Kubilay Aydin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kubilay Aydin has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
- Mehmet Barburoglu
Istanbul University
9 shared publications - Serra Sencer
Department of Radiology, Istanbul Faculty of Medicine, Istanbul University, Istanbul, Turkey
8 shared publications Mynzhylky Berdikhojayev
Department of Interventional Radiology, Fatih Sultan Mehmet Training and Research Hospital
5 shared publicationsMehmet Barburoglu
Department of Neuroradiology, Istanbul University, Istanbul Faculty of Medicine, Capa, Istanbul, Turkey
4 shared publicationsSerra Sencer
Department of Neuroradiology, Istanbul University, Istanbul Faculty of Medicine, Capa, Istanbul, Turkey
4 shared publications- Cafer Ikbal Gulsever
Department of Neurosurgery, Istanbul Faculty of Medicine, Istanbul University, Istanbul, Turkey
3 shared publications
Latest Publications
- Open Access
- 19 October 2026
- Published by Elsevier in World Neurosurgery
- Vol. 216
Y-Configuration Dual Stent Retriever Thrombectomy for Bifurcation Occlusions in Acute Ischemic Stroke
- 19 October 2026
- Published by Elsevier in World Neurosurgery
- Vol. 216
Open AccessY-Configuration Dual Stent Retriever Thrombectomy for Bifurcation Occlusions in Acute Ischemic Stroke
- Open Access
- 30 March 2026
- Published by Elsevier in World Neurosurgery
- Vol. 210, 124960
Mid- to Long-Term Outcomes of Intracranial Aneurysms Treated with the Silk Flow Diverter: A Single-Center Experience
- 30 March 2026
- Published by Elsevier in World Neurosurgery
- Vol. 210, 124960
Open AccessMid- to Long-Term Outcomes of Intracranial Aneurysms Treated with the Silk Flow Diverter: A Single-Center Experience
- 15 December 2025
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 49 (3) , 604-612
Safety and Efficacy of Ticagrelor-Based Dual Antiplatelet Therapy in Endovascular Treatment of Unruptured Intracranial Aneurysms: A Large Single-Center Retrospective Study
Purpose To evaluate the safety and efficacy of ticagrelor-based dual antiplatelet therapy (DUAP) in patients undergoing stent-assisted endovascular treatment (EVT) of unruptured intracranial aneurysms (UIAs) in a large single-center cohort. Methods We retrospectively analyzed 153 patients who underwent elective stent-assisted EVT for UIAs and were exclusively managed with aspirin and ticagrelor from January 2021 to December 2024. Clinical outcomes included thromboembolic events (cTE), hemorrhagic events (HE), disability, and mortality. Follow-up involved cone-beam CT for early hemorrhagic complications, scheduled MRI/MR-A, and digital subtraction angiography (DSA) at six months. Outcomes were compared across treatment types: stent-assisted coil embolization (SACE, laser-cut or braided), Y-stenting, flow diversion (FD), and stent monotherapy. Results Among 153 patients (mean age 54.8 ± 13.2 years; 75.2% female), thromboembolic events occurred in 4 (2.6%) and hemorrhagic events in 6 (3.9%) cases during a mean follow-up of 22.5 ± 15.9 months. Permanent disability occurred in 3 patients (2.0%) and mortality in 2 (1.3%). Event rates did not differ significantly among treatment subgroups (p > 0.05). Conclusion Ticagrelor-based DUAP was associated with low thromboembolic and hemorrhagic complication rates in patients undergoing stent-assisted endovascular treatment of unruptured intracranial aneurysms, supporting its safety and efficacy in this setting. Graphical Abstract
- 15 December 2025
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 49 (3) , 604-612
Safety and Efficacy of Ticagrelor-Based Dual Antiplatelet Therapy in Endovascular Treatment of Unruptured Intracranial Aneurysms: A Large Single-Center Retrospective Study
Purpose To evaluate the safety and efficacy of ticagrelor-based dual antiplatelet therapy (DUAP) in patients undergoing stent-assisted endovascular treatment (EVT) of unruptured intracranial aneurysms (UIAs) in a large single-center cohort. Methods We retrospectively analyzed 153 patients who underwent elective stent-assisted EVT for UIAs and were exclusively managed with aspirin and ticagrelor from January 2021 to December 2024. Clinical outcomes included thromboembolic events (cTE), hemorrhagic events (HE), disability, and mortality. Follow-up involved cone-beam CT for early hemorrhagic complications, scheduled MRI/MR-A, and digital subtraction angiography (DSA) at six months. Outcomes were compared across treatment types: stent-assisted coil embolization (SACE, laser-cut or braided), Y-stenting, flow diversion (FD), and stent monotherapy. Results Among 153 patients (mean age 54.8 ± 13.2 years; 75.2% female), thromboembolic events occurred in 4 (2.6%) and hemorrhagic events in 6 (3.9%) cases during a mean follow-up of 22.5 ± 15.9 months. Permanent disability occurred in 3 patients (2.0%) and mortality in 2 (1.3%). Event rates did not differ significantly among treatment subgroups (p > 0.05). Conclusion Ticagrelor-based DUAP was associated with low thromboembolic and hemorrhagic complication rates in patients undergoing stent-assisted endovascular treatment of unruptured intracranial aneurysms, supporting its safety and efficacy in this setting. Graphical Abstract
