Vuk Milošević
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Vuk Milošević has a total of 86 co-authors. Here are the top co-authors by number of shared publications:
- Dragan Kostic
Faculty of Civil Engineering and Architecture, University of Niš, Niš, Serbia
9 shared publications - Janusz Marchwiński
University of Technology and Arts in Applied Sciences in Warsaw Faculty of Architecture
7 shared publications - Miomir Vasov
Faculty of Civil Engineering and Architecture, University of Niš, 18000 Niš, Serbia
6 shared publications - Agnieszka Starzyk
Institute of Civil Engineering, Warsaw University of Life Sciences, Nowoursynowska 166, 02-776 Warsaw, Poland
4 shared publications Biserka Marković
Faculty of Civil Engineering and Architecture, University of Niš, Niš 18000, Serbia
3 shared publications- Dušan Ranđelović
Faculty of Civil Engineering and Architecture, University of Niš, 18000 Niš, Serbia
3 shared publications
Latest Publications
- Open Access
- 4 November 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (21) , 10918
Computational Decision Support for Historic Hospital Adaptive Reuse: Development and Internal Verification of HARP v1.1
The adaptive reuse of historic hospitals requires comparing prospective functions against inherited architectural configurations, heritage constraints and contextual conditions, often under incomplete documentation. This study develops and internally verifies HARP v1.1, a hospital-specific rule-based decision-support framework designed to make preliminary reuse assessments transparent and traceable. Drawing on 43 comparative cases, 15 supplementary cases and iterative architectural modelling, the framework connects evidence-supported inputs, derived indicators and conditional rules to eight prospective reuse directions. Rule-normalised compatibility scores are reported separately from Evidence Adequacy. The original 19 software-conformance tests were passed, and deterministic replay reproduced the Pirot reference assessment. Mixed Use ranked first in the reference assessment, while sensitivity analyses and alternative scoring controls identified modelling dependencies that could have affected the rankings. The developmental coding pilot informed protocol refinement; a separate, focused, independent-coder check of the final 35 inputs for Pirot yielded 32/35 exact agreements (91.4%; unweighted Cohen’s κ = 0.859), with three one-level disagreements. The findings demonstrate the implementation consistency and reproducibility of the reference assessment, while the framework’s traceable computational structure supports the inspection of its assumptions and dependencies. Further evaluation across independent assessments and additional hospital cases is needed. HARP v1.1 is proposed as a research prototype for preliminary architectural screening and briefing, rather than as a validated predictor of optimal reuse.
- 4 November 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (21) , 10918
Open AccessComputational Decision Support for Historic Hospital Adaptive Reuse: Development and Internal Verification of HARP v1.1
The adaptive reuse of historic hospitals requires comparing prospective functions against inherited architectural configurations, heritage constraints and contextual conditions, often under incomplete documentation. This study develops and internally verifies HARP v1.1, a hospital-specific rule-based decision-support framework designed to make preliminary reuse assessments transparent and traceable. Drawing on 43 comparative cases, 15 supplementary cases and iterative architectural modelling, the framework connects evidence-supported inputs, derived indicators and conditional rules to eight prospective reuse directions. Rule-normalised compatibility scores are reported separately from Evidence Adequacy. The original 19 software-conformance tests were passed, and deterministic replay reproduced the Pirot reference assessment. Mixed Use ranked first in the reference assessment, while sensitivity analyses and alternative scoring controls identified modelling dependencies that could have affected the rankings. The developmental coding pilot informed protocol refinement; a separate, focused, independent-coder check of the final 35 inputs for Pirot yielded 32/35 exact agreements (91.4%; unweighted Cohen’s κ = 0.859), with three one-level disagreements. The findings demonstrate the implementation consistency and reproducibility of the reference assessment, while the framework’s traceable computational structure supports the inspection of its assumptions and dependencies. Further evaluation across independent assessments and additional hospital cases is needed. HARP v1.1 is proposed as a research prototype for preliminary architectural screening and briefing, rather than as a validated predictor of optimal reuse.
