FMFrans Mast

Frans Mast

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Frans Mast has a total of 64 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers
    Open Access

    A systematic approach to searching: an efficient and complete method to develop literature searches

    by Wichor M. Bramer, Gerdien B. De Jonge, Melissa L. Rethlefsen, Frans Mast, Jos Kleijnen

    Creating search strategies for systematic reviews, finding the best balance between sensitivity and specificity, and translating search strategies between databases is challenging. Several methods describe standards for systematic search strategies, but a consistent approach for creating an exhaustive search strategy has not yet been fully described in enough detail to be fully replicable. The authors have established a method that describes step by step the process of developing a systematic search strategy as needed in the systematic review. This method describes how single-line search strategies can be prepared in a text document by typing search syntax (such as field codes, parentheses, and Boolean operators) before copying and pasting search terms (keywords and free-text synonyms) that are found in the thesaurus. To help ensure term completeness, we developed a novel optimization technique that is mainly based on comparing the results retrieved by thesaurus terms with those retrieved by the free-text search words to identify potentially relevant candidate search terms. Macros in Microsoft Word have been developed to convert syntaxes between databases and interfaces almost automatically. This method helps information specialists in developing librarian-mediated searches for systematic reviews as well as medical and health care practitioners who are searching for evidence to answer clinical questions. The described method can be used to create complex and comprehensive search strategies for different databases and interfaces, such as those that are needed when searching for relevant references for systematic reviews, and will assist both information specialists and practitioners when they are searching the biomedical literature.


  • Top Cited Papers
    Open Access

    Reviewing retrieved references for inclusion in systematic reviews using EndNote

    by Wichor M. Bramer, Jelena Milic, Frans Mast

    Reviewing retrieved references for inclusion in systematic reviews using EndNote


    • 23 November 2002
      • Vol. 146  (47) , 2250-2

    [Information provision for the biomedical sciences in the Netherlands faces an uncertain future].

    by H W J Deurenberg, J C M Figdor, J H Frijns, A W Koelstra, Frans Mast, M C Van Den Bosch, F Van Den Eeckhout

    The availability of biomedical information in the Netherlands is largely guaranteed by the libraries of the eight medical faculties and related university hospitals together with the Netherlands Institute for Scientific Information Services (Dutch acronym: NIWI). The acquisition of biomedical journals has always been coordinated at a national level. Up until now the NIWI has played a central role in filling in the gaps left by the other collections. It also functions as a national archive and a main document delivery centre. The NIWI receives financial support from the Dutch government to perform these tasks. Recently, NIWI announced that it intends to terminate its acquisition and document delivery service for the biomedical sciences. The remaining eight libraries foresee a number of negative effects if no alternatives to the present NIWI service are developed. We are of the opinion that this situation necessitates a national, biomedical information strategy.

  • Importance of right and left atrial dilation and linear ablation for perpetuation of sustained atrial fibrillation.

    by Markus Zarse, Jean-Claude Deharo, Frans Mast, Maurits A. Allessie, Maurits A. Allessie M.D.


  • Time Course of Atrial Fibrillation-induced Cellular Structural Remodeling in Atria of the Goat

    by Jannie Ausma, Nicolle Litjens, Marie-Hélène Lenders, Hans Duimel, Frans Mast, Luc Wouters, Frans Ramaekers, Maurits Allessie, Marcel Borgers


  • Methods for Determining the Refractory Period and Excitable Gap During Persistent Atrial Fibrillation in the Goat

    by Mattias Duytschaever, Frans Mast, Matthijs Killian, Yuri Blaauw, Maurits Wijffels, Maurits Allessie