- 28 May 2024
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 42 (10) , 1138-1145
Tortuous occipital emissary vein combined with dural venous sinus stenosis in contrast-enhanced MRV for evaluation of idiopathic intracranial hypertension
Purpose Venous outflow impediment is increasingly recognized in idiopathic intracranial hypertension (IIH). We aim to search for the value of tortuous occipital emissary vein (OEV) in IIH by integrating measurable transverse sinus (TS) stenosis in contrast-enhanced MR venography (CE-MRV). Methods Twenty-one IIH patients were evaluated with CE-MRV. Each patient had high LP opening pressure (> 25 cm.H2O), and presented papilledema. Age- and sex-matched 21 control subjects who underwent cranial CE-MRV were selected. The OEV and the following features: intraosseous diameter of more than 3 mm, twisted course, and continuous with prominent sub-occipital extracranial veins were named tortuous OEV. TS stenosis was measured by utilizing the coronal T1-VIBE series to calculate quantitative metrics such as TS max./min.. The tortuous OEV and TS max./min. were registered to create a bivariate logistic regression model to assess the performance of tortuous OEV for IIH when accompanied by TS stenosis. Results Six (29%) tortuous OEVs were observed in the IIH group, while no tortuous OEV was identified in the control group (p = 0.021). The mean TSmax./min. was 2.48 ± 1.19 in patients with IIH and 1.23 ± 0.33 in the control group (p < 0.001). According to regression analysis, tortuous OEV is not predictive of IIH (p = 0.999), while the higher TSmax./min. (> 1.69) is predictive of IIH (p = 0.022, OR: 8.9; %95 CI; 1.4–59.0) when accompanied together. Conclusion Tortuous occipital emissary vein is more frequently seen in patients with IIH. However, the tortuous appearance alone does not predict idiopathic intracranial hypertension unless associated with measurable transverse sinus narrowing in CE-MRV.
- 28 May 2024
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 42 (10) , 1138-1145
Tortuous occipital emissary vein combined with dural venous sinus stenosis in contrast-enhanced MRV for evaluation of idiopathic intracranial hypertension
Purpose Venous outflow impediment is increasingly recognized in idiopathic intracranial hypertension (IIH). We aim to search for the value of tortuous occipital emissary vein (OEV) in IIH by integrating measurable transverse sinus (TS) stenosis in contrast-enhanced MR venography (CE-MRV). Methods Twenty-one IIH patients were evaluated with CE-MRV. Each patient had high LP opening pressure (> 25 cm.H2O), and presented papilledema. Age- and sex-matched 21 control subjects who underwent cranial CE-MRV were selected. The OEV and the following features: intraosseous diameter of more than 3 mm, twisted course, and continuous with prominent sub-occipital extracranial veins were named tortuous OEV. TS stenosis was measured by utilizing the coronal T1-VIBE series to calculate quantitative metrics such as TS max./min.. The tortuous OEV and TS max./min. were registered to create a bivariate logistic regression model to assess the performance of tortuous OEV for IIH when accompanied by TS stenosis. Results Six (29%) tortuous OEVs were observed in the IIH group, while no tortuous OEV was identified in the control group (p = 0.021). The mean TSmax./min. was 2.48 ± 1.19 in patients with IIH and 1.23 ± 0.33 in the control group (p < 0.001). According to regression analysis, tortuous OEV is not predictive of IIH (p = 0.999), while the higher TSmax./min. (> 1.69) is predictive of IIH (p = 0.022, OR: 8.9; %95 CI; 1.4–59.0) when accompanied together. Conclusion Tortuous occipital emissary vein is more frequently seen in patients with IIH. However, the tortuous appearance alone does not predict idiopathic intracranial hypertension unless associated with measurable transverse sinus narrowing in CE-MRV.
