probe the electron temperatures at special time and space zones as well as the average temperature obtained from the Ti K-shell spectrum. The evolutions of the electron temperature and density are predicted by the radiation hydrodynamic simulation. A top view and two photon energy bands of x-ray source images provide a way to directly observe the plasma movement toward the cavity axis and distinguish the different emission mechanisms between the Ti K-shell and lower energy x rays. Six Higher-energy x-ray detectors located at different angles were used to record the Ti K-shell x-ray emission and demonstrate its isotropic feature. The characteristics of the x-ray radiate intensity including the time evolution, the angular distribution, and the total yields for both the photon energy regions above and below 4 keV are compared between the cavity and planar targets. Obviously, different behaviors were found between the two photon energy regions and the two types of targets. The x-ray conversion efficiency of the Ti cylinder was determined to be and in sr in the Ti K-shell (4–7 keV) and <4 keV range, respectively. The Ti K-shell conversion efficiency obtained in the present experiments is between the ones driven by 13.5 and 4.5 kJ laser energy at OMEGA.- 1 June 2021
- Published by AIP Publishing in Physics of Plasmas
- Vol. 28 (6) , 062707
Multi-keV x-ray radiator from titanium cylindrical cavity at the Shenguang-III prototype laser facility
Great efforts have been made to create a bright K-shell source using the thin metal cylindrical cavities in the past few decades. Several metal materials such as titanium (Ti), iron, and so on have been tested for high x-ray conversion efficiency mainly at the OMEGA and NIF laser facilities. Recently, x-ray sources in Ti K-shell transition energy range were investigated at the Shenguang-III prototype laser facility with ∼5 kJ laser energy. The experiments were aimed to reproduce the previous ones at OMEGA, but with an extraordinarily small volume of cylindrical cavity and detailed characterizations of the x-ray source. The cavities were 800 μm inner diameter, 800 μm length, and 30 μm thick plastic tubes supporting 1 μm thick Ti. Seven laser beams were focused to 200 μm diameter. The combination of the small cavity volume and the focused laser spots is intended to improve the electron temperature with limited laser energy since the electron temperature is a key issue for high x-ray conversion efficiency. Thomson scattering was adopted to experimentally probe the electron temperatures at special time and space zones as well as the average temperature obtained from the Ti K-shell spectrum. The evolutions of the electron temperature and density are predicted by the radiation hydrodynamic simulation. A top view and two photon energy bands of x-ray source images provide a way to directly observe the plasma movement toward the cavity axis and distinguish the different emission mechanisms between the Ti K-shell and lower energy x rays. Six Higher-energy x-ray detectors located at different angles were used to record the Ti K-shell x-ray emission and demonstrate its isotropic feature. The characteristics of the x-ray radiate intensity including the time evolution, the angular distribution, and the total yields for both the photon energy regions above and below 4 keV are compared between the cavity and planar targets. Obviously, different behaviors were found between the two photon energy regions and the two types of targets. The x-ray conversion efficiency of the Ti cylinder was determined to be and in sr in the Ti K-shell (4–7 keV) and <4 keV range, respectively. The Ti K-shell conversion efficiency obtained in the present experiments is between the ones driven by 13.5 and 4.5 kJ laser energy at OMEGA.- 1 July 2017
- Published by AIP Publishing in Physics of Plasmas
- Vol. 24 (7) , 072711
Comparison of the laser spot movement inside cylindrical and spherical hohlraums
Compared with cylindrical hohlraums, the octahedral spherical hohlraums have natural superiority in maintaining high radiation symmetry during the whole capsule implosion process in indirect drive inertial confinement fusion. However, the narrow space between laser beams and the hohlraum wall may disturb laser propagation inside the spherical hohlraum. In this work, the laser propagation inside the spherical hohlraum and cylindrical hohlraum is investigated experimentally by measuring laser spot movement at the SGIII-prototype laser facility. The experimental results show that the laser propagations inside the spherical hohlraum and the cylindrical hohlraum are totally different from each other due to different hohlraum structures. For the spherical hohlraum, although the laser energy is mainly deposited in the initial position of the laser spot during the whole laser pulse, some laser energies are absorbed by the ablated plasmas from the hohlraum wall. Because the laser beam is refracted by the thin plasmas near the laser entrance hole (LEH) region, the laser spot in the spherical hohlraum moves toward the opposite LEH. In contrast, the laser spot in the cylindrical hohlraum moves toward the LEH along the laser path due to the plasma expansion. When the laser is to be turned off, the accumulated plasmas near the LEH region in the cylindrical hohlraum absorb a majority of laser energy and hinder the laser arriving at the appointed position on the hohlraum wall.