    Background — Recently, the temporal excitable gap during atrial fibrillation (AF) has been identified as a vulnerable parameter for cardioversion of AF. In this study, we evaluated 5 methods to measure the refractory period (RP AF ) and the excitable period (EP AF ) during persistent AF. Methods and Results — In 11 goats instrumented with 83 epicardial atrial electrodes, persistent AF (43±34 days) was induced with a median AF cycle length (CL) of 98±14 ms. To measure RP AF , premature stimuli were applied to the center of the electrode array on the right or left atrium. The RP AF measured by mapping of premature stimuli was 70±12 ms (“gold standard”). The RP AF determined during entrainment of AF was 77±17 ms ( R 2 =0.88, P AF of 70±13 ms ( R 2 =0.94, P AF 71±17 ms, R 2 =0.84, P AF was 77±12 ms ( R 2 =0.90, P Conclusions — During persistent AF with an AFCL of 98±14 ms, the RP AF determined by mapping of synchronized premature stimuli (gold standard) was 70±12 ms, with an excitable period of 28±8 ms. Although the indirect methods to measure RP AF all correlated well with the gold standard, slow fixed-rate pacing seems to be the most attractive technique because of the ease of acquiring the data and the clear graphic result.


  • Widening of the Excitable Gap During Pharmacological Cardioversion of Atrial Fibrillation in the Goat

    by Maurits C. E. F. Wijffels, Rick Dorland, Frans Mast, Maurits A. Allessie

    Background—Previous studies suggest that the antifibrillatory action of class I and III drugs is due to prolongation of the atrial wavelength. The aim of the present study was to directly evaluate the electrophysiological action of antifibrillatory drugs in a goat model of chronic atrial fibrillation (AF).Methods and Results—Six goats were instrumented with multiple atrial electrodes, and sustained AF was induced by electrical remodeling. During sustained AF, the effects of intravenous infusion of cibenzoline, hydroquinidine, flecainide, andd-sotalol on AF cycle length (AFCL), refractory period (RPAF), conduction velocity (CVAF), pathlength (PLAF), wavelength (WLAF), temporal (AFCL−RPAF), and spatial (PLAF−WLAF) excitable gap were studied. The RPAFwas measured by determining the earliest moment at which single stimuli could capture the fibrillating atria. CVAFwas measured during regional entrainment of AF. Contrary to our expectation, cardioversion of AF could not be attributed to prolongation of WLAF. Hydroquinidine andd-sotalol did not affect WLAFsignificantly, whereas cibenzoline and flecainide even shortened WLAFby 18% and 36%, respectively. PLAFwas increased by hydroquinidine andd-sotalol by 30%, whereas cibenzoline and flecainide did not prolong PLAF. The only parameter that correlated consistently with cardioversion of AF was a widening of the temporal excitable gap (cibenzoline 176%, hydroquinidine 105%, flecainide 86%,d-sotalol 88%).Conclusions—Pharmacological cardioversion of AF cannot be explained by prolongation of WLAF. An alternative explanation for the antifibrillatory effect of class I and III drugs may be a widening of the temporal excitable gap.


  • Preferential Depression of Conduction Around a Pivot Point in Rabbit Ventricular Myocardium by Potassium and Flecainide

    by Peter W. Danse, Clifford J. Garratt, Frans Mast, Maurits A. Allessie

    Preferential Depression of Conduction at Pivot Points. Introduction: During reentrant arrhythmias, the circulating wavefront often makes a sharp turn around a functional or anatomic barrier. We tested the hypothesis that lowering the safety factor for conduction hy high K+ or flecainide preferentially depresses conduction of sharply turning wavefronts. Methods and Results: In 16 Langendorff‐perfused rahbit hearts, a thin layer of anisotropic ventricular myocardium was made using a cryoprocedure. In this layer, a linear radiofrequency lesion was made parallel to the fiber orientation. The tip of the lesion was extended by a short incision. U‐turning wavefronts were initiated by pacing at one side of the lesion. A mapping electrode (240 electrodes, resolution 350 to 700 μm) was used to measure conduction times and velocity of planar waves (longitudinal and transverse) and U‐turning wavefronts. The safety factor for conduction was lowered by high potassium (8, 10, and 12 mmol/L) and flecainide (1 and 2 mg/L). On average, high potassium and flecainide inereased the conduction times of U‐turning wavefronts 1.6 times more than longitudinal or transverse planar wavefronts (P < 0.01). At a critical lowering of the excitatory current, functional conduction block occurred at the pivot point, which forced the wavefront to make a longer U‐turn. In these cases, the total U‐turn conduction time increased from 27 ± 9 msec to 75 ± 37 msec. Ahout 40% of this delay was caused by a shift of the pivot point and consequent lengthening of the returning pathway. Conclusion: Lowering the amount of excitatory current by potassium or flecainide preferentially impairs U‐turn conduction. The occurrence of long delays and conduction block at pivot points may explain the mode of action of Class I drugs.


