Matthias Richter
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Matthias Richter has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- Wolfgang Horn
Bundesanstalt für Materialforschung und -prüfung (BAM), Unter den Eichen 87, 12205 Berlin, Germany
7 shared publications Elevtheria Juritsch
Bundesanstalt für Materialforschung und -prüfung (BAM), Unter den Eichen 87, 12205 Berlin, Germany
5 shared publications- Morgane Even
German Federal Institute for Risk Assessment (BfR), Department of Chemical and Product Safety, Max-Dohrn-Strasse 8-10, 10589 Berlin, Germany
3 shared publications - Olaf Wilke
Bundesanstalt für Materialforschung und -prüfung, Unter den Eichen 87, Berlin, Berlin, 12205, GERMANY
3 shared publications Oliver Jann
Bundesanstalt für Materialforschung und -prüfung (BAM), Unter den Eichen 44-46, 12203, Berlin, Germany
3 shared publications- Oliver Jann
Federal Institute for Materials Research and Testing (BAM)
3 shared publications
Latest Publications
- Open Access
- 12 March 2026
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 224
Primary gas standards for the determination of sulfur-based impurities at trace level in hydrogen
- 12 March 2026
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 224
Open AccessPrimary gas standards for the determination of sulfur-based impurities at trace level in hydrogen
- Open Access
- 1 January 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
Sorbent-based active sampling method for the simultaneous analysis of very volatile, volatile, and semi-volatile organic compounds
TD-GC/MS using a dual-sorbent tube and serial PLOT/conventional GC columns enables simultaneous VVOC, VOC, and SVOC analysis in one run, providing high precision, excellent linearity, low LOD/LOQ, and supports efficient indoor air characterisation.
- 1 January 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
Open AccessSorbent-based active sampling method for the simultaneous analysis of very volatile, volatile, and semi-volatile organic compounds
TD-GC/MS using a dual-sorbent tube and serial PLOT/conventional GC columns enables simultaneous VVOC, VOC, and SVOC analysis in one run, providing high precision, excellent linearity, low LOD/LOQ, and supports efficient indoor air characterisation.
- Open Access
- 17 April 2025
- Published by Elsevier in Indoor Environments
- Vol. 2 (2)
Experimental determination of 7-day uptake rates for diffusive sampling of 86 volatile and semi-volatile organic compounds relevant for indoor air monitoring and investigation on their sensitivity to exposure time and indoor climate
- 17 April 2025
- Published by Elsevier in Indoor Environments
- Vol. 2 (2)
Open AccessExperimental determination of 7-day uptake rates for diffusive sampling of 86 volatile and semi-volatile organic compounds relevant for indoor air monitoring and investigation on their sensitivity to exposure time and indoor climate
- Open Access
- 4 December 2024
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 16 (50) , 69999-70009
Polymer Capsules with Volatile Organic Compounds as Reference Materials for Controlled Emission
Encapsulation of volatile organic compounds (VOCs) that could evaporate at a defined rate is of immense interest for application in emission reference materials (ERMs). Polyurethane/polyurea microcapsules with various VOC active ingredients (limonene, pinene, and toluene) were successfully produced by interfacial polymerization with Shirasu porous glass membrane emulsification in a size range between 10 and 50 mu m. The effect of surfactant, VOC, monomer(s) type, and ratio has a great effect on the formulation process and morphology of capsules. The type of VOC played a significant role in the encapsulation efficiency. Due to the difference in vapor pressure and VOC/water interfacial tension, the formulation for encapsulation was optimized for each individual VOC. Furthermore, to achieve effective stability of the large droplets/capsules, a combination of ionic and nonionic surfactants was used. Optical and scanning electron microscopy, Fourier transform infrared spectroscopy (FTIR), and thermogravimetric analysis (TGA), were used to characterize the optimized microcapsules. The results showed that the obtained microcapsules exhibited a spherical shape and core-shell morphology and featured characteristic urethane-urea bonds. The amount of encapsulated VOC ranges between 54 and 7 wt %. The emission tests were performed with the help of the emission test chamber procedure (EN 16516). The limonene-loaded polyurethane/polyurea microcapsules show a change in emission rate of less than 10% within 14 days and can be considered as a potential candidate for use as an ERM.