- Open Access
- 15 October 2026
- Published by Elsevier in Construction and Building Materials
- Vol. 546
Circularity index analysis of buildings with different structural materials: a modelling approach for sustainable construction assessment
- 15 October 2026
- Published by Elsevier in Construction and Building Materials
- Vol. 546
Open AccessCircularity index analysis of buildings with different structural materials: a modelling approach for sustainable construction assessment
- Open Access
Climate-Specific Performance of Textile Membrane Sports Halls: Energy Efficiency, Comfort, and Economic Assessment via EnergyPlus
Textile membrane systems are increasingly used in sports halls because of their low structural weight, rapid assembly, and ability to span large areas. Their operational performance, however, is strongly affected by local climate conditions, envelope configuration and the limited thermal inertia of membrane materials. This study presents a comparative EnergyPlus-based assessment of textile membrane sports halls in six representative climate contexts: Helsinki, Berlin, Niš, Barcelona, Dawadmi and Bangkok. A conventional masonry hall was used as the reference case and compared with a single-layer PVC-coated polyester membrane system and double-layer membrane systems with air gaps of 0.4, 0.5 and 0.6 m, including mechanically ventilated air-cavity variants. The assessment combines four performance indicators: annual operational energy demand, carbon emissions, indicative global cost and thermal comfort expressed through Fanger’s Predicted Percentage of Dissatisfied (PPD) index. The results show that the dominant energy demand is climate-dependent, with heating prevailing in cold climates and cooling becoming decisive in hot-arid and hot-humid climates. Double-layer cases usually show lower operational energy demand and lower associated carbon dioxide emissions than the single-layer membrane case. This improvement, however, is not uniform; it depends on the climatic setting and on the width of the air gap. The comfort results lead to a similar but more limited conclusion. Although PPD is reduced in the double-layer configurations, the values remain above conventional comfort acceptance levels in all tested cases. The double-layer membrane should therefore be understood as a measure that reduces thermal dissatisfaction, not as a complete comfort solution. The economic assessment indicates that membrane systems have substantially lower initial capital costs than masonry construction, while their long-term performance depends on operational energy costs, membrane replacement assumptions and the selected analysis horizon. The study provides a climate-specific comparative framework for early-stage envelope selection in textile membrane sports halls, emphasizing that energy demand, carbon emissions, cost and thermal comfort should be considered together rather than as separate outputs.
Open AccessClimate-Specific Performance of Textile Membrane Sports Halls: Energy Efficiency, Comfort, and Economic Assessment via EnergyPlus
Textile membrane systems are increasingly used in sports halls because of their low structural weight, rapid assembly, and ability to span large areas. Their operational performance, however, is strongly affected by local climate conditions, envelope configuration and the limited thermal inertia of membrane materials. This study presents a comparative EnergyPlus-based assessment of textile membrane sports halls in six representative climate contexts: Helsinki, Berlin, Niš, Barcelona, Dawadmi and Bangkok. A conventional masonry hall was used as the reference case and compared with a single-layer PVC-coated polyester membrane system and double-layer membrane systems with air gaps of 0.4, 0.5 and 0.6 m, including mechanically ventilated air-cavity variants. The assessment combines four performance indicators: annual operational energy demand, carbon emissions, indicative global cost and thermal comfort expressed through Fanger’s Predicted Percentage of Dissatisfied (PPD) index. The results show that the dominant energy demand is climate-dependent, with heating prevailing in cold climates and cooling becoming decisive in hot-arid and hot-humid climates. Double-layer cases usually show lower operational energy demand and lower associated carbon dioxide emissions than the single-layer membrane case. This improvement, however, is not uniform; it depends on the climatic setting and on the width of the air gap. The comfort results lead to a similar but more limited conclusion. Although PPD is reduced in the double-layer configurations, the values remain above conventional comfort acceptance levels in all tested cases. The double-layer membrane should therefore be understood as a measure that reduces thermal dissatisfaction, not as a complete comfort solution. The economic assessment indicates that membrane systems have substantially lower initial capital costs than masonry construction, while their long-term performance depends on operational energy costs, membrane replacement assumptions and the selected analysis horizon. The study provides a climate-specific comparative framework for early-stage envelope selection in textile membrane sports halls, emphasizing that energy demand, carbon emissions, cost and thermal comfort should be considered together rather than as separate outputs.