  • Repetitive Electrical Remodeling by Paroxysms of Atrial Fibrillation in the Goat:

    by Clifford J. Garratt, Mattias Duytschaever, Matthus Killian, Rick Dorland, Frans Mast, Maurits A. Allfssie

    Repetitive Atrial Electrical Remodeling. introduction: Episodes of atrial fibrillation (AF) are known to cause both a rapid reduction in atrial refractoriness (atrial electrical remodeling) and a more delayed increase in AF stability in the chronic goat model. The aims of this study were to examine (1) the hypothesis that an AF‐induced increase in AF stability might be due to a mechanism with a longer onset and offset than that of changes in refractoriness and (2) the possibility that repeated paroxysms of maintained AF might cause a cumulative increase in AF stability independent of changes in atrial refractoriness. Methods and Results: AF was maintained by rapid atrial pacing in seven goats for three consecutive 5‐day periods, each separated from each other by 48 hours of sinus rhythm. Assessments of atrial refractory periods, conduction velocity, AF inducibility, and duration of individual episodes of AF were attempted at intervals throughout the protocol. Forty‐eight hours of sinus rhythm was just sufficient for refractoriness changes to fully reverse in all goats, with no evidence of any “residual” increase in AF inducibility. There was no significant difference among any of the three periods of pacing‐maintained AF with regard to time to develop episodes of AF of 60‐second duration (22.1 ± 13, 23.8 ± 16, and 30.3 ± 29 hours), 1‐hour duration (56.6 ± 28, 61.3 ± 31, and 60.1 ± 32 hours), or 24‐hour duration (84.0 ± 31, 87.0 ± 33, and 83.5 ± 32 hours). Conclusion: There is no evidence for a cumulative effect of AF paroxysms on AF inducibility or stability independent of changes in refractoriness. These findings highlight the importance of atrial refractoriness as a potential target for antiarrhythmic strategies aimed at inhibiting the self‐perpetuation of AF.


  • In vitro biocompatibility of EPM and EPDM rubbers

    by F Mast, J. A. R. D Hoschtitzky, C. A VAN Blitterswijk, H. A Huysmans

    The in vitro toxicity of two EPDM rubbers (K 778 and K 4802) and one EPM rubber (K 740) was tested using human fibroblasts. The modulus of elasticity of each rubber was varied by exposure to different amounts of electron-beam radiation (0, 5 and 10 Mrad). The short-term in vitro toxicity was tested by culturing cells on polymer films. The long-term effect of ageing was simulated by growing fibroblasts in nutrient media prepared from extracts of heat-exposed materials. Cell cultures were studied both quantitatively and (ultra) structurally. Growth curves obtained in the toxicity test did not differ significantly from control values at any day of observation, and also showed that electron-beam radiation did not alter the biocompatibility. The same results were found for all but one material in the artificial ageing test. The number of cells in the K4802/10 Mrad extraction medium was decreased. Ultrastructurally no gross deviations from normal morphology were observed, either in the direct contact test or in the artificial ageing test. The most characteristic feature was a somewhat dilated endoplasmic reticulum. In summary, the in vitro biocompatibility of EPDM-rubbers as observed in this study is satisfactory and motivates further investigation of their biocompatibility in animal experiments.