- 4 December 2024
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 16 (50) , 69999-70009
Open AccessPolymer Capsules with Volatile Organic Compounds as Reference Materials for Controlled Emission
Encapsulation of volatile organic compounds (VOCs) that could evaporate at a defined rate is of immense interest for application in emission reference materials (ERMs). Polyurethane/polyurea microcapsules with various VOC active ingredients (limonene, pinene, and toluene) were successfully produced by interfacial polymerization with Shirasu porous glass membrane emulsification in a size range between 10 and 50 mu m. The effect of surfactant, VOC, monomer(s) type, and ratio has a great effect on the formulation process and morphology of capsules. The type of VOC played a significant role in the encapsulation efficiency. Due to the difference in vapor pressure and VOC/water interfacial tension, the formulation for encapsulation was optimized for each individual VOC. Furthermore, to achieve effective stability of the large droplets/capsules, a combination of ionic and nonionic surfactants was used. Optical and scanning electron microscopy, Fourier transform infrared spectroscopy (FTIR), and thermogravimetric analysis (TGA), were used to characterize the optimized microcapsules. The results showed that the obtained microcapsules exhibited a spherical shape and core-shell morphology and featured characteristic urethane-urea bonds. The amount of encapsulated VOC ranges between 54 and 7 wt %. The emission tests were performed with the help of the emission test chamber procedure (EN 16516). The limonene-loaded polyurethane/polyurea microcapsules show a change in emission rate of less than 10% within 14 days and can be considered as a potential candidate for use as an ERM.
- Open Access
- 30 September 2024
- Published by Elsevier in Chemosphere
- Vol. 366, 143437
Towards a multi-VOC emission reference material with temporally constant emission profile for QA/QC of materials emission testing procedures
- 30 September 2024
- Published by Elsevier in Chemosphere
- Vol. 366, 143437
Open AccessTowards a multi-VOC emission reference material with temporally constant emission profile for QA/QC of materials emission testing procedures
- Open Access
- 13 July 2023
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 15 (31) , 3810-3821
On the use of Carbograph 5TD as an adsorbent for sampling VVOCs: validation of an analytical method
This paper reports the usability of the adsorbent Carbograph 5TD for the analysis of VVOCs in indoor air. It includes the whole validation chain from the determination of recovery, LOD/LOQ and robustness to measurement uncertainty.
- 13 July 2023
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 15 (31) , 3810-3821
Open AccessOn the use of Carbograph 5TD as an adsorbent for sampling VVOCs: validation of an analytical method
This paper reports the usability of the adsorbent Carbograph 5TD for the analysis of VVOCs in indoor air. It includes the whole validation chain from the determination of recovery, LOD/LOQ and robustness to measurement uncertainty.
- Open Access
- 19 December 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (3) , 035018
Metrological generation of SI-traceable gas-phase standards and reference materials for (semi-) volatile organic compounds
EN 16516 sets specifications for the determination of emissions into indoor air from construction products. Reliable, accurate and International System of Unit (SI)-traceable measurement results of the emissions are the key to consumer protection. Such measurement results can be obtained by using metrologically traceable reference materials. Gas-phase standards of volatile organic compounds (VOCs) in air can be prepared by a variety of dynamic methods according to the ISO 6145 series. However, these methods are not always applicable for semi-VOCs (SVOCs) due to their high boiling point and low vapour pressure. Therefore, a novel dynamic gas mixture generation system has been developed. With this system gas-phase standards with trace level VOCs and SVOCs in air can be prepared between 10 nmol mol−1 and 1000 nmol mol−1. The VOCs and SVOCs in this study have normal boiling points ranging from 146 °C to 343 °C. Metrologically traceable reference materials of the gas-phase standard were obtained by sampling of the VOC gas-phase standard into Tenax TA® sorbent material in SilcoNert® coated stainless steel tubes. Accurately known masses between 10 ng and 1000 ng per VOC were sampled. These reference materials were used to validate the dynamic system. Furthermore, the storage and stability periods of the VOCs in the reference materials were determined as these are crucial characteristics to obtain accurate and SI-traceable reference materials. In a round robin test (RRT), the reference materials were used with the aim of demonstrating the feasibility of providing SI-traceable standard reference values for SVOCs for interlaboratory comparison purposes. Based on the results from the validation, the storage and stability studies and the RRT, gas-phase standards and reference materials of VOCs and SVOCs with relative expanded uncertainties between 5% and 12% (k = 2) have been developed. These reference standards can be used as calibrants, reference materials or quality control materials for the analysis of VOC emissions.