- Open Access
- 1 June 2026
- Published by University of Banja Luka, Faculty of Architecture, Civil Engineering and Geodesy
- Vol. 17 (1) , 245-254
THERMAL MEASUREMENTS ON A MEMBRANE-COVERED SPORTS FACILITY: CASE STUDY IN NIŠ, SERBIA
There are numerous membrane-covered sports facilities in Niš. They have become popular over the last two decades due to their low cost and rapid construction. However, they are known to provide poor indoor thermal conditions, and methods for improving their performance are still being investigated. This research forms part of that effort. A typical membrane-covered facility, the physical education hall of Ivan Goran Kovačić School in Niš, was selected for analysis. Several thermal parameters were measured during a hot summer day. The results confirmed some findings reported in previous research, but also contradicted certain expectations. The conclusions of this study will be used to propose improved thermal solutions for membrane-covered sports facilities.
- 1 June 2026
- Published by University of Banja Luka, Faculty of Architecture, Civil Engineering and Geodesy
- Vol. 17 (1) , 245-254
Open AccessTHERMAL MEASUREMENTS ON A MEMBRANE-COVERED SPORTS FACILITY: CASE STUDY IN NIŠ, SERBIA
There are numerous membrane-covered sports facilities in Niš. They have become popular over the last two decades due to their low cost and rapid construction. However, they are known to provide poor indoor thermal conditions, and methods for improving their performance are still being investigated. This research forms part of that effort. A typical membrane-covered facility, the physical education hall of Ivan Goran Kovačić School in Niš, was selected for analysis. Several thermal parameters were measured during a hot summer day. The results confirmed some findings reported in previous research, but also contradicted certain expectations. The conclusions of this study will be used to propose improved thermal solutions for membrane-covered sports facilities.
- Open Access
- 1 June 2026
- Published by University of Banja Luka, Faculty of Architecture, Civil Engineering and Geodesy
- Vol. 17 (1) , 81-90
DEVELOPING A CFD NUMERICAL MODEL FOR WIND ANALYSIS OF BUILDINGS WITH ARCHED ROOF
Wind action on engineering structures can cause significant consequences. Arched structures covered with textile membranes (balloon halls) are particularly vulnerable. This paper presents a study of wind action on structures with arched roofs and flat gable walls. The analysis was conducted using Computational Fluid Dynamics (CFD), with variations in parameters that may influence structural response, for two representative wind directions: along-wind and crosswind. The selected output parameter, the pressure coefficient (Cp), is validated and compared with values provided in relevant standards. The aim of this research is to contribute to the dissemination of knowledge and experience related to CFD methodology, as well as to support the development of regulatory databases concerning pressure coefficients for non-standard structural forms.
- 1 June 2026
- Published by University of Banja Luka, Faculty of Architecture, Civil Engineering and Geodesy
- Vol. 17 (1) , 81-90
Open AccessDEVELOPING A CFD NUMERICAL MODEL FOR WIND ANALYSIS OF BUILDINGS WITH ARCHED ROOF
Wind action on engineering structures can cause significant consequences. Arched structures covered with textile membranes (balloon halls) are particularly vulnerable. This paper presents a study of wind action on structures with arched roofs and flat gable walls. The analysis was conducted using Computational Fluid Dynamics (CFD), with variations in parameters that may influence structural response, for two representative wind directions: along-wind and crosswind. The selected output parameter, the pressure coefficient (Cp), is validated and compared with values provided in relevant standards. The aim of this research is to contribute to the dissemination of knowledge and experience related to CFD methodology, as well as to support the development of regulatory databases concerning pressure coefficients for non-standard structural forms.