- 12 December 2022
- Published by Wolters Kluwer Health in Neurosurgery
- Vol. 92 (4) , 827-836
The Angiographic and Clinical Follow-up Outcomes of the Wide-Necked and Complex Intracranial Aneurysms Treated With LVIS EVO–Assisted Coiling
BACKGROUND: The Low Profile Visible Intraluminal Support EVO (LVIS EVO) is a self-expandable braided stent, which was recently introduced for the treatment of intracranial aneurysms. Full visibility of the stent and a relatively high metal coverage ratio are the unique features of the LVIS EVO. OBJECTIVE: To assess the safety, efficacy, and midterm durability of LVIS EVO stent-assisted coiling for the treatment of wide-necked intracranial aneurysms. METHODS: The endovascular databases were reviewed to identify patients treated with LVIS EVO–assisted coiling. The technical success and immediate clinical/angiographic outcomes were assessed. Periprocedural and delayed complications were evaluated. The follow-up angiographic/clinical outcomes were investigated. The preprocedural/follow-up neurological statuses were assessed with the modified Rankin Scale. RESULTS: One hundred three aneurysms in 103 patients (63 females) with a mean age of 54.9 ± 11.3 years were included. The mean maximum sac diameter was 6.2 ± 2.9 mm. The procedural technical success rate was 100%. Immediate postprocedural angiography showed complete occlusion in 77.7%. The mean duration of the angiographic follow-up was 8.8 ± 3.6 months. Follow-up angiography showed complete aneurysm occlusion in 89% of the 82 patients with angiographic follow-up. Recanalization was observed in 7.3% of 82 patients. Two patients (2.4%) required retreatment. In addition, 8.7% of the patients had at least 1 complication, and 2.9% of the patients developed a permanent morbidity. All patients had mRS scores ≤2. CONCLUSION: The results of this study demonstrate that SAC with LVIS EVO is a relatively safe, efficient, and durable treatment for wide-necked and complex intracranial aneurysms.
- 12 December 2022
- Published by Wolters Kluwer Health in Neurosurgery
- Vol. 92 (4) , 827-836
The Angiographic and Clinical Follow-up Outcomes of the Wide-Necked and Complex Intracranial Aneurysms Treated With LVIS EVO–Assisted Coiling
BACKGROUND: The Low Profile Visible Intraluminal Support EVO (LVIS EVO) is a self-expandable braided stent, which was recently introduced for the treatment of intracranial aneurysms. Full visibility of the stent and a relatively high metal coverage ratio are the unique features of the LVIS EVO. OBJECTIVE: To assess the safety, efficacy, and midterm durability of LVIS EVO stent-assisted coiling for the treatment of wide-necked intracranial aneurysms. METHODS: The endovascular databases were reviewed to identify patients treated with LVIS EVO–assisted coiling. The technical success and immediate clinical/angiographic outcomes were assessed. Periprocedural and delayed complications were evaluated. The follow-up angiographic/clinical outcomes were investigated. The preprocedural/follow-up neurological statuses were assessed with the modified Rankin Scale. RESULTS: One hundred three aneurysms in 103 patients (63 females) with a mean age of 54.9 ± 11.3 years were included. The mean maximum sac diameter was 6.2 ± 2.9 mm. The procedural technical success rate was 100%. Immediate postprocedural angiography showed complete occlusion in 77.7%. The mean duration of the angiographic follow-up was 8.8 ± 3.6 months. Follow-up angiography showed complete aneurysm occlusion in 89% of the 82 patients with angiographic follow-up. Recanalization was observed in 7.3% of 82 patients. Two patients (2.4%) required retreatment. In addition, 8.7% of the patients had at least 1 complication, and 2.9% of the patients developed a permanent morbidity. All patients had mRS scores ≤2. CONCLUSION: The results of this study demonstrate that SAC with LVIS EVO is a relatively safe, efficient, and durable treatment for wide-necked and complex intracranial aneurysms.