- 19 December 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (3) , 035018
Open AccessMetrological generation of SI-traceable gas-phase standards and reference materials for (semi-) volatile organic compounds
EN 16516 sets specifications for the determination of emissions into indoor air from construction products. Reliable, accurate and International System of Unit (SI)-traceable measurement results of the emissions are the key to consumer protection. Such measurement results can be obtained by using metrologically traceable reference materials. Gas-phase standards of volatile organic compounds (VOCs) in air can be prepared by a variety of dynamic methods according to the ISO 6145 series. However, these methods are not always applicable for semi-VOCs (SVOCs) due to their high boiling point and low vapour pressure. Therefore, a novel dynamic gas mixture generation system has been developed. With this system gas-phase standards with trace level VOCs and SVOCs in air can be prepared between 10 nmol mol−1 and 1000 nmol mol−1. The VOCs and SVOCs in this study have normal boiling points ranging from 146 °C to 343 °C. Metrologically traceable reference materials of the gas-phase standard were obtained by sampling of the VOC gas-phase standard into Tenax TA® sorbent material in SilcoNert® coated stainless steel tubes. Accurately known masses between 10 ng and 1000 ng per VOC were sampled. These reference materials were used to validate the dynamic system. Furthermore, the storage and stability periods of the VOCs in the reference materials were determined as these are crucial characteristics to obtain accurate and SI-traceable reference materials. In a round robin test (RRT), the reference materials were used with the aim of demonstrating the feasibility of providing SI-traceable standard reference values for SVOCs for interlaboratory comparison purposes. Based on the results from the validation, the storage and stability studies and the RRT, gas-phase standards and reference materials of VOCs and SVOCs with relative expanded uncertainties between 5% and 12% (k = 2) have been developed. These reference standards can be used as calibrants, reference materials or quality control materials for the analysis of VOC emissions.
- Open Access
- 28 October 2022
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1238, 340561
Selection of gas standards, gas chromatography column and adsorbents for the measurement of very volatile organic compounds (C1–C6) in indoor air
- 28 October 2022
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1238, 340561
Open AccessSelection of gas standards, gas chromatography column and adsorbents for the measurement of very volatile organic compounds (C1–C6) in indoor air
- Open Access
- 1 July 2021
- Published by Elsevier in TrAC Trends in Analytical Chemistry
- Vol. 140
Measurement of very volatile organic compounds (VVOCs) in indoor air by sorbent-based active sampling: Identifying the gaps towards standardisation
- 1 July 2021
- Published by Elsevier in TrAC Trends in Analytical Chemistry
- Vol. 140
Open AccessMeasurement of very volatile organic compounds (VVOCs) in indoor air by sorbent-based active sampling: Identifying the gaps towards standardisation
- Open Access
- 3 May 2021
- Published by Wiley in Indoor Air
- Vol. 31 (6) , 2049-2057
Volatile organic compounds from building products—Results from six round robin tests with emission test chambers conducted between 2008 and 2018
Emission testing of volatile organic compounds (VOC) from materials and products is commonly based on emission test chamber measurements. To ensure the comparability of results from different testing laboratories, their measurement performance must be verified. For this purpose, Bundesanstalt für Materialforschung und ‐prüfung (BAM) organizes an international proficiency test (round robin test, RRT) every two years using well‐characterized test materials (one sealant, one furniture board, and four times a lacquer) with defined VOC emissions. The materials fulfilled the requirements of homogeneity, reproducibility, and stability. Altogether, 36 VOCs were included of which 33 gave test chamber air concentrations between 13 and 83 µg/m3. This is the typical concentration range to be expected and to be quantified when performing chamber tests. Three compounds had higher concentrations between 326 and 1105 µg/m3. In this paper, the relative standard deviations (RSD) of BAM round robin tests since 2008 are compared and the improvement of the comparability of the emission chamber testing is shown by the decrease of the mean RSD down to 28% in 2018. In contrast, the first large European interlaboratory comparison in 1999 showed a mean RSD of 51%.
- 3 May 2021
- Published by Wiley in Indoor Air
- Vol. 31 (6) , 2049-2057
Open AccessVolatile organic compounds from building products—Results from six round robin tests with emission test chambers conducted between 2008 and 2018
Emission testing of volatile organic compounds (VOC) from materials and products is commonly based on emission test chamber measurements. To ensure the comparability of results from different testing laboratories, their measurement performance must be verified. For this purpose, Bundesanstalt für Materialforschung und ‐prüfung (BAM) organizes an international proficiency test (round robin test, RRT) every two years using well‐characterized test materials (one sealant, one furniture board, and four times a lacquer) with defined VOC emissions. The materials fulfilled the requirements of homogeneity, reproducibility, and stability. Altogether, 36 VOCs were included of which 33 gave test chamber air concentrations between 13 and 83 µg/m3. This is the typical concentration range to be expected and to be quantified when performing chamber tests. Three compounds had higher concentrations between 326 and 1105 µg/m3. In this paper, the relative standard deviations (RSD) of BAM round robin tests since 2008 are compared and the improvement of the comparability of the emission chamber testing is shown by the decrease of the mean RSD down to 28% in 2018. In contrast, the first large European interlaboratory comparison in 1999 showed a mean RSD of 51%.