- Open Access
- 1 January 2026
- Published by Centre for Evaluation in Education and Science (CEON/CEES)
- No. Smart & cl,p. 583-591
An approach to smart daylight control in membrane-covered sports facilities
The importance of daylight for occupant health and well-being and requirements for reduction of energy consumption has led to the development of innovative and sustainable solutions. In recent years, membrane structures have become increasingly popular for covering sports halls, and various other facilities due to their high daylight transmittance, fast construction, and lightweight. Unlike conventional roofs (which are generally solid and opaque), membrane envelopes, particularly those made of high-performance membrane materials, offer the possibility of using natural daylight as a primary light source during building operation. However, unwanted daylight penetration can also cause visual discomfort, glare, and an increased load on the cooling system if not managed appropriately. Accordingly, integrating smart daylight control strategies with membrane-covered structures represents a promising approach to energy-efficient and sustainable sports facilities. Based on the literature, intelligent daylight management systems could be a promising solution for improving the performance of membrane-covered sports halls. The integration of real-time environmental monitoring with adaptive lighting control can enhance visual comfort, optimize daylight utilization, and reduce energy consumption. Studies indicate that smart daylighting strategies applied in membrane facilities provide significant potential for improving indoor environmental quality and promoting the sustainable design of sports facilities. Given that numerous membrane-covered sports facilities have become popular in the last two decades, it is necessary to become familiar with innovative possibilities for controlling the optimal use of daylight and consequently optimal energy consumption. In this context, the present study aims to provide a methodological foundation for the implementation and quantitative validation of intelligent lighting control strategies, based on sensing occupancy detection and lighting control, in both existing and newly constructed sports facilities with membrane roofing systems.
- 1 January 2026
- Published by Centre for Evaluation in Education and Science (CEON/CEES)
- No. Smart & cl,p. 583-591
Open AccessAn approach to smart daylight control in membrane-covered sports facilities
The importance of daylight for occupant health and well-being and requirements for reduction of energy consumption has led to the development of innovative and sustainable solutions. In recent years, membrane structures have become increasingly popular for covering sports halls, and various other facilities due to their high daylight transmittance, fast construction, and lightweight. Unlike conventional roofs (which are generally solid and opaque), membrane envelopes, particularly those made of high-performance membrane materials, offer the possibility of using natural daylight as a primary light source during building operation. However, unwanted daylight penetration can also cause visual discomfort, glare, and an increased load on the cooling system if not managed appropriately. Accordingly, integrating smart daylight control strategies with membrane-covered structures represents a promising approach to energy-efficient and sustainable sports facilities. Based on the literature, intelligent daylight management systems could be a promising solution for improving the performance of membrane-covered sports halls. The integration of real-time environmental monitoring with adaptive lighting control can enhance visual comfort, optimize daylight utilization, and reduce energy consumption. Studies indicate that smart daylighting strategies applied in membrane facilities provide significant potential for improving indoor environmental quality and promoting the sustainable design of sports facilities. Given that numerous membrane-covered sports facilities have become popular in the last two decades, it is necessary to become familiar with innovative possibilities for controlling the optimal use of daylight and consequently optimal energy consumption. In this context, the present study aims to provide a methodological foundation for the implementation and quantitative validation of intelligent lighting control strategies, based on sensing occupancy detection and lighting control, in both existing and newly constructed sports facilities with membrane roofing systems.