- 17 March 2022
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 43 (4) , 560-567
Safety, Efficacy, and Durability of Stent-Assisted Coiling Treatment of M2 (Insular) Segment MCA Aneurysms
BACKGROUND AND PURPOSE: Most distal MCA aneurysms are located within the insular segment, which lies between the limen insulae and circular sulcus. However, experience is limited in the microsurgical and endovascular management of insular segment MCA aneurysms. In this multicenter retrospective case series, we aimed to investigate the safety, efficacy, and durability of stent-assisted coiling for treatment of insular segment MCA aneurysms. MATERIALS AND METHODS: A retrospective review was performed to identify patients with insular MCA aneurysms that were treated with stent-assisted coiling. The technical success of the procedures and the initial and follow-up clinical and angiographic outcomes were assessed. Periprocedural and delayed complications were reviewed. RESULTS: Twenty-seven aneurysms in 27 patients with a mean age of 53.3 (SD,11.3) years were included. The mean size of the aneurysms was 6.3 (SD 2.6) mm. Endovascular procedures were successfully performed in all patients. Immediate postprocedural angiography revealed complete aneurysm occlusions in 81.5%. Periprocedural complications developed in 7.4% without causing permanent morbidity. A delayed thromboembolic complication resulted in a minor permanent morbidity in 1 patient (3.7%). There was no mortality. The mean duration of angiographic follow-up was 19.5 (SD, 9.8) months. The last follow-up examinations showed complete occlusion in 92.6%. During the follow-up period, none of the treated aneurysms showed recanalization. CONCLUSIONS: The results of this study demonstrate that stent-assisted coiling with a low-profile self-expandable stent is a feasible and relatively safe technique for endovascular treatment of insular segment complex MCA aneurysms. Additionally, it provides an effective and durable treatment for insular MCA aneurysms.
- 17 March 2022
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 43 (4) , 560-567
Safety, Efficacy, and Durability of Stent-Assisted Coiling Treatment of M2 (Insular) Segment MCA Aneurysms
BACKGROUND AND PURPOSE: Most distal MCA aneurysms are located within the insular segment, which lies between the limen insulae and circular sulcus. However, experience is limited in the microsurgical and endovascular management of insular segment MCA aneurysms. In this multicenter retrospective case series, we aimed to investigate the safety, efficacy, and durability of stent-assisted coiling for treatment of insular segment MCA aneurysms. MATERIALS AND METHODS: A retrospective review was performed to identify patients with insular MCA aneurysms that were treated with stent-assisted coiling. The technical success of the procedures and the initial and follow-up clinical and angiographic outcomes were assessed. Periprocedural and delayed complications were reviewed. RESULTS: Twenty-seven aneurysms in 27 patients with a mean age of 53.3 (SD,11.3) years were included. The mean size of the aneurysms was 6.3 (SD 2.6) mm. Endovascular procedures were successfully performed in all patients. Immediate postprocedural angiography revealed complete aneurysm occlusions in 81.5%. Periprocedural complications developed in 7.4% without causing permanent morbidity. A delayed thromboembolic complication resulted in a minor permanent morbidity in 1 patient (3.7%). There was no mortality. The mean duration of angiographic follow-up was 19.5 (SD, 9.8) months. The last follow-up examinations showed complete occlusion in 92.6%. During the follow-up period, none of the treated aneurysms showed recanalization. CONCLUSIONS: The results of this study demonstrate that stent-assisted coiling with a low-profile self-expandable stent is a feasible and relatively safe technique for endovascular treatment of insular segment complex MCA aneurysms. Additionally, it provides an effective and durable treatment for insular MCA aneurysms.