- 1 July 2017
- Published by AIP Publishing in Physics of Plasmas
- Vol. 24 (7) , 072711
Comparison of the laser spot movement inside cylindrical and spherical hohlraums
Compared with cylindrical hohlraums, the octahedral spherical hohlraums have natural superiority in maintaining high radiation symmetry during the whole capsule implosion process in indirect drive inertial confinement fusion. However, the narrow space between laser beams and the hohlraum wall may disturb laser propagation inside the spherical hohlraum. In this work, the laser propagation inside the spherical hohlraum and cylindrical hohlraum is investigated experimentally by measuring laser spot movement at the SGIII-prototype laser facility. The experimental results show that the laser propagations inside the spherical hohlraum and the cylindrical hohlraum are totally different from each other due to different hohlraum structures. For the spherical hohlraum, although the laser energy is mainly deposited in the initial position of the laser spot during the whole laser pulse, some laser energies are absorbed by the ablated plasmas from the hohlraum wall. Because the laser beam is refracted by the thin plasmas near the laser entrance hole (LEH) region, the laser spot in the spherical hohlraum moves toward the opposite LEH. In contrast, the laser spot in the cylindrical hohlraum moves toward the LEH along the laser path due to the plasma expansion. When the laser is to be turned off, the accumulated plasmas near the LEH region in the cylindrical hohlraum absorb a majority of laser energy and hinder the laser arriving at the appointed position on the hohlraum wall.
- 1 November 2016
- Published by AIP Publishing in Physics of Plasmas
- Vol. 23 (11) , 112707
Fluorescence based imaging for M-band drive symmetry measurement in hohlraum
We describe an experimental technique to measure the drive symmetry of M-band radiation on the capsule in hohlraum. M-band radiation from the corona of the laser-produced gold plasma, especially the laser spot regions in the cavity, was used to pump x-ray fluorescence of a thin layer of Si-tracer coated on a solid CH-ball. The fluorescence images were time resolvedly recorded by an x-ray framing camera and the drive asymmetry due to M-band radiation was deduced from these fluorescence images. Moreover, a Si-doped gold cavity was used with the initial purpose of maximizing the fluorescence signal through resonance transitions. Since the Si-plasma expands more rapidly than the gold-plasma, the evolution of drive asymmetry was accelerated in Si-doped hohlraum.
- 1 November 2016
- Published by AIP Publishing in Physics of Plasmas
- Vol. 23 (11) , 112707
Fluorescence based imaging for M-band drive symmetry measurement in hohlraum
We describe an experimental technique to measure the drive symmetry of M-band radiation on the capsule in hohlraum. M-band radiation from the corona of the laser-produced gold plasma, especially the laser spot regions in the cavity, was used to pump x-ray fluorescence of a thin layer of Si-tracer coated on a solid CH-ball. The fluorescence images were time resolvedly recorded by an x-ray framing camera and the drive asymmetry due to M-band radiation was deduced from these fluorescence images. Moreover, a Si-doped gold cavity was used with the initial purpose of maximizing the fluorescence signal through resonance transitions. Since the Si-plasma expands more rapidly than the gold-plasma, the evolution of drive asymmetry was accelerated in Si-doped hohlraum.
- 1 July 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (7) , 073303
Three-dimensional particle-in-cell simulation on gain saturation effect of microchannel plate
We present here the results of the simulation work, using the three-dimensional particle-in-cell method, on the performance of the lead glass microchannel plate under saturated state. We calculated the electron cascade process with different DC bias voltages under both self-consistent condition and non-self-consistent condition. The comparative results have demonstrated that the strong self-consistent field can suppress the cascade process and make the microchannel plate saturated. The simulation results were also compared to the experimental data and good agreement was obtained. The simulation results also show that the electron multiplication process in the channel is accompanied by the buildup process of positive charges in the channel wall. Though the interactions among the secondary electron cloud in the channel, the positive charges in the channel wall, and the external acceleration field can make the electron-surface collision more frequent, the collision energy will be inevitably reduced, thus the electron gain will also be reduced.
- 1 July 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (7) , 073303
Three-dimensional particle-in-cell simulation on gain saturation effect of microchannel plate
We present here the results of the simulation work, using the three-dimensional particle-in-cell method, on the performance of the lead glass microchannel plate under saturated state. We calculated the electron cascade process with different DC bias voltages under both self-consistent condition and non-self-consistent condition. The comparative results have demonstrated that the strong self-consistent field can suppress the cascade process and make the microchannel plate saturated. The simulation results were also compared to the experimental data and good agreement was obtained. The simulation results also show that the electron multiplication process in the channel is accompanied by the buildup process of positive charges in the channel wall. Though the interactions among the secondary electron cloud in the channel, the positive charges in the channel wall, and the external acceleration field can make the electron-surface collision more frequent, the collision energy will be inevitably reduced, thus the electron gain will also be reduced.