- Open Access
- 1 January 2026
- Published by Centre for Evaluation in Education and Science (CEON/CEES)
- No. Green buil,p. 319-328
Public-private partnerships for green infrastructure: The role of renewable energy
Financing green infrastructure requires arrangements capable of addressing high initial capital needs and long-term performance requirements. This paper examines the application of Public-Private Partnerships (PPPs) to renewable energy, energy-efficient buildings, and related forms of green infrastructure. The study combines a structured qualitative review of scientific and institutional sources with selected international and Serbian project cases. The analysis identifies risk allocation, life-cycle management, regulatory predictability, institutional capacity, and contractual design as important factors affecting PPP performance. International cases include energy-efficient public lighting, solar-energy development, and waste-to-energy infrastructure, while Serbian examples cover public-lighting and biomass-based heating projects in Niš, solar generation in Vranje, and the Vinča waste-management PPP in Belgrade. These applications are interpreted through an integrated conceptual framework linking infrastructure investment needs and project risks with PPP mechanisms and economic, environmental, and social outcomes. For Serbia, the findings also indicate potential for further application in public-building energy renovation, renewable-energy systems, low-carbon district heating, and urban green and blue infrastructure.
- 1 January 2026
- Published by Centre for Evaluation in Education and Science (CEON/CEES)
- No. Green buil,p. 319-328
Open AccessPublic-private partnerships for green infrastructure: The role of renewable energy
Financing green infrastructure requires arrangements capable of addressing high initial capital needs and long-term performance requirements. This paper examines the application of Public-Private Partnerships (PPPs) to renewable energy, energy-efficient buildings, and related forms of green infrastructure. The study combines a structured qualitative review of scientific and institutional sources with selected international and Serbian project cases. The analysis identifies risk allocation, life-cycle management, regulatory predictability, institutional capacity, and contractual design as important factors affecting PPP performance. International cases include energy-efficient public lighting, solar-energy development, and waste-to-energy infrastructure, while Serbian examples cover public-lighting and biomass-based heating projects in Niš, solar generation in Vranje, and the Vinča waste-management PPP in Belgrade. These applications are interpreted through an integrated conceptual framework linking infrastructure investment needs and project risks with PPP mechanisms and economic, environmental, and social outcomes. For Serbia, the findings also indicate potential for further application in public-building energy renovation, renewable-energy systems, low-carbon district heating, and urban green and blue infrastructure.
- Open Access
- 1 January 2026
- Published by National Library of Serbia in Thermal Science
- No. 00,p. 168
Field evaluation of thermal and daylight performance in membrane covered facility
Membrane structures have unique aesthetics and offer a potential to experiment with building forms and create new and captivating solutions for conventional designs. However, providing comfortable indoor conditions is mandatory to ensure maximal functionality, which can be specific in regard of the building function. This paper evaluates thermal and optical characteristics of membrane covered building. Measurements of weather parameters and indoor temperature and natural illumination levels in a PVC membrane-covered gym hall located near Nis were conducted. During the month of March, in two measuring points values of natural illumination exceeded 300lx for 47% and 58% of the time respectively. In measuring point 2, which was placed 2.6 meters higher than the measuring point 1, illumination was in average 27.7% higher. Average air temperature and operative temperature were below 18°C 74.68% and 76.39% of the time, respectively. The obtained results indicate that although membrane covered buildings have favorable optical characteristics, improvement of indoor thermal environment in them should be further investigated.
- 1 January 2026
- Published by National Library of Serbia in Thermal Science
- No. 00,p. 168
Open AccessField evaluation of thermal and daylight performance in membrane covered facility
Membrane structures have unique aesthetics and offer a potential to experiment with building forms and create new and captivating solutions for conventional designs. However, providing comfortable indoor conditions is mandatory to ensure maximal functionality, which can be specific in regard of the building function. This paper evaluates thermal and optical characteristics of membrane covered building. Measurements of weather parameters and indoor temperature and natural illumination levels in a PVC membrane-covered gym hall located near Nis were conducted. During the month of March, in two measuring points values of natural illumination exceeded 300lx for 47% and 58% of the time respectively. In measuring point 2, which was placed 2.6 meters higher than the measuring point 1, illumination was in average 27.7% higher. Average air temperature and operative temperature were below 18°C 74.68% and 76.39% of the time, respectively. The obtained results indicate that although membrane covered buildings have favorable optical characteristics, improvement of indoor thermal environment in them should be further investigated.