- 8 March 2022
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 22 (5) , 277-283
Feasibility and Results of the Stentectomy Procedure Performed as Rescue Treatment for Acute Thrombosis of Self-Expandable Intracranial Stents: A Case Series
BACKGROUND: Self-expandable stents have been increasingly used for endovascular treatment of intracranial aneurysms. Because the usage of intracranial stents has increased overall, total numbers of complications associated with these devices have increased. Thrombosis, distortion, or incomplete opening of stents are potential complications that may result in occlusion of the parent artery. In such cases, removal of the stent (stentectomy) may be the only solution to avoid serious clinical consequences. OBJECTIVE: To investigate the feasibility and efficacy of a novel stentectomy technique for removal of thrombosed self-expandable stents. METHODS: A retrospective review was performed of patients who underwent the stentectomy procedure. Initial and follow-up imaging and clinical outcomes were assessed. Immediate postprocedural and follow-up clinical statuses were assessed using the modified Rankin scale. RESULTS: Seven patients were included in this study (mean age: 54.1 years). The stentectomy was successful in 6 of 7 patients (85.7%). Seven stents in 6 patients were successfully removed to treat the acute in-stent thrombosis that was resistant to alternative bail-out treatments. The removed stents were self-expandable braided in 2 patients, flow diverters in 2 patients, and laser cut open-cell stents in 2 patients. Stentectomy failed to retrieve a thrombosed braided stent in 1 patient. The modified Rankin scale score of all patients who underwent a success stentectomy was ≤1. CONCLUSION: The stentectomy procedure using the defined technique is feasible to retrieve thrombosed stents and effective to restore the blood flow. It can be considered a last resort option to treat acute in-stent thrombosis resistant to alternative bail-out treatments.
- 8 March 2022
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 22 (5) , 277-283
Feasibility and Results of the Stentectomy Procedure Performed as Rescue Treatment for Acute Thrombosis of Self-Expandable Intracranial Stents: A Case Series
BACKGROUND: Self-expandable stents have been increasingly used for endovascular treatment of intracranial aneurysms. Because the usage of intracranial stents has increased overall, total numbers of complications associated with these devices have increased. Thrombosis, distortion, or incomplete opening of stents are potential complications that may result in occlusion of the parent artery. In such cases, removal of the stent (stentectomy) may be the only solution to avoid serious clinical consequences. OBJECTIVE: To investigate the feasibility and efficacy of a novel stentectomy technique for removal of thrombosed self-expandable stents. METHODS: A retrospective review was performed of patients who underwent the stentectomy procedure. Initial and follow-up imaging and clinical outcomes were assessed. Immediate postprocedural and follow-up clinical statuses were assessed using the modified Rankin scale. RESULTS: Seven patients were included in this study (mean age: 54.1 years). The stentectomy was successful in 6 of 7 patients (85.7%). Seven stents in 6 patients were successfully removed to treat the acute in-stent thrombosis that was resistant to alternative bail-out treatments. The removed stents were self-expandable braided in 2 patients, flow diverters in 2 patients, and laser cut open-cell stents in 2 patients. Stentectomy failed to retrieve a thrombosed braided stent in 1 patient. The modified Rankin scale score of all patients who underwent a success stentectomy was ≤1. CONCLUSION: The stentectomy procedure using the defined technique is feasible to retrieve thrombosed stents and effective to restore the blood flow. It can be considered a last resort option to treat acute in-stent thrombosis resistant to alternative bail-out treatments.
- 19 August 2021
- Published by Wolters Kluwer Health in Neurosurgery
- Vol. 89 (5) , E274-E276
In Reply: Safety, Efficacy, and Durability of Stent Plus Balloon-Assisted Coiling for the Treatment of Wide-Necked Intracranial Bifurcation Aneurysms
- 19 August 2021
- Published by Wolters Kluwer Health in Neurosurgery
- Vol. 89 (5) , E274-E276
In Reply: Safety, Efficacy, and Durability of Stent Plus Balloon-Assisted Coiling for the Treatment of Wide-Necked Intracranial Bifurcation Aneurysms
- 11 February 2021
- Published by Wolters Kluwer Health in Neurosurgery
- Vol. 88 (5) , 1028-1037
Safety, Efficacy, and Durability of Stent Plus Balloon-Assisted Coiling for the Treatment of Wide-Necked Intracranial Bifurcation Aneurysms
BACKGROUND: Wide-necked bifurcation aneurysms remain a challenge for endovascular surgeons. Dual-stent-assisted coiling techniques have been defined to treat bifurcation aneurysms with a complex neck morphology. However, there are still concerns about the safety of dual-stenting procedures. Stent plus balloon-assisted coiling is a recently described endovascular technique that enables the coiling of wide-necked complex bifurcation aneurysms by implanting only a single stent. OBJECTIVE: To investigate the feasibility, efficacy, safety, and durability of this technique for the treatment of wide-necked bifurcation aneurysms. METHODS: A retrospective review was performed of patients with wide-necked intracranial bifurcation aneurysms treated with stent plus balloon-assisted coiling. The initial and follow-up clinical and angiographic outcomes were assessed. Preprocedural and follow-up clinical statuses were assessed using modified Rankin scale. RESULTS: A total of 61 patients (mean age: 54.6 ± 10.4 yr) were included in the study. The immediate postprocedural digital subtraction angiography revealed complete aneurysm occlusion in 86.9% of the cases. A periprocedural complication developed in 11.5% of the cases. We observed a delayed ischemic complication in 4.9%. There was no mortality in this study. The permanent morbidity rate was 3.3%. The follow-up angiography was performed in 55 of 61 patients (90.1%) (the mean follow-up period was 25.5 ± 27.3 mo). The rate of complete aneurysm occlusion at the final angiographic follow-up was 89.1%. The retreatment rate was 1.8%. CONCLUSION: The results of this study showed that stent plus balloon-assisted coiling is a feasible, effective, and relatively safe endovascular technique for the treatment of wide-necked bifurcation aneurysms located in the posterior and anterior circulation.
- 11 February 2021
- Published by Wolters Kluwer Health in Neurosurgery
- Vol. 88 (5) , 1028-1037
Safety, Efficacy, and Durability of Stent Plus Balloon-Assisted Coiling for the Treatment of Wide-Necked Intracranial Bifurcation Aneurysms
BACKGROUND: Wide-necked bifurcation aneurysms remain a challenge for endovascular surgeons. Dual-stent-assisted coiling techniques have been defined to treat bifurcation aneurysms with a complex neck morphology. However, there are still concerns about the safety of dual-stenting procedures. Stent plus balloon-assisted coiling is a recently described endovascular technique that enables the coiling of wide-necked complex bifurcation aneurysms by implanting only a single stent. OBJECTIVE: To investigate the feasibility, efficacy, safety, and durability of this technique for the treatment of wide-necked bifurcation aneurysms. METHODS: A retrospective review was performed of patients with wide-necked intracranial bifurcation aneurysms treated with stent plus balloon-assisted coiling. The initial and follow-up clinical and angiographic outcomes were assessed. Preprocedural and follow-up clinical statuses were assessed using modified Rankin scale. RESULTS: A total of 61 patients (mean age: 54.6 ± 10.4 yr) were included in the study. The immediate postprocedural digital subtraction angiography revealed complete aneurysm occlusion in 86.9% of the cases. A periprocedural complication developed in 11.5% of the cases. We observed a delayed ischemic complication in 4.9%. There was no mortality in this study. The permanent morbidity rate was 3.3%. The follow-up angiography was performed in 55 of 61 patients (90.1%) (the mean follow-up period was 25.5 ± 27.3 mo). The rate of complete aneurysm occlusion at the final angiographic follow-up was 89.1%. The retreatment rate was 1.8%. CONCLUSION: The results of this study showed that stent plus balloon-assisted coiling is a feasible, effective, and relatively safe endovascular technique for the treatment of wide-necked bifurcation aneurysms located in the posterior and anterior circulation.