- Open Access
- 1 January 2026
- Published by Centre for Evaluation in Education and Science (CEON/CEES)
- No. Session II,p. 441-448
Review of existing textile-covered sports facilities in Niš, Serbia
Textile architecture in Serbia is predominantly present in its simpler forms. In most existing buildings, textile membranes are used only as a covering material, without the significant double curvature required to fully exploit their structural and architectural potential. This research focuses on sports facilities covered with textile membranes in the city of Niš. The aim of the study is to identify and systematize existing buildings of this typology. The results show that there are currently 20 such facilities in the wider area of the city. These facilities were visited, and relevant data were recorded and analyzed, with the results presented and discussed in this paper. In addition, six other textile-covered structures were identified but fall outside the scope of this research. These include four storage facilities, one protective cover for a historical site, and one canopy covering a restaurant garden. The analyzed textile structures exhibit significant diversity in several aspects, including ownership, structural system, permanence, and function. The findings of this study will be used to inform the development of improved textile cover designs for sports facilities in the region.
- 1 January 2026
- Published by Centre for Evaluation in Education and Science (CEON/CEES)
- No. Session II,p. 441-448
Open AccessReview of existing textile-covered sports facilities in Niš, Serbia
Textile architecture in Serbia is predominantly present in its simpler forms. In most existing buildings, textile membranes are used only as a covering material, without the significant double curvature required to fully exploit their structural and architectural potential. This research focuses on sports facilities covered with textile membranes in the city of Niš. The aim of the study is to identify and systematize existing buildings of this typology. The results show that there are currently 20 such facilities in the wider area of the city. These facilities were visited, and relevant data were recorded and analyzed, with the results presented and discussed in this paper. In addition, six other textile-covered structures were identified but fall outside the scope of this research. These include four storage facilities, one protective cover for a historical site, and one canopy covering a restaurant garden. The analyzed textile structures exhibit significant diversity in several aspects, including ownership, structural system, permanence, and function. The findings of this study will be used to inform the development of improved textile cover designs for sports facilities in the region.
- Open Access
- 30 December 2025
- Published by Warsaw University of Life Sciences - SGGW Press in Acta Scientiarum Polonorum. Architectura
- Vol. 24, 380-389
Wood as an architectural medium: aesthetics, function and social perception from a historical and contemporary perspective
The objective of this article is to present the role of wood in contemporary architecture from the perspective of aesthetics, technology and social perception. The study is based on a review of literature from 2020 to 2025 (Scopus, Web of Science) and an analysis of the authors’ own projects. Wood’s natural texture and colour are conducive to creating friendly spaces rooted in tradition, while modern technologies enable its use in large, energy-efficient buildings. In social terms, this strengthens the identity of a place and openness to interaction, combining heritage with innovation. The conclusions emphasise the importance of wood as a key material for sustainable design, integrating aesthetic, technical and social values.
- 30 December 2025
- Published by Warsaw University of Life Sciences - SGGW Press in Acta Scientiarum Polonorum. Architectura
- Vol. 24, 380-389
Open AccessWood as an architectural medium: aesthetics, function and social perception from a historical and contemporary perspective
The objective of this article is to present the role of wood in contemporary architecture from the perspective of aesthetics, technology and social perception. The study is based on a review of literature from 2020 to 2025 (Scopus, Web of Science) and an analysis of the authors’ own projects. Wood’s natural texture and colour are conducive to creating friendly spaces rooted in tradition, while modern technologies enable its use in large, energy-efficient buildings. In social terms, this strengthens the identity of a place and openness to interaction, combining heritage with innovation. The conclusions emphasise the importance of wood as a key material for sustainable design, integrating aesthetic, technical and social values.