- 1 January 2021
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 134 (1) , 39-48
Long-term outcomes of wide-necked intracranial bifurcation aneurysms treated with T-stent–assisted coiling
OBJECTIVE: The endovascular treatment of complex bifurcation aneurysms possessing a neck that incorporates multiple side branches remains a surgical challenge. Double-stent–assisted coiling techniques, such as those with stents in an X and Y configuration, enable the endovascular treatment of wide-necked complex intracranial bifurcation aneurysms. However, the intraluminal struts at the intersection point in X- and Y-stents are not amenable to endothelialization, which may lead to thromboembolic complications. Stenting in the T configuration is a relatively new double-stent coiling technique. T-stenting differs from X- or Y-stenting in that there are no overlapping or intersecting stent segments. Promising short-term results of T-stent–assisted coiling were recently reported. However, the long-term results have not yet been demonstrated. This retrospective study investigated the long-term angiographic and clinical results in patients with wide-necked complex intracranial bifurcation aneurysms treated with T-stent–assisted coiling. METHODS: A retrospective review was performed to identify patients with wide-necked complex intracranial bifurcation aneurysms treated with T-stent–assisted coiling at 4 institutions. The technical success and the initial and follow-up clinical and angiographic outcomes were assessed. Aneurysm filling status was assessed according to the Raymond classification. Periprocedural and delayed complications were reviewed. The neurological status of the patients was evaluated using the modified Rankin Scale (mRS). RESULTS: One hundred two aneurysms in 102 patients (54 females), whose mean age was 57.9 ± 13.0 years, were included in the study. T-stenting was performed successfully in all patients. Immediate postprocedural angiography revealed complete occlusion in 83.3% of patients. Periprocedural complications developed in 13.7%, resulting in permanent morbidity in 1.9% and death in 1%. Eighty patients (78.4%) had at least one follow-up DSA examination performed at 6 months or later following the endovascular procedure. The mean duration of angiographic follow-up was 30.0 ± 16.3 months. The last follow-up examinations showed complete occlusion in 90.0% of patients. During the follow-up period, only 1 patient (1.3%) required retreatment. Delayed thromboembolic complications were observed in 4 patients (3.9%) without permanent morbidity. The mRS scores of all patients at the last clinical follow-up were between 0 and 2. CONCLUSIONS: The short-term angiographic findings showed that T-stent–assisted coiling is a feasible and effective endovascular method to treat wide-necked complex bifurcation aneurysms. The long-term angiographic follow-up results suggest that T-stent–assisted coiling provides a durable treatment for wide-necked complex bifurcation aneurysms with favorable clinical outcomes, demonstrating the long-term safety of T-stent–assisted coiling.
- 1 January 2021
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 134 (1) , 39-48
Long-term outcomes of wide-necked intracranial bifurcation aneurysms treated with T-stent–assisted coiling
OBJECTIVE: The endovascular treatment of complex bifurcation aneurysms possessing a neck that incorporates multiple side branches remains a surgical challenge. Double-stent–assisted coiling techniques, such as those with stents in an X and Y configuration, enable the endovascular treatment of wide-necked complex intracranial bifurcation aneurysms. However, the intraluminal struts at the intersection point in X- and Y-stents are not amenable to endothelialization, which may lead to thromboembolic complications. Stenting in the T configuration is a relatively new double-stent coiling technique. T-stenting differs from X- or Y-stenting in that there are no overlapping or intersecting stent segments. Promising short-term results of T-stent–assisted coiling were recently reported. However, the long-term results have not yet been demonstrated. This retrospective study investigated the long-term angiographic and clinical results in patients with wide-necked complex intracranial bifurcation aneurysms treated with T-stent–assisted coiling. METHODS: A retrospective review was performed to identify patients with wide-necked complex intracranial bifurcation aneurysms treated with T-stent–assisted coiling at 4 institutions. The technical success and the initial and follow-up clinical and angiographic outcomes were assessed. Aneurysm filling status was assessed according to the Raymond classification. Periprocedural and delayed complications were reviewed. The neurological status of the patients was evaluated using the modified Rankin Scale (mRS). RESULTS: One hundred two aneurysms in 102 patients (54 females), whose mean age was 57.9 ± 13.0 years, were included in the study. T-stenting was performed successfully in all patients. Immediate postprocedural angiography revealed complete occlusion in 83.3% of patients. Periprocedural complications developed in 13.7%, resulting in permanent morbidity in 1.9% and death in 1%. Eighty patients (78.4%) had at least one follow-up DSA examination performed at 6 months or later following the endovascular procedure. The mean duration of angiographic follow-up was 30.0 ± 16.3 months. The last follow-up examinations showed complete occlusion in 90.0% of patients. During the follow-up period, only 1 patient (1.3%) required retreatment. Delayed thromboembolic complications were observed in 4 patients (3.9%) without permanent morbidity. The mRS scores of all patients at the last clinical follow-up were between 0 and 2. CONCLUSIONS: The short-term angiographic findings showed that T-stent–assisted coiling is a feasible and effective endovascular method to treat wide-necked complex bifurcation aneurysms. The long-term angiographic follow-up results suggest that T-stent–assisted coiling provides a durable treatment for wide-necked complex bifurcation aneurysms with favorable clinical outcomes, demonstrating the long-term safety of T-stent–assisted coiling.